Advances in total hip and knee replacement technologies have heretofore been largely driven by corporate marketing hype with each seeming advancement accompanied by a cost increase often out in front of peer-reviewed reports documenting their efficacy or not.

As example, consider the growing use of ceramic femoral heads in primary total hip arthroplasty (THA). The question to consider is “Can an upcharge of $350 for a ceramic femoral head in primary THA be justified?” The answer to this question lies in an appreciation of whether the technology modifies the potential for costly revision arthroplasty procedures.

Peer-Reviewed Laboratory & Clinical Review - According to the 2022 Australian National Joint Replacement Registry, the four leading causes of primary THA failure requiring revision are: 1.) infection, 2.) dislocation/instability, 3.) periprosthetic fracture and 4.) loosening, which constitute 87.5% of the reported reasons for revision.

Focusing on these failure modes, hip simulator findings report that ceramic femoral heads dramatically reduce wear debris generation, decreasing the potential for osteolytic response leading to loosening. Further, ceramic materials enable the utilization of larger head sizes, avoiding the potential for dislocation. The overall mid- to long-term survival rate reported in the peer-reviewed, clinical literature for these bearings has exceeded 95% with virtually no osteolysis.

Also, could bearing surface choice influence periprosthetic joint infection (PJI)? A study on a total of more than 10,500 primary THA procedures reported a confirmed PJI incidence of 2.4% for cobalt-chrome and 1.6% for ceramic femoral heads, suggesting that the employ of a ceramic bearing surface may also play a role in decreasing the potential for infection.

Review of the clinical data available for ceramic bearings justifies that it is better to “pay me now than to pay orders of magnitude later”, if in fact a revision THA can be avoided, significantly reducing the overall financial burden to the healthcare system.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 14 - 14
7 Jun 2023
Smeeton M Wilcox R Isaac G Anderson J Board T Van Citters DW Williams S
Full Access

Dual Mobility (DM) Total Hip Replacements (THRs) were introduced to reduce dislocation risk, which is the most common cause of early revision. The in-vivo mechanics of these implants is not well understood, despite their increased use in both elective and trauma settings. Therefore, the aim of this study was to comprehensively assess retrieved DM polyethylene liners for signs of damage using visual inspection and semi-quantitative geometric assessment techniques.

Retrieved DM liners (n=20) were visually inspected for the presence of seven established modes of polyethylene damage. If embedded debris was identified on the external surface, its material composition was characterised using energy-dispersive x-ray analysis (EDX). Additionally, each liner was geometrically assessed for signs of wear/deformation using a validated methodology.

Visual inspection of the liners revealed that scratching and pitting were the most common damage modes on either surface. Burnishing was observed on 50% and 15% of the internal and external surfaces, respectively. In addition, embedded debris was identified on 25% of the internal and 65% of the external surfaces. EDX analysis of the debris identified several materials including iron, titanium, cobalt-chrome, and tantalum. Geometric analysis demonstrated highly variable damage patterns across the liners.

The results of this study provide insight into the in-vivo mechanics of DM bearings. For example, the results suggest that the internal bearing (i.e., between the head and liner) acts as the primary articulation site for DM-THRs as evidenced by a higher incidence of burnishing and larger, more concentrated regions of penetration across the liners’ internal surfaces. Furthermore, circumferential, and crescent-shaped damage patterns were identified on the articulating surfaces of the liners thus providing evidence that these components can rotate within the acetabular shell with varying degrees of mobility. The mechanics of DM bearings are complex and may be influenced by several factors (e.g., soft tissue fibrosis, patient activities) and thus further investigation is warranted.

Finally, the results of this study suggest that DM liners may be susceptible to ex-vivo surface damage and thus caution is advised when handling and/or assessing these types of components.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 48 - 48
7 Jun 2023
Param A Panzures A Van Vliet R Akhtar MA
Full Access

Osteoarthritis (OA) of the hip is the most common indication for total hip replacement (THR). Obesity is a risk factor for the development of OA and has recently resulted in patients requiring THRs at much younger ages to relieve pain at the joint capsule and restore mobility. However, the impact of obesity on THR mortality is not well understood.

An updated systematic review was performed to identify whether an obese BMI should influence patient selection for surgery. Specifically, the impact of obesity on short-term mortality, long-term mortality, and peri- and post-operative complications was assessed with a particular focus on BMI classes.

