Advertisement for orthosearch.org.uk
Results 1 - 20 of 44
Results per page:
Bone & Joint Research
Vol. 14, Issue 2 | Pages 143 - 154
25 Feb 2025
Bühler D Hilpert M Barbero A Müller AM Müller SA Martin I Pelttari K

Aims. Our aim was to investigate occurrence of senescent cells directly in tendon tissue biopsies from patients with chronic shoulder tendinopathies, and to correlate senescence with Enhancer of zeste 2 (EZH2) expression, the functional subunit of the epigenetic master regulator polycomb repressive complex. Methods. Human proximal long head of biceps tendons from patients with different chronic shoulder pathologies (n = 22), and controls from patients with humerus fracture (n = 6) and pathology (n = 4), were histologically scored for degeneration and analyzed for gene and protein expression of tendon specific factors, senescence markers, and EZH2. Tissues were further exposed to senotherapeutic compounds and the USA Food and Drugs Administration-approved selective EZH2 inhibitor EPZ-6438 and their senescence-associated secretory phenotype (SASP) assessed. Results. Expression of senescence markers (CDKN2A/p16, CDKN2D/p19) and EZH2 was significantly higher in tendinopathies compared to fracture or healthy tissue controls and positively correlated with the degree of tissue degeneration. Immunofluorescent stainings demonstrated colocalization of p16 and p19 with EZH2 in tenocytes. Treatment of tendon biopsies with EPZ-6438 reduced secretion of a panel of SASP factors, including interleukin-6 (IL6), IL8, matrix metalloproteinase-3 (MMP3) or GRO1, similarly to the senotherapeutic compound AG490. Conclusion. We demonstrate that senescence traits accumulate in pathological tendon tissues and positively correlate with tissue degeneration. Increased expression of CDKN2A/p16 and CDKN2D/p19 coincides with EZH2 expression, while its inhibition decreased the secretion of SASP factors, indicating a possible regulatory role of EZH2 in tenocyte senescence in tendinopathies. Reduction of cellular senescence, e.g. with EPZ-6438, opens ways to new potential therapeutic approaches for enhancing regeneration in chronic tendinopathies. Cite this article: Bone Joint Res 2025;14(2):143–154


Bone & Joint Open
Vol. 5, Issue 10 | Pages 944 - 952
25 Oct 2024
Deveza L El Amine MA Becker AS Nolan J Hwang S Hameed M Vaynrub M

Aims

Treatment of high-grade limb bone sarcoma that invades a joint requires en bloc extra-articular excision. MRI can demonstrate joint invasion but is frequently inconclusive, and its predictive value is unknown. We evaluated the diagnostic accuracy of direct and indirect radiological signs of intra-articular tumour extension and the performance characteristics of MRI findings of intra-articular tumour extension.

Methods

We performed a retrospective case-control study of patients who underwent extra-articular excision for sarcoma of the knee, hip, or shoulder from 1 June 2000 to 1 November 2020. Radiologists blinded to the pathology results evaluated preoperative MRI for three direct signs of joint invasion (capsular disruption, cortical breach, cartilage invasion) and indirect signs (e.g. joint effusion, synovial thickening). The discriminatory ability of MRI to detect intra-articular tumour extension was determined by receiver operating characteristic analysis.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1314 - 1320
1 Dec 2023
Broida SE Sullivan MH Barlow JD Morrey M Scorianz M Wagner ER Sanchez-Sotelo J Rose PS Houdek MT

Aims

The scapula is a rare site for a primary bone tumour. Only a small number of series have studied patient outcomes after treatment. Previous studies have shown a high rate of recurrence, with functional outcomes determined by the preservation of the glenohumeral joint and deltoid. The purpose of the current study was to report the outcome of patients who had undergone tumour resection that included the scapula.

Methods

We reviewed 61 patients (37 male, 24 female; mean age 42 years (SD 19)) who had undergone resection of the scapula. The most common resection was type 2 (n = 34) according to the Tikhoff-Linberg classification, or type S1A (n = 35) on the Enneking classification.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims

The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes.

Methods

This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group).


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 64 - 64
4 Apr 2023
Hartland A Islam R Teoh K Rashid M
Full Access

There remains much debate regarding the optimal method for surgical management of patients with long head of biceps pathology. The aim of this study was to compare the outcomes of tenotomy versus tenodesis.

