header advert
Results 21 - 30 of 30
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 11 - 11
1 Mar 2021
Wong M Wiens C Kooner S Buckley R Duffy P Korley R Martin R Sanders D Edwards B Schneider P
Full Access

Nearly one quarter of ankle fractures have a recognized syndesmosis injury. An intact syndesmosis ligament complex stabilizes the distal tibio-fibular joint while allowing small, physiologic amounts of relative motion. When injured, malreduction of the syndesmosis has been found to be the most important independent factor that contributes to inferior functional outcomes. Despite this, significant variability in surgical treatment remains. This may be due to a poor understanding of normal dynamic syndesmosis motion and the resultant impact of static and dynamic fixation on post-injury syndesmosis kinematics. As the syndesmosis is a dynamic structure, conventional CT static images do not provide a complete picture of syndesmosis position, giving potentially misleading results. Dynamic CT technology has the ability to image joints in real time, as they are moved through a range-of-motion (ROM). The aim of this study was to determine if syndesmosis position changes significantly throughout ankle range of motion, thus warranting further investigation with dynamic CT.

This is an a priori planned subgroup analysis of a larger multicentre randomized clinical trial, in which patients with AO-OTA 44-C injuries were randomized to either Tightrope or screw fixation. Bilateral ankle CT scans were performed at 1 year post-injury, while patients moved from maximal dorsiflexion (DF) to maximal plantar flexion (PF). In the uninjured ankles, three measurements were taken at one cm proximal to the ankle joint line in maximal DF and maximal PF: Anterior (ASD), middle (MSD), and posterior (PSD) syndesmosis distance, in order to determine normal syndesmosis position. Paired samples t-tests compared measurements taken at maximal DF and maximal PF.

Twelve patients (eight male, six female) were included, with a mean age of 44 years (±13years). The mean maximal DF achieved was 1-degree (± 7-degrees), whereas the mean maximal PF was 47-degrees (± 8-degrees). The ASD in DF was 3.0mm (± 1.1mm) versus 1.9mm (± 0.8mm) in PF (p<0.01). The MSD in DF was 3.3mm (±1.1mm) versus 2.3mm (±0.9mm) in PF (p<0.01). The PSD in DF was 5.3mm (±1.5mm) versus 4.6mm (±1.9mm) in PF (p<0.01). These values are consistent with the range of normal parameters previously reported in the literature, however this is the first study to report the ankle position at which these measurements are acquired and that there is a significant change in syndesmosis measurements based on ankle position.

Normal syndesmosis position changes in uninjured ankles significantly throughout range of motion. This motion may contribute to the variation in normal anatomy previously reported and controversies surrounding quantifying anatomic reduction after injury, as the ankle position is not routinely standardized, but rather static measurements are taken at patient-selected ankle positions. Dynamic CT is a promising modality to quantify normal ankle kinematics, in order to better understand normal syndesmosis motion. This information will help optimize assessment of reduction methods and potentially improve patient outcomes. Future directions include side-to-side comparison using dynamic CT analysis in healthy volunteers.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 66 - 66
1 Aug 2020
You D Korley R Buckley R Duffy P Harrison T Schneider P Soo A Martin R
Full Access

Venous thromboembolism (VTE) is the second most common complication and pulmonary embolism (PE) is the fourth most common cause of death after a hip fracture. Despite thromboprophylaxis, deep vein thrombosis (DVT) is detected in up to 45% of hip fracture patients. Thrombelastography (TEG) is a whole-blood, point of care test capable of providing clinicians with a global assessment of the clotting process, from fibrin formation to clot lysis. Maximal amplitude (mA) from TEG analysis is a measure of clot strength. Elevated admission mA values of >65mm and >72mm have been determined to be independent predictors of in-hospital PE. The coagulation index (CI) is calculated based on TEG parameters and defines hypercoagulable state as CI >3. This study aimed to use serial TEG analysis to determine the duration of hypercoagulable state after hip fracture.

