header advert
Results 81 - 100 of 124
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 299 - 305
1 Mar 2008
Kim Y

This study reviewed the results of a cementless anatomical femoral component to give immediate post-operative stability, and with a narrow distal section in order not to contact the femoral cortex in the diaphysis, ensuring exclusively metaphyseal loading.

A total of 471 patients (601 hips) who had a total hip replacement between March 1995 and February 2002 were included in the study. There were 297 men and 174 women. The mean age at the time of operation was 52.7 years (28 to 63). Clinical and radiological evaluation were performed at each follow-up. Bone densitometry was carried out on all patients two weeks after operation and at the final follow-up examination. The mean follow-up was 8.8 years (5 to 12).

The mean pre-operative Harris hip score was 41 points (16 to 54), which improved to a mean of 96 (68 to 100) at the final follow-up. No patient complained of thigh pain at any stage. No acetabular or femoral osteolysis was observed and no hip required revision for aseptic loosening of either component. Deep infection occurred in two hips (0.3%) which required revision. One hip (0.2%) required revision of the acetabular component for recurrent dislocation. Bone mineral densitometry revealed a minimal bone loss in the proximal femur.

This cementless anatomical femoral component with metaphyseal loading but without distal fixation produced satisfactory fixation and encourages proximal femoral loading.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1317 - 1323
1 Oct 2007
Kim Y Yoon S Kim J

We compared the results of 146 patients who received an anatomic modular knee fixed-bearing total knee replacement (TKR) in one knee and a low contact stress rotating platform mobile-bearing TKR in the other. There were 138 women and eight men with a mean age of 69.8 years (42 to 80). The mean follow-up was 13.2 years (11.0 to 14.5). The patients were assessed clinically and radiologically using the rating systems of the Hospital for Special Surgery and the Knee Society at three months, six months, one year, and annually thereafter.

The assessment scores of both rating systems pre-operatively and at the final review did not show any statistically significant differences between the two designs of implant. In the anatomic modular knee group, one knee was revised because of aseptic loosening of the tibial component and one because of infection. In addition, three knees were revised because of wear of the polyethylene tibial bearing. In the low contact stress group, two knees were revised because of instability requiring exchange of the polyethylene insert and one because of infection.

The radiological analysis found no statistical difference in the incidence of radiolucent lines at the final review (Student’s t-test, p = 0.08), most of which occurred at tibial zone 1. The Kaplan-Meier survivorship for aseptic loosening of the anatomic modular knee and the low contact stress implants at 14.5 years was 99% and 100%, respectively, with a 95% confidence interval of 94% to 100% for both designs.

We found no evidence of the superiority of one design over the other at long-term follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 904 - 910
1 Jul 2007
Kim Y Kim D Kim J

We conducted a randomised prospective study to evaluate the clinical and radiological results of a mobile- and fixed-bearing total knee replacement of similar design in 174 patients who had bilateral simultaneous knee replacement. The mean follow-up was for 5.6 years (5.2 to 6.1).

The total knee score, pain score, functional score and range of movement were not statistically different (p > 0.05) between the two groups. Osteolysis was not seen in any knee in either group. Two knees (1%) in the mobile-bearing group required revision because of infection; none in the fixed-bearing group needed revision. Excellent results can be achieved with both mobile- and fixed-bearing prostheses of similar design at mid-term follow-up. We could demonstrate no significant clinical advantage for a mobile bearing.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 467 - 470
1 Apr 2007
Kim Y Kim J Kim D

We performed a prospective, randomised study to compare the results and rates of complications of primary total knee replacement performed using a quadriceps-sparing technique or a standard arthrotomy in 120 patients who had bilateral total knee replacements carried out under the same anaesthetic. The clinical results, pain scales, surgical and hospital data, post-operative complications and radiological results were compared.

No significant differences were found between the two groups with respect to the blood loss, knee score, function score, pain scale, range of movement or radiological findings. In contrast, the operating time (p = 0.0001) and the tourniquet time (p < 0.0001) were significantly longer in the quadriceps-sparing group, as was the rate of complications (p = 0.0468).

