Lengthening osteotomies of the calcaneus in children are in general
grafted with bone from the iliac crest. Artificial bone grafts have
been introduced, however, their structural and clinical durability
has not been documented. Radiostereometric analysis (RSA) is a very
accurate and precise method for measurements of rigid body movements including
the evaluation of joint implant and fracture stability, however,
RSA has not previously been used in clinical studies of calcaneal
osteotomies. We assessed the precision of RSA as a measurement tool
in a lateral calcaneal lengthening osteotomy (LCLO). LCLO was performed in six fixed adult cadaver feet. Tantalum
markers were inserted on each side of the osteotomy and in the cuboideum.
Lengthening was done with a plexiglas wedge. A total of 24 radiological
double examinations were obtained. Two feet were excluded due to
loose and poorly dispersed markers. Precision was assessed as systematic
bias and 95% repeatability limits.Objectives
Methods
We present the validation of a translation into
Danish of the Oxford ankle foot questionnaire (OxAFQ). We followed the
Isis Pros guidelines for translation and pilot-tested the questionnaire
on ten children and their parents. Following modifications we tested
the validity of the final questionnaire on 82 children (36 boys
and 45 girls) with a mean age of 11.7 years (5.5 to 16.0) and their
parents. We tested the reliability (repeatability (test–retest),
child–parent agreement, internal consistency), feasibility (response
rate, time to completion, floor and ceiling effects) and construct
validity. The generic child health questionnaire was used for comparison.
We found good internal consistency for the physical and the school
and play domains, but lower internal consistency for the emotional domain.
Overall, good repeatability was found within children and parents
as well as agreement between children and parents. The OxAFQ was
fast and easy to complete, but we observed a tendency towards ceiling
effects in the school and play and emotional domains. To our knowledge
this is the first independent validation of the OxAFQ in any language.
We found it valid and feasible for use in the clinic to assess the
impact on children’s lives of foot and/or ankle disorders. It is
a valuable research tool. Cite this article:
Permanent growth arrest of the longer bone is
an option in the treatment of minor leg-length discrepancies. The
use of a tension band plating technique to produce a temporary epiphysiodesis
is appealing as it avoids the need for accurate timing of the procedure
in relation to remaining growth. We performed an animal study to
establish if control of growth in a long bone is possible with tension
band plating. Animals (pigs) were randomised to temporary epiphysiodesis
on either the right or left tibia. Implants were removed after ten
weeks. Both tibiae were examined using MRI at baseline, and after
ten and 15 weeks. The median interphyseal distance was significantly shorter
on the treated tibiae after both ten weeks (p = 0.04) and 15 weeks
(p = 0.04). On T1-weighted images the metaphyseal water
content was significantly reduced after ten weeks on the treated
side (p = 0.04) but returned to values comparable with the untreated
side at 15 weeks (p = 0.14). Return of growth was observed in all
animals after removal of implants. Temporary epiphysiodesis can be obtained using tension band plating.
The technique is not yet in common clinical practice but might avoid
the need for the accurate timing of epiphysiodesis. Cite this article:
An increasing number of hip prostheses are inserted without bone cement. Experimental research has shown that hydroxyapatite (HA) coated implants are strongly fixated in the bone, which is believed to reduce the likelihood of prosthetic loosening. However, in recent years, there has been much debate about the role of HA particles in third-body polyethylene (PE) wear and formerly we have shown the revision rate to be high among older-design HA coated cups. We hypothesized increased PE wear-rate using HA coated acetabular components in comparison with non-HA coated components (control group).Background
Purpose
Chronic radial head dislocation in children after trauma is a serious condition. Often the dislocation is overseen initially and is a part of the Monteggia fracture complex with anterior bowing of the ulna. Typical complaints are pain, decreased ROM and cubitus valgus. Radial head dysplasia often occurs. The treatment of this condition is debated. Only few series of patients treated with open reduction and ulnar osteotomy exists with long-term follow up. We present a group of rare patients with long-time follow-up treated by only two surgeons through a period of 16 years. All 16 patients had anterior radial head dislocation (Bado type 1). Mean age at the time of traumatic dislocation was 6 years ranging from 2 to 9. We found a mean delay of 17 (range 1–83) months before open reduction and ulnar open wedge osteotomy. In 8 cases reconstruction of the annular ligament was performed and in 6 patients temporary transarticular fixation of the radial head with a k-wire was performed. Follow-up time was 8 (range 3–17) years postoperatively. Patients were investigated with bilateral x-ray, arthrosis status, congruency of the radiocapitellar joint, Oxford Elbow Score, force measurements and range of motion.Introduction
Materials and Methods
The accuracy and precision of two new methods of model-based
radiostereometric analysis (RSA) were hypothesised to be superior
to a plain radiograph method in the assessment of polyethylene (PE)
wear. A phantom device was constructed to simulate three-dimensional
(3D) PE wear. Images were obtained consecutively for each simulated
wear position for each modality. Three commercially available packages
were evaluated: model-based RSA using laser-scanned cup models (MB-RSA),
model-based RSA using computer-generated elementary geometrical
shape models (EGS-RSA), and PolyWare. Precision (95% repeatability
limits) and accuracy (Root Mean Square Errors) for two-dimensional
(2D) and 3D wear measurements were assessed.Objectives
Methods
Impacted bone allograft is often used in revision joint replacement. Hydroxyapatite granules have been suggested as a substitute or to enhance morcellised bone allograft. We hypothesised that adding osteogenic protein-1 to a composite of bone allograft and non-resorbable hydroxyapatite granules (ProOsteon) would improve the incorporation of bone and implant fixation. We also compared the response to using ProOsteon alone against bone allograft used in isolation. We implanted two non-weight-bearing hydroxyapatite-coated implants into each proximal humerus of six dogs, with each implant surrounded by a concentric 3 mm gap. These gaps were randomly allocated to four different procedures in each dog: 1) bone allograft used on its own; 2) ProOsteon used on its own; 3) allograft and ProOsteon used together; or 4) allograft and ProOsteon with the addition of osteogenic protein-1. After three weeks osteogenic protein-1 increased bone formation and the energy absorption of implants grafted with allograft and ProOsteon. A composite of allograft, ProOsteon and osteogenic protein-1 was comparable, but not superior to, allograft used on its own. ProOsteon alone cannot be recommended as a substitute for allograft around non-cemented implants, but should be used to extend the volume of the graft, preferably with the addition of a growth factor.
We have studied the beneficial effects of a hydroxyapatite (HA) coating on the prevention of the migration of wear debris along the implant-bone interface. We implanted a loaded HA-coated implant and a non-coated grit-blasted titanium alloy (Ti) implant in each distal femoral condyle of eight Labrador dogs. The test implant was surrounded by a gap communicating with the joint space and allowing access of joint fluid to the implant-bone interface. We injected polyethylene (PE) particles into the right knee three weeks after surgery and repeated this weekly for the following five weeks. The left knee received sham injections. The animals were killed eight weeks after surgery. Specimens from the implant-bone interface were examined under plain and polarised light. Only a few particles were found around HA-coated implants, but around Ti implants there was a large amount of particles. HA-coated implants had approximately 35% bone ingrowth, whereas Ti implants had virtually no bone ingrowth and were surrounded by a fibrous membrane. Our findings suggest that HA coating of implants is able to inhibit peri-implant migration of PE particles by creating a seal of tightly-bonded bone on the surface of the implant.