header advert
Results 101 - 108 of 108
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1514 - 1520
1 Nov 2013
D’Agostino P Barbier O

The osteoinductive properties of demineralised bone matrix have been demonstrated in animal studies. However, its therapeutic efficacy has yet to be proven in humans. The clinical properties of AlloMatrix, an injectable calcium-based demineralised bone matrix allograft, were studied in a prospective randomised study of 50 patients with an isolated unstable distal radial fracture treated by reduction and Kirschner (K-) wire fixation. A total of 24 patients were randomised to the graft group (13 men and 11 women, mean age 42.3 years (20 to 62)) and 26 to the no graft group (8 men and 18 women, mean age 45.0 years (17 to 69)).

At one, three, six and nine weeks, and six and 12 months post-operatively, patients underwent radiological evaluation, assessments for range of movement, grip and pinch strength, and also completed the Disabilities of Arm, Shoulder and Hand questionnaire. At one and six weeks and one year post-operatively, bone mineral density evaluations of both wrists were performed.

No significant difference in wrist function and speed of recovery, rate of union, complications or bone mineral density was found between the two groups. The operating time was significantly higher in the graft group (p = 0.004). Radiologically, the reduction parameters remained similar in the two groups and all AlloMatrix extraosseous leakages disappeared after nine weeks.

This prospective randomised controlled trial did not demonstrate a beneficial effect of AlloMatrix demineralised bone matrix in the treatment of this category of distal radial fractures treated by K-wire fixation.

Cite this article: Bone Joint J 2013;95-B:1514–20.


The aims of this study were to assess the efficacy of a newly designed radiological technique (the radial groove view) for the detection of protrusion of screws in the groove for the extensor pollicis longus tendon (EPL) during plating of distal radial fractures. We also aimed to determine the optimum position of the forearm to obtain this view. We initially analysed the anatomy of the EPL groove by performing three-dimensional CT on 51 normal forearms. The mean horizontal angle of the groove was 17.8° (14° to 23°). We found that the ideal position of the fluoroscopic beam to obtain this view was 20° in the horizontal plane and 5° in the sagittal plane.

We then intra-operatively assessed the use of the radial groove view for detecting protrusion of screws in the EPL groove in 93 fractures that were treated by volar plating. A total of 13 protruding screws were detected. They were changed to shorter screws and these patients underwent CT scans of the wrist immediately post-operatively. There remained one screw that was protruding. These findings suggest that the use of the radial groove view intra-operatively is a good method of assessing the possible protrusion of screws into the groove of EPL when plating a fracture of the distal radius.

Cite this article: Bone Joint J 2013;95-B:1372–6.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1101 - 1105
1 Aug 2013
Haug LC Glodny B Deml C Lutz M Attal R

Penetration of the dorsal screw when treating distal radius fractures with volar locking plates is an avoidable complication that causes lesions of the extensor tendon in between 2% and 6% of patients. We examined axial fluoroscopic views of the distal end of the radius to observe small amounts of dorsal screw penetration, and determined the ideal angle of inclination of the x-ray beam to the forearm when making this radiological view.

Six volar locking plates were inserted at the wrists of cadavers. The actual screw length was measured under direct vision through a dorsal approach to the distal radius. Axial radiographs were performed for different angles of inclination of the forearm at the elbow.

Comparing axial radiological measurements and real screw length, a statistically significant correlation could be demonstrated at an angle of inclination between 5° and 20°. The ideal angle of inclination required to minimise the risk of implanting over-long screws in a dorsal horizon radiological view is 15°.