This systematic review and meta-analysis was registered on PROSPERO (ref: CRD42020198658). Electronic databases searched included EMBASE, Medline, PsycINFO, and Cochrane Library. Randomized controlled trials (RCTs) comparing tenotomy versus tenodesis were included. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and the Jadad score. The primary outcome included patient reported functional outcome measures pooled using standardized mean difference (SMD) and a random effects model. Secondary outcome measures included pain (visual analogue scale VAS), rate of Popeye deformity, and operative time.

860 patients from 11 RCTs (426 tenotomy vs 434 tenodesis) were included in the meta-analysis. Pooled analysis of all PROMs data demonstrated comparable outcomes between tenotomy vs tenodesis (SMD 0.14, 95% CI −0.04 to 0.32; p=0.13). Sensitivity analysis comparing RCTs involving patients with and without an intact rotator cuff did not change the primary outcome. There was no significant difference for pain (VAS). Tenodesis resulted in a lower rate of Popeye deformity (OR 0.29, 95% CI 0.19 to 0.45, p < 0.00001). Tenotomy demonstrated a shorter operative time (MD 15.21, 95% CI 1.06 to 29.36, p < 0.00001).

Aside from a lower rate of cosmetic deformity, tenodesis yielded no measurable significant benefit to tenotomy for addressing pathology in the long head of biceps. A large multi-centre clinical effectiveness randomised controlled trial is needed to provide clarity in this area.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 35 - 35
4 Apr 2023
Teo B Yew A Tan M Chou S Lie D
Full Access

This study aims to compare the biomechanical properties of the “Double Lasso-Loop” suture anchor (DLSA) technique with the commonly performed interference screw (IS) technique in an ex vivo ovine model. Fourteen fresh sheep shoulder specimens were used in this study. Dissection was performed leaving only the biceps muscle attached to the humerus and proximal radius before sharply incised to simulate long head of biceps tendon (LHBT) tear. Repair of the LHBT tear was performed on all specimens using either DSLA or IS technique. Cyclical loading of 500 cycles followed by load to failure was performed on all specimens. Tendon displacement due to the cyclical loading at every 100 cycles as well as the maximum load at failure were recorded and analysed. Stiffness was also calculated from the load displacement graph during load to failure testing. No statistically significant difference in tendon displacement was observed from 200 to 500 cycles. Statistically significant higher stiffness was observed in IS when compared with DSLA (P = .005). Similarly, IS demonstrated significantly higher ultimate failure load as compared with DSLA (P = .001). Modes of failure observed for DSLA was mostly due to suture failure (7/8) and anchor pull-out (1/8) while IS resulted in mostly LHBT (4/6) or biceps (2/6) tears. DSLA failure load were compared with previous studies and similar results were noted. After cyclical loading, tendon displacement in DLSA technique was not significantly different from IS technique. Despite the higher failure loads associated with IS techniques in the present study, absolute peak load characteristics of DLSA were similar to previous studies. Hence, DLSA technique can be considered as a suitable alternative to IS fixation for biceps tenodesis


Bone & Joint 360
Vol. 11, Issue 6 | Pages 31 - 34
1 Dec 2022

The December 2022 Shoulder & Elbow Roundup360 looks at: Biceps tenotomy versus soft-tissue tenodesis in females aged 60 years and older with rotator cuff tears; Resistance training combined with corticosteroid injections or tendon needling in patients with lateral elbow tendinopathy; Two-year functional outcomes of completely displaced midshaft clavicle fractures in adolescents; Patients who undergo rotator cuff repair can safely return to driving at two weeks postoperatively; Are two plates better than one? A systematic review of dual plating for acute midshaft clavicle fractures; Treatment of acute distal biceps tendon ruptures; Rotator cuff tendinopathy: disability associated with depression rather than pathology severity; Coonrad-Morrey total elbow arthroplasty implications in young patients with post-traumatic sequelae.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1234 - 1241
1 Nov 2022
Park JH Park KT Kim SC Bukhary HA Lee SM Yoo JC

Aims

This study compared patients who underwent arthroscopic repair of large to massive rotator cuff tears (LMRCTs) with isolated incomplete repair of the tear and patients with incomplete repair with biceps tendon augmentation. We aimed to evaluate the additional benefit on clinical outcomes and the capacity to lower the re-tear rate.