A prospective cohort of hip fracture patients >50 years of age amenable to surgical treatment (AO 31A1–A3 & 31B1–B3) were enrolled at a Level I trauma centre. Serial TEG analysis (TEG 6S) was performed every 24-hours from admission until 5-days post-operatively and at 2- and 6-week follow-up visits. All patients received a minimum of 28 days of thromboprophylaxis. Descriptive statistics and single sample t-tests were used for comparison of mA to the 65mm threshold.

Thirty-five patients (26 female) with a median age of 83 (range = 71–86) years were included. On admission, 31.4% and 82.9% of patients were hypercoagulable based on mA >65mm and CI, respectively. At 2 weeks, all patients remained hypercoagulable, however, mA >72mm showed that 16 patients (47.1%) were at even higher risk for VTE. At 6-weeks, 65.7% and 97.1% of patients were hypercoagulable based on mA >65mm and CI, respectively. When compared with the mA >65mm threshold, patients were hypocoagulable at the time of admission (mA = 62.2 (±6.3), p = 0.011), but became significantly more hypercoagulable at 2-weeks (mA = 71.6 (±2.6), p < 0 .001), followed by continued hypercoagulability at 6-weeks, however not significantly elevated above the 65mm threshold (mA = 66.2 (±3.8), p = 0.058). One patient developed a symptomatic DVT at 2-weeks and had a mA = 72.9 and a CI of 5.9.

This is the first study to demonstrate that >50% of hip fracture patients remain hypercoagulable 6 weeks post fracture despite thromboprophylaxis, and there are individual hypercoagulable responses. This is critical, as guidelines only recommend 28 to 35 days of thromboprophylaxis in this high-risk population. Previously determined mA thresholds may be a more sensitive test for risk-stratifying patients' VTE risk than the CI threshold. Additionally, assessing ΔmA using serial TEG may better predict VTE risk.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 30 - 30
1 Aug 2020
Ristevski B Gjorgjievski M Petrisor B Williams D Denkers M Rajaratnam K Johal H Al-Asiri J Chaudhry H Nauth A Hall J Whelan DB Ward S Atrey A Khoshbin A Leighton R Duffy P Schneider P Korley R Martin R Beals L Elgie C Ginsberg L Mehdian Y McKay P Simunovic N Ratcliffe J Sprague S Vicente M Scott T Hidy J Suthar P Harrison T Dillabough K Yee S Garibaldi A Bhandari M
Full Access

Distracted driving is now the number one cause of death among teenagers in the United States of America according to the National Highway Traffic Safety Administration. However, the risks and consequences of driving while distracted spans all ages, gender, and ethnicity. The Distractions on the Road: Injury eValuation in Surgery And FracturE Clinics (DRIVSAFE) Study aimed to examine the prevalence of distracted driving among patients attending hospital-based orthopaedic surgery fracture clinics. We further aimed to explore factors associated with distracted driving.

In a large, multi-center prospective observational study, we recruited 1378 adult patients with injuries treated across four clinics (Hamilton, Ontario, Toronto, Ontario, Calgary, Alberta, Halifax, Nova Scotia) across Canada. Eligible patients included those who held a valid driver's license and were able to communicate and understand written english. Patients were administered questions about distracted driving. Data were analyzed with descriptive statistics.

Patients average age was 45.8 years old (range 16 – 87), 54.3% male, and 44.6% female (1.1% not disclosed). Of 1361 patients, 1358 self-reported distracted driving (99.8%). Common sources of distractions included talking to passengers (98.7%), outer-vehicle distractions (95.5%), eating/drinking (90.4%), music listening/adjusting the radio (97.6%/93.8%), singing (83.2%), accepting phone calls (65.6%) and daydreaming (61.2%). Seventy-nine patients (6.3%), reported having been stopped by police for using a handheld device in the past. Among 113 drivers who disclosed the cause of their injury as a motor vehicle crash (MVC), 20 of them (17%) acknowledged being distracted at the time of the crash. Of the participants surveyed, 729 reported that during their lifetime they had been the driver in a MVC, with 226 (31.1%) acknowledging they were distracted at the time of the crash.

