header advert
Results 41 - 60 of over 10000
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 25 - 25
1 Oct 2022
Casali M Rani N Cucurnia I Filanti M Coco V Reale D Zarantonello P Musiani C Zaffagnini M Romagnoli M
Full Access

Aim

Aim of this monocentric, prospective study was to evaluate the safety, efficacy, clinical and radiographical results at 24-month follow-up (N = 6 patients) undergoing hip revision surgery with severe acetabular bone defects (Paprosky 2C-3A-3B) using a combination of a novel phase-pure betatricalciumphosphate - collagen 3D matrix with allograft bone chips.

Method

Prospective follow-up of 6 consecutive patients, who underwent revision surgery of the acetabular component in presence of massive bone defects between April 2018 and July 2019. Indications for revision included mechanical loosening in 4 cases and history of hip infection in 2 cases. Acetabular deficiencies were evaluated radiographically and CT and classified according to the Paprosky classification. Initial diagnosis of the patients included osteoarthritis (N = 4), a traumatic fracture and a congenital hip dislocation. 5 patients underwent first revision surgery, 1 patient underwent a second revision surgery.


Full Access

Abstract

Background

The gold standard treatment for Anterior Cruciate Ligament injury is reconstruction (ACL-R). Graft failure is the concern and ensuring a durable initial graft with rapid integration is crucial. Graft augmentation with implantable devices (internal brace reinforcement) is a technique purported to reduce the risk of rupture and hasten recovery. We aim to compare the short-term outcome of ACL-R using augmented hamstring tendon autografts (internally braced with neoligament) and non-augmented hamstring autografts.

Methods

This was a retrospective cohort study comparing augmented and non-augmented ACL-R. All procedures were performed in a single centre using the same technique. The Knee injury and Osteoarthritis Outcome Score [KOOS] was used to assess patient-reported outcomes.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 27 - 27
1 Oct 2022
Vittrup S Jensen LK Hanberg P Slater J Hvistendahl MA Stilling M Jørgensen N Bue M
Full Access

Aim

This study investigated if co-administration of rifampicin with moxifloxacin led to a decrease in moxifloxacin concentrations in relevant tissues in a porcine model of implant-associated osteomyelitis caused S. aureus. Pharmacokinetics were measured using microdialysis and treatment effect was measured by quantifying bacterial load from implant and periprosthetic bone following a 1-stage revision and antibiotics.

Method

15 female pigs received a stainless-steel implant in the right proximal tibia and were randomized into two groups. Infection was introduced by inoculating the implant with Staphylococcus aureus as previously described1. On day 7 post surgery, all pigs were revised with implant removal, debridement of implant cavity and insertion of a sterile implant. 7 days of treatment was then initiated with either moxifloxacin 400 mg iv q.d. (M) or moxifloxacin and rifampicin 450 mg iv b.i.d. (RM). At day 14, animals were sedated and microdialysis was applied for continuous sampling of moxifloxacin concentrations during 8 h in five compartments: the implant cavity, cancellous bone in both the infected and non-infected proximal tibia, and adjacent subcutaneous tissue on both the infected and non-infected side using a previously described setup2. Venous blood samples were collected. Implant and adjacent bone were removed for analysis.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 31 - 31
1 Dec 2022
Ambrosio L Vadalà G Russo F Donnici L Di Tecco C Iavicoli S Papalia R Denaro V
Full Access

With the coronavirus disease 2019 (COVID-19) pandemic, remote working has been ubiquitously implemented to reduce disease transmission via minimization of in-person interactions. Low back pain (LBP) is the first cause of disability worldwide and is frequently reported by workers with sedentary occupations. This cross-sectional study aimed to assess the role of remote working in a population of adults affected by LBP through an online questionnaire.

