header advert
Results 51 - 73 of 73
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 677 - 679
1 May 2008
Pan H Kawanabe K Akiyama H Goto K Onishi E Nakamura T

A 30-year-old man presented with pain and limitation of movement of the right hip. The symptoms had failed to respond to conservative treatment. Radiographs and CT scans revealed evidence of impingement between the femoral head-neck junction and an abnormally large anterior inferior iliac spine. Resection of the hypertrophic anterior inferior iliac spine was performed which produced full painless restoration of function of the hip.

Hypertrophy of the anterior inferior iliac spine as a cause of femoro-acetabular impingement has not previously been described.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 178 - 178
1 Mar 2008
Nakamura T Ito H Atsuta Y Tanino H Nishimura I Shimizu R Ishida T Mitamura Y Matsuno T
Full Access

Thigh pain appears often after THA used of the cement-less femoral components, but the appearance mechanism of thigh pain does not have been elucidated. As one factor of manifestation of thigh pain, it has been guessed that the pressure from the inside of medullary cavity of bone by the stem. The purpose of this study is confirming whether the flexor reflex is caused, by using the femur of a rabbit that applied the pressure from the inside of medullary cavity of bone.

Japanese white rabbits with weight of about 3kg were used. Evaluation of the appearance of the pain by the pressure was performed by measurement of the hind leg flexor activity produced by the flexor reflex. After confirming that appearance of the muscles activity by the pain reflex from adding the pain stimulus to the hind leg skin of rabbits, we loaded of the pressure into the inside of medullary cavity of bone and observed whether the muscles activity appears. As the laboratory animals model, we prepared two kinds of rabbits by the difference in the amount of reaming. And we tested how the differences show up between these two kinds of rabbits.

In the rabbits with few amounts of reaming, the flexor reflex appeared in low pressure. But, in the rabbits with many amounts of reaming, the flexor reflex did not appear in high pressure, either.

It is known that the somatic sensory nerves are distributed in the bone, and it is known that the sensory nerve ends exist in the medullary cavity of bone. It was suggested that the pain is induced, when the sensory nerve ends remained in the inside of medullary cavity of bone and the pressure in whicha reaction is possible was carried out there.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 169 - 169
1 Mar 2008
Ito H Matsuno T Nakamura T Minami A
Full Access

We evaluated intermediate-term results of primary cementless Omniflex prostheses.

Forty-nine patients (57 hips) with a mean age of 44 years were observed for an average of 8.6 years.

These results were inferior to those using other recent cementless total hip systems. The increasing prevalence of loosening and osteolysis with time are problems related to this Omniflex femoral component. Although the implant design is unique, the authors no longer use this system.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 187 - 187
1 Mar 2008
Tamura J Kawanabe K Shimizu M Ohnishi E Nakamura T
Full Access

We have developed bioactive bone cements manufactured from bioactive glass-ceramic powder and BIS-GMA resin, which has the bone-bonding ability. In the present clinical trial, this bioactive bone cement was used for fixation of total hip arthroplasty (THA) and the clinical results were investigated

Two types of bioactive bone cements (high- and low- viscosity type cements) were prepared (Nippon Electric Glass Co. Ltd.). Inorganic filler contained 72.0 wt% AW-GC (apatite and wollastonite containing glass-ceramic) and 27.0 wt% SiO2 powder. All surgery was performed at Kyoto University Hospital between February and October 1996. 20primary THA (20 patients) were performed using bioactive bone cement as a clinical trial. The average age of the patients was 58 years. The average follow-up period was 6 years, 9 months. The diagnosis for 18 hips at the operation was osteoarthritis and 2 hips were rheumatoid arthritis. All sockets and one stem were fixed by bioactive cement, and all but one stem were fixed by PMMA cement. In all cases all polyethylene socket and titanium stem were used (14 KC type THA and 8 KMAX type THA). For the femoral head 22 mm diameter alumina head was used in all cases.

