Advertisement for orthosearch.org.uk
Results 1 - 20 of 21
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 957 - 963
1 Sep 2024
Baek CH Kim JG Kim BT

Aims. Favourable short-term outcomes have been reported following latissimus dorsi tendon transfer for patients with an irreparable subscapularis (SSC) tendon tear. The aim of this study was to investigate the long-term outcomes of this transfer in these patients. Methods. This was a retrospective study involving 30 patients with an irreparable SSC tear and those with a SSC tear combined with a reparable supraspinatus tear, who underwent a latissimus dorsi tendon transfer. Clinical scores and active range of motion (aROM), SSC-specific physical examination and the rate of return to work were assessed. Radiological assessment included recording the acromiohumeral distance (AHD), the Hamada grade of cuff tear arthropathy and the integrity of the transferred tendon. Statistical analysis compared preoperative, short-term (two years), and final follow-up at a mean of 8.7 years (7 to 10). Results. There were significant improvements in clinical scores, in the range and strength of internal rotation and aROM compared with the preoperative values in the 26 patients (87%) who were available for long-term follow-up. These improvements were maintained between short- and long-term follow-ups. Although there was a decreased mean AHD of 7.3 mm (SD 1.5) and an increased mean Hamada grade of 1.7 (SD 0.5) at final follow-up, the rate of progression of cuff tear arthropathy remained low-grade. Comparison between the isolated SSC and combined SSC and reparable supraspinatus tear groups showed no significant differences. At final follow-up, one patient (3.8%) had undergone revision surgery to a reverse shoulder arthroplasty (RSA). No neurological complications were associated with the procedure. Conclusion. Latissimus dorsi transfer for an irreparable SSC tendon tear resulted in a significant clinical improvement, particularly in pain, range and strength of internal rotation and aROM, which were maintained over a mean of 8.7 years following surgery. Given that this was a long-term outcome study, there was a low-grade progression in the rate of cuff tear arthropathy. Thus, the long-term clinical efficacy of latissimus dorsi tendon transfer in patients with irreparable SSC was confirmed as a joint-preserving procedure for these patients, suggesting it as an effective alternative to RSA in young, active patients without degenerative changes of the glenohumeral joint. Cite this article: Bone Joint J 2024;106-B(9):957–963


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 970 - 977
1 Sep 2024
De Rus Aznar I Ávila Lafuente JL Hachem A Díaz Heredia J Kany J Elhassan B Ruiz Ibán MÁ

Rotator cuff pathology is the main cause of shoulder pain and dysfunction in older adults. When a rotator cuff tear involves the subscapularis tendon, the symptoms are usually more severe and the prognosis after surgery must be guarded. Isolated subscapularis tears represent 18% of all rotator cuff tears and arthroscopic repair is a good alternative primary treatment. However, when the tendon is deemed irreparable, tendon transfers are the only option for younger or high-functioning patients. The aim of this review is to describe the indications, biomechanical principles, and outcomes which have been reported for tendon transfers, which are available for the treatment of irreparable subscapularis tears. The best tendon to be transferred remains controversial. Pectoralis major transfer was described more than 30 years ago to treat patients with failed surgery for instability of the shoulder. It has subsequently been used extensively to manage irreparable subscapularis tendon tears in many clinical settings. Although pectoralis major reproduces the position and orientation of the subscapularis in the coronal plane, its position in the axial plane – anterior to the rib cage – is clearly different and does not allow it to function as an ideal transfer. Consistent relief of pain and moderate recovery of strength and function have been reported following the use of this transfer. In an attempt to improve on these results, latissimus dorsi tendon transfer was proposed as an alternative and the technique has evolved from an open to an arthroscopic procedure. Satisfactory relief of pain and improvements in functional shoulder scores have recently been reported following its use. Both pectoralis minor and upper trapezius transfers have also been used in these patients, but the outcomes that have been reported do not support their widespread use. Cite this article: Bone Joint J 2024;106-B(9):970–977