We enrolled 136 teleworkers affected by LBP. A total of 101 responses were received and 93 suitable questionnaires were included in the final analysis. Demographic data, remote working features and tasks, and LBP burden were analysed. The psychological burden of remote working was evaluated with the World Health Organization Five Well-Being Index (WHO-5) and the Patient Health Questionnaire-2 (PHQ-2). LBP severity was evaluated using a visual analog scale (VAS). LBP-related disability was assessed using the Oswestry Disability Index (ODI). The effect of LBP on working capacity was examined with the Occupational Role Questionnaire (ORQ). Independent risk factors related to LBP worsening were identified using a multivariate logistic regression model.

LBP severity was significantly higher compared to previous in-person working (p<0.0001) as well as average weekly work hours (p<0.001). Furthermore, the risk of LBP deterioration was associated with being divorced (OR: 4.28, 95% CI: 1.27-14.47; p=0.019) or living with others (OR: 0.24, 95% CI: 0.07-0.81; p=0.021), higher ill-being (OR: 0.91, 95% CI: 0.83-0.99; p=0.035) and depression scores (OR: 1.38, 95% CI: 1.00-1.91; p=0.048), as well as having reported unchanged (OR: 0.22, 95% CI: 0.08-0.65; p=0.006) or decreased job satisfaction (OR: 0.16, 95% CI: 0.05-0.54; p=0.003) and increased stress levels (OR: 3.00, 95% CI: 1.04-8.65; p=0.042).

These findings highlight key factors to consider for improving remote workers’ physical and mental wellbeing and decrease their LBP burden.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 52 - 52
1 Dec 2022
Moskven E Lasry O Singh S Flexman A Fisher C Street J Boyd M Ailon T Dvorak M Kwon B Paquette S Dea N Charest-Morin R
Full Access

En bloc resection for primary bone tumours and isolated metastasis are complex surgeries associated with a high rate of adverse events (AEs). The primary objective of this study was to explore the relationship between frailty/sarcopenia and major perioperative AEs following en bloc resection for primary bone tumours or isolated metastases of the spine. Secondary objectives were to report the prevalence and distribution of frailty and sarcopenia, and determine the relationship between these factors and length of stay (LOS), unplanned reoperation, and 1-year postoperative mortality in this population.

This is a retrospective study of prospectively collected data from a single quaternary care referral center consisting of patients undergoing an elective en bloc resection for a primary bone tumour or an isolated spinal metastasis between January 1st, 2009 and February 28th, 2020. Frailty was calculated with the modified frailty index (mFI) and spine tumour frailty index (STFI). Sarcopenia, determined by the total psoas area (TPA) vertebral body (VB) ratio (TPA/VB), was measured at L3 and L4. Regression analysis produced ORs, IRRs, and HRs that quantified the association between frailty/sarcopenia and major perioperative AEs, LOS, unplanned reoperation and 1-year postoperative mortality.

One hundred twelve patients met the inclusion criteria. Using the mFI, five patients (5%) were frail (mFI ³ 0.21), while the STFI identified 21 patients (19%) as frail (STFI ³ 2). The mean CT ratios were 1.45 (SD 0.05) and 1.81 (SD 0.06) at L3 and L4 respectively. Unadjusted analysis demonstrated that sarcopenia and frailty were not significant predictors of major perioperative AEs, LOS or unplanned reoperation. Sarcopenia defined by the CT L3 TPA/VB and CT L4 TPA/VB ratios significantly predicted 1-year mortality (HR of 0.32 per one unit increase, 95% CI 0.11-0.93, p=0.04 vs. HR of 0.28 per one unit increase, 95% CI 0.11-0.69, p=0.01) following unadjusted analysis. Frailty defined by an STFI score ≥ 2 predicted 1-year postoperative mortality (OR of 2.10, 95% CI 1.02-4.30, p=0.04).

The mFI was not predictive of any clinical outcome in patients undergoing en bloc resection for primary bone tumours or isolated metastases of the spine. Sarcopenia defined by the CT L3 TPA/VB and L4 TPA/VB and frailty assessed with the STFI predicted 1-year postoperative mortality on univariate analysis but not major perioperative AEs, LOS or reoperation. Further investigation with a larger cohort is needed to identify the optimal measure for assessing frailty and sarcopenia in this spine population.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 49 - 49
1 Jul 2022
Hickland P Cassidy R Diamond O Napier R
Full Access

Abstract

Introduction

Cementless total knee arthroplasty (TKA) offers a number of conceptual benefits including osteointegration, bone preservation and reduced aseptic loosening from third body wear. Evidence of equivalence to cemented fixation exists, but the cam-post interaction of posterior-stabilised (PS)-TKA on implant osteointegration remains uncertain. This study aims to assess the survivorship of a single prosthesis PS-TKA.