If the bone cement is bioactive and shows direct bonding with the bone, wear particles can’t enter the interface and thus prevention of loosening due to bone resorption would be expected. This cement demonstrated satisfactory clinical results, proving to be a promising material for implant fixation.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 177 - 178
1 Mar 2008
Nakamura T Liang B Ohnish D Ise K Kawanabe K
Full Access

Zirconia ceramic femoral head has better mechanical properties than those alumina head has. However, it is concerning whether the wear of UHMWPE against zirconia head is as low as that of alumina head. We compared polyethylene wears against 22.225mm alumina and zirconia heads in total hip arthroplasties (THA) occupied in our hospital.

Kobelco hip prostheses (Kobelco, Kobe, Japan) were used. Titanium alloy stem was cement-fixed and all-polyethylene acetabular components were articulated with alumina or zirconia femoral heads. In the cases from February 1996 to December 1998, 96 primary cemented total hip arthroplasties (THA) in 87 patients of osteoarthritis were observed with a minimum follow-up of five years. The clinical results were evaluated using JOA hip score (100 in normal hip). There were 46 hips with alumina heads and mean follow-up of 6.2 years, and 51 hips with zirconiaheads and mean follow-up of 5.2 years. Mean ages at operation were 58 years. For each patient, the initial postoperative and the latest anterior-posterior radiographs of the pelvis were selected. With the custom software Image-Pro Plus version 4.0, linear wear and volumetric wear were measured.

Clinical results of both heads showed no difference. Linear wear rate of alumina is 0.080±0.047mm/year, while it is 0.147±0.069mm/year for zirconia, significantly higher than alumina (p?0.0001). Volumetric wear rate of zirconia (42.499±20.233mm3/year) is also significantly higher than alumina (27.049±17.216mm3/year) (p?0.0001).

The low thermal conductivity of zirconia is thought to cause local high temperature, leading to the phase transformation and lower-temperature aging degeneration (LTAD) of zirconia head surface. In order to solve this problem, alumina-adding zirconia compound ceramics with lower phase transformation were developed. Hip simulator test revealed much lower wear rate of improved zirconia. This will be discussed.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 172 - 172
1 Mar 2008
Yagihashi K Nishimura I Ishida T Ito H Tanino H Nakamura T Matsuno T Mitamura Y
Full Access

Prosthetic impingement after THA is to different for the angle and shape of the implant. Purpose of this study is examine the range of motion(ROM) on a computer when angle and shape of the implant are changed.

The 3D implant models were created on a computer. The angle was measured in the flexion, extension, adduction direction byevery 0.1 degrees. There are three kinds of acetabular abduction angle, two kinds of acetabular anteversion angle and two kinds of femoral anteversion angle. There are three kinds of the radius of neck and the neck shaft angle. All 324 patterns of the above model were measured.

When the radius of neck decreased, the ROM increased in all cases. When the neck shaft angle decreased, the ROM increased by almost all cases. When the acetabular anteversion angle increased, the ROM of flexion direction increased and adduction direction decreased, and as for the extension direction, all the factors had influenced the change in the ROM. When the acetabular angle increased, the ROM of the extension direction increased and the flexion directions decreased. As for adduction direction, femoral anteversion angle, acetabular anteversion angles, and the radius of neck had influenced the ROM. When the femoral anteversion angle increased, the ROM of flexion direction increased and extension, adduction direction decreased.

The clinical ROM is affected by the impingement of non-implant and the strain of the soft tissue. Therefore, It’ s considered that the clinical ROM is smaller than the ROM which was investigated in this study in many cases. When the radius of neck and the neck shaft angle decrease, the increase of the ROM expected. However the radius of the neck should not be decreased too much to avoid the decrease of the neck strength.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 26 - 31
1 Jan 2007
Kawanabe K Akiyama H Onishi E Nakamura T

We retrospectively evaluated 42 hips which had undergone acetabular reconstruction using the Kerboull acetabular reinforcement device between September 1994 and December 1998. We used autogenous bone chips from the ilium and ceramic particle morsellised grafts, even in large acetabular bone defects, in the early stages of the study. Thereafter, femoral head allograft was used as bulk graft in patients with large acetabular defects. Ceramic blocks and the patients’ contralateral femoral head were also used as bulk graft. The mean follow-up period was 8.7 years (4.3 to 12).