A comprehensive literature search of Ovid Medline and EMBASE in November 2022 identified relevant papers in accordance with PRISMA methodology. After removing duplicates, 2988 articles underwent strict inclusion and exclusion criteria, resulting in 12 papers for analysis.

There was no statistically significant difference in mortality risk between obese and non-obese populations. Obesity was associated with a lower risk of short-term mortality than in the normal weight control group, however there was an increased mortality risk in obese patients long-term likely due to comorbidities. Obese patients were significantly younger than normal BMI and underweight patients. However, the paper found increased mortality risk in underweight and morbidly obese patients.

Obese patients did not have an increased risk of mortality when compared to non-obese patients following THR. Obesity may have a protective effect on mortality up to a BMI of 40kg/m2, although this may be influenced by the obesity paradox which states only the healthiest obese individuals are selected for surgery, which could attribute to a lower mortality risk. The greatest risk of mortality and complication was associated with underweight patients. As a result, a BMI greater than 30kg/m2 may not necessitate a hip replacement contraindication. It is important surgeons apply careful consideration and comprehensive risk assessment on patients who require a THR, especially at the BMI extremes.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 56 - 56
23 Jun 2023
Sugano N Maeda Y Fuji H Tamura K Nakamura N Takashima K Uemura K Hamada H
Full Access

The purposes of this study were to report the accuracy of stem anteversion for Exeter cemented stems with the Mako hip enhanced mode and to compare it to Accolade cementless stems.

We reviewed the data of 25 hips in 20 patients who underwent THA through the posterior approach with Exeter stems and 25 hips in 19 patients with Accolade stems were matched for age, gender, height, weight, disease, and approaches. There was no difference in the target stem anteversion (20°–30°) between the groups. Two weeks after surgery, CT images were taken to measure stem anteversion.

The difference in stem anteversion between the plan and the postoperative CT measurements was 1.2° ± 3.8° (SD) on average with cemented stems and 4.2° ± 4.2° with cementless stems, respectively (P <0.05). The difference in stem anteversion between the intraoperative measurements and the postoperative CT measurements was 0.75° ± 1.8° with Exeter stems and 2.2° ± 2.3° with Accolade stems, respectively (P <0.05).

This study demonstrated a high precision of anteversion for Exeter cemented stems with the Mako enhanced mode and its clinical accuracy was better with the cemented stems than that with the cementless stems. Although intraoperative stem anteversion measurements with the Mako system were more accurate with the cemented stems than that with the cementless stem, the difference was about 1° and the accuracy of intra-operative anteversion measurements was quite high even with the cementless stems. The smaller difference in stem anteversion between the plan and postoperative measurements with the cemented stems suggested that stem anteversion control was easier with cemented stems under the Mako enhanced mode than that with cementless stems.

Intraoperative stem anteversion measurement with Mako total hip enhanced mode was accurate and it was useful in controlling cemented stem anteversion to the target angle.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 55 - 55
23 Jun 2023
Alqazzaz A Bush A Zhuang T Nelson CL
Full Access

Surgical management of acetabular fractures in older patients remains controversial. The purpose of this study is to compare outcomes of primary THA with outcomes after THA for acute acetabular fractures (aTHA) as well as outcomes following delayed THA (dTHA) following prior acetabular fracture.

We analyzed data from a large, national administrative claims database containing diagnostic, procedural, and demographic records from over 157 million patients. We identified all patients undergoing primary total hip arthroplasty THA continuously enrolled in the database at least 2 years prior and after the index procedure. Patients with an initial diagnostic code for acetabular fracture occurring the same day as the THA were classified as acute acetabular fractures. Patients with an initial acetabular fracture diagnostic code occurring at least 6 months before THA were classified as chronic acetabular fractures. The comparator group was patients undergoing THA with no history of acetabular fracture. There were 426,734 patients undergoing primary THA, 235 patients undergoing aTHA and 1,255 patients undergoing dTHA.

Patients with an aTHA had higher complication rates, including revisions (9.8% vs 5.6%,), dislocations (8.9% vs 6.4%), and periprosthetic fracture (5.1% vs 2.3%) compared to dTHA. After adjusting for age, sex, region, and comorbidities, receiving an aTHA increased the odds of revision (OR = 3.65 [95% CI: 2.30–5.49]), dislocation (OR = 4.09 [95% CI: 2.53–6.27]), and periprosthetic fracture (OR = 4.29 [95% CI: 2.26–7.36]) compared to primary THA. Receiving a dTHA significantly increased the odds of revision (adjusted OR = 1.80 [95% CI: 1.40–2.27]), dislocation (adjusted OR = 2.50 [95% CI: 1.97–3.13]), and periprosthetic fracture (adjusted OR = 1.99 [95% CI: 1.34–2.83]) compared to primary THA.