We therefore recommend the use of a standard arthrotomy with the shortest possible skin incision for total knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 471 - 476
1 Apr 2007
Kim Y Kim J Yoon S

Bilateral sequential total knee replacement was carried out under one anaesthetic in 100 patients. One knee was replaced using a CT-free computer-assisted navigation system and the other conventionally without navigation. The two methods were compared for accuracy of orientation and alignment of the components. There were 85 women and 15 men with a mean age of 67.6 years (54 to 83). Radiological and CT imaging was carried out to determine the alignment of the components. The mean follow-up was 2.3 years (2 to 3).

The operating and tourniquet times were significantly longer in the navigation group (p < 0.001). There were no significant pre- or post-operative differences between the knee scores of the two groups (p = 0.288 and p = 0.429, respectively). The results of imaging and the number of outliers for all radiological parameters were not statistically different (p = 0.109 to p = 0.920).

In this series computer-assisted navigated total knee replacement did not result in more accurate orientation and alignment of the components than that achieved by conventional total knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 449 - 454
1 Apr 2007
Kim Y Kim J Yoon S

We studied prospectively the long-term results of the Charnley Elite-Plus femoral stem in 184 consecutive young patients (194 hips). There were 130 men and 54 women with a mean age of 49.1 years (21 to 60). The predominant diagnosis was osteonecrosis of the femoral head (63.6%, 117 patients). Clinical and radiological evaluation was undertaken at each follow-up. The mean follow-up was 11.2 years (10 to 12).

The mean pre-operative Harris hip score was 43.4 (12 to 49) which improved to 91 (59 to 100) at the final follow-up. The survival of the femoral stem at 12 years was 99% with revision as the end-point. The mean annual linear wear of the polyethylene liner was 0.17 mm (0.13 to 0.22). The prevalence of acetabular osteolysis was 10.8% (21 hips) and osteolysis of the calcar femorale 12.9% (25 hips).

A third-generation cementing technique, accurate alignment of the stem and the use of a 22 mm zirconia head were important factors in the prevention of aseptic loosening of the Elite Plus femoral stem in these high-risk young patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 174 - 179
1 Feb 2007
Kim Y Yoon S Kim J

Our aim in this prospective study was to compare the bone mineral density (BMD) around cementless acetabular and femoral components which were identical in geometry and had the same alumina modular femoral head, but differed in regard to the material of the acetabular liners (alumina ceramic or polyethylene) in 50 patients (100 hips) who had undergone bilateral simultaneous primary total hip replacement. Dual energy X-ray absorptiometry scans of the pelvis and proximal femur were obtained at one week, at one year, and annually thereafter during the five-year period of the study.

At the final follow-up, the mean BMD had increased significantly in each group in acetabular zone I of DeLee and Charnley (20% (15% to 26%), p = 0.003), but had decreased in acetabular zone II (24% (18% to 36%) in the alumina group and 25% (17% to 31%) in the polyethylene group, p = 0.001). There was an increase in the mean BMD in zone III of 2% (0.8% to 3.2%) in the alumina group and 1% (0.6% to 2.2%) in the polyethylene group (p = 0.315). There was a decrease in the mean BMD in the calcar region (femoral zone 7) of 15% (8% to 24%) in the alumina group and 14% (6% to 23%) in the polyethylene group (p < 0.001). The mean bone loss in femoral zone 1 of Gruen et al was 2% (1.1% to 3.1%) in the alumina group and 3% (1.3% to 4.3%) in the polyethylene group (p = 0.03), and in femoral zone 6, the mean bone loss was 15% (9% to 27%) in the alumina group and 14% (11% to 29%) in the polyethylene group compared with baseline values. There was an increase in the mean BMD on the final scans in femoral zones 2 (p = 0.04), 3 (p = 0.04), 4 (p = 0.12) and 5 (p = 0.049) in both groups.

