header advert
Results 21 - 32 of 32
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 130 - 130
1 May 2016
Kweon S Kim T Kim J Jeong K
Full Access

Purpose

The purpose of this study is to evaluate the clinical outcomes and and radiological findings of primary total hip arthroplasty(THA) performed by using cemented polished femoral stem.

Materials and Methods

We retrospectively reviewed 91 hips (84 patients) that had undergone primary THA with cemented polished femoral stem after follow-up more than 10 years. The mean age at surgery was 57 years old (47 to 75). Mean follow up period was 12. 8 years(10.1 to 14). Clinical evaluation was performed using Harris hip score. The radiographic evaluation was performed in terms of the cementing technique, including of subsidence within the cement mantle, radiolucent lines at the cement-bone or cement-stem interface, cortical hypertrophy, and calcar resorption.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 77 - 77
1 Jan 2016
Cho S Youm Y Kim J
Full Access

Purpose

To evaluate the effectiveness of post-operative pain management using the intra-operative peri-articular injection(PAI) and/or electromyography (EMG)-guided preoperative femoral nerve block (FNB) in total knee arthroplasty(TKA).

Materials and Methods

From March 2013 to February 2014, 90 knees which underwent primary TKA by one surgeon were included in our study. The patients were classified into three groups; a single injection FNB with an EMG guide (Group I, 30 knees), intra-operative PAI (Group II, 30 knees) and both FNB and PAI (Group III, 30 knees). Pain at rest and moving was evaluated by Visual Analogue Scale (VAS) at postoperative 0, 4, 8, 24 and 48 hours. Postoperative range of motion, time to walking, total blood loss, amount of opioid consumption and complications were compared in each group.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 148 - 148
1 Jan 2016
Cho S Youm Y Kim J
Full Access

Purpose

To measure the vitamin D level of the patients who received total knee arthroplasty (TKA) and evaluate the effect of vitamin D level on the results of TKA.

Materials and Methods

From February 2012 to January 2013, 151 female patients (204 knees) who underwent primary TKA by one surgeon were included in our study. Preoperative vitamin D level was measured and analyzed the relationship between that and preoperative Visual Analogue Scale (VAS), and Knee Society Knee Score (KS) and Function Score (FS). Thirty-nine patients (39 knees) who received unilateral TKA and could be followed up more than 1 year after operation were evaluated for the relationship between vitamin D level and postoperative VAS, KS and FS, and Western Ontario and McMaster Universities Arthritis Index (WOMAC) score.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 79 - 79
1 Jan 2016
Cho S Youm Y Kim J
Full Access

Purpose

The NexGen® legacy posterior stabilized (LPS)-Flex total knee system (Zimmer, Warsaw, IN) is designed to provide 150° of flexion following total knee arthroplasty (TKA). But, recent reports found a high incidence of loosening of the femoral component related to the deep flexion provided. We evaluated 9- to 12-year clinical and radiological follow-up results after NexGen® LPS-Flex TKA.

Materials and Methods

A retrospective evaluation was undertaken of 209 knees in 160 patients (21 males, 139 females) who were followed up for more than 9 years after Nexgen®LPS-Flex TKA. Evaluations included preoperative and postoperative range of motion(ROM), Knee Society(KS) knee score, function scores, tibiofemoral angle and assessment of postoperative complications.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 104 - 104
1 Jan 2016
Cho S Youm Y Kim J
Full Access

Purpose

The purpose of this study was to compare the clinical and radiological results after total knee arthroplasty(TKA) with PCL sacrificing (PCS) Medial Pivot Knee (MPK) and PCL Substituting (PS) Nexgen® LPS.

Materials and Methods

One hundred twenty knees in 80 patients after TKA with PCS ADVANCE® MPK (Group I) and 116 knees in 85 patients with PS Nexgen® LPS (Group II) were retrospectively evaluated. All the patients were followed up for more than 6 years. The evaluations included preoperative and postoperative range of motion (ROM), tibiofemoral angle, Knee Society (KS) knee and function score, Hospital for Special Surgery (HSS) knee score, WOMAC score and postoperative complications.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 221 - 221
1 Mar 2013
Cho H Kim J
Full Access

Purpose

To evaluate outcome after cementless bipolar hemiarthroplasties using a standard(tapered, rectangular) stem for the treatment of above type A2 fractures in elderly patients.