Methodology

All patients undergoing a PS-TKA using the Triathlon Total Knee System (Stryker Orthopaedics, USA) between 01/01/2010 and 08/04/2019, with exposure to at least 2 years’ risk of revision were identified from the hospital database.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 58 - 58
1 Dec 2022
Lemieux V Afsharpour S Nam D Elmaraghy A
Full Access

Operative management of clavicle fractures is increasingly common. In the context of explaining the risks and benefits of surgery, understanding the impact of incisional numbness as it relates to the patient experience is key to shared decision making. This study aims to determine the prevalence, extent, and recovery of sensory changes associated with supraclavicular nerve injury after open reduction and plate internal fixation of middle or lateral clavicle shaft fractures.

Eighty-six patients were identified retrospectively and completed a patient experience survey assessing sensory symptoms, perceived post-operative function, and satisfaction. Correlations between demographic factors and outcomes, as well as subgroup analyses were completed to identify factors impacting patient satisfaction.

Ninety percent of patients experienced sensory changes post-operatively. Numbness was the most common symptom (64%) and complete resolution occurred in 32% of patients over an average of 19 months. Patients who experienced burning were less satisfied overall with the outcome of their surgery whereas those who were informed of the risk of sensory changes pre-operatively were more satisfied overall.

Post-operative sensory disturbance is common. While most patients improve, some symptoms persist in the majority of patients without significant negative effects on satisfaction. Patients should always be advised of the risk of persistent sensory alterations around the surgical site to increase the likelihood of their satisfaction post-operatively.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 19 - 19
1 Oct 2022
Schenk HM Sebillotte M Lomas J Taylor A Benavent E Murillo O Fernandez-Sampedro M Huotari K Aboltins C Trebse R Soriano A Wouthuyzen-Bakker M
Full Access

Aim

Patients with late acute periprosthetic joint infections (PJI) and treated with surgical debridement have a high failure rate. Previous studies have shown that rheumatoid arthritis (RA) is an independent risk factor for treatment failure. We conducted a case-control study to identify predictors for failure in late acute PJI treatment in RA patients. We hypothesize that patients with RA have a higher failure rate compared to controls due to the use of immunosuppressive drugs.

Method

Data of an international multicenter retrospective observational study was used. Late acute PJI was defined as a sudden onset of symptoms and signs of a PJI, more than 3 months after implantation. Failure of treatment was defined as persistent signs of infection, relapse with the same or reinfection with a different micro-organism, need for prosthesis removal or death. Cases with RA were matched with cases without RA based on the affected joint. A Cox survival analyses, stratified for RA, was used to calculate hazard ratio's (HR) for failure. Subgroup analyses were used to explore other predictors for treatment failure in RA patients.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 24 - 24
1 Dec 2022
Trisolino G Frizziero L Santi GM Alessandri G Liverani A Menozzi GC Depaoli A Martinelli D Di Gennaro GL Vivarelli L Dallari D
Full Access

Paediatric musculoskeletal (MSK) disorders often produce severe limb deformities, that may require surgical correction. This may be challenging, especially in case of multiplanar, multifocal and/or multilevel deformities. The increasing implementation of novel technologies, such as virtual surgical planning (VSP), computer aided surgical simulation (CASS) and 3D-printing is rapidly gaining traction for a range of surgical applications in paediatric orthopaedics, allowing for extreme personalization and accuracy of the correction, by also reducing operative times and complications. However, prompt availability and accessible costs of this technology remain a concern. Here, we report our experience using an in-hospital low-cost desk workstation for VSP and rapid prototyping in the field of paediatric orthopaedic surgery.

