header advert
Results 21 - 25 of 25
Results per page:
Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 16 - 16
1 Jan 2004
Price A Short A Kellett C Rees J Pandit H Dodd C McLardy-Smith P Gundle R Murray D
Full Access

The aim of the study was to measure in-vivo the 10-year linear and volumetric polyethylene wear of a fully congruent mobile bearing unicompartmental knee arthroplasty (OUKA).

We studied six OUKA’s that had all been implanted 10 years previously. Each patient was examined in even double leg stance at a range of knee flexion angles, in a calibration cage. A stereo pair of X-ray films was acquired for each patient at 0°, 15° and 30° of flexion. The films were analysed using an RSA style calibration and a CAD model silhouette-fitting technique. The position and orientation of each femoral and tibial component was found relative to each other and the bearing position inferred. Penetration of the femoral component into the original volume of the bearing was our estimate of linear wear. The volumetric wear is calculated from the measured linear wear and the known surface area of the bearing. In addition eight control patients were examined less than 3 weeks post-operation where no wear would be expected.and 30We studied seven OUKA’s that had all been implanted at least 10 years previously. A stereo pair of X-ray films was acquired for each patient at 0 Results: The control group showed no measured wear. The seven OUKA’s had an average maximum depth of linear penetration of 0.40 mm at a mean follow-up of 10.9 years. The linear wear rate was 0.033 mm/year. The volumetric material loss was 79.8 mm3. If a steady gradual material loss is assumed, 8 mm3 of UHMWPE was lost per year.

Polyethylene particulate wear debris continues to be implicated in the aetiology of component loosening and implant failure knee following arthroplasty. The OUKA employs a spherical femoral component and a fully congruous meniscal bearing to increase contact area and theoretically reduce the potential for polyethylene wear. The results from this in-vivo study confirm that the device has low 10-year linear and volumetric wear in clinical practice. This may protect the device from component loosening in the long term.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 12 - 12
1 Jan 2004
Pandit H Price A Rees J Beard D Gill H Dodd C Murray D
Full Access

The indications for unicompartmental knee arthroplasty (UKA) can be contentious. Concerns exist about implanting a UKA in younger individuals. It has been reported that it is contra-indicated in patients under the age of 60. The suggestion is that younger patients may compromise their outcome after surgery by their increased activity levels. However, the number of publications with data on UKA in young patients is minimal and the age/activity related criteria for UKA remains unknown.

The aim of the study was 1) to confirm that younger UKA patients have higher activity levels than older patients, and 2) to test the hypothesis that younger, more active patients have inferior outcome when compared to older less active patients.

Fifty consecutive patients undergoing UKA who were under 60 years (Group Y) and 50 patients over 60 years (Group O) were recruited. Indications were anteromedial arthritis with full thickness lateral compartment cartilage, a functioning ACL and a correctible varus. All patients underwent Oxford UKA using the minimally invasive technique. This device employs an unconstrained fully congruous meniscal bearing. Outcome was evaluated using Knee Society Scores. Activity level was documented using Tegner Activity Score.

Average age of patients for group Y and O was 55 and 68 years respectively. Minimum follw-up was 2 years. pre-op. knee scores were comparable for each group. (y: 38.8, O: 35.8) and patients in both groups siginificantly improved after surgery. A significant difference in Tegner score was found between the two groups after surgery (y:4.1, O:2.6). More than 50% of younger patients regularly participated in high demand activities like skiing, tennis and manual labour. No statistically significant differences in any other post op. knee scores or complication rate were found despite adequate study power.

Younger patients have increased activity levels after UKA when compared to an older age group. There is no evidence that the outcome of UKA in younger more active patients will be inferior to those who are older and more sedentary.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 363 - 363
1 Nov 2002
Pandit H Price A Rees J Beard D Gill H Murray D Dodd C
Full Access

Introduction: The indications for unicompartmental knee arthroplasty (UKA) can be contentious. Concerns exist about implanting a UKA in younger individuals and it has been reported that the procedure is contra-indicated in patients under the age of 60. The suggestion is that younger patients may compromise their outcome after surgery by their increased activity levels. However, the number of publications with data on UKA in young patients is minimal and the age/activity related criteria for UKA remains unknown.