Material and methods

We reviewed the records of 37 patients who underwent bipolar hemiarthroplasty between February 2006 and Feburuary 2010 in our hospital who were followed for more than two years after surgery. The mean patient age was 73.5 years old (range 64∼88 years old). 16 patients were men, and 21 patients were women. We evaluated the results by analyzing operation time, amount of bleeding, recovery of walking ability, complications and radiologic findings.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 39 - 39
1 Mar 2013
Chung PH Kang S Kim J Kim YS Lee HM
Full Access

A seventy-five-year-old female patient presented with pain and deformity of her left leg of three days duration. Hybrid THRA has been done 11 years ago at her left hip for the treatment of osteoarthritis. Massive osteolysis and pathologic fracture were observed on plain radiograph (Fig. 1). Revision THRA using an allograft prosthesis composite (APC) was planned for solution of extensive bone loss of the proximal femur. Surgical exposure was performed through extended trochanteric osteotomy with the patient supine. Step-cut osteotomy was done at the remained proximal part of host femur to make match with the distal part of APC. Meticulous removal of granulation tissues and remaining cement was done. As Acetabular cup was stable, 60 mm sized high-walled polyethylene liner was exchanged. Calcar reconstruction prosthesis was cemented into a proximal femoral allograft measuring 15 cm and cement at the vicinity of the step-cut osteotomy was removed for later bony union at interface. After solid fixation of APC with cement, the distal half of APC was cemented with the host femur. Step-cut osteotomy was wired and autogenous bone grafts from the greater trochanter were added at the interface. Leg length and stability were rechecked using a standard necked 28 mm metal head and reduction was done stably. Greater trochanter was fixed over the trimmed proximal allograft with multiple wiring and paper-thin host femur was enveloped around the femoral allograft using absorbable sutures. Following insertion of the closed suction drainage drains, closure was done as routine fashion and healing of the wound was uneventful (Fig. 2). An abduction brace was applied post operatively for a period of four weeks. Crutch walking with partial weight bearing was started at four weeks and crutch protection was applied for a period of six months. Incorporation of allograft with the host bone was observed on two-year follow-up radiographs. At seven-year follow-up, the patient walks well with a mild limp, and Harris score is 90. We report on a seven-year follow-up case of revision THRA with APC with references (Fig. 3).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 220 - 220
1 Mar 2013
Cho H Kim J
Full Access

Purpose

To analyze the effectiveness of a vancomycin impregnated calcium sulfate cement bead insertion after debridement (of) an acute-immediate stage infected hip arthroplasty.

Materials and Methods

Between 2002 and 2008, 13 patients with documented acute-immediate stage infection of hip arthroplasty were reviewed and followed for at least two years postoperatively(average 4.3 years). The preoperative and postoperative clinical and radiologic findings and blood laboratory work were checked. All cases were performed through retention of the implant and massive debridement and saline irrigation. After that a vancomycin impregnated calcium sulfate cement beads was inserted.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 35 - 35
1 Mar 2013
Cho H Kim J
Full Access

Recent reports about the excellent clinical results of unicondylar knee arthroplasty (UKA; also known as unicompartmental knee arthroplasty), by the minimally invasive approach, have encouraged the adoption of the surgical technique. However, friction between metallic prosthetic components resulting from polyethylene wear may result in the development of metallosis and the use of metal implants has become a huge issue in the worlds recently. Here, we report a case in which a patient underwent UKA and developed metallosis in soft tissues and bone adjacent to an implanted artificial joint three years postoperatively.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 222 - 222
1 Mar 2013
Kim J Chung PH Kang S Kim YS Lee HM
Full Access

The posterior-stabilized knee prosthesis is designed specifically to provide the posterior stability to a knee arthroplasty when PCL is deficient or has to be sacrificed. Posterior dislocation of such prosthesis is rare but dreaded complication. There are several causes of postoperative dislocation such as malposition of the prosthesis, preoperative valgus deformity, a defect of the extensor mechanism and overwidening of the flexion gap. Posterior-stabilized rotating-platform mobile-bearing knee implants have been widely used to further improve the postoperative range of motion by incorporation of the post and cam mechanism to improve the posterior roll back during flexion and to overcome the wear and osteolysis problems due to significant undersurface micromotion of posterior-stabilized fixed-bearing knees. But, spin-out or rotatory dislocation of the polyethylene insert can occurs as result of excessive rotation of the rotating platform accompanied by translation of the femur on the tibia after mobile-bearing total knee arthroplasty, but that is very rare. Here, authors describe an unusual case of acute 180° rotatory dislocation of the rotating platform after posterior dislocation of a posterior-stabilized mobile-bearing total knee arthroplasty.