From April 2018 to September 2022 20 children presenting with congenital or post-traumatic deformities of the limbs requiring corrective osteotomies were included in the study. A conversion procedure was applied to transform the CT scan into a 3D model. The surgery was planned using the 3D generated model. The simulation consisted of a virtual process of correction of the alignment, rotation, lengthening of the bones and choosing the level, shape and direction of the osteotomies. We also simulated and calculated the size and position of hardware and customized massive allografts that were shaped in clean room at the hospital bone bank. Sterilizable 3D models and PSI were printed in high-temperature poly-lactic acid (HTPLA), using a low-cost 3D-printer.

Twenty-three operations in twenty patients were performed by using VSP and CASS. The sites of correction were: leg (9 cases) hip (5 cases) elbow/forearm (5 cases) foot (5 cases) The 3D printed sterilizable models were used in 21 cases while HTPLA-PSI were used in five cases. customized massive bone allografts were implanted in 4 cases. No complications related to the use of 3D printed models or cutting guides within the surgical field were observed. Post-operative good or excellent radiographic correction was achieved in 21 cases.

In conclusion, the application of VSP, CASS and 3D-printing technology can improve the surgical correction of complex limb deformities in children, helping the surgeon to identify the correct landmarks for the osteotomy, to achieve the desired degree of correction, accurately modelling and positioning hardware and bone grafts when required. The implementation of in-hospital low-cost desk workstations for VSP, CASS and 3D-Printing is an effective and cost-advantageous solution for facilitating the use of these technologies in daily clinical and surgical practice.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 33 - 33
1 Nov 2022
Haleem S Choudri J Parker M
Full Access

Abstract

Introduction

The management of hip fractures has advanced on all aspects from prevention, specialised hip fracture units, early operative intervention and rehabilitation in line with increasing incidence in an aging population. Accurate data analysis on the incidence and trends of hip fractures is imperative to guide future management planning.

Methods

A review of all articles published on mortality after hip fracture over a twenty year period (1999–2018) was undertaken to determine any changes that had occurred in the demographics and mortality over this period. This article complements and expands upon the findings of a previous article by the authors assessing a four decade period (1959 – 1998) and attempts to present trends and geographical variations over sixty years.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 35 - 35
1 Nov 2022
Bommireddy L Daoud H Morris D Espag M Tambe A Clark D
Full Access

Abstract

Introduction

In our quality improvement project we implemented a novel pathway, performing acute fixation in mid-third clavicle fractures with >15% shortening. Patients with <15% shortening reviewed at 6 weeks, non-union risk identified as per Edinburgh protocol and decision to operate made accordingly.

Methods

Retrospective pre-pathway analysis of patients presenting 04/2017–04/2019. Prospective post-pathway analysis of patients presenting 10/2020–10/2021. Fracture shortening measured using Matsumura technique. QuickDASH and recovery questionnaires posted to >15% shortening patients and done post-pathway at 3 months.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 47 - 47
1 Dec 2022
Cherry A Eseonu K Ahn H
Full Access

Lumbar fusion surgery is an established procedure for the treatment of several spinal pathologies. Despite numerous techniques and existing devices, common surgical trends in lumbar fusion surgery are scarcely investigated. The purpose of this Canada-based study was to provide a descriptive portrait of current surgeons’ practice and implant preferences in lumbar fusion surgery while comparing findings to similar investigations performed in the United Kingdom.

Canadian Spine Society (CSS) members were sampled using an online questionnaire which was based on previous investigations performed in the United Kingdom. Fifteen questions addressed the various aspects of surgeons’ practice: fusion techniques, implant preferences, and bone grafting procedures. Responses were analyzed by means of descriptive statistics.

