Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 2 - 2
22 Nov 2024
Roskar S Faganeli N Mihalic R Trebse R
Full Access

Aim. Arthroscopic interventions have revolutionized the treatment of joint pathologies. The appropriate diagnostics and treatment are required for infections after ligament reconstructions using non-resorbable material such as tendon grafts, anchors, and sutures, prone to biofilm formation. The infection rate is around 1% for knee and shoulder, while up to 4% for Achilles tendon reconstructions. Despite high number of these procedures worldwide, there is limited evidence about the best treatment protocol. Our study aimed to provide a general protocol for the treatment of small implants for soft tissue reconstruction. Method. Between 2019 and 2023, we treated 48 infections of ligament, meniscus, and tendon reconstructions out of 7291 related procedures performed in the same time period. Early infection (<30 days) were treated with an arthroscopic debridement and implant retention (DAIR), except Achilles tendons had open DAIR, while those with delayed or chronic infection (>30 days) were treated with extensive debridement and lavage combined with one-stage exchange (OSE) or implant removal. During surgery, at least 5 microbiological s and samples for histopathology were obtained. The removed material was sonicated. After surgery, all patients were one week on iv. antibiotics, followed by oral antibiofilm antibiotics for 6 weeks including rifampicin and/or a quinolone. All patients were followed for at least 1 year. Failure was defined as the need for additional revision surgery after finished iv. antibiotic treatment. Results. Among 48 patients, 38 were early and 10 were late acute or chronic infections. The incidence of infection for our cohort was 0.7%. We observed 27 infections after ligament reconstruction of the knee, 15 of the shoulder, 5 of the ankle, and 1 infection of the elbow joint. 40 patients were treated with DAIR, 5 with OSE, and 3 with implant removal. We had 11 C. acnes, 10 S. aureus, 6 S. epidermidis, 2 P. aeruginosa, 2 S. lugdunensis, 10 mixed flora, and 3 culture-negative infections. 12 patients received antibiotics before surgery, and all culture-negative infections were related to this subgroup. We observed 2 failures, both in a combination of proximal tibial osteotomy and ligament reconstruction of the knee joint. The success rate of our protocol was 96%. Conclusions. Prompt surgical treatment followed by 6 weeks of antibiotic treatment cured 96% of infections of small implants after reconstruction procedures of knee, shoulder, and ankle joints. Our study is the first to provide a treatment protocol for infections of small implants after ligament reconstruction procedures


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 38 - 38
22 Nov 2024
Barros BS Costa B Ribau A Vale J Sousa R
Full Access

Aim. Accurate diagnosis is key in correctly managing prosthetic joint infection(PJI). Shoulder PJI definition and diagnosis is challenging. Current PJI definitions, based overwhelmingly in hip/knee research, may not accurately diagnose shoulder PJI. Our aim is to compare the preoperative performance of two PJI definitions comparing it to definitive postoperative classification. Method. This is a retrospective study of patients who have undergone total shoulder revision surgery for infection between 2005 and 2022. Cases were classified using two different PJI definitions: a)the European Bone and Joint Infection Society (EBJIS) and; 2)the 2018 International Consensus Meeting(ICM) PJI specific shoulder definition. Preoperative classification was based on clinical features, inflammatory markers and synovial fluid leukocyte count and definitive classification also considered microbiology and histology results. Results. Preoperative and definitive PJI classification status of the 21 patients included were evaluated and is summarized in table 1. The shoulder specific 2018 ICM definition showed the highest agreement between preoperative and definitive classification (76.2%, k=0.153, p=0.006) compared to EBJIS (52.4%, k=0.205, p=0.006). In all cases, the classification was changed because of positive intraoperative microbiology (at least two identical isolates). Microbiology findings showed coagulase negative staphylococci, Staphyloccocus aureus and Cutibacterium acnes to be the most frequent. Four patients had polymicrobial infections. Conclusions. Both the EBJIS 2021 and 2018 ICM definitions have low accuracy in predicting shoulder PJI preoperatively. Clearly further studies with larger cohorts are in dire need focusing specifically on shoulder revision arthroplasty to improve on existing definitions. Caution is advised while extrapolating of criteria/thresholds recommended for hip/knee joints. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 15 - 15
22 Nov 2024
Liew-Littorin C Davidsson S Nilsdotter-Augustinsson Å Brueggemann H Söderquist B
Full Access