A 71-year-old male with knee osteoarthritis underwent a TKRA using posterior-stabilized mobile-bearing prosthesis. The posterior dislocation of the total knee arthroplasty occurred 5 weeks postoperatively(Fig. 1). We underwent closed reduction of posterior dislocated total knee arthroplasty resulting in a complete 180° rotatory dislocation of the rotating platform (Fig. 2). He was treated with open exploration and polyethylene exchange with a larger component.

This case illustrates that dislocation of a posterior-stabilized mobile-bearing total knee arthroplasty can occur with valgus laxity, cause 90° spin-out of the polyethylene insert and closed reduction attempts may contribute to complete 180° rotatory dislocation of the rotating platform. Special attention needs to be paid to both AP and lateral view to ensure that the platform is truly reduced and not just rotated 180° as was in this case.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 212 - 212
1 Sep 2012
Walker P Kahn H Zuckerman J Slover J Jaffe F Karia R Kim J
Full Access

INTRODUCTION

Total Knee Arthroplasty (TKA) is a durable procedure which allows most patients to achieve a satisfactory functional level, but there can be instability under stressful conditions. Instability is one cause of early revision, often due to misalignment or inadequate ligament balancing. Persistent instability may cause elevated polyethylene wear. Lower levels of instability may cause patient discomfort with certain stressful activities. Hence quantifying instability may have an important role in the functional evaluation of TKA. Several previous studies showed that accelerometers have advantages in kinematic studies including low cost, ease of application, and application to any activity. The aim of this study was to demonstrate the use of an accelerometer attached to the anterior of the tibia, as an evaluation of knee stability of TKA patients. It was postulated that accelerations between TKAs and normal controls will be different, which could indicate abnormal TKA kinematics involving instability, especially for high intensity activities.

METHODS & MATERIALS

We tested 38 TKA knees in 27 patients, in the age range of 50–80 years, with a minimum follow up of 6 months; and 25 knees in 16 shoulder patients, who had no known knee pathology as age-matched controls. A tri-axial accelerometer was firmly attached to the anterior proximal tibia to measure 3-axis accelerations with a sample rate of 100 Hz. Four activities were tested;

Starting with the test leg, walk 3 steps then come to a sudden stop

Take one step forward with the non-tested leg and make a tight 90∗∗∗∗∗ turn towards the non- tested knee direction

Sit down for 3–4 seconds then stand back up

Step up on a 7″ inches high box with the test leg, followed by the non-test leg. Then step down from the box with the test leg, followed by the non-test leg.

During the activities, the patients responded to a questionnaire on instability and pain for each activity. For each test at the time of foot impact, there was a high/low peak acceleration, the peak-to-valley being taken as the indicator. The mean total magnitude of the acceleration was compared between the TKA and control groups in the anterior-posterior direction using the Student's t-test. Statistical significance was at p-value < 0.05.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1394 - 1399
1 Oct 2009
Oh C Song H Kim J Choi J Min W Park B

Ten patients, who were unsuitable for limb lengthening over an intramedullary nail, underwent lengthening with a submuscular locking plate. Their mean age at operation was 18.5 years (11 to 40). After fixing a locking plate submuscularly on the proximal segment, an external fixator was applied to lengthen the bone after corticotomy. Lengthening was at 1 mm/day and on reaching the target length, three or four screws were placed in the plate in the distal segment and the external fixator was removed. All patients achieved the pre-operative target length at a mean of 4.0 cm (3.2 to 5.5). The mean duration of external fixation was 61.6 days (45 to 113) and the mean external fixation index was 15.1 days/cm (13.2 to 20.5), which was less than one-third of the mean healing index (48 days/cm (41.3 to 55). There were only minor complications.

Lengthening with a submuscular locking plate can successfully permit early removal of the fixator with fewer complications and is a useful alternative in children or when nailing is difficult.