Of 139 eligible CSS members, 41 spinal surgeons completed the survey (29.5%). The most common fusion approach was via transforaminal lumber interbody fusion (TLIF) with 87.8% performing at least one procedure in the previous year. In keeping with this, 24 surgeons (58.5%) had performed 11 to 50 cases in that time frame. Eighty-six percent had performed no lumbar artificial disc replacements over their last year of practice. There was clear consistency on the relevance of a patient specific management (73.2%) on the preferred fusion approach. The most preferred method was pedicle screw fixation (78%). The use of stand-alone cages was not supported by any respondents. With regards to the cage material, titanium cages were the most used (41.5%). Published clinical outcome data was the most important variable in dictating implant choice (87.8%). Cage thickness was considered the most important aspect of cage geometry and hyperlordotic cages were preferred at the lower lumbar levels. Autograft bone graft was most commonly preferred (61.0%). Amongst the synthetic options, DBX/DBM graft (64.1%) in injectable paste form (47.5%) was preferred.

In conclusion, findings from this study are in partial agreement with previous work from the United Kingdom, but highlight the variance of practice within Canada and the need for large-scale clinical studies aimed to set specific guidelines for certain pathologies or patient categories.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 28 - 28
1 Dec 2022
Brodano GB
Full Access

Adverse events (AEs) are still a major problem in spinal surgery, despite advances in surgical techniques, innovative technologies available and the introduction of checklist and predictive score systems aimed at reducing surgical complications.

We previously analysed the results of the introduction of the WHO Safety Surgical Checklist (SSC) in our Institution, comparing the incidence of complications between two periods: from January to December 2010 (without checklist) and from January 2011 and December 2012 (with checklist), in order to assess the checklist effectiveness.

The sample size was 917 patients with an average of 30 months of follow-up. Complications were observed in 107 patients (11.6%) among 917 spinal surgery procedures performed, with 159 (17.3%) complications in total. The overall incidence of complications for trauma, infectious pathology, oncology, and degenerative disease was 22.2%, 19.2%, 18.4%, and 15.3%, respectively. We observed a reduction of the overall incidence of complications following the introduction of the WHO Surgical Checklist: in 2010 without checklist, the incidence of complications was 24.2%, while in 2011 and 2012, following the checklist introduction, the incidence of complications was 16.7% and 11.7%, respectively (mean 14.2%) (p<0.0005).

Thus, the SSC appeared to be an effective tool to reduce complications in spinal surgery and we proposed to extend the use of checklist system also to the pre-operative and post-operative phases in order to further reduce the incidence of complications.

We also believe that a correct capture and classification of complications is fundamental to generate a clinical decision support system aimed at improving patients’ safety in spinal surgery.

In the period between January 2017 and January 2018 we prospectively recorded the adverse events and complications of patients undergoing spinal surgery in our department, without using any collection system. Then we retrospectively recorded the intraoperative and postoperative adverse events of surgically treated patients during the same one-year period, using the SAVES v2 system introduced by Rampersaud and collaborators (Rampersaud YR et al. J Neurosurg Spine 2016 Aug; 25 (2): 256-63) to classify them.

In the one-year period from January 2017 to January 2018 a total of 336 patients underwent spinal surgery: 223 for degenerative conditions and 113 for spinal tumors. Comorbidities were collected (Charlson Comorbidity Index [CCI]).

Overall, a higher number of adverse events (AEs) was recorded using SAVES compared to the prospective recording without the use of any capture system and the increased number was statistically significant for early postoperative AEs (138/336 vs 44/336, p<0.001).

210 adverse events were retrospectively recorded using the SAVES system (30 intraoperative adverse events, 138 early postoperative and 42 late postoperative adverse events). 99 patients (29.5%) on the cohort had at least one complication.

Furthermore, the correlation between some risk factors and the onset of complications or the prolonged length of stay was statistically analyzed. The risk factors taken into account were: age, presence of comorbidities (CCI), ASA score, previous surgery at the same level, type of intervention, location of the disease, duration of the surgery.