There was thus no significant difference in the bone remodelling of the acetabulum and femur five years after total hip replacement in those two groups where the only difference was in the acetabular liner.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 304 - 304
1 May 2006
Lee K Kim Y Im D Kim H
Full Access

Introduction: The purpose of this study was to evaluate the effectiveness of free vascularized fibular grafting (VFG) for the treatment of osteonecrosis of the femoral head.

Materials and Methods: We reviewed the results in a consecutive series of 115 hips (88 patients) who had undergone free VFG between July 1991 and February 1999. Among them, 46 hips (32 patients, 28 males and 4 females) were available with periodic follow-up of at least 5 years. The mean follow up period was 7.1 years (range, 5 to 13 years). An average age of patients was 37.6 years at the time of VFG. We performed survival analysis by the Kaplan-Meier method according to the stage, etiology, age of patients, size of involvement, and degree of collapse of the femoral head. We used the Harris hip score for clinical evaluation, and used plain radiographs and MRIs for radiological evaluation.

Results: The survival rates were 85% in Ficat stage 2a, 34.7% in stage 2b, and 76.2% in stage 3. Eleven hips were evaluated as failures of VFG of which 7 hips were converted to a prosthetic joint. Harris Hip Scores were 67.8 points preoperatively, and increased to 80.4 points postoperatively. Good or excellent results were found in 69.5% of hips clinically and 56.5% of the hips radiologically. Age and size of necrosis affected the postoperative Harris Hip Score significantly, but other factors did not.

Discussion: Free VFG for the early osteonecrosis of femoral head revealed satisfactory results with good survival of the joint and improvements in Harris Hip Scores.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 776 - 780
1 Jun 2005
Kim Y Kim S Kim S Park B Kim P Ihn J

We performed 114 consecutive primary total hip arthroplasties with a cementless expansion acetabular component in 101 patients for advanced osteonecrosis of the femoral head. The mean age of the patients at surgery was 51 years (36 to 62) and the mean length of follow-up was 110 months (84 to 129).

The mean pre-operative Harris hip score of 47 points improved to 93 points at final follow-up. The polyethylene liner was exchanged in two hips during this period and one broken acetabular component was revised. The mean linear wear rate of polyethylene was 0.07 mm/year and peri-acetabular osteolysis was seen in two hips (1.9%). Kaplan-Meier analysis indicated that the survival of the acetabular component without revision was 97.8% (95% confidence interval 0.956 to 1.000) at ten years.

Our study has shown that the results of THA with a cementless expansion acetabular component and an alumina-polyethylene bearing surface are good.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 623 - 627
1 May 2005
Kim Y

Between January 1984 and January 1986, 131 porous-coated anatomic total hip replacements were performed in 119 consecutive patients. Of these, 100 patients (110 hips) who were alive at a minimum of 18 years after replacement were included in the study. The mean age of the patients at surgery was 48.4 years and that of surviving patients at the latest follow-up was 67.8 years. The mean duration of the clinical and radiological follow-up was 19.4 years (18 to 20).

The mean Harris hip score initially improved from 55 points before to 95 points at two years after operation, but subsequently decreased to 91 points after six years, 87 points after 11.2 years, and 85 points after 19.4 years. At the final follow-up, 23 hips (18%) of the entire cohort and 21% of survivors had undergone revision because of loosening or osteolysis of the acetabular component and eight hips (6%) of the entire cohort and 7% of survivors for loosening or osteolysis of the femoral component. Only four femoral components (4%) were revised for isolated aseptic loosening without osteolysis and two (2%) for recurrent dislocation. On the basis of these long-term results, the porous-coated anatomic femoral component survived for a minimum of 18 years after operation while the acetabular component was less durable. The findings identify the principles of uncemented joint replacement which can be applied to current practice.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 544 - 547
1 Apr 2005
Katz DA Kim Y Millis MB

We treated eight dysplastic acetabula in six skeletally mature patients with Down’s syndrome by a modified Bernese periacetabular osteotomy. The mean age at the time of surgery was 16.5 years (12.8 to 28.5). Mean length of follow-up was five years (2 to 10.4).

