Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 868 - 873
1 Jul 2013
Cho SK Lu Y Lee D

Dysphagia is a common complication of anterior surgery of the cervical spine. The incidence of post-operative dysphagia may be as high as 71% within the first two weeks after surgery, but gradually decreases during the following months. However, 12% to 14% of patients may have some persistent dysphagia one year after the procedure. It has been shown that female gender, advanced age, multilevel surgery, longer operating time and severe pre-operative neck pain may be risk factors. Although the aetiology remains unclear and is probably multifactorial, proposed causes include oesophageal retraction, prominence of the cervical plate and prevertebral swelling. Recently, pre-operative tracheal traction exercises and the use of retropharyngeal steroids have been proposed as methods of reducing post-operative dysphagia.

We performed a systematic review to assess the incidence, aetiology, risk factors, methods of assessment and management of dysphagia following anterior cervical spinal surgery.

Cite this article: Bone Joint J 2013;95-B:868–73.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 543 - 547
1 Apr 2013
Qi M Chen H Liu Y Zhang Y Liang L Yuan W

In a retrospective cohort study we compared the clinical outcome and complications, including dysphagia, following anterior cervical fusion for the treatment of cervical spondylosis using either a zero-profile (Zero-P; Synthes) implant or an anterior cervical plate and cage. A total of 83 patients underwent fusion using a Zero-P and 107 patients underwent fusion using a plate and cage. The mean follow-up was 18.6 months (. sd. 4.2) in the Zero-P group and 19.3 months (. sd. 4.1) in the plate and cage group. All patients in both groups had significant symptomatic and neurological improvement. There were no significant differences between the groups in the Neck Disability Index (NDI) and visual analogue scores at final follow-up. The cervical alignment improved in both groups. There was a higher incidence of dysphagia in the plate and cage group on the day after surgery and at two months post-operatively. All patients achieved fusion and no graft migration or nonunion was observed. When compared with the traditional anterior cervical plate and cage, the Zero-P implant is a safe and convenient procedure giving good results in patients with symptomatic cervical spondylosis with a reduced incidence of dysphagia post-operatively. Cite this article: Bone Joint J 2013;95-B:543–7


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 83 - 83
1 Jun 2012
Balamurali G Konig M Boszczyk B
Full Access

Aim. A retrospective review of the management of adjacent level discectomy and fusion using a Zero-P (Synthes) cage and report of ease of technique and outcomes. Method. Surgical approach to adjacent level cervical disc protrusion with previous anterior cervical discectomy and fusion (ACDF) can be difficult. We review 4 patients who had previous ACDF with cage and plate who developed new onset adjacent level cervical disc prolepses causing myelopathy. A retrospective review of demographic data, symptoms, details of surgery, pre and post operative radiology, pre and postoperative ODI and pain score, length of stay, complications and follow-up data were collected in all patients. Results. Previous ACDF with plate was performed in all 4 patients an average of 11.6 years ago. Two patients had bilateral approaches previously and both had previous vascular injuries. The average duration of current symptoms was 9 months with a mean age of 65 years. All patients presented with myelopathy and two also had radiculopathy. Multiple level ACDF were operated in 2 patients previously. Revision surgery and dissection on the disc level was restricted by the previous plate. Screws from the previous plate fusion were removed adjacent to the level of surgery and discectomy was performed using distractor pins through the screw sites. Following discectomy a Zero-P cage was used to fusion with DBX under image intensifier guidance. The advantage was not to remove the previous plate and keep the dissection over the scar tissue to the minimal. All patients improved in their radicular symptoms with improvement of their hand function in the myelopaths. There was no complication and post operative radiographs were satisfactory. Conclusions. Use of the Zero-P cage for adjacent level discectomy and fusion was safe without disturbing the previous cage and plate fusion or stability