Approximately, 1 in 6 participants in this study had a MVC where they reported to be distracted. Despite the overwhelming knowledge that distracted driving is dangerous and the recognition by participants that it can be dangerous, a staggering amount of drivers engage in distracted driving on a fairly routine basis. This study demonstrates an ongoing need for research and driver education to reduce distracted driving and its devastating consequences.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 71 - 71
1 Aug 2020
Meldrum A Schneider P Harrison T Kwong C Archibold K
Full Access

Olecranon Osteotomy is a common approach used in the management of intraarticular distal humerus fractures. Significant complication rates have been associated with this procedure, including non-union rates of 0–13% and implant removal rates between 12–86%. This study is a multicentre retrospective study involving the largest cohort of olecranon osteotomies in the literature, examining implant fixation types, removal rates and associated complications.

Patients were identified between 2007 and 2017 (minimum one year follow-up) via Canadian Classification of Health Interventions (CCI) coding and ICD9/10 codes by our health region's data information service. CCI intervention codes were used to identify patients who underwent surgery for their fracture with an olecranon osteotomy. Reasons for implant removal were identified from a chart review. Our primary outcome was implant removal rates. Categorical data was assessed using Chi square test and Fischer's Exact test.

Ninety-nine patients were identified to have undergone an olecranon osteotomy for treatment of a distal humerus fracture. Twenty patients had their osteotomy fixed with a plate and screws and 67 patients were fixed with a tension band wire. Eleven patients underwent “screw fixation”, consisting of a single screw with or without the addition of a wire. One patient had placement of a cable-pin system. Of patients who underwent olecranon osteotomy fixation, 34.3% required implant removal. Removal rates were: 28/67 for TBW (41.8%), 6/20 plates (30%), 0/1 cable-pin and 0/11 for osteotomies fixed with screw fixation. Screw fixation was removed less frequently than TBW p<.006. TBW were more commonly removed than all other fixation types p<.043. Screws were less commonly removed than all other fixation types p<.015. TBW were more likely to be removed for implant irritation than plates, p<.007, and all other implants p<.007. The average time to removal was 361 days (80–1503 days). A second surgeon was the surgeon responsible for the removal in 10/34 cases (29%). TBWs requiring removal were further off the olecranon tip than those not removed p=.006. TBWs were associated with an OR of 3.29 (CI 1.10–9.84) for implant removal if implanted further than 1mm off bone. Nonunion of the osteotomy occurred in three out of 99 patients (3%). K-wires through the anterior ulnar cortex did not result in decreased need for TBW removal. There was no relation between plate prominence and the need for implant removal. There was no association between age and implant removal.

The implant removal rate was 34% overall. Single screw fixation was the best option for osteotomy fixation, as 0/11 required hardware removal, which was statistically less frequent than TBW at 28/67. Screw fixation was removed less frequently than TBW and screw fixation was less commonly removed than all other fixation types. Only 6/20 (30%) plates required removal, which is lower than previously published rates. Overall, TBW were more commonly removed than all other fixation types and this was also the case if hardware irritation was used as the indication for removal. Nonunion rates of olecranon osteotomy were 3%.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 87 - 87
1 Aug 2020
Gusnowski E Schneider P
Full Access

Distal radius fractures (DRF) are the most common fracture type in all age groups combined. Unstable DRF may be surgically managed with volar or dorsal plate fixation. Dorsal plating has traditionally been associated with decreased range of motion (ROM). However, this assumption has not been recently assessed to determine whether functional ROM is achievable (approximately 54 degrees of flexion and 60 degrees of extension) with recent advances in lower profile dorsal plate design. The aim of this study was therefore to compare ROM and patient reported outcome measures between volar and dorsal plating methods for DRF.

