header advert
Results 1 - 20 of 93
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 24 - 30
1 Mar 2024
Fontalis A Wignadasan W Mancino F The CS Magan A Plastow R Haddad FS

Aims

Postoperative length of stay (LOS) and discharge dispositions following arthroplasty can be used as surrogate measurements for improvements in patients’ pathways and costs. With the increasing use of robotic technology in arthroplasty, it is important to assess its impact on LOS. The aim of this study was to identify factors associated with decreased LOS following robotic arm-assisted total hip arthroplasty (RO THA) compared with the conventional technique (CO THA).

Methods

This large-scale, single-institution study included 1,607 patients of any age who underwent 1,732 primary THAs for any indication between May 2019 and January 2023. The data which were collected included the demographics of the patients, LOS, type of anaesthetic, the need for treatment in a post-anaesthesia care unit (PACU), readmission within 30 days, and discharge disposition. Univariate and multivariate logistic regression models were used to identify factors and the characteristics of patients which were associated with delayed discharge.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 324 - 335
1 Apr 2024
Fontalis A Kayani B Plastow R Giebaly DE Tahmassebi J Haddad IC Chambers A Mancino F Konan S Haddad FS

Aims

Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA.

Methods

This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 106 - 106
1 Jan 2016
Daivajna S Agnello L Bajwa A Villar R
Full Access

Introduction. Short-stem hip arthroplasty is gaining popularity as a method of treating hip arthritis in biologically younger patients. The potential benefit of using a short-stem is preservation of bone in the proximal femur for a future revision. We have compared the early clinical and radiological results of a short-stem hip arthroplasty versus a conventional total hip arthroplasty (THA) using a standard length femoral prosthesis with particular focus on functional outcome. Methods. We evaluated a prospectively collected data on consecutive series of 249 patients, who underwent uncemented total hip arthroplasty at our institution. They were distributed into 2 groups: Group I, 125 patients received an uncemented short femoral stem (Mini Hip Arthroplasty (MHA), Corin, Cirencester) and Group II, 124 patients received a conventional uncemented femoral stem (Accolade, Stryker, Michigan) with mean follow up of 3.2 years (2–4). The characteristics of the two groups have been presented in Table I. Evaluation was based on plain radiographs performed at 6 months, 1 year and 2 years postoperatively, while their clinical status was assessed using the modified Harris hip score (mHHS) preoperatively and postoperatively at 6 weeks, 6 months, 1-year, 2-years and annually thereafter. Results. The outcome measures and complications in the two groups are presented in Table II. The mHHS was split into their two components (pain and function) to evaluate any differences between the groups. The postoperative results for pain were similar in both groups (p > 0.05), but the functional element of mHHS was significantly better (p < 0.05)* in Group I compared to Group II. This difference however did not reach the level of the minimum clinically important difference. All femoral stems showed radiographic evidence of bony ingrowth. No evidence of stem subsidence was found in any of the patients. One femoral implant was revised for infection in Group II. Conclusion. Our study suggests that the results of short-stem hip arthroplasty are comparable to conventional uncemented THA in the short-term. The functional outcome scores appear to be better in the short-stem group compared to the conventional group, but the difference is not clinically relevant. Short-stem hip arthroplasty can be an optimal choice for use in younger patients with good bone quality, who are expected to require revision in the future


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 31 - 31
1 Dec 2022
Sheridan G Clesham K Greidanus NV Masri B Garbuz D Duncan CP Howard L
Full Access

To date, the literature has not yet revealed superiority of Minimally Invasive (MI) approaches over conventional techniques. We performed a systematic review to determine whether minimally invasive approaches are superior to conventional approaches in total hip arthroplasty for (1) clinical and (2) functional outcomes. We performed a meta-analysis of level 1 evidence to determine whether (3) minimally invasive approaches are superior to conventional approaches for clinical outcomes.

All studies comparing MI approaches to conventional approaches were eligible for analysis. The PRISMA guidelines were adhered to throughout this study. Registries were searched using the following MeSH terms: ‘minimally invasive’, ‘muscle-sparing’, ‘THA’, ‘THR’, ‘hip arthroplasty’ and ‘hip replacement’. Locations searched included PubMed, the Cochrane Library, ClinicalTrials.gov, the EU clinical trials register and the International Clinical Trials Registry Platform (World Health Organisation).