Patients undergoing aTHA in the treatment of an acetabular fracture have significantly increased rates of revision, periprosthetic fracture, and dislocation compared to dTHA and primary THA.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 18 - 18
23 Jun 2023
Morlock M Melsheimer O
Full Access

The early revision rate in elective Total Hip Arthroplasty (THA) three years after surgery in elderly patients over 80 years is significantly lower for cemented stems in the German Arthroplasty Register (EPRD): cemented 3,1% (3.0 – 3.2) vs. uncemented 4.2% (4.1 – 4.3; p < 0.001). However, the mortality rate in elderly patients is elevated for cemented fixation. This study presents a detailed analysis of the influence of stem type and fixation on revision and mortality rate in this patient cohort.

Elective primary THA cases for primary Coxarthrosis using uncemented cups from the EPRD data base were analysed (n0= 37,183). Four stem type groups were compared: cementless, cementless with collar, cementless short, and cemented. Stems with at least 300 cases at risk three years after surgery were analysed individually. The reference stem was determined as the stem with the lowest revision rate and at least 1000 cases under surveillance 3 years after surgery (n3 = 28,637).

The revision rate for cemented stems (2.5% [2.2–1.81] was lower than for uncemented (4.5% [4.2–4.9]; p<0.001) and uncemented short stems (4.2% [3.1–5.7]; p=0.002). The revision rate of uncemented collared stems (2.3% [1.5–3.6]) was similar to cemented stems (p=0.89) and lower than for uncemented stems (p=0.02). One year mortality showed no sig. differences between the groups (p>0.17): cemented 3.2% [2.9–3.6], uncemented 3.4% [3.1–3.7], uncemented short 3.5% [2.5–4.9], uncemented collar 2.0% [1.2–3.2].

“Cementless” and “cementless short” stems should not be used in patients over 80 years due to the higher revision risk. If cementing should be avoided, “cementless collared” stems seem to be a good alternative combined with a tendency for a lower one year mortality rate.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 25 - 25
23 Jun 2023
Ricard M Pacheco L Koorosh K Poitras S Carsen S Grammatopoulos G Wilkin G Beaulé PE
Full Access

Our understanding of pre-arthritic hip disease has evolved tremendously but challenges remain in categorizing diagnosis, which ultimately impacts choice of treatments and clinical outcomes. This study aims to report patient reported outcome measures (PROMs) comparing four different condition groups within hip preservation surgery by a group of fellowship-trained surgeons.

From 2018 to 2021, 380 patients underwent hip preservation surgery at our center and were classified into five condition groups: dysplasia: 82 (21.6%), femoro-acetabular impingement (FAI): 173 (45.4%), isolated labral tear: 103 (27.1%), failed hip preservation: 20 (5.3%) and history of childhood disease/other: 2 (0.5%). International hip outcomes Tool 12 (IHOT-12), numeric pain score and patient-reported outcomes measurement information system (PROMIS) were collected pre-operatively and at 3 months and 1 year post-operatively, with 94% and 82% follow-up rate respectively.

Arthroscopy (75.5%) was the most common procedure followed by peri-acetabular osteotomy (PAO) (22.4%) and surgical dislocation (2.1%). Re-operation rate were respectively 18.3% (15), 5.8% (10), 4.9% (5), 30% (6) and 0%. There were 36 re-operations in the cohort, 14 (39%) for unintended consequences of initial surgery, 10 (28%) for mal-correction leading to a repeat operation, 8 (22%) progression of arthritis, and 4 (11%) for incorrect initial diagnosis/intervention. Most common re-operations were hardware removal 31% (7 PAO, 3 surgical hip dislocation and 1 femoral de-rotational osteotomy), arthroscopy 31% (11) and arthroplasty 28% (10). All groups had significant improvements in their IHOT-12 as well as PROMIS physical and numerical pain scales, except those with failed hip preservation. Dysplasia group showed a slower recovery.