Survivorship analysis was performed using radiological failure of the acetabular component, irrespective of whether it was revised, or not, as the end-point.

The survival rate of the morsellised graft group (25 hips) and the bulk graft group (17 hips) at ten years was 53% (95% confidence interval (CI) 42.5% to 63.5%) and 82% (95% CI 72.4% to 91.6%), respectively. The mid-term results of revision total hip replacement with the Kerboull device were better when bulk graft was used in any size of bone defect.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 62 - 65
1 Jan 2007
Ito H Matsumoto T Yoshitomi H Kakinoki R Nakamura T

We compared the outcome of peri-operative humeral condylar fractures in patients undergoing a Coonrad-Morrey semiconstrained total elbow replacement with that of patients with rheumatoid arthritis undergoing the same procedure without fractures. In a consecutive series of 40 elbows in 33 patients, 13 elbows had a fracture in either condyle peri-operatively, and 27 elbows were intact. The fractured condyle was either fixed internally or excised. We found no statistical difference in the patients’ background, such as age, length of follow-up, immobilisation period, Larsen’s radiological grade, or Steinbrocker’s stage and functional class. There was also no statistical difference between the groups in relation to the Mayo Elbow Performance Score, muscle strength, range of movement, or radiolucency around the implants at a mean of 4.8 years (1.1 to 8.0) follow-up.

We conclude that fractured condyles can be successfully treated with either internal fixation or excision, and cause no harmful effect.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 398 - 398
1 Apr 2004
Nishiguchi S Fujibayashi S Kim H Kokubo T Nakamura T
Full Access

In cementless fixation system, surface character becomes important factor. Alkali and heat treatments on titanium metal has been proved to show strong bonding to bone and higher ongrowth rate. In this study we examined the effect of alkali and heat treatments on titanium rod in rabbit femur intramedurally model, in consideration of cementless hip stem. The implant had a 5mm in diameter and 25 mm in length. The implants were and half of them were immersed in 5 mol/L sodium hydroxide solution and heated at 600 åé for one hour (AH implant), and the other half were untreated (CL implant). The implants were implanted into the distal femur of the rabbits, AH implant into left femur and CL implants into right. The bone-implant interfaces were evaluated at 3, 6, and 12 weeks after implantations.

Pull-out tests showed that AH implants significantly higher bonding strength to bone than CL implants at each week after operations. At 12 weeks mean pull-out load of AH implants was 411.7 N and that of CL implants 72.2 N. As postoperative time elapsed, histological examination revealed that new bone form on the surface of the both types of the implants, but significantly more bone contacted directly on the surface of AH implants. At 12 weeks AH implant was covered by the newly formed bone about 56% of the whole surface of the implants and CL implants was about 19%.

In conclusion, alkali- and heat-treated titanium offers strong bone-bonding and high affinity to bone instead of conventional mechanical interlocking mechanism. Alkali and heat treatments on titanium may be applicable to the surface treatment for cementless joint replacement implant.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 922 - 930
1 Aug 2003
Ushio K Oka† M Hyon S Yura S Toguchida J Nakamura T

The use of a composite osteochondral device for simulating partial hemiarthroplasty was examined. The device was composed of a polyvinyl alcohol hydrogel and a titanium fibre mesh, acting as artificial cartilage and as porous artificial bone, respectively. The titanium fibre mesh was designed to act as an interface material, allowing firm attachment to both the polyvinyl alcohol gel (through injection moulding) and the femoral joint surface (through bony ingrowth). We implanted 22 of these devices into canine femoral heads. Histological findings from the acetabular cartilage and synovial membrane, as well as the attachment of the prosthesis to bone, were examined up until one year after operation.