Twenty studies were identified. There were 1,282 MI THAs and 1,351 conventional THAs performed.

There was no difference between MI and conventional approaches for all clinical outcomes of relevance including all-cause revision (p=0.959), aseptic revision (p=0.894), instability (p=0.894), infection (p=0.669) and periprosthetic fracture (p=0.940).

There was also no difference in functional outcome at early or intermediate follow-up between the two groups (p=0.38).

In level I studies exclusively, random-effects meta-analysis demonstrated no difference in the rate of aseptic revision (p=0.461) between both groups.

Intermuscular MI approaches are equivalent to conventional THA approaches when considering all-cause revision, aseptic revision, infection, dislocation, fracture rates and functional outcomes. Meta-analysis of level 1 evidence supports this claim.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 4 - 4
1 Mar 2010
Vendittoli P Lavigne M Roy AG Lusignan D
Full Access

Purpose: Surface replacement arthroplasty is being increasingly offered as the treatment of choice to young and active patients with hip arthritis with proposed advantages including bone conservation and better functional outcome. Excellent outcome has been reported in the few recent short-term clinical series of surface replacement arthroplasty. However they have an inbuilt patient selection bias. There are no direct prospective randomized studies comparing the newer generation of surface replacement arthroplasty with conventional total hip arthroplasty. Our study addresses this issue. Method: 210 hips in 194 patients were randomized to receive either an uncemented total hip arthroplasty or a hybrid metal-on-metal surface replacement arthroplasty. Complications, functional outcomes, along with patient satisfaction and radiographic evaluation were compared at a minimum of two years follow up. Results: Patients in both groups demonstrated a very high satisfaction rate and achieved similar functional scores. Four dislocations occurred in the THA group (one needing acetabular cup revision) and none in the SRA group. There were no femoral neck fractures in the surface replacement arthroplasty group. However, two surface replacement arthroplasty cases underwent revision for late head collapse and one needed a femoral neck osteoplasty for persisting femoro-acetabular impingement. Better biomechanical restoration was attained with surface replacement arthroplasty. All the components were considered to be stable after an average follow up of 45 months. Conclusion: Although surface replacement arthroplasty of the hip offer similar patient satisfaction, functional outcome and complication rate as an uncemented total hip arthroplasty in a young and active group of patients, different complications were associated to each procedure. Better patient selection could avoid some of the complications in the surface replacement arthroplasty group. One main advantage that remains for the surface arthroplasty technique it is the proximal femoral bone stock preservation. However, long term survival analysis is necessary to determine the true advantage of these implants over total hip arthroplasty


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 119 - 119
1 Jun 2012
Kreuzer S Leffers K
Full Access

Introduction

The incorporation of computer navigation in total hip arthroplasty (THA) has been much slower then for total knee arthroplasty (TKA). Computer navigation has proven itself in the realm of TKA but still has yet to advance in THA. The reasons for this include the lack of ease of incorporation, accuracy and precision, and the addition of overall operative time. Another reason for this lack of progress is that a majority of THA's are done with the patient in the lateral position through a posterior or lateral approach making the tracker placement and the registration process somewhat cumbersome. In the direct anterior approach the patient is in the supine position, which accommodates pelvic tracker placement and significantly facilitates the registration process. At our institution we use the direct anterior approach and computer navigation on all of our primary THA's. We hypothesized that computer navigation facilitates cup placement and leg length determination with out significantly increasing our operative time.

Materials and Methods

This was a prospective study comparing a consecutive series of 150 computer navigated total hips to a consecutive series of 150 none navigated total hips. The two groups were similar by age, sex, and BMI. Operative times were collected using our secure online database. The start and stop of operative time was incision to final reduction respectively. Post operative radiographs were analyzed using TraumaCad 2.0 (Voyant Health, Columbia, MD). Cup angle and leg length were measured on A/P pelvic views. Simple descriptive statistics and t-tests were used to analyze data.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 46 - 46
10 Feb 2023
Tuffley C Tuffley J Donnelly W Harris I Cuthbert A
Full Access

