Unicompartmental knee arthroplasty (UKA) is associated with an accelerated recovery, improved functional outcomes, and retention of anatomical knee kinematics when compared to manual total knee arthroplasty (mTKA). UKA is not universally employed by all surgeons as there is a higher revision risk when compared to mTKA. Robotic arm-assisted (ra) UKA enables the surgeon to position the prosthesis more accurately when compared to manual UKA, and is associated with improved functional outcomes and a lower early revision risk. Non-randomized data suggests that, when compared to mTKA, raUKA has a clinically meaningful greater functional benefit. This protocol describes a randomized controlled trial that aims to evaluate the clinical and cost-effectiveness of raUKA compared to mTKA for individuals with isolated medial compartment osteoarthritis (OA). The total versus robotic-assisted unicompartmental knee arthroplasty (TRAKER) trial is a patient- and assessor-blinded, pragmatic parallel two-arm randomized superiority trial of adults undergoing elective primary knee arthroplasty for primary medial compartment OA at a single NHS hospital (ClinicalTrials.gov NCT05290818). Participants will be randomly allocated on a 1:2 basis to either raUKA or mTKA, respectively. The primary analysis will compare the Oxford Knee Score (OKS) six months after surgery. Secondary outcomes measured at three, six, and 12 months include the OKS, Forgotten Joint Score, patient expectations, EuroQol five-dimension questionnaire (EQ-5D), and EQ-visual analogue scale (EQ-VAS), patient satisfaction, range of motion, postoperative complications, need for further surgery, resource use, and financial costs. Cost-effectiveness will be measured over a ten-year time span. A total of 159 patients will be randomized (n = 53 raUKA vs n = 106 mTKA) to obtain 80% power to detect a five-point difference in OKS between the groups six months after surgery.Aims
Methods
Aims. The aim of this study was to describe the pattern of revision indications for unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) and any change to this pattern for UKA patients over the last 20 years, and to investigate potential associations to changes in surgical practice over time. Methods. All
In 1975, Sweden started registering
Aim. The primary aim of this study was to examine whether the use of iodine impregnated incision drape (IIID) decreased the risk of periprosthetic joint infections (PJIs). The secondary aim was to investigate whether intraoperative contamination could predict postoperative infection. PJI is a devastating incident for the patients and in a population that is getting older and the incidence of arthroplasty surgery is rising it is vital to keep the infection rate as low as possible. Despite prophylactic measures as pre-operative decontamination, antisepsis and prophylactic antibiotics the infection rate has been constant at 1–2%. Method. We performed a transregional, prospective, randomized two arm study (IIID vs control group) of 1187 patients undergoing
We have increased the dose of tranexamic acid (TXA) in our enhanced total joint recovery protocol at our institution from 15 mg/kg to 30 mg/kg (maximum 2.5 g) as a single, intravenous (IV) dose. We report the clinical effect of this dosage change. We retrospectively compared two cohorts of consecutive patients undergoing total hip arthroplasty (THA) or total knee arthroplasty (TKA) surgery in our unit between 2008 and 2013. One group received IV TXA 15 mg/kg, maximum 1.2 g, and the other 30 mg/kg, maximum 2.5 g as a single pre-operative dose. The primary outcome for this study was the requirement for blood transfusion within 30 days of surgery. Secondary measures included length of hospital stay, critical care requirements, re-admission rate, medical complications and mortality rates.Objectives
Methods
Introduction. The metal-backed patella was originally designed to address shortcomings found with cemented, all-polyethylene patellae. However, complications relating to an all-polyethylene patella were reported to account for up to half of all knee revisions. At the same time, good fixation with bone ingrowth was observed in both titanium and cobalt chromium porous-coated patellae. The advantages provided by using a metal-backed patella, such as uniform load sharing, decreased polyethylene deformation, and potential for biological fixation, may be unjustly outweighed by the fear of patellar component failure; high rates of failure have not been inherent to all metal-backed patella designs. Over the past decade, we have used a metal-backed patella design with excellent results that may be due largely to the design features of the component. Also, we believe there are certain selection criteria that should be strictly adhered to when implanting metal-backed patellae. Correct selection criteria and improved component design strongly indicate the use of press-fit metal-backed patellae. Methods. This single-center study was designed to conduct clinical and independent radiographic review of primary metal-backed, press-fit patella patients with a minimum five-year follow-up. Potential patients were recruited from a group of existing metal-backed patella patients within the principal investigator's medical practice. All patients recruited for this study were required to have undergone
Purpose of the Study. To identify trends in patient satisfaction of their knee arthroplasty, total and unicompartmental, one year post
Implant related hypersensitivity is an infrequent complication after total knee replacement. It remains a relatively unpredictable and poorly understood cause of failure of an implant. We present a report of five patients who presented with persistent hypertrophic synovitis after total knee replacement using a cobalt chrome component. Extensive preoperative and intraoperative attempts ruled out infection as a cause of symptoms. The knees had good ligamentous balance and were well aligned and fixed. The clinical condition improved after revision to a zirconium femoral and titanium metal backed tibial components. Intraoperative histopathology revealed thickened synovium with a predominantly monocellular (lymphocytic or histiocytic) response. Where infection has been excluded as a cause of persistent pain and swelling, consideration should be given to metal allergy as a cause of failure in
The Oxford Knee Score (OKS) is a valid and reliable self-administered patient questionnaire that enables assessment of the outcome following total knee replacement (TKR). There is as yet no literature on the behavioral trends of the OKS over time. Our aim is to present a retrospective audit of the OKS for patients who have undergone TKR during the past ten years. We retrospectively analysed 3276 OKS of patients who had a primary TKR and had been registered as part of a multi-surgeon, outcome-monitoring program at St. Helier hospital. The OKS was gathered pre-operatively and post-operatively by means of postal questionnaires at annual intervals. Patients were grouped as per their age at operation into four groups: 60, 61-70, 71- 80 and >80. A cross-sectional analysis of OKS at different time points was performed. The numbers of OKS available for analysis were 504 pre-operatively, 589 at one-year, 512 at two-year and gradually decreasing numbers with 87 knees ten-year post-operatively. There was as expected a significant decrease (improvement) of the OKS between pre-operative and one-year post-operative period and then reached a plateau. Beyond eight years, there is a gradual rise in the score (deterioration). The younger patients (60) showed a significant increase in their average OKS between one and five-years post-operatively. However beyond five years, they followed the trend of their older counterparts. When the twelve questions in the OKS were analysed, certain components revealed greater improvement (e.g. description of knee pain and limping) than others (e.g. night pain). The OKS is seen to plateau a year after TKR. According to the OKS the outcome of the TKR is not as good in the younger age group as compared to the older age group. Further investigation is required to ascertain the cause of this observed difference.