A meta-analysis was performed to directly compare ROM and Disabilities of Arm, Shoulder and Hand (DASH) scores between dorsal and volar plate fixation for DRF. Separate literature searches for each plating method were performed using MedLine and EMBase on January 28, 2018. Exclusion criteria consisted of non-English articles, basic science articles, animal/cadaver studies, case studies/series, combined operative approaches, papers published more than 20 years ago and paediatric studies. Only articles with at least one year patient follow-up and a) ROM and AO-OTA distal radius fracture classification, or b) DASH scores were included. Raw data was extracted from all articles that met inclusion criteria to compile a comprehensive dataset for analysis. Descriptive statistics with z-score comparison for AO-OTA classification or a two-tailed independent samples t-tests for ROM and DASH scores for dorsal versus volar plating were performed. Significance was defined as p < 0 .05.

After rigorous screening, six dorsal plating and 43 volar plating articles met inclusion criteria for ROM/AO-OTA classification versus six dorsal plating and 44 volar plating articles for DASH scores. The weighted means of flexion (dorsal 54.9 degrees, SD 9.3, n=257, volar 61.3 degrees, SD 11.5, n=1906) and extension (dorsal 60 degrees, SD 12, n=257, volar 62.8 degrees, SD 11.4, n=1906) were significantly different (both p < 0 .001) between the two plating methods. The volar plating group had a significantly higher proportion of type C fractures (dorsal 0.5, n =169, volar 0.6, n=1246, p < 0 .001). The weighted means of reported DASH scores were not significantly different between dorsal (14, SD 14.8) versus volar (13.6, SD 12.8) plating (p=0.54).

Though mean wrist flexion and extension were statistically different between the dorsal versus volar plating methods, the difference between group means was less than 5-degrees, which is unlikely to be clinically significant. Additionally, there was no significant difference in DASH scores between the two plating methods. Taken together, these findings imply that the statistical difference in ROM outcomes are likely not clinically significant and should therefore not dictate choice of plating method for fixation of DRF.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 80 - 80
1 Aug 2020
Montgomery S Schneider P Kooner S
Full Access

Three dimensional printing is an emerging new technology in medicine and the current educational value of 3D printed fracture models is unknown. The delayed surgery and need for CT imaging make calcaneal fractures an ideal scenario for preoperative 3D printed (3Dp) fracture models. The goal of this study is to assess if improvements in fracture understanding and surgical planning can be realized by trainees when they are given standard CT imaging and a 3Dp model compared to standard CT imaging and a virtual 3D rendering (3D CT).

Ethics approval was granted for a selection of calcaneal fracture imaging studies to be collected through a practice audit of a senior orthopaedic trauma surgeon. 3Dp models were created in house. Digital Imaging and Communications in Medicine (DICOM) files of patient CT scans were obtained from local servers in an anonymized fashion. DICOM files were then converted to .STL models using the Mimics inPrint 2.0 (Materialise NV, Leuven, Belgium) software. Models were converted into a .gcode file through a slicer program (Simplify3D, Blue Ash, OH USA). The .gcode files were printed on a TEVO Little Monster Delta FDM printer (TEVO USA, CO USA) using 1.75mm polylactic acid (PLA) filament.

Study participants rotated through 10 workstations viewing CT images and either a digital 3D volume rendering or 3Dp model of the fractured calcaneus. A questionnaire at each workstation assessed fracture classification, proposed method of treatment, confidence with fracture understanding and satisfaction with the accuracy of the 3Dp model or 3D volume rendering. Participants included current orthopaedic surgery trainees and staff surgeons.

A total of 16 residents and five staff completed the study. Ten fracture cases were included in the analysis for time, confidence of fracture understanding, perceived model accuracy and treatment method. Eight fracture cases were included for assessment of diagnosis. There were no cases that obtained universal agreement on either Sanders classification or treatment method from staff participants. Residents in their final year of studies had the quickest mean time of assessment (60 +/− 24 sec.) and highest percentage of correct diagnoses (83%) although these did not reach significance compared to the other residency years. There was a significant increase in confidence of fracture understanding with increasing residency year. Also, confidence was improved in cases where a 3Dp model was available compared to conventional CT alone although this improvement diminished with increasing residency year. Perceived accuracy of the cases with 3Dp models was significantly higher than cases without models (7 vs 5.5 p < 0.0001).