Pre-operatively the mean (Tönnis) acetabular angle was 28°, the centre-edge angle was −9°, and the extrusion index was 60%; post-operatively they were 3°, 37°, and 17%, respectively. Two patients with post-operative (Tönnis) acetabular angles > 10° developed subluxation post-operatively and required secondary varus derotation femoral osteotomies. Another patient developed a late labral tear which was treated arthroscopically. All eight hips remain clinically stable, and are either asymptomatic or symptomatically improved.

These results suggest that the modified Bernese periacetabular osteotomy can be used successfully in the treatment of acetabular dysplasia in patients with Down’s syndrome.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 621 - 621
1 May 2004
KIM Y


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 412 - 413
1 Apr 2004
Kim Y
Full Access

One hundred twenty eight revision hip arthroplasties performed before Dec. 1995 using the Wagner self locking prosthesis were followed for five to ten years. Obviously, the shape of this revision prosthesis complements optimal primary stability; however, one must pay attention not to undersize the stem. Hence, the most significant feature contributing to this self-locking type is the accomplishment of appropriate canal filling when revision with optimum anchorage length of prosthetic component. According to the clinical and radiological data obtained from our midterm results, we confirm the excellent validity of this system for treating the advanced cases of bone resorption for revision. Obviously the classification based on the femoral bone deficiency by the AAOS and DGOT are well documented. Even though we agree with the recent concept of Bourne-Rorabeck that is worthwhile tending to revert to a simple, but practical classification based on the cancellous bone’s quality and the intactness of the cortical tube, we believe that four of Bourne-Rorabeck had better be five in order to be clearer. Furthermore, additional seven various cases series of recent for subsidence of the femoral components were included in this study.

We beieve that the only contraindication is conversion from arthrodesis when the patient has long standing history of heavy plate and screws because of undue discrepancy of the stress shielding. Lastly, it is very unusual, however, we describe the operative technique which Wagner stem is inevitably removed.


The purpose this prospective, randomized clinical trial was to determine if unilateral or bilateral simultaneous total hip arthroplasty procedures resulted in a differing incidence of fat embolization, degree of hemodynamic compromise, levels of hypoxemia or mental status changes. Also, the incidence of fat embolization was compared between the cemented and cementless total hip arthroplasty in the patients with a unilateral- and bilateral simultaneous total hip arthroplasty.

One hundred and fifty-six consecutive patients undergoing primary total hip arthroplasty were enrolled prospectively in the study after giving informed consent. The group consisted of fifty patients undergoing bilateral simultaneous total hip arthroplasty and 106 patients undergoing unilateral total hip arthroplasty. One hundred and three hips were cemented and 103 hips were cementless. To determine the hemodynamic changes and to detect the fat and bone marrow embolization, arterial and right atrial blood samples were obtained before implantation (baseline) and at one, three, five and ten minutes after implantation of the acetabular component. Also, arterial and right atrial blood samples were obtained at one, three, five and ten minutes after implantation of the femoral component. And then blood samples were obtained at twenty-four and forty-eight hours after the operation. Arterial blood pressure, right atrial pressure, arterial oxygen tension and carbon-dioxide tension were monitored at corresponding times. The presence of lipid was determined with oil red O fat stain and the presence of cellular contents of bone marrow was determined with Wright-Giemsa stain.

The incidence of fat embolism was not statistically different (P=1.000) between the patients with a bilateral total hip arthroplasty (twenty seven patients or 54 per cent) and the patients with a unilateral total hip arthroplasty (fifty-two patients or 49 per cent). In the semiquantitative analysis of fat globules in both groups, there was no tendency to have a higher number of fat globules in the bilateral group than in the unilateral group. Also, the incidence of bone marrow embolization was not statistically different (P=0.800) between the patients with a bilateral total hip arthroplasty (eight patients or 16 per cent) and the patients with a unilateral total hip arthroplasty (fourteen patients or 13 per cent). There was no statistical difference (P=0.800) in the incidence of the presence of fat globule between the cemented total hip (thirty-four patients or 34 per cent) and the cementless total hip arthroplasty (forty-seven patients or 44 per cent). Also, there was no statistical difference (P=0.627) in the incidence of the presence of bone marrow cells between the cemented total hip arthroplasty (thirteen patients or 13 per cent) and the cement-less total hip arthroplasty (twelve patients or 11 per cent). Four patients with positive bone marrow cells had neurological manifestation. All of these four patients developed diffuse encephalopathy with confusion and agitation for about twenty-four hours.