Bone & Joint 360
Vol. 12, Issue 6 | Pages 31 - 34
1 Dec 2023

The December 2023 Shoulder & Elbow Roundup360 looks at: Clavicle fractures: is the evidence changing practice?; Humeral shaft fractures, and another meta-analysis…let’s wait for the trials now!; Hemiarthroplasty or total elbow arthroplasty for distal humeral fractures…what does the registry say?; What to do with a first-time shoulder dislocation?; Deprivation indices and minimal clinically important difference for patient-reported outcomes after arthroscopic rotator cuff repair; Prospective randomized clinical trial of arthroscopic repair versus debridement for partial subscapularis tears; Long-term follow-up following closed reduction and early movement for simple dislocation of the elbow; Sternoclavicular joint reconstruction for traumatic acute and chronic anterior and posterior instability.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 603 - 609
1 May 2019
Aagaard KE Lunsjö K Frobell R

Aims

Failure of healing is a well-known problem after repair of the rotator cuff. This study aimed to investigate if early repair of trauma-related full-thickness rotator cuff tears (FTRCTs) could prevent this failure.

Patients and Methods

In this prospective trial, 62 consecutive patients (14 women (23%), 48 men (77%); median age 61 years (interquartile range (IQR) 54 to 65)) with trauma-related FTRCT underwent arthroscopic single-row repair within six weeks of trauma. Tendon integrity was assessed one year after surgery using the Sugaya score on MR images. Patients were followed up with Western Ontario Rotator Cuff (WORC) index, EuroQol visual analogue scale (EQ VAS), and the Constant–Murley score (CS) two years after repair.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1090 - 1095
1 Aug 2015
Urita A Funakoshi T Suenaga N Oizumi N Iwasaki N

This pilot study reports the clinical outcomes of a combination of partial subscapularis tendon transfer and small-head hemiarthroplasty in patients with rotatator cuff arthropathy. A total of 30 patients (30 shoulders; eight men and 22 women) with a mean age of 74 years (55 to 84) were assessed at a mean follow-up of 31 months (24 to 60). The inclusion criteria were painful cuff tear arthropathy with normal deltoid function and a non-degenerative subscapularis muscle and tendon and a preserved teres minor. Outcome was assessed using the University of California Los Angeles score, the Japanese Orthopaedic Association score, and the Oxford Shoulder Score. Radiographic measurements included the centre of rotation distance and the length of the deltoid. All clinical scores were significantly improved post-operatively. The active flexion and external rotation improved significantly at the most recent follow-up (p < 0.035). Although the mean centre of rotation distance changed significantly (p < 0.001), the mean length of the deltoid did not change significantly from the pre-operative value (p = 0.29). The change in the length of the deltoid with < 100° flexion was significantly less than that with > 100° (p < 0.001). Progressive erosion of the glenoid was seen in four patients. No patient required revision or further surgery. A combination of partial subscapularis tendon transfer and small-head hemiarthroplasty effectively restored function and relieved pain in patients with rotator cuff arthropathy. Cite this article: 2015;97-B:1090–5


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1106 - 1113
1 Aug 2013
Lädermann A Walch G Denard PJ Collin P Sirveaux F Favard L Edwards TB Kherad O Boileau P

The indications for reverse shoulder arthroplasty (RSA) continue to be expanded. Associated impairment of the deltoid muscle has been considered a contraindication to its use, as function of the RSA depends on the deltoid and impairment of the deltoid may increase the risk of dislocation. The aim of this retrospective study was to determine the functional outcome and risk of dislocation following the use of an RSA in patients with impaired deltoid function. Between 1999 and 2010, 49 patients (49 shoulders) with impairment of the deltoid underwent RSA and were reviewed at a mean of 38 months (12 to 142) post-operatively. There were nine post-operative complications (18%), including two dislocations. The mean forward elevation improved from 50° (sd 38; 0° to 150°) pre-operatively to 121° (sd 40; 0° to 170°) at final follow-up (p < 0.001). The mean Constant score improved from 24 (sd 12; 2 to 51) to 58 (sd 17; 16 to 83) (p < 0.001). The mean Single Assessment Numeric Evaluation score was 71 (sd 17; 10 to 95) and the rate of patient satisfaction was 98% (48 of 49) at final follow-up.

These results suggest that pre-operative deltoid impairment, in certain circumstances, is not an absolute contraindication to RSA. This form of treatment can yield reliable improvement in function without excessive risk of post-operative dislocation.