In this study we compare survivorship and patient reported outcome measures in robotically assisted versus conventional Total Hip Arthroplasty (THA). This paper investigates the hypothesis that implant survival and PROMS following THAs performed with robotic assistance were not different to outcomes following conventional THAs. Data included all patients undergoing THA for osteoarthritis between 19 April 2016 and 31 December 2020. Analysis of PROMS outcomes was restricted to those who had completed PROMS data preoperatively and at 6 months postoperatively. There were 157,647 procedures, including 3567 robotically assisted procedures, available for comparison of revision rates. 4557 procedures, including 130 robotically assisted procedures, had PROMS data available. The revision rate of primary THA performed with robotic assistance was not statistically different from THA performed by conventional methods (4 year cumulative percent revision 3.1% v 2.7%; HR = 1.05, p=0.67). The Oxford Hip Score, VAS for pain and the EQ-VAS score for overall health showed no statistically significant difference between the groups. The EQ-5D Utility Score showed an improved score (median score 1 v 0.88; OR = 1.58, p=0.007) for the robotically assisted group compared to the conventional group. Robotic assisted THA was not associated with significant improvement in early revision or joint-specific PROMs. The findings may have been biased, in either direction, by unmeasured patient, surgeon, hospital and prosthesis factors. The findings (including the difference in health-related quality of life) may have also been influenced by lack of blinding. Future research should include methods to minimise these biases


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 58 - 58
23 Jun 2023
Fontalis A The CS Plastow R Mancino F Haddad FS
Full Access

In-hospital length of stay (LOS) and discharge disposition following arthroplasty could act as surrogate measures for improvement in patient pathways, and have major cost saving implications for healthcare providers. With the ever-growing adoption of robotic technology in arthroplasty, we wished to evaluate its impact on LOS. The objectives of this study were to compare LOS and discharge disposition following robotic-arm assisted (RO THA) versus conventional technique Total Hip Arthroplasty (CO THA). This large-scale, single institution study included patients of any age undergoing primary THA (N = 1,732) for any cause between May 2019 and January 2023. Data extracted included patient demographics, LOS, need for Post Anaesthesia Care Unit (PACU) admission, anaesthesia type, readmission within 30 days and discharge dispositions. Univariate and multivariate logistic regression models were also employed to identify factors and patient characteristics related to delayed discharge. The median LOS in the RO THA group was 54 hours (34, 78) versus 60 (51, 100) in the CO THA group, p<0.001. Discharge disposition was comparable between the two groups. In the multivariate model, age, need for PACU admission, ASA score > 2, female gender, general anaesthesia and utilisation of the conventional technique were significantly associated with LOS > 2 days. Our study showed that robotic-arm assistance was associated with a shorter LOS in patients undergoing primary THA and no difference in discharge destination. Our results suggest that robotic-arm assistance could be advantageous in partly addressing the upsurge of hip arthroplasty procedures and the concomitant health care burden; however, this needs to be corroborated by long-term cost effectiveness analyses and data from randomised controlled studies


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 6 - 6
1 May 2014
Dunbar M
Full Access

There has been a renewed interest in surface replacement arthroplasty over the last decade, with the hope and expectation that this procedure would provide an advantage over conventional total hip arthroplasty, especially in the young, active patient. More specifically, the promises of surface replacement arthroplasty have been: 1) preservation of bone stock so that future revisions would be easier, 2) potential to be minimally invasive in their approach, 3) better functional outcomes because of the stability associated with a larger femoral head with potential associated proprioceptive advantages, and 4) improved survivorship. Unfortunately, these promises have not been realised. Surface replacement arthroplasty does maintain more initial bone stock on the femur, but also tends to remove more bone initially on the acetabular side. Long term, it is the loss of acetabular bone stock that is more problematic from a reconstructive perspective. Further, the “simple” revision afforded in surface replacement arthroplasty has led to reports of inferior clinical outcomes, especially with respect to subjective complaints of pain. Surface replacement arthroplasty is more invasive than conventional total hip arthroplasty as the femoral head is maintained and the window to the acetabulum is subsequently partially blocked. This is exacerbated by the fact that many of these patients are young active males. There is no compelling evidence that surface replacement arthroplasty offers improved functional outcomes over conventional total hip arthroplasty, particularly when considering gait and proprioception. Some studies have in fact shown inferior outcomes. The concept of the larger femoral head in surface replacement arthroplasty providing increased range of motion and subsequent better function is flawed as it is the head-to-neck ratio that appears to be a more important determinant of outcome in this sense. Total hip arthroplasty generally has a more favorable ratio. Surface replacement arthroplasty has inferior survivorship to conventional total hip arthroplasty, even when accounting for the younger age of this patient cohort. This finding is consistent across multiple national joint replacement registries. The outcomes and survivorship are particularly poor in females, with many authors now advocating that the procedure be reserved for males. Surface replacement arthroplasty has introduced several new problems and mechanisms of failures, most concerning of which is the formation of pseudotumors in some patients. It is unclear as to who is at risk for this significant complication, and the ability to diagnose and treat this disorder is difficult and still in evolution. Likely associated is the significant elevation of metal ions in the serum and urine of some surface replacement arthroplasty patients. Neck fractures and loss of bone stock around the femoral implant have also been noted as problematic for these devices. Some of these problems have led to specific surface replacement arthroplasty systems being recalled. Finally, surface replacement arthroplasties are premium products with associated increased costs, which, frankly, are not justified