In particular, the duration of the surgery (more than 3 hours) and the presence of previous surgeries resulted to be risk factors for complications in multivariate analyses


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 81 - 81
1 Dec 2022
Straatman L Walton D Lalone E
Full Access

Pain and disability following wrist trauma are highly prevalent, however the mechanisms underlying painare highly unknown. Recent studies in the knee have demonstrated that altered joint contact may induce changes to the subchondral bone density and associated pain following trauma, due to the vascularity of the subchondral bone. In order to examine these changes, a depth-specific imaging technique using quantitative computed tomography (QCT) has been used. We've demonstrated the utility of QCT in measuring vBMD according to static jointcontact and found differences invBMD between healthy and previously injured wrists. However, analyzing a static joint in a neutral position is not necessarily indicative of higher or lower vBMD. Therefore, the purposeof this study is to explore the relationship between subchondral vBMDand kinematic joint contact using the same imaging technique.

To demonstrate the relationship between kinematic joint contact and subchondral vBMDusing QCT, we analyzed the wrists of n = 10 participants (n = 5 healthy and n = 5 with previous wrist trauma). Participantsunderwent 4DCT scans while performing flexion to extension to estimate radiocarpal (specifically the radiolunate (RL) and radioscaphoid (RS)) joint contact area (JCa) between the articulating surfaces. The participantsalso underwent a static CT scan accompanied by a calibration phantom with known material densities that was used to estimate subchondral vBMDof the distal radius. Joint contact is measured by calculatinginter-bone distances (mm2) using a previously validated algorithm. Subchondral vBMD is presented using mean vBMD (mg/K2HPO4) at three normalized depths from the subchondral surface (0 to 2.5, 2.5 to 5 and 5 to 7.5 mm) of the distal radius.

The participants in the healthy cohort demonstrated a larger JCa in the RS joint during both extension and flexion, while the trauma cohort demonstrated a larger JCa in the RL during extension and flexion. With regards to vBMD, the healthy cohort demonstrated a higher vBMD for all three normalized depths from the subchondral surface when compared to the trauma cohort.

Results from our preliminary analysis demonstrate that in the RL joint specifically, a larger JCa throughout flexion and extension was associated with an overall lower vBMD across all three normalized layers. Potential reasoning behind this association could be that following wrist trauma, altered joint contact mechanics due to pathological changes (for example, musculoskeletal trauma), has led to overloading in the RL region. The overloading on this specific region may have led to a decrease in the underlying vBMD when compared to a healthy wrist. However, we are unable to conclude if this is a momentary decrease in vBMD that could be associated with the acute healing phase following trauma given that our analysis is cross-sectional. Therefore, future work should aim to analyze kinematic JCa and vBMD longitudinally to better understand how changes in kinematic JCa over time, and how the healing process following wrist trauma, impacts the underlying subchondral bone in the acute and longitudinal phases of recovery.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 82 - 82
1 Dec 2022
Hitchon S Milner J Holdsworth D Willing R
Full Access

Revision surgeries for orthopaedic infections are done in two stages – one surgery to implant an antibiotic spacer to clear the infection and another to install a permanent implant. A permanent porous implant, that can be loaded with antibiotics and allow for single-stage revision surgery, will benefit patients and save healthcare resources. Gyroid structures can be constructed with high porosity, without stress concentrations that can develop in other period porous structures [1] [2]. The purpose of this research is to compare the resulting bone and prosthesis stress distributions when porous versus solid stems are implanted into three proximal humeri with varying bone densities, using finite element models (FEM).

Porous humeral stems were constructed in a gyroid structure at porosities of 60%, 70%, and 80% using computer-aided design (CAD) software. These CAD models were analyzed using FEM (Abaqus) to look at the stress distributions within the proximal humerus and the stem components with loads and boundary conditions representing the arm actively maintained at 120˚ of flexion. The stem was assumed to be made of titanium (Ti6Al4V). Three different bone densities were investigated, representing a healthy, an osteopenic, and an osteoporotic humerus, with an average bone shape created using a statistical shape and density model (SSDM) based on 75 cadaveric shoulders (57 males and 18 females, 73 12 years) [3]. The Young's moduli (E) of the cortical and trabecular bones were defined on an element-by-element basis, with a minimum allowable E of 15 MPa. The Von Mises stress distributions in the bone and the stems were compared between different stem scenarios for each bone density model.

