Aims. Unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) have both been shown to be effective treatments for osteoarthritis (OA) of the knee. Many studies have compared the outcomes of the two treatments, but less so with the use of robotics, or individualized
Introduction. The first VRAS TKA was performed in New Zealand in November 2020 using a Patient Specific Balanced Technique whereby VRAS enables very accurate collection of the bony anatomy and soft tissue envelope of the knee to plan and execute the optimal positioning for a balanced TKA. Method. The first 45 VRAS patients with idiopathic osteoarthritis of the knee was compared with 45 sequential patients who underwent the same
Aims. Aseptic loosening is the most common cause of failure following cemented total knee arthroplasty (TKA), and has been linked to poor cementation technique. We aimed to develop a consensus on the optimal technique for component cementation in TKA. Methods. A UK-based, three-round, online modified Delphi Expert Consensus Study was completed focusing on cementation
Abstract. Introduction. Mid-flexion instability may cause poor outcomes following
Orthopaedic surgeons are currently faced with an overwhelming number of choices surrounding total knee arthroplasty (TKA), not only with the latest technologies and prostheses, but also fundamental decisions on alignment philosophies. From ‘mechanical’ to ‘adjusted mechanical’ to ‘restricted kinematic’ to ‘unrestricted kinematic’ — and how constitutional alignment relates to these — there is potential for ambiguity when thinking about and discussing such concepts. This annotation summarizes the various alignment strategies currently employed in TKA. It provides a clear framework and consistent language that will assist surgeons to compare confidently and contrast the concepts, while also discussing the latest opinions about alignment in TKA. Finally, it provides suggestions for applying consistent nomenclature to future research, especially as we explore the implications of 3D alignment patterns on patient outcomes. Cite this article:
Unicompartmental knee arthroplasty (UKA) and bicompartmental knee arthroplasty (BCA) have been associated with improved functional outcomes compared to total knee arthroplasty (TKA) in suitable patients, although the reason is poorly understood. The aim of this study was to measure how the different arthroplasties affect knee extensor function. Extensor function was measured for 16 cadaveric knees and then retested following the different arthroplasties. Eight knees underwent medial UKA then BCA, then posterior-cruciate retaining TKA, and eight underwent the lateral equivalents then TKA. Extensor efficiency was calculated for ranges of knee flexion associated with common activities of daily living. Data were analyzed with repeated measures analysis of variance (α = 0.05).Aims
Methods
Vitamin E-infused highly cross-linked polyethylene (E1) has recently been introduced in total knee arthroplasty (TKA). An in vitro wear simulator study showed that E1 reduced polyethylene wear. However there is no published information regarding in vivo wear. Previous reports suggest that newly introduced materials which reduce in vitro polyethylene wear do not necessarily reduce in vivo polyethylene wear. To assist in the evaluation of the newly introduced material before widespread use, we established an in vivo polyethylene wear particle analysis for TKA. The aim of this study was to compare in vivo polyethylene wear particle generation between E1 and conventional polyethylene (ArCom) in TKA. A total of 34 knees undergoing TKA (17 each with ArCom or E1) were investigated. Except for the polyethylene insert material, the prostheses used for both groups were identical. Synovial fluid was obtained at a mean of 3.4 years (SD 1.3) postoperatively. The in vivo polyethylene wear particles were isolated from the synovial fluid using a previously validated method and examined by scanning electron microscopy.Aims
Methods
To compare time dependent functional improvement for patients with medial, respectively lateral knee osteoarthritis (OA) after treatment with opening wedge osteotomy relieving the pressure on the osteoarthritic part of the knee. In all, 49 patients (52 knees) with a mean age of 47 years (31 to 64) underwent high tibial osteotomies (HTO), and 24 patients with a mean age of 48 years (31 to 62) low femoral osteotomies (LFO) with opening wedge technique due to medial, respectively lateral knee OA with malalignment. All osteotomies were stabilized with a Puddu plate and bone grafting performed in the same time period (2000 to 2008). The patients were evaluated by the Knee Injury and Osteoarthritis Outcome Score (KOOS) pre-operatively and at six months, and at one, two, five, and ten years postoperatively. The knee OA was graded according to the Ahlbäck and Kellgren-Lawrence radiological scoring systems.Aims