No marked pathological changes were found and firm attachment of the device to the underlying bone was confirmed. The main potential application for this device is for partial surface replacement of the femoral head after osteonecrosis. Other applications could include articular resurfacing and the replacement of intervertebral discs.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 734 - 735
1 Jul 2003
Kawanabe K Hayashi H Miyamoto M Tamura J Shimizu M Nakamura T

We present a case of septic arthritis of the hip caused by Candida albicans in a 24-year-old woman. This is the first report of a Candida infection of the hip in a patient without any predisposing factors. She underwent a two-stage total hip arthroplasty three years after the onset of the infection. An elevated plasma level of β-D-glucan suggested Candida as the infecting organism and the diagnosis might have been made earlier if this test had been undertaken at presentation.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 655 - 660
1 Jul 2003
Tanaka K Tamura J Kawanabe K Shimizu M Nakamura T

We examined the behaviour of alumina ceramic heads in 156 cemented total hip arthroplasties, at a minimum follow-up of eight years. They were divided into three groups according to the size of the femoral head; 22, 26, and 28 mm. We measured polyethylene wear radiologically using a computer-aided technique. The linear wear rate of polyethylene sockets for the 28 mm heads was high (0.156 mm/year), whereas those for the 22 and 26 mm heads were relatively low (0.090 and 0.098 mm/year, respectively). Moreover, the surface roughness data of retrieved femoral heads clearly showed maintenance of an excellent surface finish of the current alumina. We conclude that the alumina ceramic femoral heads currently used are associated with a reduced rate of polyethylene wear.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 34 - 34
1 Jan 2003
Iida H Matsusue Y Kawanabe K Nakamura T
Full Access

The results of 278 consecutive primary total hip arthroplasties performed with bone grafting for ace-tabular bone deficiencies were reviewed at an average of 9.0 years (range, 5–23) after surgery. All patients had underlying developmental dysplasia of the hip. For all hips, the grafts used were from the patients’ own resected femoral heads. All but three grafts were screwed to the supero-lateral aspect of the acetabular roof, the exceptions being grafts without internal fixation. Kaplan-Meier survivorship analysis predicted a rate of survival of the acetabular component at 10 years of 97% (95% confidence interval (CI), 94–100%) with revision for aseptic loosening as the endpoint, and of 82% (95% CI, 76–89%), when radiological loosening was used. Trabecular reorientation, as an indicator of graft incorporation, was seen in 89% of the joints between 1.5 and 5 years (mean 3 years), and delayed up to 7 years. Parametric survivorship analysis using the Cox proportional-hazards model indicated that trochanteric non-union, lateral placement of the socket, and delayed trabecular re-orientation of the bone graft, were risk factors for loosening of the acetabular component. Autogenous acetabular bone grafting will be of value for long-term success and has good potential for additional improvement of the results, provided these three risk factors are reduced. In order to promote the trabecular reorientation, we have gradually improved the surgical technique including sizing of bone graft and adaptation technique. By these alterations of the surgical technique, trabecular reorientation of the 51 joints operated after 1993 was completed by 4 years after surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 647 - 652
1 Jul 2002
Nishimatsu H Iida H Kawanabe K Tamura J Nakamura T

We evaluated the long-term results of a modified Spitzy shelf operation for secondary osteoarthritis in 119 hips with a mean follow-up of 23.8 years. The mean age of the patients at the time of surgery was 25 years. Preoperative osteoarthritic change, the age at operation and shelf height were important factors in determining the outcome. Of the 61 hips in the pre-stage (three) and the initial stage (58) of osteoarthritis, 53 (87%) had good results, compared with only 30 (51%) of 58 hips with advanced osteoarthritis. Of the latter, 72% of those aged less than 25 years had good results compared with only 40% of patients aged over 25 years. The shelf height in the group with good results was significantly lower than in those with poor results. This operation is a safe procedure and indicated for acetabular dysplasia or subluxation of the hip with early osteoarthritic change in patients aged less than 25 years.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 561 - 565
1 May 2002
Akagi M Kaneda E Nakamura T Ueno M Yamanashi W Miyajima H

The Bisurface knee prosthesis (BP) has a posterior stabilising cam (ball-and-socket joint) in the mid-posterior region of the femorotibial joint in an attempt to improve the range of movement. Based on an in vitro weight-bearing study contact areas of the Insall/Burstein 2 (IB2) and the BP knee were compared using pressure-sensitive films. The stability afforded by the cam was evaluated by means of dislocation distances in the vertical and horizontal planes.