Methods

We retrospectively reviewed 1,115 patients who underwent arthroscopic rotator cuff repair for full-thickness tears between October 2011 and May 2019. From this series, we identified 77 patients (28 male, 49 female) with a mean age of 64.1 years (50 to 80). Patients were classified into groups A (n = 47 incomplete) and B (n = 30 with biceps augmentation) according to the nature of their reconstruction. Clinical scores were checked preoperatively and at six months, one year, and two years postoperatively. In preoperative MRI, we measured the tear size, the degree of fatty infiltration, and muscle volume ratio of the supraspinatus. In postoperative MRI, the integrity of the repaired rotator cuff tendon was assessed using the Sugaya classification. Tendon thickness at the footprint was evaluated on T2-weighted oblique coronal view.


Bone & Joint 360
Vol. 11, Issue 5 | Pages 27 - 30
1 Oct 2022


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 394 - 400
1 Mar 2022
Lee KJ Kim YT Choi M Kim SH

Aims

The aim of this study was to compare the characteristics and outcomes of L-shaped and reverse L-shaped rotator cuff tears.

Methods

A total of 82 shoulders (81 patients) after arthroscopic rotator cuff repair were retrospectively enrolled. The mean age of the patients was 62 years (SD 6), 33 shoulders (40.2%) were in male patients, and 57 shoulders (69.5%) were the right shoulder. Of these, 36 shoulders had an L-shaped tear (group L) and 46 had a reverse L-shaped tear (group RL). Both groups were compared regarding characteristics, pre- and postoperative pain, and functional outcomes. Muscle status was assessed by preoperative MRI, and re-tear rates by postoperative ultrasonography or MRI.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 34 - 34
1 Mar 2021
MacDonald P Woodmass J McRae S Verhulst F Lapner P
Full Access

Management of the pathologic long-head biceps tendon remains controversial. Biceps tenotomy is a simple intervention but may result in visible deformity and subjective cramping. Comparatively, biceps tenodesis is technically challenging, and has increased operative times, and a more prolonged recovery. The purpose of this study was to determine the incidence of popeye deformity following biceps tenotomy versus tenodesis, identify predictors for developing a deformity, and compare subjective and objective outcomes between those that have one and those that do not. Data for this study were collected as part of a randomized clinical trial comparing tenodesis versus tenotomy in the treatment of lesions of the long head of biceps tendon. Patients 18 years of age or older with an arthroscopy confirmed biceps lesion were randomized to one of these two techniques. The primary outcome measure for this sub-study was the rate of a popeye deformity at 24-months post-operative as determined by an evaluator blinded to group allocation. Secondary outcomes were patient reported presence/absence of a popeye deformity, satisfaction with the appearance of their arm, as well as pain and cramping on a VAS. Isometric elbow flexion and supination strength were also measured. Interrater reliability (Cohen's kappa) was calculated between patient and evaluator on the presence of a deformity, and logistic regression was used to identify predictors of its occurrence. Linear regression was performed to identify if age, gender, or BMI were predictive of satisfaction in appearance if a deformity was present. Fifty-six participants were randomly assigned to each group of which 42 in the tenodesis group and 45 in the tenotomy group completed a 24-month follow-up. The incidence of popeye deformity was 9.5% (4/42) in the tenodesis group and 33% (15/45) in the tenotomy group (18 male, 1 female) with a relative risk of 3.5 (p=0.016). There was strong interrater agreement between evaluator and patient perceived deformity (kappa=0.636; p<0.001). Gender tended towards being a significant predictor of having a popeye with males having 6.6 greater odds (p=0.090). BMI also tended towards significance with lower BMI predictive of popeye deformity (OR 1.21; p=0.051). Age was not predictive (p=0.191). Mean (SD) satisfaction score regarding the appearance of their popeye deformity was 7.3 (2.6). Age was a significant predictor, with lower age associated with decreased satisfaction (F=14.951, adjusted r2=0.582, p=0.004), but there was no association with gender (p=0.083) or BMI (p=0.949). There were no differences in pain, cramping, or strength between those who had a popeye deformity and those who did not. The risk of developing a popeye deformity was 3.5 times higher after tenotomy compared to tenodesis. Male gender and lower BMI tended towards being predictive of having a deformity; however, those with a high BMI may have had popeye deformities that were not as visually apparent to an examiner as those with a lower BMI. Younger patients were significantly less satisfied with a deformity despite no difference in functional outcomes at 24 months. Thus, biceps tenodesis may be favored in younger patients with low BMI to mitigate the risk of an unsatisfactory popeye deformity


Bone & Joint Open
Vol. 2, Issue 1 | Pages 58 - 65
22 Jan 2021
Karssiens TJ Gill JR Sunil Kumar KH Sjolin SU

Aims

The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis.