Overall, this study demonstrated a clear relation between the condition groups, their respective intervention and the significant improvements in PROMs with isolated labral pathology being a valid diagnosis. Establishing tertiary referral centers for hip preservation and longer follow-up is needed to monitor the overall survivorship of these various procedures.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 16 - 16
2 May 2024
McCann C Brunt A Walmsley P Akhtar A
Full Access

There is an increasing demand worldwide for total hip arthroplasty in patients over 80 years old. This study is the largest of its kind reporting long term outcomes and clinical survivorship of patients over 80 years old undergoing THR.

13171 patients 80 years or older who underwent THR between 2000 and 2019 were included. Demographic and operative data was collected including age, sex, laterality, date of surgery and operative technique. Presence and date of complications were collected. Data was also collected for the same time period on 80910 patients aged 51–79 years undergoing THR for comparison.

4103 (31.2%) male and 9068 female (68.8%) patients were included in the 80year old cohort. Median age was 83 (IQR 81–83, range 80–98). 32682 (40.4%) male and 48227 (59.6%) females were included in the 50–79year old cohort. Median age was 68 (IQR 62–73, range 50–79).

The 80 cohort was more likely to sustain post operative complications in the 6 months following surgery including DVT (81/13171 vs 364/80910, P<0.05), myocardial infarction (177/13171 vs 341/80910, P<0.05), acute renal failure (371/12800 vs 812/80910 P<0.05).

The 50–79year old cohort was over twice as likely to undergo revision surgery than the 80 year old cohort (HR 2.55, 95% CI 2.216–2.932, p<0.001). Of those requiring revision surgery, the elderly cohort were more likely to undergo earlier revision surgery (378days, 95%CI 236–519d vs 1586days, 95%CI 1471–1700d, p<0.001). In those undergoing revision surgery, a higher proportion were done for infection in the 80 year old cohort (39/219 (17.8%) vs 215/2809 (7.7%), p<0.05.

This study demonstrates good outcomes in terms of medical complications and a low overall risk of requiring revision surgery in patients 80years old undergoing THR. Patients over the age of 80 should be counselled on the relatively increased risk of medical complications post operatively.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 29 - 29
2 May 2024
Gibbs V Champaneria R Sandercock J Welton N Geneen L Brunskill S Doree C Kimber C Palmer A Estcourt L
Full Access

Preoperative anaemia and intraoperative blood loss result in ∼90% of individuals being anaemic following hip and knee arthroplasty. Reducing blood loss offers the opportunity to improve outcomes and reduce the risk of transfusion and costs. This review's aim was to determine the effectiveness of drugs for preventing blood loss, and identify optimal dose, route, and timing of administration.

Cochrane network meta-analysis of randomised controlled trials was conducted. Inclusion criteria: adults undergoing primary or revision elective hip or knee arthroplasty. Drugs studied: tranexamic acid (TXA), aprotinin, epsilon-aminocaproic acid, desmopressin, factor VIIa and XIII, fibrinogen, fibrin sealants, and non-fibrin sealants. Primary outcomes: need for allogenic blood transfusion, all• cause mortality (within 30 days). Secondary outcomes: mean number of transfusion episodes, re-operation, length of hospital stay and adverse events (DVT, PE, CVA, MI).

102 studies with 8418 participants. Trials included more women (63%). 47 studies (4398 participants) were included within the blood transfusion NMA. TXA given intra-articularly and orally at a total dose of greater than 3g pre-incision, intraoperatively and postoperatively ranked the highest, with anticipated absolute effect of 147 fewer transfusions per 1000 (53% chance ranking 1st) (relative risk(RR) 0.02, 95% credible interval(CrI) 0–0.31); moderate-certainty). Aprotinin (RR 0.59, 95%:CrI 0.36–0.86; low certainty evidence), fibrin (RR 0.86, CrI 0.25–2.93; very-low certainty) and EACA (RR 0.60, 95%:CrI 0.29–1.27; very-low certainty) were not shown to be as effective as TXA.

TXA was the most effective drug for preventing bleeding in lower limb arthroplasty. Aprotinin and EACA were not as effective. Currently, the optimal dose, route and timing of administration of TXA is unclear. However, TXA given at higher doses and via mixed routes ranked higher in the treatment hierarchy. Oral TXA may be as effective as intavenous. There was no evidence of harm associated with higher doses of TXA.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 30 - 30
2 May 2024
Dhesi E Salih S Tomlinson R Salih S
Full Access

Polymethylmethacrylate (PMMA) bone cement is strong in compression, however it tends to fail under torsion. Sufficient pressurisation and subsequent interdigitation between cement and bone are critical for the mechanical interlock of cemented orthopaedic implants, and an irregular surface on the acetabular cup is necessary for reasonable fixation at the cup-cement interface. There is limited literature investigating discrepancies in the failure mechanisms of cemented all-polyethylene acetabular cups with and without cement spacers, under torsional loading.