Aim. Cutibacterium acnes is a major skin commensal that may also act as an opportunistic pathogen. Findings of C. acnes in tissue cultures obtained during arthroplasty revision surgery are difficult to interpret, since they may represent true infection or contamination. This study investigated whether C. acnes isolates obtained from prosthetic joint infections (PJIs) were related and shared common genomic traits that might correlate with clinical courses and patient outcomes. Method. C. acnes isolates from revision surgery of patients with PJIs of the hip, shoulder, and knee were characterized using molecular methods to determine sequence type (ST) and the presence of virulence determinants (CAMP factors, dermatan sulfate-binding adhesion 1, hyaluronidase lyase, and linear plasmid). A standardized review of the patients’ medical charts was performed. Results. The study included 37 patients with C. acnes culture-positive tissue samples where multiple isolates of C. acnes belonged to the same ST. Most of the isolates belonged to phylotype IA. 1. Phylogenetic analysis of virulence determinants revealed no shared pattern among PJI isolates. Seven patients had a polymicrobial infection. Exchange revision was performed in 70% of the patients, and >50% of all patients received antibiotic treatment for ≥3 months. Failure was noted in seven patients, all of whom had shoulder PJIs. Conclusions. No specific ST or any identifiable unique feature among virulence determinants were found among C. acnes isolated from PJIs of hips and shoulders. The majority of all included patients had low inflammatory markers and were treated successfully, even when the infection consisted of a polymicrobial infection


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1041 - 1048
19 Nov 2024
Delgado C Martínez-Rodríguez JM Candura D Valencia M Martínez-Catalán N Calvo E

Aims

The Bankart and Latarjet procedures are two of the most common surgical techniques to treat anterior shoulder instability with satisfactory clinical and functional outcomes. However, the outcomes in the adolescent population remain unclear, and there is no information regarding the arthroscopic Latarjet in this population. The purpose of this study was to evaluate the outcomes of the arthroscopic Bankart and arthroscopic Latarjet procedures in the management of anterior shoulder instability in adolescents.

Methods

We present a retrospective, matched-pair study of teenagers with anterior glenohumeral instability treated with an arthroscopic Bankart repair (ABR) or an arthroscopic Latarjet (AL) procedure with a minimum two-year follow-up. Preoperative demographic and clinical features, factors associated with dislocation, and complications were collected. Recurrence, defined as dislocation or subluxation, was established as the primary outcome. Clinical and functional outcomes were analyzed using objective (Rowe), and subjective (Western Ontario Shoulder Instability Index (WOSI) and Single Assessment Numeric Evaluation (SANE)) scores. Additionally, the rate of return to sport was assessed.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 32 - 32
14 Nov 2024
Mungalpara N Kim S Baker H Lee C Shakya A Chen K Athiviraham A Koh J Elhassan B Maassen NH Amirouche F
Full Access

Introduction. Supraspinatus and infraspinatus tears (Massive Rotator Cuff Tear- MRCT) cause compensatory activation of the teres minor (TM) and subscapularis (SubS) to maintain humeral head alignment. This study measures force changes in TM and SubS using a dynamic shoulder testing setup. We hypothesize that combining superior capsule reconstruction (SCR) and lower trapezius tendon (LTT) transfer will correct rotator cuff forces. Methods. Eight fresh-frozen human shoulder specimens from donors aged 55-75 (mean = 63.75 years), balanced for gender, averaging 219.5 lbs, were used. Rotator cuff and deltoid tendons were connected to force sensors through a pulley system, with the deltoid linked to a servohydraulic motor for dynamic force measurement. The system allowed unrestricted humeral abduction from 0 to 90 degrees. Results. Teres Minor (TM):. -. Control: 7.43 N (SD = 1.66). -. SS tear: 5.46 N (SD = 1.45). -. MRCT: 3.94 N (SD = 1.43). -. LTT post-MRCT: 5.85 N (SD = 1.13). -. SCR post-MRCT: 4.68 N (SD = 0.71). -. Combined LTT+SCR: 6.43 N (SD = 1.24). -. TM force reduction: 26.51% post-SS tear, 46.97% from intact to MRCT, 63.20% increase with LTT+SCR. Subscapularis (SubS):. -. Control: -0.73 N (SD = 0.43). -. SS tear: -0.46 N (SD = 0.36), 36.99% increase. -. MRCT: 0.96 N (SD = 0.47), 31.51% increase. -. LTT post-MRCT: -0.32 N (SD = 0.47), 66.67% reduction. -. SCR post-MRCT: -0.28 N (SD = 0.16), 70.83% reduction. -. Combined LTT+SCR: -0.66 N (SD = 0.32), 31.25% reduction. Non-parametric Friedman's ANOVA showed overall statistical significance for TM (P = 1.083×10. -6. ) and SubS (P = 4.77×10. -4. ). Conclusion. The cadaveric model assesses rotator cuff compensations, showing significant TM force reductions following rotator cuff tears and improvements with LTT and SCR, particularly when combined. SubS exhibited negative force during normal abduction but compensated during MRCT, returning to normal values post-LTT and SCR