Significant adverse anterior translation in mid-flexion was not observed with the BP knee since the cam was effective above 60° of flexion. At flexion of 60° or more, the total contact areas were larger, as the cam represented a weight-bearing surface. The dislocation distances for the BP knee compared favourably with those for the IB2 knee. We conclude that the cam of the BP knee allows good movement, stability and wear.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 431 - 432
1 Apr 2002
Iguchi Y Ihara N Hijioka A Uchida S Nakamura T Kikuta A Nakashima T

We describe the clinical features of calcifying tendonitis in the medial head of gastrocnemius in three elderly female patients. The presenting symptom was chronic pain in the posteromedial area of the knee in two patients and acute pain in the back of the knee in one. All had limitation of movement of the knee and marked tenderness in the region of the tendinous origin of the medial head of gastrocnemius with posterior knee pain induced by stretching the tendon. An injection of 1% lidocaine and steroid into the tendon resulted in temporary relief from pain and improved movement.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 614 - 618
1 May 2000
Fujita H Iida H Ido K Matsuda Y Oka M Nakamura T

We evaluated the efficacy and biocompatibility of porous apatite-wollastonite glass ceramic (AW-GC) as an intramedullary plug in total hip replacement (THR) for up to two years in 22 adult beagle dogs. Cylindrical porous AW-GC rods (70% porosity, mean pore size 200 3m) were prepared. Four dogs were killed at 1, 3, 6 and 12 months each and six at 24 months after implantation.

Radiological evaluation confirmed the efficacy of porous AW-CG as an intramedullary plug. Histological evaluation showed osteoconduction at one month and resorption of the porous AW-GC, which was replaced by newly-formed bone, at 24 months. Our findings indicate that porous AW-GC can be used clinically as an intramedullary plug in THR.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 176 - 184
1 Mar 2000
Iida H Matsusue Y Kawanabe K Okumura H Yamamuro T Nakamura T

Although the technique of autogenous acetabular bone grafting has been widely used to augment containment of the acetabulum in total hip arthroplasty (THA) for developmental dysplasia, the role of this technique in improving long-term results remains controversial.

We present the long-term results of cemented THA with acetabular bone grafting in 112 patients (133 hips) in order to clarify the factors which affect the outcome. The mean follow-up was for 12.3 years (8 to 24). Kaplan-Meier survivorship analysis predicted a rate of survival of the acetabular component at 15 years of 96% (95% confidence interval (CI) 92 to 99) with revision for aseptic loosening as the endpoint, and of 75% (95% CI 65 to 85) when radiological loosening was used. Parametric survivorship analysis using the Cox proportional-hazards model indicated that trochanteric nonunion, lateral placement of the socket, and delayed trabecular reorientation of the bone graft were risk factors for loosening of the acetabular component.

Our findings have shown that autologous acetabular bone grafting is of value for long-term success provided that the risk factors are reduced.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 527 - 530
1 May 1998
Kawanabe K Okada Y Matsusue Y Iida H Nakamura T

We have developed a new drug delivery system using porous apatite-wollastonite glass ceramic (A-W GC) to treat osteomyelitis. A-W GC (porosity, 70% and 20% to 30%), or porous hydroxyapatite (HA) blocks (porosity 35% to 48%) used as controls, were soaked in mixtures of two antibiotics, isepamicin sulphate (ISP) and cefmetazole (CMZ) under high vacuum.