Cite this article: Bone Joint J 2013;95-B:1106–13.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 199 - 205
1 Feb 2013
Robinson PM Wilson J Dalal S Parker RA Norburn P Roy BR

This study reports the clinical and sonographic outcome of arthroscopic rotator cuff repair in patients aged ≥ 70 years and aimed to determine factors associated with re-tear. A total of 69 consecutive repairs were performed in 68 patients with a mean age of 77 years (70 to 86). Constant-Murley scores were collected pre-operatively and at one year post-operatively. The integrity of the repair was assessed using ultrasound. Re-tear was detected in 20 of 62 patients (32%) assessed with ultrasound. Age at operation was significantly associated with re-tear free survival (p = 0.016). The mean pre-operative Constant score was 23 (sd 14), which increased to 58 (sd 20) at one year post-operatively (paired t-test, p < 0.001). Male gender was significantly associated with a higher score at one year (p = 0.019).

We conclude that arthroscopic rotator cuff repair in patients aged ≥ 70 years is a successful procedure. The gender and age of the patient are important factors to consider when planning management.

Cite this article: Bone Joint J 2013;95-B:199–205.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 42 - 42
1 Jan 2011
Singisetti K Bhaskar D Newby M Hinsche A
Full Access

Ultrasonography for rotator cuff disease is a cheap and non-invasive investigation. Our study investigates the tendon specific pathologies leading to misinterpretation of ultrasound findings and their implication for the surgical management. On hundred and five consecutive patients who had an ultrasound scan by a single musculoskeletal radiologist and then underwent shoulder arthroscopy by a single shoulder surgeon for rotator cuff pathologies were included. Surpraspinatus Tendon (SST): There was a sensitivity of 90%. The relatively low positive predictive value (76%) and specificity (42.5%) were influenced by a high number of false positives. This was a mixed group of 23 cases, in which ultrasonography had described either a full-thickness (FTT) or partial-thickness (PTT) tear when arthroscopy did not show any evidence for a cuff tear. Seven of these cases were described as FTT with dimensions less than 1 cm and in ten cases the radiologist described a “possible sub-centimetre tear”. Subscapularis Tendon (SSC): There was a specificity of 100%. The poor negative predictive value (78%) and sensitivity (26%) were caused by a high number of false negatives. Further analysis of the 20 “false negative” patients showed four FTT and sixteen PTT. All partial thickness tears involved the superior fibres of the subscapularis tendon. Our results confirm that USG is a reliable investigation in larger full thickness tears, particularly of the superior rotator cuff (SST). The reliability is significantly reduced in sub-centimetre tears and partial thickness tears, particularly of the subscapularis tendon. Associated tendon pathologies like intra-tendinous calcifications and intra-substance tears make an accurate diagnosis even more difficult and add to the tendency to ‘over-diagnose’ tears of the rotator cuff with use of ultrasonography. The shoulder surgeon should be aware of the potential misinterpretation of ultrasonography findings and be prepared to adjust the surgical procedure accordingly


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 571 - 571
1 Oct 2010
Dietz S Nijs S Rommens P Sternstein W
Full Access

The aim of our biomechanical study was to find out whether the prosthetic design, especially of the metaphyseal part, and the type of tuberosity fixation influences the primary stability in shoulder arthroplasty. Materials and Methods: 16 fresh frozen human cadaveric humeri were dissected until only the rotator cuff remained. A four-part fracture was simulated by osteotomy. In a first step two types of shoulder prosthesis (open stem versus closed stem) were used. The Tornier Aequalis prosthesis (open stem) using suture fixation and the Mathys Affinis fracture prosthesis (closed stem) using cable fixation were implanted according to standard techniques. The specimens were then loaded into a servo-pneumatic testing device in 25° of abduction. In 20 consecutive cycles traction of 40 Newton was alternating exerted on the subscapularis and infraspinatus tendon, while a continuous force of 40 Newton was exerted on the greater tuberosity to simulate the pull of the m. supraspinatus. The motion of the fragments was recorded by 2 high speed cameras. The following parameters were investigated : Failure of osteosynthesis, intertuberosity motion, motion lesser tuberosity-shaft, motion greater tuberosity-shaft, motion metaphysis-shaft. After completing the first series the cable fixation exposed to be more stable. In a second series we compared cable versus suture fixation in the Affinis fracture prosthesis to find out whether the stability was depending on the prosthesis design. Results:. Series 1: The intertuberosity motion was significantly lower in the cable prosthesis. The tuberosity-shaft motion was significantly lower in the cable group for greater and lesser tuberosity. The metaphysis - shaft motion did not significantly differ in both groups. Series 2: The intertuberosity motion was significant lower when the tuberosities were fixed by cable. The tuberosity-shaft motion was significantly lower when cable fixation was used. The metaphysis-shaft motion was not significantly diverse. Conclusion: Highest primary stability of tuberosity fixation in trauma-arthroplasty of the shoulder was measured in cable fixation and closed stem. We proved that the kind of fixation was the most important factor determing the stability. Metaphyseal design was less important