Introduction. This study aims to investigate the relationship between ulnar fixation and postoperative satisfaction among patients with distal radius fractures accompanied by ulna styloid fractures, with a particular focus on how sociodemographic factors influence outcomes. Method. A retrospective cohort study was conducted involving 120 patients aged 26-53 who underwent surgical treatment for distal radius fractures with concomitant ulna styloid fractures between January 2018 and December 2022. Patients were divided into two groups based on whether ulnar fixation was performed. Sociodemographic data, including age, gender, socioeconomic status, education level, and occupation, were collected. All patients underwent similar physical therapy protocols in the postoperative period, and no complications were observed in any patient. Postoperative satisfaction was assessed using the Patient-Rated Wrist Evaluation (PRWE) and the Disabilities of the Arm, Shoulder, and Hand (DASH) scores at 6 and 12 months post-surgery. Statistical analysis was conducted to evaluate the influence of ulnar fixation and sociodemographic factors on patient satisfaction. Result. Patients who underwent ulnar fixation (n=60) reported significantly higher satisfaction levels compared to those who did not (n=60), as evidenced by lower PRWE and DASH scores (p < 0.05). Age, gender, and socioeconomic status were significant predictors of postoperative satisfaction. Younger patients, females, and those with higher socioeconomic status exhibited greater improvements in functional outcomes and satisfaction. However, education level and occupation did not significantly influence satisfaction scores. Conclusion. Ulnar fixation in the surgical treatment of distal radius fractures accompanied by ulna styloid fractures is associated with improved postoperative satisfaction. Sociodemographic factors, particularly age, gender, and socioeconomic status, play a crucial role in patient-reported outcomes. Tailoring postoperative care to address these sociodemographic differences may enhance overall patient satisfaction and recovery


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 95 - 95
14 Nov 2024
Machain TC Kharchenko A Hostettler R Lippl J Mouthuy PA
Full Access

Introduction. Supraspinatus tears comprise most rotator cuff injuries, the leading cause of shoulder pain and an increasing problem with ageing populations. Surgical repair of considerable or persistent damages is customary, although not invariably successful. Tissue engineering presents a promising alternative to generate functional tissue constructs with improved healing capacities. This study explores tendon tissue constructs’ culture in a platform providing physiological mechanical stimulation and reports on the effect of different loading regimes on the viability of human tendon cells. Method. Porcine decellularized tendon scaffolds were fixed into flexible, self-contained bioreactor chambers, seeded with human tenocytes, allocated in triplicates to either static control, low (15±0.8Newtons [N]), medium (26±0.5N), or high (49±2.1N)-force-regime groups, connected to a perfusion system and cultured under standard conditions. A humanoid robotic arm provided 30-minute adduction/abduction stimulation to chambers daily over a week. A metabolic activity assay served to assess cell viability at four time points. Statistical significance = p<0.05. Result. One day after beginning mechanical stimulation, chambers in the medium and high-force regimes displayed a rise in metabolic activity by 3% and 5%, respectively. By the last experimental day, all mechanical stimulation regimes had induced an augment in cell viability (15%, 57% and 39% with low, medium, and high loads, respectively) matched against the static controls. Compared to all other conditions, the medium-force regime prompted an increased relative change in metabolic activity for every time point set against day one (p<0.05). Conclusion. Human tenocytes’ viability reflected by metabolic activity in a physiologically relevant bioreactor system is enhanced by loading forces around 25N when mechanically stimulating using adduction/abduction motions. Knowing the most favourable load regime to stimulate tenocyte growth has informed the ongoing exploration of the distinctive effect of different motions on tendon regeneration towards engineering tissue grafts. This work was supported by the Engineering and Physical Sciences Research Council EP/S003509/1