In vitro experimental comparison of three groups of polyethylene acetabular prosthesis (PAP) cemented into prepared sawbone hemipelvises:

* PAP without PMMA spacers maintaining an equal cement mantle circumferentially. (Group 1 n=3)

* PAP without PMMA spacers cemented deliberately ‘bottoming-out’ the implant within the acetabulum. (Group 2 n=3)

* PAP with PMMA spacers. (Group 3 n=3)

The constructs were tested to torstional failure on a custom designed setup, and statistical analysis done by a one-way ANOVA and Tukey-Welsh test.

Group 3 demonstrated superior torsional resistance with a statistically significant torque of 145Nm (SD±12Nm) at failure, compared to group 2 (109Nm, SD±7Nm) and group 1 (99Nm, SD±8Nm). Group 3 experienced failure predominantly at the bone-cement interface, in contrast, Groups 1 and 2 exhibited failure predominantly at the cup-cement interface. There was no significant difference between Group 1 and 2. Qualitative analysis of the failure mode indicates the efficient redistribution of stress throughout the cement mantle, consistent with the greater uniformity of cement.

PMMA spacers increase the resistance to torsional failure at the implant-cement interface. Acetabular components without spacers (Groups 1 and 2) failed at the implant-cement interface before the cement-bone interface, at a statistically significantly lower level of torque to failure. Although the PMMA spacers may reduce cement interdigitation at the cement-bone interface the torsional forces required to fail are likely supraphysiological.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 52 - 52
2 May 2024
Bayram JM Wickramasinghe N Scott CE Clement ND
Full Access

The aims were to assess whether preoperative joint-specific function (JSF) and health-related quality of life (HRQoL) were associated with level of clinical frailty in patients waiting for a primary total hip arthroplasty (THA) or knee arthroplasty (KA).

Patients waiting for a THA (n=100) or KA (n=100) for more than six months were prospectively recruited from the study centre. Overall, 162 patients responded to the questionnaire (81 THA; 81 KA). Patient demographics, Oxford score, EuroQol five dimension (EQ-5D) score, EuroQol visual analogue score (EQ-VAS), Rockwood Clinical Frailty Score (CFS), and time spent on the waiting list were collected.

There was a significant correlation between CFS and the Oxford score (THA r=ˆ’0.838; p<0.001, KA r=ˆ’0.867; p<0.001), EQ-5D index (THA r=ˆ’0.663, p<0.001; KA r=ˆ’0.681; p< 0.001), and EQ-VAS (THA r=ˆ’0.414; p<0.001, KA r=ˆ’0.386; p<0.001). Confounding variables (demographics and waiting time) where adjusted for using multiple regression analysis. For each 8.5 (THA, 95% CI 7.1 to 10.0; p<0.001) and 9.9 (KA, 95% CI 8.4 to 11.4; p<0.001) point change in the Oxford score, there was an associated change in level of the CFS. For each 0.16 (THA, 95% CI 0.10 to 0.22; p<0.001) and 0.20 (KA, 95% CI 0.12 to 0.27; p<0.001) utility change in EQ-5D, there was an associated change in level of the CFS. EQ-VAS (THA, B=ˆ’11.5; p<0.001, KA B=ˆ’7.9; p=0.005) was also associated with CFS.

JSF and HRQoL in patients awaiting THA or KA for more than six months, were independently associated with level of clinical frailty. With further prospective studies, clinical frailty may prove to be a useful metric to assist in the prioritization of arthroplasty waiting lists.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 47 - 47
2 May 2024
Kolhe S Khanduja V Malviya A
Full Access

Hip arthroscopy (HA) is an effective treatment for various hip conditions but has a steep learning curve and its effect on long-term joint preservation is unclear. This study uses population-level data to assess (1) the 90-day complication rate, and (2) the frequency and timing of revision HA, total hip replacement (THR), and pelvic osteotomy (PO) following primary HA.

