The risk of AVN is high in Unstable Slipped Capital Femoral Epiphysis (SCFE) and the optimal surgical treatment remains controversial. Our AVN rates in severe, unstable SCFE remained unchanged following the introduction of the
In situ pinning for classic slipped capital femoral epiphysis(SLIP) is evolving to a more direct and anatomic realignment of proximal femoral epiphysis; but in no study the result of such a treatment in Valgus Slip, an uncommon type of slipped capital femoral epiphysis, has been reported. Three hips in three patients (one male, two female) with valgus SCFE were treated by sub-capital realignment (two hips) or femoral neck osteotomy (one hip) for anatomic realignment of proximal femoral epiphysis. Extended retinacular flap technique performed through surgical hip dislocation in all hips. They followed clinically by Merle d'Aubigne Scale and visual analog scale for pain and radiographically for AVN, recurrence of SLIP, chondrolysis and osteoarthritisIntroduction
Material and methods
The modified Dunn procedure has the potential to restore the anatomy in hips with slipped capital femoral epiphyses (SCFE) while protecting the blood supply to the femoral head. However, there is controversy about the risks associated with the procedure especially in the most severe capital slips. Therefore, we report on (1) clinical outcome, (2) the cumulative survivorship with endpoints AVN and/or OA progression and (3) radiographic anatomy of the proximal femur at followup in patients treated with a modified Dunn procedure for severe SCFE. We performed a retrospective analysis involving 46 hips of 46 patients treated with a modified Dunn procedure for severe SCFE (slip angle >60°) between 1999 and 2016. Followup averaged 8 years, (range 1–17) with 2 patients lost to followup after one year. The mean age was 13 years (range 9–19 years). Mean preoperative slip angle was 64° (range 60–90) and 14 out of 46 hips (30%) presented with unstable slips. Clinical scores and PROMs were evaluated and the hips were followed standard x-rays. Cumulative survivorship (Kaplan-Meier) with three defined endpoints: (1) AVN; (2) progression by at least one OA grade according to Tönnis; (3) non-preserved hip joint. (1)Mean Harris Hip score (HHS) was 93 points (66–100) and mean Hip Disability and Osteoarthritis Outcome Score (HOOS) was 90 points (67–100) at last followup. (2)Cumulative survivorship was 93% at 10-year followup. Three hips reached an endpoint. Two hips (4%) had AVN, one of them underwent hip arthrodesis. One hip had OA progression. (3)Postoperative slip angle was 7° (1–16). Alpha angle on axial radiograph was 39° (26–71) at followup. 41/44 hips (93%) had no OA (Tönnis 0). The modified Dunn procedure largely corrected slip deformities with low apparent risk of progression to avascular necrosis or osteoarthritis at mean 8-years followup. The AVN rate in severe and unstable (30%) capital slip was 4% (2 hips) with this procedure.
Hips following in-situ pinning for slipped capital femoral epiphysis (SCFE) have an altered morphology of the proximal femur with cam type deformity. This deformity can result in femoroacetabular impingement and early joint degeneration. The modified Dunn procedure allows to reorientate the slipped epiphysis to restore hip morphology and function. To evaluate (1) hip pain and function, (2) 10-year survival rate and (3) subsequent surgeries and complications in hips undergoing modified Dunn procedure for SCFE.Introduction
Objectives
The modified Dunn procedure has the potential to restore the anatomy in hips with severe slipped capital femoral epiphyses (SCFE). However, there is a risk of developing avascular necrosis of the femoral head (AVN). In this paper, we report on clinical outcome, radiological outcome, AVN rate and complications, and the cumulative survivorship at long-term follow-up in patients undergoing the modified Dunn procedure for severe SCFE. We performed a retrospective analysis involving 46 hips in 46 patients treated with a modified Dunn procedure for severe SCFE (slip angle > 60°) between 1999 and 2016. At nine-year-follow-up, 40 hips were available for clinical and radiological examination. Mean preoperative age was 13 years, and 14 hips (30%) presented with unstable slips. Mean preoperative slip angle was 64°. Kaplan–Meier survivorship was calculated.Aims
Patients and Methods
Chronic instability of the acromioclavicular joint is relatively common and normally occurs following a fall onto the point of the shoulder. Reconstruction of the joint (Weaver-Dunn procedure) is often required in service personnel, and numerous methods of fixation have been used, including vicryl tape, PDS loops and the use of a hook plate. Many of these operative methods require a second operation to remove the plates and/or screws, and are associated with a failure rate of up to 30%. The ‘Surgilig’ was designed as a method of revision for failed Weaver-Dunn procedures. However this study evaluates its use in the primary operation. We prospectively followed up the