The aim of this study was to determine the risk of tibial eminence avulsion intraoperatively for bi-unicondylar knee arthroplasty (Bi-UKA), with consideration of the effect of implant positioning, overstuffing, and sex, compared to the risk for isolated medial unicondylar knee arthroplasty (UKA-M) and bicruciate-retaining total knee arthroplasty (BCR-TKA). Two experimentally validated finite element models of tibia were implanted with UKA-M, Bi-UKA, and BCR-TKA. Intraoperative loads were applied through the condyles, anterior cruciate ligament (ACL), medial collateral ligament (MCL), and lateral collateral ligament (LCL), and the risk of fracture (ROF) was evaluated in the spine as the ratio of the 95th percentile maximum principal elastic strains over the tensile yield strain of proximal tibial bone.Aims
Methods
Introduction. The purpose of this study was to characterize the recovery of physical activity following knee arthroplasty by means of step counts and flight counts (flights of stairs) measured using a smartphone-based care platform. Methods. This is a secondary data analysis on the treatment cohort of a multicenter prospective trial evaluating the use of a smartphone-based care platform for primary total and
Osteonecrosis (ON) can cause considerable morbidity in young people who undergo treatment for acute lymphoblastic leukaemia (ALL). The aims of this study were to determine the operations undertaken for ON in this population in the UK, along with the timing of these operations and any sequential procedures that are used in different joints. We also explored the outcomes of those patients treated by core decompression (CD), and compared this with conservative management, in both the pre- or post-collapse stages of ON. UK treatment centres were contacted to obtain details regarding surgical interventions and long-term outcomes for patients who were treated for ALL and who developed ON in UKALL 2003 (the national leukaemia study which recruited patients aged 1 to 24 years at diagnosis of ALL between 2003 and 2011). Imaging of patients with ON affecting the femoral head was requested and was used to score all lesions, with subsequent imaging used to determine the final grade. Kaplan-Meier failure time plots were used to compare the use of CD with non surgical management.Aims
Methods
The objectives of this study were to compare postoperative pain, analgesia requirements, inpatient functional rehabilitation, time to hospital discharge, and complications in patients undergoing conventional jig-based unicompartmental knee arthroplasty (UKA) This prospective cohort study included 146 patients with symptomatic medial compartment knee osteoarthritis undergoing primary UKA performed by a single surgeon. This included 73 consecutive patients undergoing conventional jig-based mobile bearing UKA, followed by 73 consecutive patients receiving robotic-arm assisted fixed bearing UKA. All surgical procedures were performed using the standard medial parapatellar approach for UKA, and all patients underwent the same postoperative rehabilitation programme. Postoperative pain scores on the numerical rating scale and opiate analgesia consumption were recorded until discharge. Time to attainment of predefined functional rehabilitation outcomes, hospital discharge, and postoperative complications were recorded by independent observers.Aims
Patients and Methods
The role of high tibial osteotomy (HTO) is being questioned by
the use of unicompartmental knee arthroplasty (UKA) in the treatment
of medial compartment femorotibial osteoarthritis. Our aim was to
compare the outcomes of revision HTO or UKA to a total knee arthroplasty
(TKA) using computer-assisted surgery in matched groups of patients. We conducted a retrospective study to compare the clinical and
radiological outcome of patients who underwent revision of a HTO
to a TKA (group 1) with those who underwent revision of a medial
UKA to a TKA (group 2). All revision procedures were performed using
computer-assisted surgery. We extracted these groups of patients
from our database. They were matched by age, gender, body mass index,
follow-up and pre-operative functional score. The outcomes included
the Knee Society Scores (KSS), radiological outcomes and the rate
of further revision.Aims
Patients and Methods
A number of advantages of
Anatomical total knee arthroplasty alignment
Difficulties arise when counselling younger patients on the long-term sequelae of a minor knee chondral defect. This study assesses the natural history of patients with grade 2 Outerbridge chondral injuries of the medial femoral condyle at arthroscopy. We reviewed all arthroscopies performed by one surgeon over 12 years with Outerbridge grade 2 chondral defects. Patients aged 30 to 59 were included. Meniscal injuries found were treated with partial menisectomy. All patients had five-year follow up minimum. Primary outcome measure was further interventions of total or
We present detailed information about early morbidity
after aseptic revision knee replacement from a nationwide study.