We obtained pre-operative and six-month post-operative
Oxford hip (OHS) and knee scores (OKS) for 1523 patients who underwent
total hip replacement and 1784 patients who underwent total knee
replacement. They all also completed a six-month satisfaction question. Scatter plots showed no relationship between pre-operative Oxford
scores and six-month satisfaction scores. Spearman’s rank correlation
coefficients were -0.04 (95% confidence interval (CI) -0.09 to 0.01)
between OHS and satisfaction and 0.04 (95% CI -0.01 to 0.08) between
OKS and satisfaction. A receiver operating characteristic (ROC) curve
analysis was used to identify a cut-off point for the pre-operative
OHS/OKS that identifies whether or not a patient is satisfied with
surgery. We obtained an area under the ROC curve of 0.51 (95% CI
0.45 to 0.56) for hip replacement and 0.56 (95% CI 0.51 to 0.60)
for knee replacement, indicating that pre-operative Oxford scores
have no predictive accuracy in distinguishing satisfied from dissatisfied
patients. In the NHS widespread attempts are being made to use patient-reported
outcome measures (PROMs) data for the purpose of prioritising patients
for surgery. Oxford hip and knee scores have no predictive accuracy
in relation to post-operative patient satisfaction. This evidence
does not support their current use in prioritising access to care.
Restoration of the mechanical axis is thought to be a critical factor in determining the Outcome of knee replacement surgery. There is strong theoretical evidence that reproduction of this axis improves mechanical loading and hence longevity of the implant. Clinical studies are small in number. Per-operative use of intra-and-extra-medullary alignment jigs help to determine the distal femoral and proximal tibial cuts. Studies have shown large margins of error using the standard jigs provided with most total knee replacement systems. On this basis computer assisted guidance systems are being introduced such as Orthopilot and BrainLab. These systems allow more accurate placement of the bony cuts and hence improve overall lower limb alignment. No study has shown conclusively that accurately reproducing the mechanical axis of the lower limb improves survivorship of the implant. Prior to investing in these systems we felt it would be prudent to investigate how critical reproduction of the mechanical axis was in the primary total knee replacement. We assessed 100 primary kinematic total knee replacements performed in 1990. All case notes were reviewed looking for basic demographics, pathology and clinical outcome. All cases had a long leg film weight-bearing alignment film taken post-operatively. These were digitised and then analysed using Design CAD 97 software and from this the mechanical axis calculated. Using these data the patients were divided into two groups. The first were within 3 degrees varus/valgus of the mechanical axis. The second were outside this range. These two groups were then correlated to clinical outcome.
Do patients’ recollections of disease severity following joint replacement surgery accurately reflect their pre-operative disability? Oxford Knee score questionnaires were sent to 100 patients who had undergone
Restoration of the mechanical axis is thought to be a critical factor in determining the outcome of knee replacement surgery. There is strong theoretical evidence that reproduction of this axis improves mechanical loading and hence longevity of the implant. Per operative use alignment jigs help to determine the bony cuts. Studies have shown large margins of error using the standard jigs. On this basis computer navigation systems are being introduced. No study has shown conclusively that accurately reproducing the mechanical axis of the lower limb improves survivorship of the implant. Prior to investing in these systems we felt it would be prudent to investigate how critical reproduction of the mechanical axis was in the primary total knee replacement. We assessed 100 primary total knee replacements performed in 1990. All case notes were reviewed looking for basic demographics, pathology, and clinical outcome. All cases had a long leg þlm weight bearing alignment þlm taken post operatively. These were digitised and then analysed using CAD software. From this the mechanical axis calculated. Using this data the patients were divided into two groups. The þrst were within 3 degrees varus/valgus of the mechanical axis. The second were outside this range. These two groups were then correlated to clinical outcome. Our results suggest that accurate reproduction of the mechanical axis improves clinical outcome and survi-vorship of the implant. Our data would support the use of intra operative computer navigation systems