We performed a retrospective analysis of the National Hospital Episode Statistics database, examining all patients who underwent primary HA in NHS hospitals in England from 2010 to 2023 using relevant OPCS-4 codes. We evaluated patient demographics, 90-day complications, and reoperation rates for revision HA, THR, and PO. Descriptive statistical analyses were performed to calculate frequencies and average time to reoperations.

We included 22,401 HA procedures in the study. The mean LOS was 0.82±2.04 days. The 90-day readmission rate was 0.17% at a mean of 54.4±8.1 days. The most common reasons for readmission were reoperation (0.071%), followed by infection (0.031%), pulmonary embolism (0.027%), pain (0.022%), bleeding (0.018%), and deep vein thrombosis (0.004%). One patient died within 90 days.

Overall, 4942 patients (22.1%) required further surgery at a mean of 2.71±2.27 years. The rates of revision HA, conversion to THR, and PO were 6.94%, 14.6%, and 0.50% at a mean of 2.39±1.79, 2.87±2.46, and 2.26±1.80 years respectively. Female patients had higher rates of reoperation than males for conversion to THR (9.99% vs 4.63%), revision HA (4.92% vs 2.02%), and subsequent PO (0.43% vs. 0.06%) (p<0.001).

This study demonstrates a low short-term complication rate after primary HA, supporting existing literature. However, a large proportion of patients required further surgery, especially females. These findings highlight the need for careful patient selection and counselling before HA to optimise outcomes, as well as further research on factors influencing longer-term outcomes and cost-effectiveness.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 62 - 62
2 May 2024
Afzal S Sephton B Wilkinson H Hodhody G Ammori M Kennedy J Hoggett L Board T
Full Access

Total Hip Arthroplasty (THA) and Hip Hemiarthroplasties (HA) are successful, cost-effective procedures that improve quality of life. Dislocation is a well recognised complication with a significant health and economic burden. We aim to establish the current management practices across the United Kingdom (UK) for Prosthetic Hip Dislocations (PHD). Our definition of a PHD includes; THA, HA and revision THA.

This national study builds on our regional pilot study and records one of the largest datasets of Prosthetic Hip Dislocation management within the UK.

A trainee-led collaborative; the North West Orthopaedic Research Collaborative (NWORC). Conducted a retrospective audit, registered as Quality Improvement (QI) projects, collected data from 38 hospital trusts across the UK.

Data was collected on patient-related factors, inpatient management, and outpatient follow up of each PHD episode between January and July 2019. Primary outcome measured definitive management, in the form of revision surgery or the consideration for this through a referral pathway.

A total of 673 (THA 504, Revision THA 141, HA 28) patients were included with a total of 740 dislocation episodes. Mean age was 75.6 years with female to male ratio 2:1. The majority of PHDs were a result of a low energy mechanism (98.7%) and presented over 6 months post index procedure (80.5%). Over half (53.8%) attended with a first or second time dislocation. Only 29.9% patients received onward revision referral; whereas 70.1% followed diverse management patterns, including local non-arthroplasty and primary arthroplasty surgeon follow-ups. Revision THAs had higher rates of referral for revision (p<0.001) compared to primary THA and HA dislocations.

A high number of PHDs present across the UK, with under a third receiving definitive management plans. This variation increases the economical burden to the National Health Service, highlighting the need for national guidance to manage these complex patients.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 1 - 1
2 May 2024
Mayne A Saad A Botchu R Politis A Wall P McBryde C
Full Access

Radiological investigations are essential in the work-up of patients presenting with non-arthritic hip pain, to allow close review of the complex anatomy around the hip and proximal femur. The aim of this study is to quantify the radiation exposure associated with common radiological investigations performed in assessing young adult patients presenting with non-arthritic hip pain.

A retrospective review of our UK tertiary hip preservation centre institutional imaging database was performed. Data was obtained for antero-posterior, cross-table lateral and frog-lateral radiographs, along with data for the low dose CT hip protocol and the Mako CT Hip protocol. The radiation dose of each imaging technique was measured in terms of dose-area product (DAP) with units of mGycm2, and the effective doses (ED, mSv) calculated.