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 208 - 208
1 Mar 2010
Sandher D Bell S Kingston R
Full Access

The benefit of open stabilization for recurrent shoulder instability is well known, however there have been recent reports of postoperative dysfunction of the subscapularis tendon following open shoulder surgery (Habermeyer et al, Scheibel et al). We present our findings in patients who have undergone an open anterior stabilization using a subscapularis split approach. We reviewed 48 patients (49 shoulders), who were treated by the senior author (SB) from 2003–2005. They all underwent an open anterior stabilization of shoulder through a deltopectoral approach, with a subscapularis split technique, without any lateral tendon detachment. The minimum follow-up was 2 years, with average 34 months. Thirty-eight shoulders underwent an isolated anterior stabilization (1 bilateral) and 11 patients had additional procedures (8 bone grafts, 1 SLAP repair, 1 cuff repair, 1 anterior and posterior repair). There were 41 male and 7 female patients, and the mean age was 23.9 years (range 15–47 years). All patients were involved in sports and 45 had presented with recurrent dislocations. Patients were followed up using the Oxford instability score and the Rowe score questionnaires. All had a clinical examination for range of movement, stability, subscapularis muscle function, or signs of dysfunction. All had a MRI to assess the quality of the subscapularis muscle and tendon. Mean postoperative Oxford instability score was 22.5 and the Rowe score was 69.38. Two patients had redislocated following re-injury. There was no evidence clinically of subscapularis dysfunction and the muscle and tendon were normal on all MRI scans. External rotation was reduced by a mean of 15.6 degrees. There was no significant loss of flexion or abduction. 81% of patients returned to their previous level of sport. With a subscapularis split technique for anterior shoulder stabilization there is no significant postoperative dysfunction or damage to the subscapularis muscle, and most patients return to their previous level of sport


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 57 - 57
1 Mar 2010
Millar* N Wei A Molloy T Bonar F Murrell G
Full Access

Excessive apoptosis has been found in torn supraspinatus tendon1 and mechanically loaded tendon cells2. Following oxidative and other forms of stress, one family of proteins that is often unregulated are Heat Shock Proteins (HSPs). The purpose of this study was to determine if HSPs were unregulated in human and rat models of tendinopathy and to determine if this was associated with increased expression of regulators of apoptosis (cFLIP, Caspases 3& 8). A running rat supraspinatus tendinopathy overuse model 3 was used with custom microarrays consisting of 5760 rat oligonucleotides in duplicate. Seventeen torn supraspinatus tendon and matched intact subscapularis tendon samples were collected from patients undergoing arthroscopic shoulder surgery. Control samples of subscapularis tendon were collected from ten patients undergoing arthroscopic stabilisation surgery and evaluated using semiquantative RT-PCR and immunohistochemistry. Rat Microarray: Upregulation of HSP 27 (×3.4) & 70 (×2.5) and cFLIP (×2.2) receptor was noted in degenerative rat supraspinatus tendon subjected to daily treadmill running for 14 days compared to tendons of animals subject to cage activity only. Histological analysis: All torn human supraspinatus tendons exhibited changes consistent with marked tendinopathy. Matched subscapularis tendon showed appearances of moderate-advanced degenerative change. Apoptosis mRNA expression: The expression levels of caspase 3 & 8 and HSPs 27 & 70 were significantly higher in the torn edges of supraspinatus when compared to matched subscapularis tendon and control tendon (p< 0.01). cFLIP showed significantly greater (p< 0.001) expression in matched subscapularis compared to supraspinatus and control tendon. Immunohistochemical analysis: cFLIP, Caspase 3 & 8 and HSP 27 and 70 was confirmed in all samples of torn supraspinatus tendon. Significantly increased immunoactivity of Caspase 3& 8 and HSP 27 & 70 were found in torn supraspinatus (p< 0.001) compared to matched and normal subscapularis. The proteins were localized to tendon cells. The finding of significantly increased levels of Heat Shock Proteins in human and rat models of tendinopathy with the co-expression of other regulators of apoptosis suggests that Heat Shock Proteins play a role in the cascade of stress activated-programmed cell death and degeneration in tendinopathy