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 105 - 105
14 Nov 2024
Spoo S Garcia F Braun B Cabri J Grimm B
Full Access

Introduction. The objective assessment of shoulder function is important for personalized diagnosis, therapies and evidence-based practice but has been limited by specialized equipment and dedicated movement laboratories. Advances in AI-driven computer vision (CV) using consumer RGB cameras (red-blue-green) and open-source CV models offer the potential for routine clinical use. However, key concepts, evidence, and research gaps have not yet been synthesized to drive clinical translation. This scoping review aims to map related literature. Method. Following the JBI Manual for Evidence Synthesis, a scoping review was conducted on PubMed and Scholar using search terms including “shoulder,” “pose estimation,” “camera”, and others. From 146 initial results, 27 papers focusing on clinical applicability and using consumer cameras were included. Analysis employed a Grounded Theory approach guided iterative refinement. Result. Studies primarily used Microsoft Kinect (infrared-based depth sensing, RGB camera; discontinued) or monocular consumer cameras with open-source CV-models, sometimes supplemented by LiDAR (laser-based depth sensing), wearables or markers. Technical validation studies against gold standards were scarce and too inconsistent for comparison. Larger range of motion (RoM) movements were accurately recorded, but smaller movements, rotations and scapula tracking remained challenging. For instance, one larger validation study comparing shoulder angles during arm raises to a marker-based gold-standard reported Pearson's R = 0.98 and a standard error of 2.4deg. OpenPose and Mediapipe were the most used CV-models. Recent efforts try to improve model performance by training with shoulder specific movements. Conclusion. Low-cost, routine clinical movement analysis to assess shoulder function using consumer cameras and CV seems feasible. It can provide acceptable accuracy for certain movement tasks and larger RoM. Capturing small, hidden or the entirety of shoulder movement requires improvements such as via training models with shoulder specific data or using dual cameras. Technical validation studies require methodological standardization, and clinical validation against established constructs is needed for translation into practice


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 60 - 60
14 Nov 2024
Asgari A Shaker F Fallahy MTP Soleimani M Shafiei SH Fallah Y
Full Access

Introduction. Shoulder arthroplasty (SA) has been performed with different types of implants, each requiring different replacement systems. However, data on previously utilized implant types are not always available before revision surgery, which is paramount to determining the appropriate equipment and procedure. Therefore, this meta-analysis aimed to evaluate the accuracy of the AI models in classifying SA implant types. Methods. This systematic review was conducted in Pubmed, Embase, SCOPUS, and Web of Science from inception to December 2023, according to PRISMA guidelines. Peer-reviewed research evaluating the accuracy of AI-based tools on upper-limb X-rays for recognizing and categorizing SA implants was included. In addition to the overall meta-analysis, subgroup analysis was performed according to the type of AI model applied (CNN (Convolutional neural network), non-CNN, or Combination of both) and the similarity of utilized datasets between studies. Results. 13 articles were eligible for inclusion in this meta-analysis (including 138 different tests assessing models’ efficacy). Our meta-analysis demonstrated an overall sensitivity and specificity of 0.891 (95% CI:0.866-0.912) and 0.549 (95% CI:0.532,0.566) for classifying implants in SA, respectively. The results of our subgroup analyses were as follows: CNN-subgroup: a sensitivity of 0.898 (95% CI:0.873-0.919) and a specificity of 0.554 (95% CI:0.537,0.570), Non-CNN subgroup: a sensitivity of 0.809 (95% CI:0.665-0.900) and specificity of 0.522 (95% CI:0.440,0.603), combined subgroup: a sensitivity of 0.891 (95% CI:0.752-0.957) and a specificity of 0.547 (95% CI:0.463,0.629). Studies using the same dataset demonstrated an overall sensitivity and specificity of 0.881 (95% CI:0.856-0.903) and 0.542 (95% CI:0.53,0.554), respectively. Studies that used other datasets showed an overall sensitivity and specificity of 0.995 (95% CI:969,0.999) and 0.678 (95% CI:0.234, 0.936), respectively. Conclusion. AI-based classification of shoulder implant types can be considered a sensitive method. Our study showed the potential role of using CNN-based models and different datasets to enhance accuracy, which could be investigated in future studies