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 66 - 66
1 Oct 2019
Amstutz HC Duff MJL
Full Access

Introduction. Hip resurfacing arthroplasty (HRA) lost its popularity because of excessive wear of the ASR M/M design. Now that causes of wear have been identified, it remains an attractive treatment option for young patients because of its bone-conserving nature, the preservation of bone mineral density, a low dislocation rate, and its biomechanical precision. Methods. We assessed the long-term clinical outcomes of 1074 patients (1321 hips) who were implanted with hybrid Conserve. ®. Plus HRA, with 556 surgeries performed in patients younger than 50 years of age (average, 41.6 years) compared to 765 surgeries performed in patients 50 years or older (average, 58.1 years). 74% of the patients were male. There were no exclusion criteria. The <50 group had a larger proportion of dysplasia and hips operated during the first generation of surgical technique. Results. The mean elapse time after surgery was 15.6 years (range 7.4 to 22.5 years). We found no difference in UCLA pain, walking and function scores between the two groups except for a slightly higher activity level in the younger group (7.4 vs. 7.2, p=0.0172). Quality of life SF-12 scores were also comparable. Although we found better survivorship rates for the group of older patients (Log-rank test p=0.0107 – Figure 1) between the younger and older patients (Table 1), this difference was largely explained by the greater proportion of dysplasia (p=0.0001) and 1. st. generation hips (p=0.044) in the <50 group. The rate of post-operative complications (dislocations, sepsis, neve palsies, blood-related and others) was not significantly different between groups (p=0.3738). However, the complication rate dropped significantly (p=0.0390) in both groups from 6.4% for the first and 2. nd. generations of surgical technique (n=670) to 3.8% with the 3. rd. generation of surgical technique (n=651). Conclusions. The long-term results of metal-on-metal HRA meet and even surpass the original expectations in young and active adults, with survivorship rates far superior to those reported in registries for conventional total hip arthroplasty. However, the etiologic characteristics (particulartly hip dysplasia in women of small size, but not osteonecrosis) of this demanding population also affect the results of HRA with a lower survivorship compared with that of older patients. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 112 - 112
1 Apr 2019
Lage L
Full Access

We report a rare case of Hip Resurfacing dislocation three years after a bilateral Hip Resurfacing in a very strong patient and show the maneuver to do a closed reduction on a film done at the surgical theatre under general anesthesia. Hip resurfacing dislocation is a very rare entity described in the literature and more rare after three years. With conventional total hip replacement the dislocation rate is 2–5%. In the international literature the dislocation rate with resurfacing is 0.21%. We describe a case of a 47 years old male patient who was submitted to a biltateral 54 × 60 mm Hip Resurfacing in November 16 th and 18th, 2011 (two separate days). He had a normal post op and returned to his work after six weeks and recreational activities after four months. Three years later, on November 8th, 2014 he did an extreme movement of hip flexion, adduction and internal rotation when he was gardening and planting a tree seedling suffering a left hip dislocation. Hopefully we could reduce the dislocated hip in a closed manner in the following morning. Patient went home next day but on that same night had important abominal pain needing to return to hospital when numerous gallbladder stones where found being submitted to a total laparoscopic colecistectomy two days later. It was really a bad luck week. Metal ions are still normal and patient is symptomless until today having returned to his recreational activities. We will show in a movie the maneuver to do this closed reduction and hope by showing this maneuver that our colleagues do not have to do an open dislocation in the future in case they face a Hip Resurfacing dislocation