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 943 - 948
1 Jul 2009
Bertelli JA

An internal rotation contracture is a common complication of obstetric brachial plexus palsy. We describe the operative treatment of seven children with a recurrent internal rotation contracture of the shoulder following earlier corrective surgery which included subscapularis slide and latissimus dorsi transfer. We performed z-lengthening of the tendon of the subscapularis muscle and transferred the lower trapezius muscle to the infraspinatus tendon. Two years postoperatively the mean gain in active external rotation was 47.1°, which increased to 54.3° at four years. Lengthening of the tendon of subcapularis and lower trapezius transfer to infraspinatus improved the range of active external rotation in patients who had previously had surgery for an internal rotation contracture


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 259 - 260
1 May 2009
Lam F Bhatia D van Rooyen K du Toit D de Beer J
Full Access

Introduction: We have devised a new technique of lesser tuberosity osteotomy with double row fixation of the subscapularis using suture anchors. Aim: To evaluate the biomechanical properties of this novel technique against two established methods of subscapularis repair including tendon to tendon and transosseous repairs. Method: Matched pairs of human cadaveric shoulders were allocated into 3 groups. Group 1 consisted of the double row technique with incision of the subscapularis along the bicipital groove with a lesser tuberosity osteotomy. A double loaded suture anchor was placed along the medial border of the osteotomy site and sutures were passed through subscapularis medial to the bone island in a horizontal mattress manner. A second anchor was inserted along the lateral border of the osteotomy site and the two sutures were tied onto the subscapularis holding sutures. In group 2, the subscapularis was divided 1cm medial to the bicipital groove and repaired with tendon to tendon suturing. In group 3, the subscapularis was repaired to the cut humeral neck through transosseous tunnels. The cyclic elongation, load to failure, displacement and mode of failure were analysed. Results: All specimens in Group 1 and 40% of Group 2 and 3 passed the cyclic loading test. The ultimate tensile strength in Group 1 was found to be 2.8 times that of Group 2 and 2.4 times that of Group 3 (p< 0.05). Simple suturing failed by suture cutting out of soft tissue and tranosseous repair failed by a combination of the suture cutting out through bone and soft tissue. Conclusion: This novel technique is simple to perform and biomechanically stronger than established methods of repair. A stronger fixation may allow early mobilization without the risk of tendon rupture and is much less likely to loosen with gap formation and subsequent fibrous tissue interposition. Additional advantages include bone to bone healing without violation of the subscapularis tendon


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 196 - 200
1 Feb 2009
Moosmayer S Smith H Tariq R Larmo A

We undertook clinical and ultrasonographic examination of the shoulders of 420 asymptomatic volunteers aged between 50 and 79 years. MRI was performed in selected cases. Full-thickness tears of the rotator cuff were detected in 32 subjects (7.6%). The prevalence increased with age as follows: 50 to 59 years, 2.1%; 60 to 69 years, 5.7%; and 70 to 79 years, 15%. The mean size of the tear was less than 3 cm and tear localisation was limited to the supraspinatus tendon in most cases (78%). The strength of flexion was reduced significantly in the group with tears (p = 0.01).

Asymptomatic tears of the rotator cuff should be regarded as part of the normal ageing process in the elderly but may be less common than hitherto believed.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 889 - 892
1 Jul 2008
Al-Shawi A Badge R Bunker T

We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon using a portable ultrasound scanner in a one-stop clinic. There were 78 full thickness tears which we confirmed by surgery or MRI. Three moderate-size tears were assessed as partial-thickness at ultrasound scan (false negative) giving a sensitivity of 96.2%. One partially torn and two intact cuffs were over-diagnosed as small full-thickness tears by ultrasound scan (false positive) giving a specificity of 95.4%. This gave a positive predictive value of 96.2% and a negative predictive value of 95.4%. Estimation of tear size was more accurate for large and massive tears at 96.5% than for moderate (88.8%) and small tears (91.6%). These results are equivalent to those obtained by several studies undertaken by experienced radiologists.