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 81 - 81
14 Nov 2024
Ahmed NA Narendran K Ahmed NA
Full Access

Introduction. Anterior shoulder instability results in labral and osseous glenoid injuries. With a large osseous defect, there is a risk of recurrent dislocation of the joint, and therefore the patient must undergo surgical correction. An MRI evaluation of the patient helps to assess the soft tissue injury. Currently, the volumetric three-dimensional (3D) reconstructed CT image is the standard for measuring glenoid bone loss and the glenoid index. However, it has the disadvantage of exposing the patient to radiation and additional expenses. This study aims to compare the values of the glenoid index using MRI and CT. Method. The present study was a two-year cross-sectional study of patients with shoulder pain, trauma, and dislocation in a tertiary hospital in Karnataka. The sagittal proton density (PD) section of the glenoid and enface 3D reconstructed images of the scapula were used to calculate glenoid bone loss and the glenoid index. The baseline data were analyzed using descriptive statistics, and the Chi-square test was used to test the association of various complications with selected variables of interest. Result. The glenoid index calculated in the current study using 3D volumetric CT images and MR sagittal PD images was 0.95±0.01 and 0.95±0.01, respectively. The CT and MRI glenoid bone loss was 5.41±0.65% and 5.38±0.65%, respectively. When compared, the glenoid index and bone loss calculated by MRI and CT revealed a high correlation and significance with a p-value of <0.001. Conclusions. The study concluded that MRI is a reliable method for glenoid measurement. The sagittal PD sequence combined with an enface glenoid makes it possible to identify osseous defects linked to glenohumeral joint damage and dislocation. The values derived from 3D CT are identical to the glenoid index and bone loss determined using the sagittal PD sequence in MRI


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 47 - 47
14 Nov 2024
Daneshvarhashjin N Debeer P Andersen MS Verhaegen F Scheys L
Full Access

Introduction. Assessment of the humeral head translation with respect to the glenoid joint, termed humeral head migration (HHM), is crucial in total shoulder arthroplasty pre-operative planning. Its assessment informs current classification systems for shoulder osteoarthritis as well as the evaluation of surgical correction. In current clinical practice, HHM assessment relies on computed-tomography (CT) imaging. However, the associated supine position might undermine its functional relevance as it does not reflect the weight-bearing condition with active muscle engagement associated with the upright standing position of most daily activities. Therefore, we assessed to what extent HHM in a supine position is associated with HHM in a range of functional arm positions. Method. 26 shoulder osteoarthritis patients and 12 healthy volunteers were recruited. 3D shapes of the humerus and scapula were reconstructed from their respective CT scans using an image processing software. 3. , and their CT-scan-based HHMs were measured. Furthermore, all subjects underwent low-dose biplanar radiography . 4. in four quasi-static functional arm positions while standing: relaxed standing, followed by 45 degrees of shoulder extension, flexion, and abduction. Using a previously validated method implemented in the programming platforms. 5. , 3D shapes were registered to the pairs of biplanar images for each arm position and the corresponding functional HHM was measured. Bivariate correlations were assessed between the CT-based HHM and each functional arm position. Result. HHM in 45 degrees of flexion and extension both showed significant and strong correlations (r>0.66 and P<0.01) with HHM assessed in the supine position. However, such a high correlation was not found for relaxed standing and 45 abduction. Conclusion. Although HHM in a supine position correlates with HHM in 45-degree extension and flexion, it is poorly associated with the HHM in abduction and relaxed standing. These results may suggest the inclusion of more functionally-relevant patient positioning toward better-informed shoulder arthroplasty planning. Acknowledgement. Funding from PRosPERos-II Project