Methods
An algorithm to determine the constitutional alignment of the lower limb once arthritic deformity has occurred would be of value when undertaking kinematically aligned total knee arthroplasty (TKA). The purpose of this study was to determine if the arithmetic hip-knee-ankle angle (aHKA) algorithm could estimate the constitutional alignment of the lower limb following development of significant arthritis. A matched-pairs radiological study was undertaken comparing the aHKA of an osteoarthritic knee (aHKA-OA) with the mechanical HKA of the contralateral normal knee (mHKA-N). Patients with Grade 3 or 4 Kellgren-Lawrence tibiofemoral osteoarthritis in an arthritic knee undergoing TKA and Grade 0 or 1 osteoarthritis in the contralateral normal knee were included. The aHKA algorithm subtracts the lateral distal femoral angle (LDFA) from the medial proximal tibial angle (MPTA) measured on standing long leg radiographs. The primary outcome was the mean of the paired differences in the aHKA-OA and mHKA-N. Secondary outcomes included comparison of sex-based differences and capacity of the aHKA to determine the constitutional alignment based on degree of deformity.Aims
Methods
Metaphyseal cones with cemented stems are frequently used in revision total knee arthroplasty (TKA). However, if the diaphysis has been previously violated, the resultant sclerotic canal can impair cemented stem fixation, which is vital for bone ingrowth into the cone, and long-term fixation. We report the outcomes of our solution to this problem, in which impaction grafting and a cemented stem in the diaphysis is combined with an uncemented metaphyseal cone, for revision TKA in patients with severely compromised bone. A metaphyseal cone was combined with diaphyseal impaction grafting and cemented stems for 35 revision TKAs. There were two patients with follow-up of less than two years who were excluded, leaving 33 procedures in 32 patients in the study. The mean age of the patients at the time of revision TKA was 67 years (32 to 87); 20 (60%) were male. Patients had undergone a mean of four (1 to 13) previous knee arthroplasty procedures. The indications for revision were aseptic loosening (80%) and two-stage reimplantation for prosthetic joint infection (PJI; 20%). The mean follow-up was four years (2 to 11).Aims
Methods
Introduction. Robotics have been applied to total knee arthroplasty (TKA) to improve surgical precision in components’ placement, providing a physiologic ligament tensioning throughout knee range of motion. The purpose of the present study is to evaluate femoral and tibial components’ positioning in robotic-assisted TKA after fine-tuning according to soft tissue tensioning, aiming symmetric and balanced medial and lateral gaps in flexion/extension. Materials and Methods. Forty-three consecutive patients undergoing robotic-assisted TKA between November 2017 and November 2018 were included. Pre-operative radiographs were performed and measured according to Paley's. The tibial and femoral cuts were performed based on the individual intra-operative fine-tuning, checking for components’ size and placement, aiming symmetric medial and lateral gaps in flexion/extension. Cuts were adapted to radiographic epiphyseal anatomy and respecting ±2° boundaries from neutral coronal alignment. Robotic data were recorded, collecting information relative to medial and lateral gaps in flexion and extension. Results. Patients were divided based on the pre-operative coronal mechanical femoro-tibial angle (mFTA). Only knees with varus deformity (mFTA<178°), 29 cases, were taken into account. On average, the tibial component was placed at 1.2°±0.5 varus. Femoral component fine-tuning based on soft-tissues tensioning in extension and flexion determined the following alignments: 0.2°±1.2 varus on the coronal plane and 1.2°±2.2° external rotation with respect to the trans-epicondylar axis (TEA) as measured on the CT scan in the horizontal plane. The average gaps after femoral and tibial resections, resulted as follows: 19.5±0.8 mm on the medial side in extension, 20.0±0.9 mm on the lateral side in extension, 19.1±0.7 mm on the medial side in flexion and 19.5±0.7 mm on the lateral side in flexion. On average, the post-implant coronal alignment as reported by the robotic system resulted 2.0°±1.5 varus. Discussion. The proposed robotic-arm assisted