We conclude that ultrasound imaging of the shoulder performed by a sufficiently-trained orthopaedic surgeon is a reliable time-saving practice to identify rotator-cuff integrity.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 345 - 345
1 May 2006
Parnes N Maman E Mozes G
Full Access

Introduction: Latarjete operation for anterior shoulder instability, first described by Latarjete in 1954 consists of transfer of the coracoid process through the sub-scapularis tendon to the neck of the scapula. Many modifications were described in the English literature as described by Mc Murray in 1958, by Bonin in 1969 or May in 1970. In 1985, Braly and Tullos emphasized that the Bankart lesion, when present, should be corrected. Rockwood transplants the entire coracoid process onto the neck by “laying it flat” onto the neck of the scapula using two screws instead of one, which gives a larger base for the coracoid transplant. The disadvantages of this procedure, as described in the English literature, are relative shortening of the sub-scapularis tendon, thereby decreasing internal rotation power, limited external rotation and the possibility to damage the musculocutaneous nerve. Purpose of the Study: To demonstrate that transplantation of the coracoid process with its tendon attachments through a split in the subscapularis muscle and tendon without shifting the capsula gives better results then transplant of the coracoid process with capsule-labral repair. The goal of this report is to review the result of our series. Patients and Methods: Between January 2000 and June 2005, 26 Latarjete operations (Rockwood modification) were performed by the senior author. The indication for surgery was failed artroscopic Bankart repair or anterior shoulder instability associated with anterior inferior glenoid deficiencies (“inverted pear” deformity). Five cases were excluded having less than 6 months follow-up. In the first 5 cases in addition to the coracoid process transfer, labral repair with capsular shift was performed whereas in the next 21 cases only coracoid process transplant with excision of the damaged labrum/scar tissue and no capsular shift was performed. The postoperative rehabilitation program was the same for both groups. The patients age and sex was very close in both groups. The parameters for comparison between the two groups were: range of motion, stability after 6 months, return to work and sport activity, satisfaction, and complication rate. Results: 6 months after surgery all patients of both groups returned to full work and sport activity including contact sports. No recurrent dislocation was encountered during this short period of follow up. All patients who underwent this procedure, with or without capsule-labral repair, were satisfied with the procedure. In the small group that included capsulo-labral repair an average of 10 degrees decrease of external rotation was encountered compared to the opposite shoulder. In the second group no decrease in range of motion was found. Conclusion: Transfer of the coracoid process through the subscapularis tendon alone has better results then Latarjete operation complemented with capsulo-labral repair in regard of range of motion. The procedure is simple and of short duration giving the best solution for failed artroscopic procedures or for cases of shoulder instability having anterior inferior glenoid deficiencies. The authors are aware that longer follow up is mandatory


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1096 - 1101
1 Aug 2005
Maynou C Cassagnaud X Mestdagh H

We compared the long-term function of subscapularis after the Latarjet procedure using two surgical approaches. We treated 102 patients (106 shoulders) with a mean age of 26.8 years (15 to 51) with involuntary unidirectional recurrent instability. The operation was carried out through an L-shaped incision with trans-section of the upper two-thirds of the muscle in 69 cases and with a subscapularis split in 37. All clinical results were assessed by the Rowe and the Duplay scores and the function of subscapularis by evaluating the distance and strength at the lift-off position. Bilateral CT was performed in 77 patients for assessment of fatty degeneration. The mean follow-up was 7.5 years (2 to 15) and 18% of cases were lost to follow-up. The mean Duplay score was 82 of 100 for the L-shaped incision group and 90 of 100 for those with a subscapularis split (p = 0.02). The mean fatty degeneration score was 1.18 after an L-shaped incision compared with 0.12 after subscapularis split (p = 0.001). The subscapularis split approach is therefore recommended.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 118 - 118
1 Apr 2005
Gosselin O Sirveaux F Roche O Villavueva E Marchal C Molé D
Full Access