Cite this article: Bone Joint J 2013;95-B:1101–5.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1094 - 1100
1 Aug 2013
Baltzer H Binhammer PA

In Canada, Dupuytren's contracture is managed with partial fasciectomy or percutaneous needle aponeurotomy (PNA). Injectable collagenase will soon be available. The optimal management of Dupuytren’s contracture is controversial and trade-offs exist between the different methods. Using a cost-utility analysis approach, our aim was to identify the most cost-effective form of treatment for managing Dupuytren’s contracture it and the threshold at which collagenase is cost-effective. We developed an expected-value decision analysis model for Dupuytren’s contracture affecting a single finger, comparing the cost-effectiveness of fasciectomy, aponeurotomy and collagenase from a societal perspective. Cost-effectiveness, one-way sensitivity and variability analyses were performed using standard thresholds for cost effective treatment ($50 000 to $100 000/QALY gained). Percutaneous needle aponeurotomy was the preferred strategy for managing contractures affecting a single finger. The cost-effectiveness of primary aponeurotomy improved when repeated to treat recurrence. Fasciectomy was not cost-effective. Collagenase was cost-effective relative to and preferred over aponeurotomy at $875 and $470 per course of treatment, respectively.

In summary, our model supports the trend towards non-surgical interventions for managing Dupuytren’s contracture affecting a single finger. Injectable collagenase will only be feasible in our publicly funded healthcare system if it costs significantly less than current United States pricing.

Cite this article: Bone Joint J 2013;95-B:1094–1100.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 229 - 233
1 Mar 1999
Ramesh M Morrissey B Healy JB Roy-Choudhury S Macey AC

Acute swelling of the hand is a common problem after trauma or surgery and is associated with both pain and loss of function. We describe a prospective study of 47 patients in which we assessed the effects of a pneumatic compression device (A-V impulse hand pump) on the swollen hand. The pump reduced swelling by increasing the velocity of venous return as demonstrated by Duplex scanning of the median cubital vein.

Continuous use of the pump for 48 hours gave a reduction of 78.6% in swelling of the injured hand compared with the opposite, uninjured side. Even when used intermittently, with the pump on for 12 hours out of 24, a statistically significant effect was seen.

There was a subjective reduction in pain and an objective improvement in function of the hand. Use of the pump resulted in a nearly normal hand by the time of discharge from hospital after, on average, 48 hours.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 218 - 225
1 Mar 1999
Hamada K Fukuda H Nakajima T Yamada N

We reviewed 26 patients with 34 shoulders treated by the inferior capsular shift operation for inferior and multidirectional instability. The mean follow-up was 8.3 years. In total, 12 shoulders showed voluntary subluxation. Eight operations used an anterior and posterior approach, 11 were by the posterior route, and 15 shoulders had an anterior approach. In 30 shoulders (85%) the outcome was satisfactory and 20 (59%) scored good or excellent results on the Rowe system. Instability had recurred in nine shoulders (26%) from three months to three years after the operation. Six of the 12 shoulders with voluntary subluxation (50%) had recurrence, as against three of the other 22 (14%), a statistically significant difference. The operation is therefore not indicated for voluntary subluxation.

The 19 shoulders which had been assessed in 1987 at a mean of 3.5 years after surgery, were also reviewed in 1995 and found to have no significant changes in instability or Rowe score. This shows that the capsular shift appeared to have maintained its tension over an eight-year period. After the use of a posterior approach, 64% of the shoulders showed a posterolateral defect on radiographs of the humerus.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 212 - 217
1 Mar 1999
Bonnard C Anastakis DJ van Melle G Narakas AO

We have assessed the final strength of the deltoid in 121 patients who had repair of isolated or combined lesions of the axillary (circumflex) nerve and were available for statistical analysis. Successful or useful results were achieved in 85% after grafting of isolated lesions. The strength was statistically better when patients had grafting of the axillary nerve within 5.3 months from the time of injury. The dramatic decrease in the rate of success seen with longer delays suggests that surgery should be undertaken within three months of injury. A statistically significant downward trend of the rate of success was noted with increasing age. The force and level of injury to the shoulder play an important role in the type, combination and level of nerve damage and the incidence of associated rotator-cuff, vascular and other injuries to the upper limb. Management of isolated and combined lesions of the axillary nerve after injury to the shoulder needs to be thorough and systematic.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 226 - 228
1 Mar 1999
Bremner-Smith AT Unwin AJ Williams WW

We obtained samples of spinal accessory nerve from patients undergoing radical surgery for tumours or nerve grafting in the neck. These were analysed by light and electron microscopy for the type of fibre. All contained fibres consistent with non-proprioceptive sensory function including pain.