Aim: The aim is twofold: 1) to confirm that younger UKA patients have higher activity levels than older patients, and 2) to test the hypothesis that younger, more active patients have inferior outcome when compared to older less active patients.

Materials and methods: Fifty consecutive patients undergoing UKA who were under 60 years old at the time of surgery (Group Y) and 50 patients over 60 years (Group O) were recruited. Indications were anteromedial arthritis with full thickness lateral compartment cartilage, a functioning ACL and a correctible varus deformity. All patients underwent Oxford UKA using the minimally invasive technique. This device employs an unconstrained fully congruous meniscal bearing. Outcome was evaluated using the American Knee Society Score (AKSS). Activity level was documented using the established Tegner Activity Score.

Results: The average age of patients for group Y and O was 55 years and 68 years respectively. Minimum follow up for both groups was 2 years. Pre-operative AKSS scores were comparable for each group (Group Y = 38.8, Group O = 35.8) and patients in both groups significantly improved after surgery. A significant difference in Tegner score was found between groups after surgery (Group Y = 3.9, Group O = 2.6). It was found that 40% of younger patients regularly participate in high demand activities like skiing, tennis, hard manual labour and swimming. No statistically significant difference in any other post operative knee scores or complication rate were found despite adequate study power.

Conclusions: Younger patients have increased activity levels after UKA when compared to an older age group. There is no evidence that the outcome of UKA in younger more active patients will be inferior to those who are older and more sedentary.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 156 - 156
1 Jul 2002
Price AJ Beard D Rees J Carter S White S de Steiger R Gibbons M McLardy-Smith P Gundle R Dodd D Murray D O’Connor J Goodfellow J
Full Access

Purpose: As part of the step-wise introduction of a meniscal-bearing total knee replacement (Oxford TMK) we needed to know, before proceeding to longer term studies, whether its early clinical results were at least as good as those of an established fixed bearing device (AGC).

Material and Methods: With ethical approval, patients requiring bilateral knee replacement for osteoarthritis consented to have the operations under one anaesthetic using one of each prosthesis; to accept random choice of knee; and to remain ignorant which side was which. American Knee Society Scores, Oxford Knee Scores, ROM and pain scores were to be recorded preoperatively and at one year. By January 2001, 40 patients had reached one year and data is available for 36.

Results: Preoperatively there was no difference between the two knees. One patient died in the peri-operative period.

Results at one year (TMK first): AKSS(Knee) 91.6 / 84.1 (p=0.003), OKS 39.8 / 37.6 (p=0.006), ROM 104 / 104 (p=0.364), Pain (AKSS) 47.3 / 41.7 (p=0.01), Pain (OKS) 3.5 / 2.9 (p=0.006).

Conclusion: The TMK performed as well as the AGC. Its AKSS, OKS and pain scores were significantly better. We believe this controlled, blinded trial is the first to have compared the function of a new knee prosthesis with a standard implant before marketing; and the first to have demonstrated a significant clinical advantage for a meniscal-bearing over a fixed bearing TKR. The comparison of bilateral implants in the same patient can reveal significant differences while putting at risk many fewer subjects than would be needed for a classical twocohort RCT.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 629 - 634
1 Aug 1986
Volpin G Rees J Ali S Bentley G

Experimentally produced fractures in long bones studied by light and electron microscopic histochemistry were found to heal by a process of enchondral calcification. There was intense proliferation in the cells of the cambium layer of the periosteum, with differentiation to chondroblasts and osteoblasts, suggesting that this layer was the primary tissue responsible for development of the callus. Cytoplasmic processes of the hypertrophic chondrocytes appeared to bud and produce matrix vesicles. Alkaline phosphatase activity was detected along the plasma membrane of the hypertrophic chondrocytes and around the matrix vesicles, before any signs of mineral deposition. Calcification took place by deposition of hydroxyapatite crystals in and around these matrix vesicles which frequently showed alkaline phosphatase activity. It is suggested that there is a close functional association between alkaline phosphatase activity and calcification in the process of fracture healing, which is another type of enchondral calcification mediated by matrix vesicles.