Introduction. Robotic-assisted total knee arthroplasty (TKA) was introduced to improve limb alignment, component positioning, and soft-tissue balance, yet the effect of adoption of this technology has not been established. This study was designed to evaluate whether robotic-assisted TKA leads to improved patient reported outcome measures (PROMs) and patient satisfaction as compared to conventional TKA at 3 and 12 months. Methods. This IRB-approved single-surgeon retrospective cohort analysis of prospectively collected data compared 113 conventional TKA patients with 145 imageless robotic-assisted TKA patients (Navio™ Surgical System, Smith&Nephew®, Memphis TN). Basic demographic information, intraoperative and postoperative data, and PROMs (SF-P, SF-M, WOMAC pain, WOMAC stiffness, WOMAC Physical Function, KSS) were collected and recorded preoperatively, at 3 months, and at 12 months following surgery. Range of motion (ROM), blood loss, surgical duration, and complication rates between groups were also collected. Continuous measures such as mean difference in PROMs and ROM were compared using unpaired t-tests. Categorical measures such as the percentage of patients with complications were compared using chi-square analysis. Results. There were no baseline demographic differences or preoperative PROMs between groups. Following TKA, there were no differences between groups with respect to ROM or any of the PROMs (SF-P, SF-M, WOMAC pain, WOMAC stiffness, WOMAC Physical Function, and KS scores) at 3- or 12-months. Difference between the group included larger EBL(242 vs 209 mL, p<.001) and longer surgical duration (119 vs 107minutes, p<.001) for robotic-assisted surgery. There were no differences between the two groups in total post operative complications however subgroup analysis demonstrated that the robotic assisted cohort had fewer periprosthetic joint infections (1 vs 3, p=.048) and total reoperations (1 vs 7, p=.0114). Conclusions. Imageless robotic-assisted TKA resulted in similar function and satisfaction scores when compared to conventional TKA at 3 and 12 months. While EBL and surgical duration were greater with robotic-assisted
This aim of this study was to assess the feasibility of designing and introducing generic 3D-printed instrumentation for routine use in total knee arthroplasty. Instruments were designed to take advantage of 3D-printing technology, particularly ensuring that all parts were pre-assembled, to theoretically reduce the time and skill required during surgery. Concerning functionality, ranges of resection angle and distance were restricted within a safe zone, while accommodating either mechanical or anatomical alignment goals. To identify the most suitable biocompatible materials, typical instrument shapes and mating parts, such as dovetails and screws, were designed and produced.Aims
Materials and Methods
Background. Total knee arthroplasty (TKA) is an effective surgical procedure to alleviate excruciating pain and correct dysfunction due to severe knee deformity. The satisfaction rate with current TKA is 80%, While 20% of the patients report uncomfortable feeling during stair descending and deeply knee bending. Preserving the ligaments might allow a restoration close to the natural function, although sacrifice of the ACL is common with the conventional
Introduction: I always aim for neutral mechanical axis alignment. My principles of a successful TKA are proper alignment in all 3 planes, soft tissue balance in extension first, flexion gap balancing by parallel to tibial cut technique, maintenance of joint line, correct sizing of femoral component, and proper cement fixation. Long-term Survivorship: There is long-term data that supports the efficacy and durability of the neutral position of the proximal tibial cut. Over a 20-year follow-up there was a 92.6% success rate in my study. Other authors have found similarly successful survivorship for mechanical failure. Balance
Introduction. Design evolution of total knee arthroplasty (TKA) has improved implant durability and clinical outcomes. However, it has been reported that some patients have limited satisfaction with their operated knees [1]. In view of better patient satisfaction, there have been growing interests in anatomically aligned TKA. The anatomically aligned
Introduction: I always aim for neutral mechanical axis alignment. My principles of a successful TKA are proper alignment in all 3 planes, soft tissue balance in extension first, flexion gap balancing by parallel to tibial cut technique, maintenance of joint line, correct sizing of femoral component, and proper cement fixation. Long-term Survivorship: There is long-term data that supports the efficacy and durability of the neutral position of proximal tibial cut. Over a 20-year follow-up there was a 92.6% success rate in my study. Other authors have found similarly successful survivorship for mechanical failure. Balance