This is the first study to our knowledge to assess trainee confidence as a primary outcome in the assessment of the educational value of 3Dp models. This study was able to show that a 3Dp model aides in the perceived accuracy of fracture assessment and showed an improvement in trainee confidence, although the effect on confidence seems to diminish with increasing residency year. We propose that 3D printed calcaneal fracture models are a beneficial educational tool for junior level trainees and the role of 3Dp models for other complex orthopaedic presentations should be explored.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 89 - 89
1 Aug 2020
Bourget-Murray J Kendal J Schneider P Montgomery S Kooner S Kubik J Meldrum A Kwong C Gusnowski E Thomas K Fruson L Litowski M Sridharan S You D Purnell J James M Wong M Ludwig T Abbott A Lukenchuk J Benavides B Morrison L
Full Access

Advances in orthopaedic surgery have led to minimally invasive techniques to decrease patient morbidity by minimizing surgical exposure, but also limits direct visualization. This has led to the increased use of intraoperative fluoroscopy for fracture management. Unfortunately, these procedures require the operating surgeon to stay in close proximity to the patient, thus being exposed to radiation scatter. The current National Council on Radiation Protection recommends no more than 50 mSv of radiation exposure to avoid ill-effects. Risks associated with radiation exposure include cataracts, skin, breast and thyroid cancer, and leukemia. Despite radiation protection measures, there is overwhelming evidence of radiation-related diseases in orthopaedic surgeons. The risk of developing cancer (e.g. thyroid carcinoma and breast cancer) is approximately eight times higher than in unexposed workers. Despite this knowledge, there is a paucity of evidence on radiation exposure in orthopaedic surgery residents, therefore the goal of this study is to quantify radiation exposure in orthopaedic surgery residents.

We hypothesize that orthopaedic surgery residents are exposed to a significant amount of radiation throughout their training. We specifically aim to: 1) quantify the amount of radiation exposure throughout a Canadian orthopaedic residency training program and 2) determine the variability in resident radiation exposure by rotation assignment and year of training.

This ongoing prospective cohort study includes all local orthopaedic surgery residents who meet eligibility criteria. Inclusion criteria: 1) adult residents in an orthopaedic surgery residency program. Exclusion criteria: 1) female residents who are pregnant, and 2) residents in a non-surgical year (i.e. leave of absence, research, Masters/PhD). After completion of informed consent, each eligible resident will wear a dosimeter to measure radiation exposure in a standardized fashion. Dosimeters will be worn on standardized lanyards underneath lead protection in their left chest pocket during all surgeries that require radiation protection. Control dosimeters will be worn on the outside of each resident's scrub cap for comparison. Dosimeter readings will then be reported on a monthly and rotational basis. All data will be collected on a pre-developed case report form. All data will be de-identified and stored on a secure electronic database (REDCap). In addition to monthly and rotational dosimeter readings, residents will also report sex, height, level of training, parental status, and age for secondary subgroup analyses. Residents will also report if they have personalized lead or other protective equipment, including lead glasses. Resident compliance with dosimeter use will be measured by self report of >80% use on operative days. Interim analysis will be performed at the 6-month time point and data collection will conclude at the 1 year time point.

Data collection began in July 2018 and interim 6-month results will be available for presentation at the CORA annual meeting in June 2019.