All aseptic revision knee replacements undertaken between 1st October
2009 and 30th September 2011 were analysed using the Danish National
Patient Registry with additional information from the Danish Knee
Arthroplasty Registry. The 1218 revisions involving 1165 patients
were subdivided into total revisions, large partial revisions, partial
revisions and revisions of
Current analysis of unicondylar knee replacements
(UKRs) by national registries is based on the pooled results of medial
and lateral implants. Consequently, little is known about the differential
performance of medial and lateral replacements and the influence
of each implant type within these pooled analyses. Using data from
the National Joint Registry for England and Wales (NJR) we aimed
to determine the proportion of UKRs implanted on the lateral side
of the knee, and their survival and reason for failure compared
with medial UKRs. By combining information on the side of operation
with component details held on the NJR, we were able to determine
implant laterality (medial versus lateral) for
32 847 of the 35 624
Introduction. Kneeling ability is better in unicompartmental than total knee arthroplasty. There is also an impression that mobile bearing knees achieve better functional outcome than their fixed bearing cousins in unicompartmental and to a lesser extent total joint arthroplasty. In the UK, the market leading unicompartmental replacement is mobile bearing. Aim. To analyse kneeling ability after total and unicompartmental knee replacement using mobile and fixed bearing inserts. Methods. In our department there are two prospective randomised studies (fixed versus mobile) in this area. For total knee arthroplasty, 207 TKR patients receiving the same prosthesis (Rotaglide, Corin, UK) were randomised into mobile bearing (102 patients, mean age of 53 years) or fixed bearing (105 patients, mean age of 55 years). Regarding unicondylar knees, data was collected on 352 UKR patients who received the same implant (Uniglide - previously known as AMC - Corin, UK). Within this group there was a randomised controlled trial of fixed v mobile bearings: 52 patients (mean age 62 years) had a mobile insert and 57 (mean age 65 yrs) had a fixed insert. Data was also collected on patients undergoing fixed bearing lateral
Introduction. Bicompartmental osteoarthritis involving the medial tibiofemoral and the patellofemoral compartments is often treated with total knee replacement. Improved implants and surgical techniques have led to renewed interest in bicompartmental arthroplasty. This study evaluates the radiographic and early clinical results of bicompartmental arthroplasty with separate unlinked components implanted with the assistance of a robotic surgical arm. In addition, we examine the amount of bone resected using unlinked bicompartmental components compared to total knee replacement. Finally, a retrospective review of total knee cases examines the applicability of this early intervention procedure. Methods. 97 patients received simultaneous but geometrically separate medial tibiofemoral and patellofemoral arthroplasties with implants specifically designed to take advantage of a new bone and tissue sparing implantation technique using haptic robotics. These patients came from four surgeons at four different hospitals. The average follow-up was 9 months. Pre- and post-operative radiographs were taken. ROM, KSS and WOMAC scores were recorded. The patients had an average age of 67 yrs (range: 45-95), BMI of 29 ± 4kg/m. 2. 47% of the patients were male. We retrospectively reviewed pre and post operative notes from 406 consecutive TKA patients from a single surgeon. Intraoperative data included the integrity of the three compartments and the ACL. Results. At only six weeks follow-up, patients recovered their pre-operative ROM (p=0.37). Knee Society Knee scores (knee and function) and WOMAC scores (pain, function and total) significantly improved from pre-operative values at every follow-up of 6 weeks, 6 months and 1 year (p<0.05). Radiographically, there was no evidence of loosening, wear or progression of OA. There were also no perioperative complications. Using computer simulation, the amount of bone removed using bicompartmental arthroplasty compared to traditional TKA was predicted. Total bone removed on the femur and the tibia using a standard TKA implant is 3.5 times the bone removed using a bicompartmental onlay implant and 4 times the bone removed when using a bicompartmental inlay implant. In the review of 406 TKA cases, the ACL was intact in 66% of these cases. Based on these data alone, 16% of these TKA patients were indicated for a
Recently in the literature the indications of unicompartmental knee arthroplasty have been extended by the inclusion of patients with arthritis which is predominantly but not exclusively effecting the medial compartment. The aim of this study is to evaluate the outcome of MAKO