A preliminary analysis shows an increase in stress values at the proximal-lateral region of the humerus when using the porous stems compared to the solid stem, which becomes more prominent as bone density decreases. With the exception of a few mesh dependent singularities, all three porous stems show stress distributions below the fatigue strength of Ti-6Al-4V (410 MPa) for this loading scenario when employed in the osteopenic and osteoporotic humeri [4]. The 80% porosity stem had a single strut exceeding the fatigue strength when employed in the healthy bone.

The results of this study indicate that the more compliant nature of the porous stem geometries may allow for better load transmission through the proximal humeral bone, better matching the stress distributions of the intact bone and possibly mitigating stress-shielding effects. Importantly, this study also indicates that these porous stems have adequate strength for long-term use, as none were predicted to have catastrophic failure under the physiologically-relevant loads. Although these results are limited to a single boney geometry, it is based on the average shape of 75 shoulders and different bone densities are considered. Future work could leverage the shape model for probabilistic models that could explore the effect of stem porosity across a broader population. The development of these models are instrumental in determining if these structures are a viable solution to combatting orthopaedic implant infections.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 46 - 46
1 Oct 2022
Porcellini G Giorgini A Montanari M
Full Access

Aim

Studies have shown that retention of antibiotic cement spacer in selected elderly patients with low functional demand represents a viable option for periprosthetic joint infections (PJI) treatment1,2.

The aim of this study is to compare the efficacy in infection treating among modular taylored preformed and hand-made antibiotic spacers. Our hypothesis is that modular tailored preformed spacer provides a better rate of infection resolution, better radiological and functional outcomes compared to hand-made spacers.

Materials and methods

We identified 48 patients treated with antibiotic cement spacer for shoulder chronic infection between 2015 and 2021 in our institution; (13 hand-made spacers and 35 modular tailored preformed spacers). We collected data about comorbidities, associated microorganism, infection resolution, clinical and radiographic evaluation.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 70 - 70
1 Dec 2022
Falsetto A Grant H Wood G
Full Access

Arthroscopic hip procedures have increased dramatically over the last decade as equipment and techniques have improved. Patients who require hip arthroscopy for femoroacetabular impingement on occasion require surgery on the contralateral hip. Previous studies have found that younger age of presentation and lower Charlson comorbidity index have higher risk for requiring surgery on the contralateral hip but have not found correlation to anatomic variables. The purpose of this study is to evaluate the factors that predispose a patient to requiring subsequent hip arthroscopy on the contralateral hip.

This is an IRB-approved, single surgeon retrospective cohort study from an academic, tertiary referral centre. A chart review was conducted on 310 primary hip arthroscopy procedures from 2009-2020. We identified 62 cases that went on to have a hip arthroscopy on the contralateral side. The bilateral hip arthroscopy cohort was compared to unilateral cohort for sex, age, BMI, pre-op alpha angle and centre edge angle measured on AP pelvis XRay, femoral torsion, traction time, skin to skin time, Tonnis grade, intra-op labral or chondral defect. A p-value <0.05 was deemed significant.

Of the 62 patients that required contralateral hip arthroscopy, the average age was 32.7 compared with 37.8 in the unilateral cohort (p = 0.01) and BMI was lower in the bilateral cohort (26.2) compared to the unilateral cohort (27.6) (p=0.04). The average alpha angle was 76.30 in the bilateral compared to 660 in the unilateral cohort (p = 0.01). Skin to skin time was longer in cases in which a contralateral surgery was performed (106.3 mins vs 86.4 mins) (p=0.01). Interestingly, 50 male patients required contralateral hip arthroscopy compared to 12 female patients (p=0.01). No other variables were statistically significant.