The mean effective radiation dose for hip radiographs was in the range 0.03 to 0.83mSv (mean DLP 126.7–156.2 mGycm2). The mean effective dose associated with the low-dose CT hip protocol was 3.04mSv (416.8 mGycm2) and for the Stryker Mako CT Hip protocol was 8.4mSv (1061 mGycm2). The radiation dose associated with use of CT imaging was significantly greater than plain radiographs (p<0.005)

Investigation of non-arthritic hip pain can lead to significant ionising radiation exposure for patients. In our institution, the routine protocol is to obtain an anteroposterior radiograph and then a specific hip sequence 3 Tesla MRI including anteversion views. This provides the necessary information in the majority of cases, with CT scanning reserved for more complex cases where we feel there is a specific indication. We would encourage the hip preservation community to carefully consider and review the use of ionising radiation investigations.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 43 - 43
2 May 2024
Martin R Fishley W Kingman A Carluke I Kramer D Partington P Reed M Petheram T
Full Access

Periprosthetic joint infection is a serious complication of primary total hip replacement (THR) with significant associated morbidity. In acute infection, Debridement, Antibiotics and Implant Retention (DAIR) may be considered. Current national guidelines recommend a DAIR should be performed by “an experienced arthroplasty surgeon┕ but do not specify the need for this to be a revision arthroplasty surgeon. We investigated outcomes in our NHS Trust of DAIR procedures performed by revision and non-revision arthroplasty surgeons.

Infection registry data and patient records were analysed for all DAIR procedures of infected primary THRs between 2017 and 2021. Data collected included details of the primary surgery, the presentation with infection, the DAIR procedure and any subsequent complications including return to theatre at any time point. Routinely collected pre- and post-operative patient reported outcome measures (PROMs) were reviewed.

54 periprosthetic joint infections of primary THRs received a DAIR procedure. 41 DAIRs were performed by a revision surgeon and 13 by non-revision surgeons. There was no significant difference in time from primary THR to presentation with infection, time from presentation to DAIR or pre-operative C-reactive protein between the two groups.

In 21 (38.9%) patients the DAIR procedure was classed as a treatment failure; 17 patients (31.5%) returned to theatre for further revision surgery, one (2.4%) died related to infection and three (5.6%) had persistent infection but did not receive further surgery. Treatment failure was significantly higher in the non-revision surgeon group (9/13 (69.2%)) than in the revision surgeon group (12/41 (29.3%)) (p = 0.02). Overall, improvement in PROMs after DAIR was seen at both six and 12 months.

The overall success rate of DAIR was 61.1% and there was a sustained improvement in PROMs after surgery. However, there was a significant difference in failure rates between revision surgeons and non-revision surgeons.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 2 - 2
2 May 2024
Gunn C Thakker V Jones HW Barrow J
Full Access

Ceramic bearing fracture is a rare complication following implantation using modern day ceramic bearing materials. Revision bearing options in such cases is debated, with the choice between ceramic-on-ceramic and ceramic-on-polyethylene bearings. Revision to a hard on soft bearing raises concerns about potential catastrophic wear secondary to a third-body reaction caused by the fractured ceramic particles.

Data was collected retrospectively from the NJR, electronic patient records, revision database and picture archiving and communication system. Templating software was used to determine linear wear between first post-operative radiograph and the latest available follow up. Univariate analysis was used to examine patient demographics and the wear rates for revision of ceramic bearing fractures to ceramic on polyethylene components. The intra and inter-rater reliability of wear measurements was calculated.

There were twelve patients identified as meeting the inclusion criteria. The average age at revision was 62 years (54–72). There were 6 liner and 6 head fractures revised to delta ceramic heads and cross-linked polyethylene acetabular components. The most frequently used head size was 32mm. At mean follow up of 3.8 years (0.5 6.1 years), median 4.4 years, linear wear rate was calculated at 0.08± 0.06 mm/year. Both intra-rater and inter-rater reliability was excellent with ICC scores of 0.99 at all timepoints.

Revision to ceramic on polyethylene (CoP) bearings following ceramic fracture does not cause early catastrophic wear at early follow up. It appears safe to use this hard on soft bearing combination, given that wear rates are comparable to what is expected in a primary hip replacement setting. Longer follow up is required to establish if this trend persists.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 21 - 21
2 May 2024
Palit A Kiraci E Seemala V Gupta V Williams M King R
Full Access

Ideally the hip arthroplasty should not be subject to bony or prosthetic impingement, in order to minimise complications and optimise outcomes. Modern 3d planning permits pre-operative simulation of the movements of the planned hip arthroplasty to check for such impingement. For this to be meaningful, however, it is necessary to know the range of movement (ROM) that should be simulated. Arbitrary “normal” values for hip ROM are of limited value in such simulations: it is well known that hip ROM is individualised for each patient. We have therefore developed a method to determine this individualised ROM using CT scans.

