header advert
Results 21 - 24 of 24
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 122 - 122
1 Sep 2012
Ahmad S Jameson S James P Reed M McVie J Rangan A
Full Access

Background

A recent Cochrane review has shown that total shoulder arthroplasty (TSA) seems to offer an advantage in terms of shoulder function over hemiarthroplasty, with no other obvious clinical benefits. This is the first study to compare complication rates on a national scale.

Methods

All patients (9804 patients) who underwent either TSA or shoulder hemiarthroplasty as a planned procedure between 2005 and 2008 in the English NHS were identified using the hospital episodes statistic database. Data was extracted on 30-day rates of readmission, wound complications, reoperation and medical complications (myocardial infarction (MI) and chest infection (LRTI)), and inpatient 90-day DVT, PE and mortality rates (MR). Revision rate at 18 months was analysed for the whole cohort and, for a subset of 939 patients, 5-year revision rate. Odds ratio (OR) was used to compare groups.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 75 - 75
1 Jun 2012
Gill I Krishnan M Reed M Partington P
Full Access

Introduction

To report the short to medium term results of acetabular reconstruction using reinforcement/reconstruction ring, morcellised femoral head allograft and cemented metal on metal cup.

Methods

Single centre retrospective study of 6 consecutive patients who underwent acetabular reconstruction for revision hip surgery.

The acetabulum was reconstructed using morcellised femoral head allograft and reinforcement or reconstruction ring fixed with screws. The Birmingham cup – designed for cementless fixation, was cemented into the ring in all cases. The uncemented Echelon stem with metal on metal modular head was used for reconstructing the femur.

Data from our previous in-vitro study had shown good pull out strength of a cemented Birmingham cup.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 74 - 74
1 Jun 2012
Gill I Krishnan M Reed M Partington P
Full Access

Introduction

The aim of this study is to report the results of Revision hip arthroplasty using large diameter, metal on metal bearing implants- minimum 2 year follow up.

Methods

A single centre retrospective study was performed of 22 consecutive patients who underwent acetabular revision surgery using metal on metal bearing implants between 2004 and 2007. Birmingham hip resurfacing (BHR) cup was used in all patients - monoblock, uncemented, without additional screws in 16 cases and cemented within reinforcement or reconstruction ring in 6 cases.

Femoral revisions were carried out as necessary.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 81 - 81
1 Feb 2012
Lakshmanan P Ahmed S Dixit V Reed M Sher J
Full Access

Background

Percutaneous K-wire fixation is a well-recognised and often performed method of stabilisation for distal radius fractures. However, there is paucity in the literature regarding the infection rate after percutaneous K-wire fixation for distal radius fractures.

Aims

To analyse the rate and severity of infection after percutaneous K-wire fixation for distal radius fractures.