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 125 - 125
14 Nov 2024
Mungalpara N Kim S Baker H Lee C Shakya A Chen K Athiviraham A Koh J Elhassan B Maassen NH Amirouche F
Full Access

Introduction. Treatment strategies for irreparable Massive Rotator Cuff Tears (MRCTs) are debatable, especially for younger, active patients. Superior Capsular Reconstruction (SCR) acts as a static stabilizer, while Lower Trapezius Transfer (LTT) serves as a dynamic stabilizer. This study compares the biomechanical effectiveness of SCR and LTT, hypothesizing that their combination will enhance shoulder kinematics. Methods. Eight human shoulders from donors aged 55-75 (mean = 63.75 years), balanced for gender, averaging 219.5 lbs, were used. Rotator cuff and deltoid tendons were connected to force sensors through a pulley system, with the deltoid linked to a servohydraulic motor for dynamic force measurement. Results. From intact to MRCT, deltoid force was reduced by 28% (p = 0.023). LTT increased deltoid force by 27.25 (p = 0.166). SCR decreased deltoid force by 34% (p = 0.208). Combining LTT with SCR increased deltoid force by 32.57% compared to SCR (p = 0.023) and decreased it by 13.6% compared to LTT alone (p = 0.017). Combined LTT and SCR reduced deltoid force by 20.9% from the control (p = 0.001). Subacromial contact pressure rose by 15% in MRCT over intact, but LTT decreased it by 7.6%, achieving nearly 50% correction. SCR increased subacromial space volume, raising pressure by 6.5%. The humeral head translation (HHT) increases with MRCT, reaching 3.33 mm (SD = 0.95) at 0 degrees, compared to 2.24 mm (SD = 0.78) in the intact. LTT and the combined LTT + SCR significantly reduce HHT, with combined LTT + SCR achieving HHT of 2.24 mm (SD = 0.63) at 0 degrees, comparable to the control. Conclusion. Notable changes in deltoid force were observed. LTT outperformed the combined SCR and LTT in reducing deltoid force and subacromial peak pressure. Both SCR and LTT corrected HTT, with LTT being more effective. However, combining SCR and LTT optimally corrected HHT


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1263 - 1272
1 Nov 2024
Amador IE Hao KA Buchanan TR Damrow DS Hones KM Simcox T Schoch BS Farmer KW Wright TW LaMonica TJ King JJ Wright JO

Aims. We sought to compare functional outcomes and survival between non-smokers, former smokers, and current smokers who underwent anatomical total shoulder arthroplasty (aTSA) in a large cohort of patients. Methods. A retrospective review of a prospectively collected shoulder arthroplasty database was performed between August 1991 and September 2020 to identify patients who underwent primary aTSA. Patients were excluded for preoperative diagnoses of fracture, infection, or oncological disease. Three cohorts were created based on smoking status: non-smokers, former smokers, and current smokers. Outcome scores (American Shoulder and Elbow Surgeons (ASES), Constant-Murley score, Shoulder Pain and Disability Index (SPADI), Simple Shoulder Test (SST), University of California, Los Angeles activity scale (UCLA)), range of motion (external rotation (ER), forward elevation (FE), internal rotation, abduction), and shoulder strength (ER, FE) evaluated at two- to four-year follow-up were compared between cohorts. Evaluation of revision-free survival was performed using the Kaplan-Meier method to final follow-up. Results. We included 428 primary aTSAs with a mean follow-up of 2.4 years (SD 0.6). Our cohort consisted of 251 non-smokers, 138 former smokers who quit a mean 21 years (SD 14) prior to surgery (25 pack-years (SD 22)), and 39 current smokers (23 pack-years (SD 20)). At two- to four-year follow-up, former smokers had less favourable SPADI, SST, and FE strength compared to non-smokers, and current smokers had less favourable SPADI, SST, ASES score, UCLA score, Constant-Murley score, FE, abduction, and ER strength compared to non-smokers. Non-smokers exhibited higher revision-free survival rates at two, five, eight, and ten years postoperatively compared to former smokers and current smokers, who had similar rates. Conclusion. Our study suggests that smoking has a negative effect on aTSA functional outcomes that may persist even after quitting. Cite this article: Bone Joint J 2024;106-B(11):1263–1272


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1306 - 1311
1 Nov 2024
Watts AC McDaid C Hewitt C

Aims

A review of the literature on elbow replacement found no consistency in the clinical outcome measures which are used to assess the effectiveness of interventions. The aim of this study was to define core outcome domains for elbow replacement.