CT scans were performed on 14 cadaveric hips, and the images were segmented to create 3d virtual models. Using Matlab software, each virtual hip was moved in all potential directions to the point of bony impingement, thus defining an individualised impingement-free 3d ROM envelope. This was then compared with the actual ROM as directly measured from each cadaver using a high-resolution motion capture system.

For each hip, the ROM envelope free of bony impingement could be described from the CT and represented as a 3d shape. As expected, the directly measured ROM from the cadaver study for each hip was smaller than the CT-based prediction, owing to the presence of constraining soft tissues. However, for movements associated with hip dislocation (such as flexion with internal rotation), the cadaver measurements matched the CT prediction, to within 10°.

It is possible to determine an individual's range of clinically important hip movements from a CT scan. This method could therefore be used to create truly personalised movement simulation as part of pre-operative 3d surgical planning.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 45 - 45
2 May 2024
Mahmoud MA Sharkawy E Kamel M Metwaly S Said H Noaman S
Full Access

The postoperative pain after hip arthroscopy remains a major challenge in the immediate postoperative period. Adequate postoperative analgesia has been associated with increased patient satisfaction and decreased consumption of opioids. We evaluated the efficacy of pericapsular nerve group block (PENG) versus fascia iliaca block (FIB) in reducing post-operative pain and analgesic consumption within the first 24 hours following arthroscopic management of femoroacetabular impingement (FAI).

Thirty-nine patients (17 females and 25 males, ages 18–42 years, mean ± SD (27.9 ± 6.2), and mean BMI of 25.13±5.08 kg/m2 were scheduled for primary arthroscopic management of FAI. Included patients were randomized into two groups according to the block used in each. Group (A) 19 patients were included and had FIB and group (B) 20 patients were included and received PENG block. The efficacy of both techniques was clinically and statistically valuated using VAS score and quadriceps muscle power.

There was a statically significance difference in the mean at rest between the two groups at all measured time points following surgery (6, 12, 18 and 24 h). Also, in dynamic pain scores (with hip flexion) scores were statistically significant at 24 hours post-operative (P = .001). Total opioid consumption in the first 24 hours postoperative was lower in the PENG group with significant difference of mean 16.5 ±9.9 mg for PENG group versus 27.5±9.6 mg for FIB group (P < .005). Five patients (26.31%) in FIB group had weaker quadriceps muscle power while none in PENG group patients had quadriceps weakness.

PENG block might be considered as an ideal regional anesthesia modality for hip arthroscopy. As an alternative to more conventional regional nerve blocks such as a fascia iliaca block. PENG block is easily performed in the preoperative setting, and appears to spare motor function while providing a prolonged sensory pain relief.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 261 - 268
1 Mar 2023
Ruhr M Huber G Niki Y Lohner L Ondruschka B Morlock MM

Aims

The aim of the study was to investigate whether the primary stability of press-fit acetabular components can be improved by altering the impaction procedure.

Methods

Three impaction procedures were used to implant acetabular components into human cadaveric acetabula using a powered impaction device. An impaction frequency of 1 Hz until complete component seating served as reference. Overimpaction was simulated by adding ten strokes after complete component seating. High-frequency implantation was performed at 6 Hz. The lever-out moment of the acetabular components was used as measure for primary stability. Permanent bone deformation was assessed by comparison of double micro-CT (µCT) measurements before and after impaction. Acetabular component deformation and impaction forces were recorded, and the extent of bone-implant contact was determined from 3D laser scans.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 781 - 785
1 Jul 2022
Ferraro SL Williams DN Millis MB

Aims

The aim of this study was to understand the experience of mature patients who undergo a periacetabular osteotomy (PAO), a major hip-preserving surgical procedure that treats symptomatic hip dysplasia by realigning the acetabulum. Our aim was to improve our understanding of how the operation affected the lives of patients and their families, with a long-term goal of improving their experience.

Methods

We used a phenomenological approach with in-depth, semi-structured interviews to investigate the experience of seven female patients, aged between 25 and 40 years, who underwent a PAO. A modified homogeneity sampling approach coupled with criterion sampling was used. Inclusion criteria involved having at least one child at home and being in a committed relationship with a spouse or partner.