Purpose. To examine how patients viewed the outcome of their joint replacement at least one year post surgery. Emphasis was placed on investigating the relative influence of ongoing pain and functional limitation on patient satisfaction. Method. Questionnaire based assessment of the Oxford Knee Score (OKS), patient satisfaction, and need for reoperation in a group of 10,000 patients who had undergone primary unilateral knee replacement between April and December 2003. Questionnaires were linked to the NJR database to provide data on background demographics, clinical parameters and intraoperative surgical information for each patient. Data was analysed to investigate the relationship between the OKS, satisfaction rate and the background factors. Multivariable logistic regression was performed to establish which factors influenced patient satisfaction. Results. 87.4% patients returned questionnaires. Overall 81.8% indicated they were satisfied with their knee replacement, with 7.0% unsatisfied and 11.2% unsure. The mean OKS varied dependent upon patients' satisfaction (satisfied=22.0, unsatisfied=41.7, unsure=35.2). These differences were statistically significant (p<0.001). Regression modelling showed that patients with higher scores relating to the pain and function elements of the OKS had lower levels of satisfaction (p<0.001) and that ongoing pain was a stronger predictor of lower levels of satisfaction. Other predictors of lower levels of satisfaction included female gender (p<0.05), a primary diagnosis of osteoarthritis (p=0.02) and
We carried out a prospective investigation into
the radiological outcomes of uncemented Oxford medial compartment
unicondylar replacement in 220 consecutive patients (231 knees)
performed in a single centre with a minimum two-year follow-up.
The functional outcomes using the mean Oxford knee score and the
mean high-activity arthroplasty score were significantly improved
over the pre-operative scores (p <
0.001). There were 196 patients
with a two-year radiological examination performed under fluoroscopic
guidance, aiming to provide images acceptable for analysis of the
bone–implant interface. Of the six tibial zones examined on each
knee on the anteroposterior radiograph, only three had a partial
radiolucent line. All were in the medial aspect of the tibial base plate
(zone 1) and all measured <
1 mm. All of these patients were
asymptomatic. There were no radiolucent lines seen around the femoral
component or on the lateral view. There was one revision for loosening
at one year due to initial inadequate seating of the tibial component.
These results confirm that the early uncemented Oxford medial unicompartmental
compartmental knee replacements were reliable and the incidence
of radiolucent lines was significantly decreased compared with the
reported results of cemented versions of this implant. These independent
results confirm those of the designing centre.
Aim: Cementation of tibial implants in total knee arthroplasty is a gold-standard considering the high loosening rates of cementless implants. In contrast, only sparse data exist regarding
Background: In a recent publication from the National Joint Registry it was suggested that prosthesis type influenced patient satisfaction at one year following knee arthroplasty. In this report
Purpose: To examine how patients viewed the outcome of their joint replacement at least one year post surgery. Emphasis was placed on investigating the relative influence of ongoing pain and functional limitation on patient satisfaction. Method: Questionnaire based assessment of the Oxford Knee Score (OKS), patient satisfaction, and need for reoperation in a group of 10,000 patients who had undergone primary unilateral knee replacement between April and December 2003. Questionnaires were linked to the NJR database to provide data on background demographics, clinical parameters and intraoperative surgical information for each patient. Data was analysed to investigate the relationship between the OKS, satisfaction rate and the background factors. Multivariable logistic regression was performed to establish which factors influenced patient satisfaction. Results: 87.4% patients returned questionnaires. Overall 81.8% indicated they were satisfied with their knee replacement, with 7.0% unsatisfied and 11.2% unsure. The mean OKS varied dependent upon patients’ satisfaction (satisfied=22.04 (S.D 7.87), unsatisfied=41.70 (S.D 8.32), unsure=35.17 (S.D 8.24)). These differences were statistically significant (p<
0.001). Regression modelling showed that patients with higher scores relating to the pain and function elements of the OKS had lower levels of satisfaction (p<
0.001) and that ongoing pain was a stronger predictor of lower levels of satisfaction. Other predictors of lower levels of satisfaction included female gender (p<
0.05), a primary diagnosis of osteoarthritis (p=0.02) and
Purpose: A retrospective review was done to evaluate survival of