Methods

A real-time Delphi survey was conducted over four weeks using outcomes from a scoping review of 362 studies on elbow replacement published between January 1990 and February 2021. A total of 583 outcome descriptors were rationalized to 139 unique outcomes. The survey consisted of 139 outcomes divided into 18 domains. The readability and clarity of the survey was determined by an advisory group including a patient representative. Participants were able to view aggregated responses from other participants in real time and to revisit their responses as many times as they wished during the study period. Participants were able to propose additional items for inclusion. A Patient and Public Inclusion and Engagement (PPIE) panel considered the consensus findings.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1293 - 1300
1 Nov 2024
O’Malley O Craven J Davies A Sabharwal S Reilly P

Aims. Reverse shoulder arthroplasty (RSA) has become the most common type of shoulder arthroplasty used in the UK, and a better understanding of the outcomes after revision of a failed RSA is needed. The aim of this study was to review the current evidence systematically to determine patient-reported outcome measures and the rates of re-revision and complications for patients undergoing revision of a RSA. Methods. MEDLINE, Embase, CENTRAL, and the Cochrane Database of Systematic Reviews were searched. Studies involving adult patients who underwent revision of a primary RSA for any indication were included. Those who underwent a RSA for failure of a total shoulder arthroplasty or hemiarthroplasty were excluded. Pre- and postoperative shoulder scores were evaluated in a random effects meta-analysis to determine the mean difference. The rates of re-revision and complications were also calculated. Results. The initial search elicited 3,166 results and, following removal of duplicates and screening, 13 studies with a total of 1,042 RSAs were identified. An increase in shoulder scores pre- to postoperatively was reported in all the studies. Following revision of a RSA to a further RSA, there was a significant increase in the American Shoulder and Elbow Surgeons Score (mean difference 20.78 (95% CI 8.16 to 33.40); p = 0.001). A re-revision rate at final follow-up ranging from 9% to 32%, a one-year re-revision rate of 14%, and a five-year re-revision rate of 23% were reported. The complication rate in all the studies was between 18.5% and 36%, with a total incidence of 29%. Conclusion. This is the largest systematic review of the outcomes following revision of a RSA. We found an improvement in functional outcomes after revision surgery, but the rates of re-revision and complications are high and warrant consideration when planning a revision procedure. Cite this article: Bone Joint J 2024;106-B(11):1293–1300


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1321 - 1326
1 Nov 2024
Sanchez-Sotelo J

Periprosthetic joint infection represents a devastating complication after total elbow arthroplasty. Several measures can be implemented before, during, and after surgery to decrease infection rates, which exceed 5%. Debridement with antibiotics and implant retention has been reported to be successful in less than one-third of acute infections, but still plays a role. For elbows with well-fixed implants, staged retention seems to be equally successful as the more commonly performed two-stage reimplantation, both with a success rate of 70% to 80%. Permanent resection or even amputation are occasionally considered. Not uncommonly, a second-stage reimplantation requires complex reconstruction of the skeleton with allografts, and the extensor mechanism may also be deficient. Further developments are needed to improve our management of infection after elbow arthroplasty.

Cite this article: Bone Joint J 2024;106-B(11):1321–1326.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1273 - 1283
1 Nov 2024
Mahmud H Wang D Topan-Rat A Bull AMJ Heinrichs CH Reilly P Emery R Amis AA Hansen UN