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 71 - 71
1 Apr 2018
Hood B Nelson J Lewis R Urquhart A Maratt J
Full Access

The purpose of this study is to assess the accuracy of component positioning and incidence of peri-operative and 90-day post-operative complications following robotic arm-assisted and conventional total hip arthroplasty (THA). Three groups of patients were analyzed for this study: those that underwent conventional THA performed by Surgeon 1, conventional THA performed by Surgeon 2, or robotic arm-assisted THA performed by Surgeon 2. All patients underwent primary uncemented THA via a posterior approach. Patient characteristics, intra-operative data, and 90-day post-operative complications were collected. Post-operative standing pelvic radiographs were utilized to measure acetabular position and to identify post-operative complications. Acetabular component position measurements revealed substantially less variation in both inclination and anteversion in the Surgeon 2 – Robotic group. Nine patients had intra-operative cables placed for intra-operative calcar fracture in the Surgeon 1 group compared to one patient and three patients in Surgeon 2 – Robotic and Surgeon 2 – Traditional groups, respectively. Nine instances of femoral stems subsidence were identified in the Surgeon 1 group compared to one patient in Surgeon 2 – Traditional. There were four instances of dislocation in the Surgeon 1 group compared to one in the Surgeon 2 – Robotic group. Robotic arm-assisted THA decreases the variation in acetabular component positioning compared to conventional THA. However, the benefit of this is unclear as there is little difference in dislocation rate. This study may demonstrate additional value in CT-based implant planning as this cohort had the lowest incidence of femoral component complications


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 500 - 500
1 Sep 2009
Ramasamy A Webb J Wallace I Port A McMurtry I
Full Access

Resurfacing arthroplasty is advantageous over conventional total hip arthroplasty in that femoral bone stock is preserved. However, there has been controversy over the preservation of acetabular bone stock in resurfacing arthroplasty, with the concern that it may result in excess reaming compared with total hip replacement. This is of concern as the prosthesis is primarily advocated in the young patient, who is likely to face future revision surgery. We prospectively identified a cohort of 68 patients with primary hip osteoarthritis undergoing conventional total hip arthroplasty. During surgery, the excised femoral head and neck diameter was measured, along with the diameter of the final acetabular reamer used to achieve a bed of bleeding cancellous bone. The measured neck diameter was then used to calculate the minimum possible resurfacing head and cup sizes, with corresponding final reamer sizes that could have been used in each patient without neck notching for both Birmingham Hip Resurfacing (BHR, Smith & Nephew, 3rd Generation) and Articular Surface replacement (ASR, De Puy, 4th Generation). Reaming diameter and volume was compared for all 3 groups. Mean reaming diameters for the THR, ASR and BHR groups were 51, 52 and 56mm respectively. Mean reaming volumes were 39, 40 and 47cc. There was a statistically significant difference between the THR and BHR groups for both reamed diameter and volume (p< 0.001). There was also a significant difference between the ASR and BHR groups for both reamed diameter and volume (p< 0.001). This difference was more pronounced with larger neck diameters. Our data shows that the BHR results in more ace-tabular bone loss compared to total hip replacement. An implant with a lower profile acetabular cup and a larger variety of sizes such as the ASR may allow better preservation of acetabular bone stock


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 134 - 141
1 Jan 2022
Cnudde PHJ Nåtman J Hailer NP Rogmark C

Aims

The aim of this study was to investigate the potentially increased risk of dislocation in patients with neurological disease who sustain a femoral neck fracture, as it is unclear whether they should undergo total hip arthroplasty (THA) or hemiarthroplasty (HA). A secondary aim was to investgate whether dual-mobility components confer a reduced risk of dislocation in these patients.

Methods

We undertook a longitudinal cohort study linking the Swedish Hip Arthroplasty Register with the National Patient Register, including patients with a neurological disease presenting with a femoral neck fracture and treated with HA, a conventional THA (cTHA) with femoral head size of ≤ 32 mm, or a dual-mobility component THA (DMC-THA) between 2005 and 2014. The dislocation rate at one- and three-year revision, reoperation, and mortality rates were recorded. Cox multivariate regression models were fitted to calculate adjusted hazard ratios (HRs).


