header advert
Results 1 - 1 of 1
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 106 - 107
1 Mar 2008
Beingessner D Dunning C Stacpoole R Johnson J King G
Full Access

Passive and active elbow flexion was performed in eight cadaveric arms to determine the effect of Type 1 coronoid fractures and suture repair on kinematics. Testing was performed in ligamentously intact and MCL deficient elbows; with radial head arthroplasty (RHA); with an intact coronoid, following a Type 1 fracture, and with suture repair of the coronoid. There was an alteration in elbow kinematics and stability following Type 1 coronoid fractures that was not corrected with coronoid repair. Suture fixation of the coronoid is probably unnecessary if the lateral ligaments are repaired and the radial head is repaired or replaced.

To determine the effect of fixation of Type 1 coronoid fractures on elbow stability and kinematics in ligamentously intact and medial collateral ligament (MCL) deficient elbows with radial head arthroplasty (RHA).

Type 1 coronoid fractures cause changes in elbow kinematics and stability that are not corrected with suture repair.

Suture fixation of Type 1 coronoid fractures is probably unnecessary if the lateral ligaments are repaired and the radial head is repaired or replaced.

With intact ligaments, there was an increase in valgus angulation following a Type 1 coronoid fracture (p< 0.05) that was not corrected with fixation. With MCL deficiency, there was no change in valgus angulation for all coronoid states. For both ligament states, there was an increase maximum varus-valgus laxity after a Type 1 coronoid fracture with forearm pronation (p=0.03) that was not corrected with fixation (p=0.4). Kinematic data was collected from eight cadaveric arms during passive and simulated active elbow motion. The protocol was performed in stable and MCL deficient elbows with RHA. Testing occurred with the coronoid intact, following Type 1 coronoid fracture, and with suture repair of the fracture. Valgus angulation and maximum varus-valgus laxity were measured.

With intact ligaments, Type 1 coronoid fractures cause an alteration in elbow kinematics and laxity that is not corrected with suture fixation. With MCL disruption, Type 1 coronoid fractures have no effect on elbow kinematics and a small effect on laxity that is not corrected with coronoid repair.

Funding: Research and Institutional Support received from Wright Medical Technologies.

Please contact author for graphs and/or diagrams.