Methods

From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1194 - 1199
14 Sep 2020
Lee H Kim E Kim Y

Aims

The purpose of this study was to identify the changes in untreated long head of the biceps brachii tendon (LHBT) after a rotator cuff tear and to evaluate the factors related to the changes.

Methods

A cohort of 162 patients who underwent isolated supraspinatus with the preservation of LHBT was enrolled and evaluated. The cross-sectional area (CSA) of the LHBT on MRI was measured in the bicipital groove, and preoperative to postoperative difference was calculated at least 12 months postoperatively. Second, postoperative changes in the LHBT including intratendinous signal change, rupture, dislocation, or superior labral lesions were evaluated with seeking of factors that were correlated with the changes or newly developed lesions after rotator cuff repair.


Bone & Joint Research
Vol. 8, Issue 9 | Pages 414 - 424
2 Sep 2019
Schmalzl J Plumhoff P Gilbert F Gohlke F Konrads C Brunner U Jakob F Ebert R Steinert AF

Objectives. The long head of the biceps (LHB) is often resected in shoulder surgery and could therefore serve as a cell source for tissue engineering approaches in the shoulder. However, whether it represents a suitable cell source for regenerative approaches, both in the inflamed and non-inflamed states, remains unclear. In the present study, inflamed and native human LHBs were comparatively characterized for features of regeneration. Methods. In total, 22 resected LHB tendons were classified into inflamed samples (n = 11) and non-inflamed samples (n = 11). Proliferation potential and specific marker gene expression of primary LHB-derived cell cultures were analyzed. Multipotentiality, including osteogenic, adipogenic, chondrogenic, and tenogenic differentiation potential of both groups were compared under respective lineage-specific culture conditions. Results. Inflammation does not seem to affect the proliferation rate of the isolated tendon-derived stem cells (TDSCs) and the tenogenic marker gene expression. Cells from both groups showed an equivalent osteogenic, adipogenic, chondrogenic and tenogenic differentiation potential in histology and real-time polymerase chain reaction (RT-PCR) analysis. Conclusion. These results suggest that the LHB tendon might be a suitable cell source for regenerative approaches, both in inflamed and non-inflamed states. The LHB with and without tendinitis has been characterized as a novel source of TDSCs, which might facilitate treatment of degeneration and induction of regeneration in shoulder surgery. Cite this article: J. Schmalzl, P. Plumhoff, F. Gilbert, F. Gohlke, C. Konrads, U. Brunner, F. Jakob, R. Ebert, A. F. Steinert. Tendon-derived stem cells from the long head of the biceps tendon: Inflammation does not affect the regenerative potential. Bone Joint Res 2019;8:414–424. DOI: 10.1302/2046-3758.89.BJR-2018-0214.R2


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 83 - 83
1 Nov 2016
Saithna A Longo A Leiter J MacDonald P Old J
Full Access