Bone & Joint Open
Vol. 4, Issue 11 | Pages 853 - 858
10 Nov 2023
Subbiah Ponniah H Logishetty K Edwards TC Singer GC

Aims

Metal-on-metal hip resurfacing (MoM-HR) has seen decreased usage due to safety and longevity concerns. Joint registries have highlighted the risks in females, smaller hips, and hip dysplasia. This study aimed to identify if reported risk factors are linked to revision in a long-term follow-up of MoM-HR performed by a non-designer surgeon.

Methods

A retrospective review of consecutive MoM hip arthroplasties (MoM-HRAs) using Birmingham Hip Resurfacing was conducted. Data on procedure side, indication, implant sizes and orientation, highest blood cobalt and chromium ion concentrations, and all-cause revision were collected from local and UK National Joint Registry records.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 946 - 952
1 Sep 2023
Dhawan R Young DA Van Eemeren A Shimmin A

Aims

The Birmingham Hip Resurfacing (BHR) arthroplasty has been used as a surgical treatment of coxarthrosis since 1997. We present 20-year results of 234 consecutive BHRs performed in our unit.

Methods

Between 1999 and 2001, there were 217 patients: 142 males (65.4%), mean age 52 years (18 to 68) who had 234 implants (17 bilateral). They had patient-reported outcome measures collected, imaging (radiograph and ultrasound), and serum metal ion assessment. Survivorship analysis was performed using Kaplan-Meier estimates. Revision for any cause was considered as an endpoint for the analysis.


Bone & Joint Open
Vol. 4, Issue 3 | Pages 182 - 187
14 Mar 2023
Sheridan GA Hanlon M Welch-Phillips A Spratt K Hagan R O'Byrne JM Kenny PJ Kurmis AP Masri BA Garbuz DS Hurson CJ

Aims

Hip resurfacing remains a potentially valuable surgical procedure for appropriately-selected patients with optimised implant choices. However, concern regarding high early failure rates continues to undermine confidence in use. A large contributor to failure is adverse local tissue reactions around metal-on-metal (MoM) bearing surfaces. Such phenomena have been well-explored around MoM total hip arthroplasties, but comparable data in equivalent hip resurfacing procedures is lacking. In order to define genetic predisposition, we performed a case-control study investigating the role of human leucocyte antigen (HLA) genotype in the development of pseudotumours around MoM hip resurfacings.

Methods

A matched case-control study was performed using the prospectively-collected database at the host institution. In all, 16 MoM hip resurfacing 'cases' were identified as having symptomatic periprosthetic pseudotumours on preoperative metal artefact reduction sequence (MARS) MRI, and were subsequently histologically confirmed as high-grade aseptic lymphocyte-dominated vasculitis-associated lesions (ALVALs) at revision surgery. ‘Controls’ were matched by implant type in the absence of evidence of pseudotumour. Blood samples from all cases and controls were collected prospectively for high resolution genetic a nalysis targeting 11 separate HLA loci. Statistical significance was set at 0.10 a priori to determine the association between HLA genotype and pseudotumour formation, given the small sample size.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 74 - 74
1 Jan 2004
Barbosa JK Andrew JG
Full Access

Resurfacing total hip replacement using metal on metal bearings is increasing in popularity, but the outcomes are currently unclear. We report a series of 23 hips in 20 patients who underwent resurfacing total hip replacement over a period of 4 years. The mean age at surgery was 47 years (21–61). There were 8 females and 12 male patients. The mean follow up was 27 months (range 6 to 50 months). Before performing this study, our impression was that most outcomes were good but that there appeared to be more variability in pain relief than anticipated after conventional total hip replacement. Most were performed for primary osteoarthritis; other diagnoses included AVN, DDH and multiple epiphyseal dysplasia. Outcomes were measured examining x rays, survival of the implant and the Oxford hip questionnaire. There were no early revisions, but we are aware of one loose acetabular cup (in a patient with DDH) which is asymptomatic but which will probably require revision. There were no femoral neck fractures. The median score using the Oxford hip questionnaire was 15 (mean 23.5; range 12 to 41). These outcomes compare favourably with those reported at 6 months follow up after conventional total hip replacement by the Oxford group (OHQ median score 22; mean 24.3 (12 to 51)). We conclude that resurfacing metal on metal hip replacement gives comparable results to total hip replacement at early follow up. The age of the Oxford groups patients was considerably older than ours (75 years), and a comparative trial of resurfacing versus conventional hip replacements will be required to determine which gives better short and long term results in young patients. There may be more variability in pain relief after resurfacing THR than after conventional THR, but this will require a larger study to determine with confidence