The present study confirmed that the incidence of fat and bone marrow embolization is similar in the patients with a bilateral simultaneous-and unilateral total hip arthroplasty as well as in the patients with cemented and cementless total hip arthroplasty. The patients with bone marrow cell emboli had a significantly lower arterial oxygen tension (p=0.022) and oxygen saturation (p=0.017) than the patients without bone marrow cell emboli. On the contrary, the number of fat globules did not affect the perioperative hemodynamic changes. Encephalopathy is related to the biochemical and/or mechanical changes by bone marrow cells.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 149 - 149
1 Feb 2004
Kim H Lee K Jeong C Moon C Kim Y
Full Access

Introduction: It is very important to evaluate the healing process in the femoral head after free vascularized fibular graft (VFG) in osteonecrosis of the femoral head (ONFH). Bone scintigraphy combined with a pinhole collimator, which is simple and not expensive, is used for very high resolution images of small organs, such as thyroid and certain skeletal regions. The purpose of this study was to assess the changes using pinhole bone scintigraphy in ONFH after VFG.

Materials and Methods: Changes of Tc-99m-HDP pinhole bone scintigraphy were analyzed in 22 cases of ONFH which were treated with VFG and had satisfactory results in patient evaluations at least 2 years after surgery. Harris Hip Scores were 90 points or more; and femoral head collapse was less than 2 mm.

Results: The results were: (1) At 1 week, the pinhole image showed no significant change in cold area but two linear RI uptakes corresponding to the fibular graft were noted. (2) At 3 months, localized hot uptakes just above the tip of the graft were observed in 17 cases (77.2%), and diffuse increased uptake surrounding the cold area were observed. (3) At 6 months, localized hot uptake were increased in size and replaced cold areas and delineated the shape of the superolateral aspect of the femoral head. (4) At 1 year, increased RI uptake of the superolateral aspect of the femoral head expanded medially in all cases. (5) After 2 years, cold areas faded away in 18 cases (81.8%).

Discussion: In conclusion, the authors believe that the Tc-99m-HDP pinhole bone scintigraphy is an excellent method to delineate the healing process in ONFH after VFG.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 145 - 146
1 Feb 2004
Kim Y Kim J
Full Access

Introduction: A potential cause of premature loosening of the total hip prosthesis in patients with osteonecrosis is abnormal cancellous bone in the acetabulum and proximal femur. The purpose of this prospective study was to investigate the hypothesis that osteonecrosis is not confined to the femoral head but may extend proximally into acetabulum and distally into the proximal femoral bone. Also, the clinical and radiographic results of total hip arthroplasty with so-called third-generation cementless total hip prostheses were evaluated in sixty-three consecutive patients with osteonecrosis of the femoral head.

Materials and Methods: Twenty-five patients who had simultaneous bilateral total hip arthroplasty, and thirty-eight patients who had a unilateral total hip arthroplasty were included in the study. A cementless acetabular and femoral component were used in all hips. There were fifty-five men and eight women. The mean age at the time of the arthroplasty was 47 years (range, twenty-five to sixty-four years). We performed histological examination of the femoral heads and cancellous bone biopsies from five regions of the hip in patients undergoing total hip arthroplasty. Clinical and radiographic evaluations were performed preoperatively; at six weeks; at three, six, and twelve months; and yearly thereafter. The average duration of follow-up was 4.9 years.