Recent literature has demonstrated that conventional arthroscopic techniques do not adequately visualise areas of predilection of pathology of the long head of biceps (LHB) tendon and are associated with a 30–50% rate of missed diagnoses. The aim of this study was to evaluate the safety, effectiveness and ease of performing biceps tenoscopy as a novel strategy for reducing the rate of missed diagnoses. Five forequarter amputation cadaver specimens were studied. The pressure in the anterior compartment was measured before and after surgical evaluation. Diagnostic glenohumeral arthroscopy was performed and the biceps tendon was tagged to mark the maximum length visualised by pulling the tendon into the joint. Biceps tenoscopy was performed using 3 different techniques (1. Flexible video-endoscopy, 2. Standard arthroscopy via Neviaser portal. 3. Standard arthroscope via antero-superior portal with retrograde instrumentation). Each was assessed for safety, ease of the procedure and whether the full length of the extra-articular part of the LHB tendon could be visualised. The t-test was used to compare the length of the LHB tendon visualised at standard glenohumeral arthroscopy vs that visualised at biceps tenoscopy. An open dissection was performed after the arthroscopic procedures to evaluate for an iatrogenic injury to local structures. Biceps tenoscopy allowed visualisation to the musculotendinous junction in all cases. The mean length of the tendon visualised was therefore significantly greater at biceps tenoscopy (104 mm) than at standard glenohumeral arthroscopy (33 mm) (mean difference 71 mm, p<0.0001). Biceps tenoscopy was safe with regards to compartment syndrome and there was no difference between pre- and post-operative pressure measurements (mean difference 0 mmHg, p=1). No iatrogenic injuries were identified at open dissection. Biceps tenoscopy allows excellent visualisation of the entire length of the LHB tendon and therefore has the potential to reduce the rate of missed diagnoses. This study did not demonstrate any risk of iatrogenic injury to important local structures or any risk of compartment syndrome. Clinical evaluation is required to further validate this technique


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 5 - 5
1 Nov 2016
Galatz L
Full Access

Total shoulder arthroplasty is becoming increasingly common. A biceps tenodesis or tenotomy has become a routine part of the operation. There are several advantages to a tenodesis or tenotomy. First, the long head of the biceps tendon is routinely pathologic. One study has shown that there are differences in gene expression and mechanical properties in the long head of the biceps tendon in the setting of glenohumeral joint arthritis. Clinically, we often see inflammation, tearing, adhesions, or other pathology. Second, it is largely accepted that the long head of the biceps tendon has minimal function at the shoulder. The biceps muscle primarily functions at the elbow. Therefore, there is little downside to performing a tenodesis if there is a chance of it generating pain after surgery. Another major reason to perform a tenodesis or a tenotomy is that the technique of total shoulder arthroplasty requires a subscapularis takedown or lesser tuberosity osteotomy. The ligaments and tendon associated with the subscapularis contribute to the stability of the biceps tendon and after subscapularis takedown, it is unlikely that the tendon would remain reduced in the groove. In addition, it is part of a technique to incise and release the rotator interval, additionally creating scarring and/or instability associated with the biceps tendon. Given those reasons, this is a very common and reasonable routine part of the procedure of total shoulder arthroplasty


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 80 - 80
1 Nov 2016
Saithna A Longo A Leiter J MacDonald P Old J
Full Access

The majority of studies reporting sensitivity and specificity data for imaging modalities and physical examination tests for long head of biceps (LHB) tendon pathology use arthroscopy as the gold standard. However, there is little published data to validate this as an appropriate benchmark. The aim of this study was to determine the maximum length of the LHB tendon that can be seen at glenohumeral arthroscopy and whether it allows adequate visualisation of common sites of pathology. Seven female cadaveric specimens were studied. Mean age was 74 years (range 44–96 years). Each specimen underwent arthroscopy in lateral decubitus (LD) and beach chair (BC) positions. The LBH-tendon was tagged with a suture placed with a spinal needle marking the intra-articular length and the maximum excursions achieved using a hook and a grasper in both LD and BC positions. T-tests were used to compare data. The mean intra-articular and extra-articular lengths of the tendon were 23.9 mm and 82.3 mm respectively. The mean length of tendon that could be visualised by pulling it into the joint with a hook was significantly less than with a grasper (LD: hook 29.9 mm, grasper 33.9 mm, mean difference 4 mm, p=0.0032. BC: hook 32.7 mm, grasper 37.6 mm, mean difference 4.9 mm, p=0.0001). Using the BC position allowed visualisation of a significantly greater length than the LD position when using either a hook (mean difference 2.86 mm, p=0.0327) or a grasper (mean difference 3.7 mm, p=0.0077). The mean length of the extra-articular part of the tendon visualised using a hook was 6 mm in LD and 8.9 mm in BC. The maximum length of the extra-articular portion visualised using this technique was 14 mm (17%). Pulling the tendon into the joint with a hook does not allow adequate visualisation of common distal sites of pathology in either LD or BC. Although the BC position allows a significantly greater proportion of the tendon to be visualised this represents a numerically small value and is not likely to be clinically significant. The use of a grasper also allowed greater excursion but results in iatrogenic tendon injury which precludes its use. The reported incidence of pathology in Denard zone C (distal to subscapularis) is 80% and in our study it was not possible to evaluate this zone even by using a grasper or maximum manual force to increase excursion. This is consistent with the extremely high rate of missed diagnoses reported in the literature. Surgeons should be aware that the technique of pulling the LHB-tendon into the joint is inadequate for visualising distal pathology and results in a high rate of missed diagnoses. Furthermore, efforts to achieve greater excursion by “optimum” limb positioning intra-operatively do not confer an important clinical advantage and are probably unnecessary