Purpose: The purpose of this study was to assess long-term functional outcome after arthroscopic acromioplasty for full-thickness rotator cuff tears, to evaluate the efficacy of complementary procedures (biceps tenotomy, extended acromioclavicular resection), and to examine the course of anatomic lesions. Material and methods: From 1988 to 1994, 141 full-thickness rotator cuff tears were treated by arthroscopic acromioplasty. Ninety-eight patients, mean age 60 years, were reviewed clinically, radiographically, and sonographically at more than eight years. The mean preoperative Constant score was 48.5 points. The tear involved the supraspinatus in 18 cases, the supraspinatus and infraspinatus in 40, the supraspinatus and the subscapularis in ten, and all three tendons in 20. Coronal extension showed a distal tear in four, an intermediate tear in 52, and a retracted stump in 32. Systemic acromioplasty was associated in 36 patients with tenotomy of the long head of the brachial biceps and in 44 with acromioclavicular extension. Results: At mean follow-up of 10.7 years (8–13.5), the mean Constant score was 60 points. The clinical outcome was excellent or good in 39.7%, fair in 45.5%, and poor in 14.8. 62.5% of the patients were satisfied or very satisfied. The height of the subacromial space was 5.19 mm at last follow-up compared with 4.3 mm preoperatively. The antalgesic effect of biceps tenotomy was significant when the initial acromiohumeral space was less than 5 mm. This procedure did not produce any significant change in the subacromial height or development of osteoarthritis at last follow-up. Sonography showed stability of the size of the tear in 83.8% of the cases. The results were significantly less satisfactory when the initial tear involved the subscapularis or all three tendons. Conclusion: The clinical results of arthroscopic acropmioplasty for full-thickness tears show long-term stability. Biceps tenotomy improves the antalgesic effect significantly, particularly if the subachromial space measures less than 5 mm preoperatively, without causing significant radiological degradation. Extension to the acromioclavicular level should be systematic in patients with acromioclavicular pain preoperatively and/or radiological anomalies


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 348 - 351
1 Mar 2005
Kreuz PC Remiger A Lahm A Herget G Gächter A

We treated surgically 16 shoulders with an isolated traumatic rupture of the subscapularis tendon over a six-year period. Nine patients had a total and seven a partial tear of the subscapularis tendon. Repair was undertaken through a small deltopectoral groove approach. The mean Constant score improved in total tears from 38.7 to 89.3 points (p = 0.003) and in partial tears from 50.7 to 87.9 points (p = 0.008). The total tears were significantly more improved by surgery than the partial tears (p = 0.001). The delay between trauma and surgery was inversely proportional to the improvement in the Constant score suggesting that early diagnosis and surgical repair improves outcome


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 177 - 177
1 Jul 2002
Seitz W
Full Access

Internal rotation contracture/tightness presents a functional problem for the patient and a technical challenge for the surgeon performing total shoulder arthroplasty most commonly occurring in cases of osteoarthritis. Internal rotation contractures result from a number of physiologic and biomechanical conditions. Osteophytes, which form around the head and neck of the humerus and glenoid provide a mechanical block to external rotation, which occurs over time. The inability to pass through a full excursion of external rotation tightens the anterior capsular structures over time and causes a contracture of the musculotendinous units (subscapularis and pectoralis major), responsible for internal rotation. The osteophytes themselves also change the vector of pull of the internal rotators and cause them to be “tented” anteriorly. Hence the issues causing an internal rotation contracture and inhibiting external rotation following total shoulder arthroplasty include a mechanical bone block, diminished tissue compliance and abnormal tendon excursion. Management of this problem has frequently been focused predominantly on fractional lengthening the subscapularis tendon, but all components must be addressed at the time of surgery to make sure that a functional range of motion in external rotation can be achieved following reconstruction. This video details the assessment of each of these components and their management. Surgical technique includes: resection of all obstructive osteophytes which block rotation and which cause abnormal tendon excursion; adequate head removal and shaping to provide restoration of an anatomical arc of curvature of the humeral head in continuity with the metaphyseal support base, adequate release of upper pectoralis major tendon tightness, release of capsular contractures and adhesions about the subscapularis muscle and tendon; and fractional lengthening of the subscapularis muscle-tendon itself to allow adequate healthy reattachment of the subscapularis tendon to the more superior aspects of the rotator cuff without allowing anterior instability to occur. Attention to the myotendinous junction rather than thinning the tendon itself has proven to be important in achieving a healthy tendon attachment without significant attenuation. Appropriate seating of the humeral head in anatomic version is also important to prevent unnatural distention of the anterior structures. These surgical techniques should help the surgeon provide an anatomic restoration of motion and function