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 11 - 18
1 Jan 2019
Kayani B Konan S Thakrar RR Huq SS Haddad FS

Objectives. The primary objective of this study was to compare accuracy in restoring the native centre of hip rotation in patients undergoing conventional manual total hip arthroplasty (THA) versus robotic-arm assisted THA. Secondary objectives were to determine differences between these treatment techniques for THA in achieving the planned combined offset, component inclination, component version, and leg-length correction. Materials and Methods. This prospective cohort study included 50 patients undergoing conventional manual THA and 25 patients receiving robotic-arm assisted THA. Patients undergoing conventional manual THA and robotic-arm assisted THA were well matched for age (mean age, 69.4 years (. sd. 5.2) vs 67.5 years (. sd. 5.8) (p = 0.25); body mass index (27.4 kg/m. 2. (. sd. 2.1) vs 26.9 kg/m. 2. (. sd. 2.2); p = 0.39); and laterality of surgery (right = 28, left = 22 vs right = 12, left = 13; p = 0.78). All operative procedures were undertaken by a single surgeon using the posterior approach. Two independent blinded observers recorded all radiological outcomes of interest using plain radiographs. Results. The correlation coefficient was 0.92 (95% confidence interval (CI) 0.88 to 0.95) for intraobserver agreement and 0.88 (95% CI 0.82 to 0.94) for interobserver agreement in all study outcomes. Robotic THA was associated with improved accuracy in restoring the native horizontal (p < 0.001) and vertical (p < 0.001) centres of rotation, and improved preservation of the patient’s native combined offset (p < 0.001) compared with conventional THA. Robotic THA improved accuracy in positioning of the acetabular component within the combined safe zones of inclination and anteversion described by Lewinnek et al (p = 0.02) and Callanan et al (p = 0.01) compared with conventional THA. There was no difference between the two treatment groups in achieving the planned leg-length correction (p = 0.10). Conclusion. Robotic-arm assisted THA was associated with improved accuracy in restoring the native centre of rotation, better preservation of the combined offset, and more precise acetabular component positioning within the safe zones of inclination and anteversion compared with conventional manual THA


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 57 - 57
1 Mar 2006
Sharma D Saeed Z Ramos J Hughes S
Full Access

Aims: To compare the results of resurfacing hip arthroplasty with conventional total hip replacement and to find out any differences in complication rates, discharge patterns and the resulting financial implications. Trial Design: Retrospective analysis comparing resurfacing hip arthroplasties to conventional total hip replacements in patients who were 65 years old or younger at the time of operation. Criteria for comparison were blood loss, post operative complications (including the need for blood transfusion), revision of arthroplasty and the length of hospital stay. Materials and Methods: All patients who had resurfacing arthroplasty in our hospital were included in the study (77 patients), and a similar group who had total hip replacements in the same time period were randomly selected for comparison. Case notes, computer records as well as X-rays were used to identify postoperative complications, especially DVT’s ,PE’s, neuro-vascular injuries, infection, fractured neck of femur and the need for revision of an arthroplasty. A detailed analysis of all revision arthroplasties including the causes, failure pattern of implant and the type of revision hip arthroplasty used and its cost implication was made. We also compared the pre and post-operative haemoglobin and units of blood transfused, if any. A comparison was also made of discharge pattern of these two groups of patients. A student t-test was performed to observe any difference in these two group. Results:. Resurface hip arthroplasty Group: Average age 52.1 years; pre-operative Hb 14.22gm/dl; postoperative Hb.10.95gm/dl; average blood loss 3.28 gm/dl; Total hips revised 12; Average length of stay 8.53 days. Total hip arthroplasty Group: Average age 58.8 years; pre-operative Hb 13.97gm/dl; post-operative Hb 10.65m/dl; average blood loss 3.5 gm/dl; Total hips revised 0; Average length of stay 8.9 days. Conclusions: 1.There were no appreciable differences between these two group as far as the usual complications, blood loss and length of stay are concerned. 2. There was appreciable difference in revision rate, which has significant cost implication for health authority and patients