This is the first prospective study quantifying radiation exposure in Canadian orthopaedic residents and the results will provide valuable information for all Canadian orthopaedic training programs.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 105 - 105
1 Jul 2020
Gusnowski E Schneider P Thomas K
Full Access

Distal radius fractures (DRF) are the most common fracture type in all age groups combined. Unstable DRF may be surgically managed with volar or dorsal plate fixation. Dorsal plating has traditionally been associated with decreased range of motion (ROM). However, this assumption has not been recently assessed to determine whether functional ROM is achievable (approximately 54o of flexion and 60o of extension) with recent advances in lower profile dorsal plate design. The aim of this study was therefore to compare ROM and patient reported outcome measures between volar and dorsal plating methods for DRF.

A meta-analysis was performed to directly compare ROM and DASH scores between dorsal and volar plate fixation for DRF. Separate literature searches for each plating method were performed using MedLine and EMBase on January 28, 2018. Exclusion criteria consisted of non-English articles, basic science articles, animal/cadaver studies, case studies/series, combined operative approaches, papers published more than 20 years ago and paediatric studies. Only articles with at least one year patient follow-up and a) ROM and AO distal radius fracture classification, or b) DASH scores were included. Raw data was extracted from all articles that met inclusion criteria to compile a comprehensive dataset for analysis. Descriptive statistics with z-score comparison for AO classification or a two-tailed independent samples t-test for ROM and DASH scores for dorsal versus volar plating were performed. Significance was defined as p < 0 .05.

After rigorous screening, 6 dorsal plating and 43 volar plating articles met inclusion criteria for ROM/AO classification versus 6 dorsal plating and 44 volar plating articles for DASH scores. The weighted means of flexion (dorsal 54.9o, SD 9.3, n=257, volar 61.3o, SD 11.5, n=1906) and extension (dorsal 60.0o, SD 12, n=257, volar 62.8o, SD 11.4, n=1906) were statistically significantly different (both p < 0 .001) between the two plating methods. The volar plating group had a significantly higher proportion of AO type C fractures (dorsal 0.5, n =169, volar 0.6, n=1246, p < 0 .001). The weighted means of reported DASH scores were not significantly different between dorsal (14.01, SD 14.8) versus volar (13.6, SD 12.8) plating (p=0.54).

Though mean wrist flexion and extension were statistically different between the dorsal versus volar plating methods, the difference between group means was less than 5o, which is unlikely to be clinically significant. Additionally, we did not find a significant difference in DASH scores between the two plating methods. Taken together, these findings imply that the statistical difference in ROM outcomes are likely not clinically significant and should therefore not dictate choice of plating method for fixation of DRF.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 22 - 22
1 Jul 2020
Wong M Buckley R Duffy P Korley R Martin R Harrison T Sanders DW Schneider P Wiens C
Full Access

The syndesmosis ligament complex stabilizes the distal tibiofibular joint, while allowing for the subtle fibular motion that is essential for ankle congruity. Flexible fixation with anatomic syndesmosis reduction results in substantial improvements in functional outcomes. New dynamic CT technology allows real-time imaging, as the ankle moves through a range of motion. The aim of this study was to determine if dynamic CT analysis is a feasible method for evaluating syndesmosis reduction and motion following static and flexible syndesmosis fixation.

This is a subgroup analysis of a larger multicenter randomized clinical trial, in which patients with AO 44-C injuries were randomized to either Tightrope (one knotless Tightrope, Group T) or screw fixation (two 3.5-mm cortical screws, Group S). Surgical techniques and rehabilitation were standardized. Bilateral ankle CT scans were performed at one year post-injury, while patients moved from maximal dorsiflexion (DF) to maximal plantar flexion (PF). Three measurements were taken at one cm proximal to the ankle joint line in maximal DF and maximal PF: anterior, midpoint, and posterior tibiofibular distances. T-tests compared Group T and Group S, and injured and uninjured ankles in each group.