In conclusion, this study does re-enforce existing literature by stating that younger patients are more likely to require contralateral hip arthroscopy. This may be due to the fact that these patients require increased range of motion from the hip joint to perform activities such as sports where as older patients may not need the same amount of range of motion to perform their activities. Significantly higher alpha angles were noted in patients requiring contralateral hip arthroscopy, which has not been shown in previous literature. This helps to explain that larger CAM deformities will likely require contralateral hip arthroscopy because these patients likely impinge more during simple activities of daily living. Contralateral hip arthroscopy is also more common in male patients who typically have a larger CAM deformity. In summary, this study will help to risk stratify patients who will likely require contralateral hip arthroscopy and should be a discussion point during pre-operative counseling. That offering early subsequent or simultaneous hip arthroscopy in young male patients with large CAMs should be offered when symptoms are mild.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 12 - 12
1 Nov 2022
Naskar R Shahid M
Full Access

Abstract

INTRODUCTION

With increasing use of fluoroscopy in Orthopaedic theatres in recent years, the occupational radiation exposure to the surgeons and the theatre staff has increased significantly. Thyroid is one of the most radio-sensitive tissues in the body, but there is a clear lack of awareness among theatre staff of risks of radiation to thyroid.

METHODS

We prospectively reviewed the use of thyroid shield by the theatre staff in the orthopaedic theatre for two weeks period. We also recorded the number of fluoroscopic images taken and total radiation dosage for each case.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 22 - 22
1 Dec 2022
Werle J Kearns S Bourget-Murray J Johnston K
Full Access

A concern of metal on metal hip resurfacing arthroplasty is long term exposure to Cobalt (Co) and Chromium (CR) wear debris from the bearing. This study compares whole blood metal ion levels from patients drawn at one-year following Birmingham Hip Resurfacing (BHR) to levels taken at a minimum 10-year follow-up.

A retrospective chart review was conducted to identify all patients who underwent a BHR for osteoarthritis with a minimum 10-year follow-up. Whole blood metal ion levels were drawn at final follow-up in June 2019. These results were compared to values from patients with one-year metal ion levels.

Of the 211 patients who received a BHR, 71 patients (54 males and 17 females) had long term metal ion levels assessed (mean follow-up 12.7 +/− 1.4 years). The mean Co and Cr levels for patients with unilateral BHRs (43 males and 13 females) were 3.12 ± 6.31 ug/L and 2.62 ± 2.69 ug/L, respectively, and 2.78 ± 1.02 ug/L and 1.83 ± 0.65 ug/L for patients with bilateral BHRs (11 males and 4 females). Thirty-five patients (27 male and 8 female) had metal-ion levels tested at one-year postoperatively. The mean changes in Co and Cr levels were 2.29 ug/l (p = 0.0919) and 0.57 (p = 0.1612), respectively, at one year compared to long-term. These changes were not statistically significant.

This study reveals that whole blood metal ion levels do not change significantly when comparing one-year and ten-year Co and Cr levels. These ion levels appear to reach a steady state at one year.

Our results also suggest that regular metal-ion testing as per current Medicines and Healthcare products Regulatory Agency (MHRA) guidelines may be impractical for asymptomatic patients. Metal-ion levels, in and of themselves, may in fact possess little utility in determining the risk of failure and should be paired with radiographic and clinical findings to determine the need for revision.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 79 - 79
1 Oct 2022
Bernaus M Cubillos YL Soto S Bermúdez A Calero JA Torres D Veloso M Font-Vizcarra L
Full Access

Aim

To evaluate the efficiency of pulse lavage combined with electrical fields to remove biofilm from a metallic surface.

Method

Using a 12-well culture plate designed for the application of electrical fields, strains of S. epidermidis were incubated at each well for 24 hours at 37ºC. After incubation, supernatant culture medium was removed, and each well was filled with 3ml of normal saline. Six different models were compared: a) control, b) low-pressure pulse lavage, c) high-pressure pulse lavage, d) pulsed electrical fields, e) low-pressure pulse lavage in combination with pulsed electrical fields, and f) high-pressure pulse lavage in combination with pulsed electrical fields. In all cases, exposure time was set to 25 seconds. In the electrical field models, 50 pulses were applied.

After exposure, each bottom electrode was scraped carefully to release adhered bacteria. Subsequently, different dilutions of biofilm removed were spread onto Müller Hinton agar plates and incubated for 24h at 37 ºC, and colony-forming units (CFU) per milliliters were counted. Bacterial counts were then compared to the control model.