Results: The majority of patients with idiopathic or alcohol induced osteonecrosis had normal bone in the acetabulum and proximal femur. The average Harris hip scores in the group treated with unilateral arthroplasty (96 points) and the group treated with bilateral arthroplasty (94 points) were similar at the time of final follow-up. No component had aseptic loosening. In one hip (1%), an acetabular component and a femoral component were revised because of infection. No hip had detectable wear or osteolysis in the acetabulum or in the proximal femur.

Conclusions: Normal or nearly normal cancellous bone in the acetabulum and proximal femur and advancements in surgical technique and better designs have greatly improved the intermediate-term survival of cementless total hip implants in young patients with osteonecrosis of the femoral head. An absence of osteolysis in these high-risk young patients is partly related to use of ceramic-on-ceramic bearing; solid fixation of the component; and short-term follow-up.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 146 - 146
1 Feb 2004
Koo K Ha Y Kim H Yoo J Kim Y
Full Access

Introduction: The hypothesis that combined necrotic angle measurements using magnetic resonance imaging (MRI) scans predicts the subsequent risk of collapse of femoral head osteonecrosis was tested.

Materials and Methods: Thirty-seven hips with early-stage osteonecrosis in 33 consecutive patients were investigated. The arc of the necrosis was measured by the method of Kerboul et al using mid-coronal and mid-sagittal MRI scans of the femoral head instead of anteroposterior and lateral radiographs, and the two angles were added. Hips were classified into four categories based on the magnitude of the added angle; grade 1 (< 200°), grade 2 (200°–249°), grade 3 (250°–299°), and grade 4 (≥300°). After the initial evaluations, the hips were randomly assigned to a core-decompression group or conservatively-treated group. Patients underwent regular follow-up until femoral head collapse or for a minimum of five years.

Results: Seven hips in the grade 4 category and 16 hips in the grade 3 category developed femoral head collapse in 36 months; six out of nine hips in the grade 2 category, and none of five hips in the grade 1 category developed collapse (log rank test, p< 0.01). In a retrospective analysis, none of the four hips with a combined necrotic angle < 190° (low risk group) collapsed, whereas all 25 hips with a combined necrotic angle > 240° (high risk group) collapsed, and four (50%) of eight hips with a combined necrotic angle between 190° and 240° (moderate risk group) collapsed during the study.

Discussion: The Kerboul combined necrotic angle ascertained by MRI scans instead of radiographs is a major predictor of future collapse.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 151 - 152
1 Feb 2004
Kim Y Oh S Kim J Koo K
Full Access

Introduction: The rate of failure of primary total hip arthroplasty in patients with osteonecrosis of the femoral head is higher than in patients with osteoarthritis. The purpose of this prospective study was to document the clinical and radiographic results of arthroplasty with so-called third generation cementing and the results of second generation cementless total hip arthroplasty in ninety-eight consecutive patients with osteonecrosis of the femoral head.

Materials and Methods: Fifty patients who had simultaneous bilateral total hip arthroplasties with a cemented stem in one hip and a cementless stem in the other and forty-eight patients who had unilateral total hip arthroplasties with a cementless stem were included in the study. A cementless acetabular component was used in all hips. The presumed cause of the osteonecrosis was ethanol abuse in fifty-seven patients, unknown in twenty-seven, fracture of the femoral neck in nine, and steroid use in five. There were eighty men and eighteen women. The mean age the time of the arthroplasty was 47 years (range, twenty-six to fifty-eight years). Clinical and radiographic evaluations were performed preoperatively, at six weeks, at three, six, and twelve months; yearly thereafter. The average duration of follow-up was 9.3 years.

Results: The average Harris hip scores in the group treated with unilateral arthroplasty (97 points) and the group treated with bilateral arthroplasty (94 points) were similar at the time of final follow-up. They were also similar between the group treated with cement (mean, 96 points) and that treated without cement (95 points). No component had aseptic loosening in either group. In one hip, a cemented femoral stem (2 %) and a cementless cup were revised because of infection. Two cementless stems (2%) were revised because of fracture of the proximal part of the femur with loosening of the stem. Annual wear of the polyethylene liner averaged 0.22 mm in the group treated with cement (a zirconia head) and 0.14 mm in the group treated without cement (a cobalt-chrome head). The prevalence of osteolysis in zones 1 and 7 of femur was 16 % in the femur was 16% in the group treated with cement and 24% in the group treated without cement.