We evaluated the release concentrations of the antibiotics from the blocks. The bactericidal concentration of ISP from A-W GC was maintained for more than 42 days, but that from HA decreased to below the detection limit after 28 days. The concentrations of CMZ from both materials were lower than those of ISP. An in vivo study using rabbit femora showed that an osseous concentration of ISP was maintained at eight weeks after implantation. Osteoconduction of the A-W GC block was good.

Four patients with infected hip arthroplasties and one with osteomyelitis of the tibia have been treated with the new delivery system with excellent results.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 1003 - 1007
1 Nov 1997
Oka M Chang Y Nakamura T Ushio K Toguchida J Gu H

We have studied damage to the tibial articular surface after replacement of the femoral surface in dogs. We inserted pairs of implants made of alumina, titanium and polyvinyl alcohol (PVA) hydrogel on titanium fibre mesh into the femoral condyles.

The two hard materials caused marked pathological changes in the articular cartilage and menisci, but the hydrogel composite replacement caused minimal damage. The composite osteochondral device became rapidly attached to host bone by ingrowth into the supporting mesh.

We discuss the clinical implications of the possible use of this material in articular resurfacing and joint replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 764 - 769
1 Sep 1997
Nakamura T Yabe Y Horiuchi Y Takayama S

We used magnetic resonance (MR) myelography in ten patients with injuries to the brachial plexus and compared the findings with those obtained by conventional myelography and postmyelographic CT (CTM). In the presence of complete nerve-root avulsion (seven cases), a post-traumatic meningocele was detected by MR myelography. In injuries to the upper roots (three cases) MR myelography showed abnormal findings with a high signal intensity in the nerve root, obliteration of the damaged nerve root, or enlargement and obliteration of the root sleeve. No pseudomeningoceles were detected in these upper-root injuries by MR myelography and CTM. The overall accuracy of detection of damaged nerve roots or root sleeves was better with MR myelography than with conventional myelography and was similar to that of CTM.

MR myelography is non-invasive, relatively quick, requires no contrast medium, provides imaging in multiple projections, and is comparable in diagnostic ability to the more invasive, time-consuming techniques of conventional myelography and CTM.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 26 - 31
1 Jan 1996
Senaha Y Nakamura T Tamura J Kawanabe K Iida H Yamamuro T

We have developed a bioactive bone cement (BA cement) consisting of Bis-GMA resin and bioactive glass powder. It has high compressive and tensile strengths, a low curing temperature and its bioactivity allows it to bond directly with bone.

We operated on the 18 femora of nine mongrel dogs for intercalary replacement of part of the bone by a metal prosthesis using either PMMA cement or BA cement for fixation. Three dogs were killed at each of 4, 12 and 26 weeks after surgery for the evaluation of fixation strength by a push-out test and for histological examination by Giemsa surface staining and SEM.

Fixation strengths with PMMA cement at 4, 12 and 26 weeks after surgery were 46.8 ± 18.9, 50.0 ± 24.7, and 58.2 ± 28.9 kgf (mean ±SD), respectively. Those with BA cement were 56.8 ± 26.1, 67.2 ± 19.2, and 72.8 ± 22.2 kgf, respectively. Fibrous tissue intervened between bone and PMMA cement but BA cement had bonded directly to bone at 12 and 26 weeks. This suggests that BA cement will be useful in providing long-lasting fixation of implants to bone under weight-bearing conditions.


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 3 | Pages 279 - 286
1 Aug 1977
Yoshikawa S Nakamura T Takagi M Imamura T Okano K Sasaki S

Two patients, a Japanese man and woman both aged eighteen, developed symptoms and signs of osteomalacia over a period of five years. Each of them had a benign osteoblastoma, one in the right fourth metacarpal and the other in the uppermost third of the right humerus. Resection of the tumours without any treatment by vitamin D resulted in rapid cure of the osteomalacia. Attempts to prove a phosphaturic humoral substance or vitamin D antagonist in the osteoblastoma of the humerus were unsuccessful, probably due to prompt excretion from the tumour cells.