Aims. The survival of humeral hemiarthroplasties in patients with relatively intact glenoid cartilage could theoretically be extended by minimizing the associated postoperative glenoid erosion. Ceramic has gained attention as an alternative to metal as a material for hemiarthroplasties because of its superior tribological properties. The aim of this study was to assess the in vitro wear performance of ceramic and metal humeral hemiarthroplasties on natural glenoids. Methods. Intact right cadaveric shoulders from donors aged between 50 and 65 years were assigned to a ceramic group (n = 8, four male cadavers) and a metal group (n = 9, four male cadavers). A dedicated shoulder wear simulator was used to simulate daily activity by replicating the relevant joint motion and loading profiles. During testing, the joint was kept lubricated with diluted calf serum at room temperature. Each test of wear was performed for 500,000 cycles at 1.2 Hz. At intervals of 125,000 cycles, micro-CT scans of each glenoid were taken to characterize and quantify glenoid wear by calculating the change in the thickness of its articular cartilage. Results. At the completion of the wear test, the total thickness of the cartilage had significantly decreased in both the ceramic and metal groups, by 27% (p = 0.019) and 29% (p = 0.008), respectively. However, the differences between the two were not significant (p = 0.606) and the patterns of wear in the specimens were unpredictable. No significant correlation was found between cartilage wear and various factors, including age, sex, the size of the humeral head, joint mismatch, the thickness of the native cartilage, and the surface roughness (all p > 0.05). Conclusion. Although ceramic has better tribological properties than metal, we did not find evidence that its use in hemiarthroplasty of the shoulder in patients with healthy cartilage is a better alternative than conventional metal humeral heads. Cite this article: Bone Joint J 2024;106-B(11):1273–1283


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1284 - 1292
1 Nov 2024
Moroder P Poltaretskyi S Raiss P Denard PJ Werner BC Erickson BJ Griffin JW Metcalfe N Siegert P

Aims. The objective of this study was to compare simulated range of motion (ROM) for reverse total shoulder arthroplasty (rTSA) with and without adjustment for scapulothoracic orientation in a global reference system. We hypothesized that values for simulated ROM in preoperative planning software with and without adjustment for scapulothoracic orientation would be significantly different. Methods. A statistical shape model of the entire humerus and scapula was fitted into ten shoulder CT scans randomly selected from 162 patients who underwent rTSA. Six shoulder surgeons independently planned a rTSA in each model using prototype development software with the ability to adjust for scapulothoracic orientation, the starting position of the humerus, as well as kinematic planes in a global reference system simulating previously described posture types A, B, and C. ROM with and without posture adjustment was calculated and compared in all movement planes. Results. All movement planes showed significant differences when comparing protocols with and without adjustment for posture. The largest mean difference was seen in external rotation, being 62° (SD 16°) without adjustment compared to 25° (SD 9°) with posture adjustment (p < 0.001), with the highest mean difference being 49° (SD 15°) in type C. Mean extension was 57° (SD 18°) without adjustment versus 24° (SD 11°) with adjustment (p < 0.001) and the highest mean difference of 47° (SD 18°) in type C. Mean abducted internal rotation was 69° (SD 11°) without adjustment versus 31° (SD 6°) with posture adjustment (p < 0.001), showing the highest mean difference of 51° (SD 11°) in type C. Conclusion. The present study demonstrates that accounting for scapulothoracic orientation has a significant impact on simulated ROM for rTSA in all motion planes, specifically rendering vastly lower values for external rotation, extension, and high internal rotation. The substantial differences observed in this study warrant a critical re-evaluation of all previously published studies that examined component choice and placement for optimized ROM in rTSA using conventional preoperative planning software. Cite this article: Bone Joint J 2024;106-B(11):1284–1292


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1312 - 1320
1 Nov 2024
Hamoodi Z Sayers A Whitehouse MR Rangan A Kearsley-Fleet L Sergeant J Watts AC

Aims

The aim of this study was to review the provision of total elbow arthroplasties (TEAs) in England, including the incidence, the characteristics of the patients and the service providers, the types of implant, and the outcomes.

Methods

We analyzed the primary TEAs recorded in the National Joint Registry (NJR) between April 2012 and December 2022, with mortality data from the Civil Registration of Deaths dataset. Linkage with Hospital Episode Statistics-Admitted Patient Care (HES-APC) data provided further information not collected by the NJR. The incidences were calculated using estimations of the populations from the Office for National Statistics. The annual number of TEAs performed by surgeons and hospitals was analyzed on a national and regional basis.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1199 - 1202
1 Nov 2024
Watts AC Tennent TD Haddad FS