Discussion: Advances in surgical technique and better designs have greatly improved the long-term survival of cemented and cementless implants in young patients with osteonecrosis of femoral head. Although there was no aseptic loosening of the components, the high rate of linear wear of the polyethylene liner and high rate of osteolysis in these high risk young patients remain challenging problems.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 152 - 152
1 Feb 2004
Ha Y Koo K Kim H Yoo J Kim Y
Full Access

Introduction: Necrotic fatty marrow is yellow, thick, and turbid like pus and the fat cell is counted as white blood cell in automated cell counting. When necrotic fatty marrow leaks into the hip joint through a crack in the cartilage of the osteonecrotic femoral head, a misdiagnosis of pyogenic infection can be made. The authors report cases of osteonecrosis of the femoral head, in which a misdiagnosis of pyogenic infection was made during the operation.

Materials and Methods: Between September 1997 and December 2001, pyogenic arthritis was suspected during the operation in seven patients who were operated on due to advanced osteonecrosis of the femoral head. The markers of infection including white blood cell count, erythrocyte sedimentation rate, and C reactive protein in preoperative laboratory examination were normal in all of the seven patients. Total hip arthroplasty was scheduled for all patients. When the hip joint capsule was incised, joint fluid gushed out in all patients. The appearance, white blood cell count in automated cell counting, microscopic findings, and the results of culture of the joint fluid were evaluated.

Results: The joint fluid was yellow, thick and turbid like pus. A pyogenic arthritis was suspected and the joint fluid was sent to the laboratory for automated blood cell count, smear and culture. The count of white blood cells ranged from 5800 to 18000 in automated cell counting. No microorganism was identified on joint fluid smear. On microscopic cell counting using a hemocytometer, white blood cells were rarely seen and the majority of cells which were counted as white blood cells, were necrotic fat cell. Total hip arthroplasty was performed immediately after microscopic examination of the joint fluid. No microorganism was identified in cultures of the joint fluid. There was no evidence of infection after total hip arthroplasty at a minimum of two-year followup.

Discussion: When necrotic fatty marrow leaks into the hip joint, the joint fluid looks like pus and white blood cell counts of the joint fluid is increased in automated cell counting because fat cells are counted as white blood cells. In this situation, microscopic examination of the joint fluid is necessary. If the white blood cell count is not increased in microscopic cell counting, replacement arthroplasty can be performed without risk of infection.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 146 - 146
1 Feb 2004
Kim H Song W Yoo J Koo K Kim Y
Full Access

Introduction: Some patients with collapsed osteonecrosis of the femoral head do not need any specific treatment because of mild symptoms or disability. The general features of this patient population were evaluated.

Materials and Methods: Forty-five cases of collapsed osteonecrosis of the femoral head in 38 patients were included in this study. These patients visited outpatient clinics for the first time from January 1996 to December 2002. In all cases, pain developed at least 3 years before the last follow-up, but no specific treatment was necessary. There were 27 men and 11 women. The mean age at the onset of pain was 41 years (range, 17 to 72 years). The duration from the onset of pain to the last follow-up was 36 to 167 months (mean, 73 months). The general and radiological features were evaluated.

Results: Risk factors included steroid therapy in 18, alcoholism in 16, other in 1 case; 10 cases had no risk factors (idiopathic). In 29 patients, both femoral heads were involved. Extent of the necrosis was 37 to 89 percent (mean, 62 percent). The amount of depression was 0.5 to 17 mm (mean, 2.2 mm).

Discussion: Steroid therapy was the most frequent risk factor in this patient population. In most cases, the amount of depression was less than 3 mm. Most patients remembered that the pain was most severe at its onset and improved over the next several months.