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 6 - 6
1 Nov 2016
Crosby L
Full Access

We know little regarding the long head of the biceps tendon's function but it is generally felt that it serves as a humeral head stabiliser by resisting superior migration during shoulder elevation. In total shoulder arthroplasty (TSA) the long head tendon is most commonly tenodesed as some have reported post-operative pain generated from an intact long head tendon. How does tenotomy or tenodesis of the long head tendon after TSA effect superior translation of the humeral head? We do not know the answer to this or if this increased tension causes any increase in subscapularis tendon failure. This will be presented as a possible reason to not remove the long head tendon of the biceps during TSA


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 14 - 14
1 Nov 2015
Romeo A
Full Access

Total shoulder arthroplasty (TSA) and reverse shoulder arthroplasty (RSA) are excellent surgical options for individuals with shoulder arthritis, providing good to excellent results in the vast majority of patients. Complications are rare, but can be devastating for both the patient and surgeon. An uncommon, but extremely problematic complication following shoulder arthroplasty is shoulder stiffness. While substantial literature discussing post-arthroplasty stiffness is available for other joints such as the hip, knee, and elbow, there is a paucity of research available discussing this complication in the shoulder. As noted in multiple reviews, diminished range of motion following TSA or RSA may be due to a number of factors, including pre-operative diagnosis of proximal humerus fracture, inadequate post-operative rehabilitation, implant-related factors such as malpositioning and/or inappropriate-sized implants, and heterotopic ossification. Often, pathology leading to post-arthroplasty stiffness involves scarring of the long head of the biceps tendon, rotator cuff impingement, as well as cuff tendonitis. Periprosthetic joint infection (PJI) is also important to recognise, and may be difficult to diagnose, especially in cases of Propionibacterium acnes infections. Importantly, PJI may present with stiffness as well as instability, and thus a high index of suspicion with a low threshold to aspirate is necessary in these challenging patients. Treatment of patients with stiffness following arthroplasty is challenging, and may involve arthroscopic intervention with or without manipulation, as well as manipulation under anesthesia alone. This paper will discuss the etiology, work-up, and treatment of patients with shoulder stiffness following TSA and RSA


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_12 | Pages 21 - 21
1 Jul 2014
Romeo A
Full Access

The functional importance of the long head of biceps tendon remains controversial, but it is well accepted as an important source of anterior shoulder pain. Both biceps tenotomy and tenodesis have well-documented results in the native shoulder. Management of the long head of biceps tendon during shoulder arthroplasty remains controversial. The existing literature supports surgical treatment of the biceps during shoulder arthroplasty. Walch et al. reported the largest series in multicenter study of over eight hundred shoulder arthroplasty patients with or without biceps tenodesis. The authors found more reproducible pain relief with biceps tenodesis and no difference in range of motion. Similarly, Soliman et al. reported on a prospective review of 37 patients undergoing hemiarthroplasty for fracture randomly assigned to biceps tenodesis vs. no treatment. The authors found a statistically significant improvement in Constant score and shoulder pain with biceps tenodesis. If left untreated during shoulder arthroplasty, the intact biceps tendon may be a source of anterior shoulder pain requiring revision surgery. Tuckman et al. reported excellent pain relief after biceps tenotomy or tenodesis for biceps-related pain after previous shoulder arthroplasty. The decision to perform a biceps tenotomy versus a tenodesis during shoulder arthroplasty also remains controversial. Tenotomy may increase the risk of cosmetic pop-eye deformity and muscle cramping or fatigue over tenodesis. Therefore, routine long head of biceps soft tissue tenodesis is recommended during shoulder arthroplasty as it safe, reproducible, cost-effective, associated with improved outcome scores, and minimises the risk of cosmetic deformity and pain associated with biceps tenotomy