Fifteen patients (six Group T [three male], nine Group S [eight male]) were included. There was no difference for mean age (T = 42.8 ± 14.1 years, S = 37 ± 12.6, P = 0.4) or time between injury and CT scan (T = 13 ± 1.8 months, S = 13.2 ± 1.8, P = 0.8). Of note in Group S, seven of nine patients had at least one broken screw and one additional patient had screws removed by the time of their dynamic CT. There was no significant difference between treatment groups for tibiofibular distance measurements in maximal PF or DF. Group T showed no significant difference between the injured and uninjured side for tibiofibular measurements in maximal PF and DF, suggesting anatomic reduction. For Group S, however, there was a significantly larger distance for all three measurements at maximal PF compared to the uninjured ankle (all P < 0 .05).

In all but one Group S patient, screws were broken or removed prior to their dynamic CT, allowing possible increased syndesmotic motion, similar to Group T. Despite this, dynamic CT analysis detected increased tibiofibular distance in Group S as ankles moved into maximal PF when compared with the uninjured ankle. Given the importance of anatomic syndesmosis reduction, dynamic ankle CT technology may provide valuable physiologic information warranting further investigation.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 32 - 32
1 Nov 2016
Rollick N Korley R Buckley R Duffy P Martin R Schneider P
Full Access

Orthopaedic surgeons frequently assess fragility fractures (FF), however osteoporosis (OP) is often managed by primary care physicians (PCP). Up to 48% of FF patients have had a previous fracture (Kanis et al., 2004). Discontinuity between fracture care and OP management is a missed opportunity to reduce repeat fractures. This studied aimed to evaluate current OP management in FF patients presenting to cast clinic.

A single centre, prospective observational study where seven traumatologists screened for FF in cast clinic. FF was defined as a hip, distal radius (DR), proximal humerus (PH), or ankle fracture due to a ground level fall. Patients completed a self-administered questionnaire for demographics, fracture type and treatment, medical and fracture history, and previous OP care. The primary outcome was number of FF patients who received OP investigation and/or treatment. Secondary outcomes included Fracture Risk Assessment Tool (FRAX), repeat fracture rate, and anti-resorptive related fractures. Descriptive statistics were used for analysis.

Between November 17, 2014 and October 13, 2015, a total of 1,677 patients attended cast clinic for an initial assessment. FF were identified in 120 patients (7.2%). The FF cohort had a mean age of 65.3 (± 14.3) years, mean BMI of 26.1 (± 5.3), and was comprised of 83.3% females. Fracture distribution was 69 (57.5%) DR, 23 (19%) ankle, 20 (16.5%) PH, and seven (5.8%) hip fractures, with 24 of the FF (19.8%) treated operatively. Thirteen (10.8%) were current smokers and 40 (33.3%) formerly smoked. A history of steroid use was present in 13 patients (10.8%). Ninety (n = 117; 76.9%) of patients ambulated independently. Twenty-two patients (18.3%) reported prior diagnosis of OP, most often by a PCP (n = 19; 73.7%) over 5 years previously. Calcium (n = 59; 49.2%) and Vitamin D (n = 70; 58.3%) were common and 26 patients (21.5%) had a prior anti-resorptive therapy, with Alendronate (n = 9) being most common. One patient had an anti-resorptive-related fracture. Raloxifene was used in ten patients. Forty-seven patients (39.2%) had a prior fracture at a mean age of 61.3 (± 11.9) years, with DR and PH fractures being most common. Eleven patients had two or more prior fractures. A family history of OP was found in 34 patients (28.1%). Mean FRAX score was 20.8% (± 10.8%) 10-year major fracture risk and 5.9% (± 6.6%) 10-year hip fracture risk (n = 30 bone densiometry within one-year). Of the 26 patients with a Moderate (10–20%) or High (> 20%) 10-year major fracture risk, only eight (30.8%) reported a diagnosis of OP and only three (11.5%) had seen an OP specialist.

Cast clinics provide an opportunity for OP screening, initiation of treatment, and patient education. This cohort demonstrated a high rate of repeat fractures and poor patient reporting of prior OP diagnosis. This study likely underestimated FF and calls for resource allocation for quantifying true burden of disease and outpatient fracture liaison service.