Advertisement for orthosearch.org.uk
Results 1 - 16 of 16
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_14 | Pages 15 - 15
23 Jul 2024
Hossain T Kimberley C Starks I Barlow T Barlow D
Full Access

Malalignment is a common complication following tibial surgery, occurring in 10% of fractures. This is associated with prolonged healing time and non-union. It occurs due to inability to maintain a satisfactory reduction. A reduction device, such as the Staffordshire Orthopaedic Reduction Machine (STORM), permits the surgeon to manipulate the fracture and hold it reduced. A retrospective parallel case series was undertaken of all patients undergoing tibial nails over a six-year period from 2014 to 2021. Patient demographics were obtained from medical records. Operative times obtained from the theatre IT system and included the time patient entered theatre and surgical start and finish times for each case. Anteroposterior and lateral long leg post-operative radiographs were reviewed. Angulation was measured in both coronal and sagittal planes, by two separate orthopaedic surgeons. A reduction was classified to be ‘mal-aligned’ if the angle measured was greater than 5 degrees. One tailed unpaired t-test was used to compare alignment in each plane. Bony union was assessed on subsequent radiographs and was determined according to the Radiographic Union Score for Tibial Fractures. 31 patients underwent tibial nail during the time period. 8 patients were lost to follow up and were excluded. Of the remaining 23 patients, the STORM device was utilised in 11. The overall mean alignment was acceptable across all groups at 2.17° in the coronal plane and 2.56° in the saggital plane. Analysing each group individually demonstrated an improved alignment when STORM was utilised: 1.7° (1°–3°) vs 2.54° (0°–5°) for the coronal plane and 1.6° (0°–3°) vs 3.31° (0°–9°) in the saggital plane. This difference was significant in saggital alignment (p=0.03) and showed a positive trend in coronal alignment, although was not significant (p=0.08). The time in theatre was shorter in the control group with a mean of 113 minutes (65 to 219) in comparison to STORM with a mean of 140 minutes (105 to 180), an increased theatre time of 27 minutes (p=0.04). This study demonstrates that STORM can be used in the surgical treatment of tibial fractures resulting in improved fracture alignment with a modest increase in theatre time


Bone & Joint Research
Vol. 13, Issue 5 | Pages 226 - 236
9 May 2024
Jürgens-Lahnstein JH Petersen ET Rytter S Madsen F Søballe K Stilling M

Aims

Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear.

Methods

A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 52 - 52
17 Nov 2023
Jones R Bowd J Gilbert S Wilson C Whatling G Jonkers I Holt C Mason D
Full Access

Abstract. OBJECTIVE. Knee varus malalignment increases medial knee compartment loading and is associated with knee osteoarthritis (OA) progression and severity. 1. Altered biomechanical loading and dysregulation of joint tissue biology drive OA progression, but mechanistic links between these factors are lacking. Subchondral bone structural changes are biomechanically driven, involve bone resorption, immune cell influx, angiogenesis, and sensory nerve invasion, and contribute to joint destruction and pain. 2. We have investigated mechanisms underlying this involving RANKL and alkaline phosphatase (ALP), which reflect bone resorption and mineralisation respectively. 3. and the axonal guidance factor Sema3A. Sema3A is osteotropic, expressed by mechanically sensitive osteocytes, and an inhibitor of sensory nerve, blood vessel and immune cell invasion. 4. Sema3A is also differentially expressed in human OA bone. 5. HYPOTHESIS: Medial knee compartment overloading in varus knee malalignment patients causes dysregulation of bone derived Sema3A signalling directly linking joint biomechanics to pathology and pain. METHODS. Synovial fluid obtained from 30 subjects with medial knee OA (KL grade II-IV) undergoing high tibial osteotomy surgery (HTO) was analysed by mesoscale discovery and ELISA analysis for inflammatory, neural and bone turnover markers. 11 of these patients had been previously analysed in a published patient-specific musculoskeletal model. 6. of gait estimating joint contact location, pressure, forces, and medial-lateral condyle load distribution in a published data set included in analyses. Data analysis was performed using Pearson's correlation matrices and principal component analyses. Principal Components (PCs) with eigenvalues greater than 1 were analysed. RESULTS. PC1 (32.94% of variation) and PC2 (25.79% of variation) from PCA analysis and correlation matrices separated patients according to correlated clusters of established inflammatory markers of OA pain and progression (IL6/IL8, r=0.754, p<0.001) and anti-inflammatory mediators (IL4/IL10, r=0.469, p=0.005). Bone turnover marker ALP was positively associated with KL grade (r=0.815, p=0.002) and negatively associated with IL10 (r=−0.402, p=0.018) and first peak knee loading pressures (r=−0.688, p=0.019). RANKL was positively associated with IL4 (r=0.489, p=0.003). Synovial fluid Sema3A concentrations showed separate clustering from all OA progression markers and was inversely correlated with TNF-α (r=−0.423, p=0.022) in HTO patients. Sema3A was significantly inversely correlated with total predicted force in the medial joint compartment (r=−0.621, p=0.041), mean (r=−0.63, p=0.038) and maximum (r=−0.613, p=0.045) calculated medial compartment joint pressures during the first phase and mean (r=−0.618, p=0.043) and maximum (r=−0.641, p=0.034) medial compartment joint pressures during midstance outputs of patient-specific musculoskeletal model. CONCLUSIONS. This study shows joint inflammatory status and mechanical overloading influence subchondral bone-remodelling. Synovial Sema3A concentrations are inversely correlated to patient-specific musculoskeletal model estimations of pathological medial overloading. This study reveals Sema3A as a biological mediator with capacity to induce OA pain and disease progression that is directly regulated by gait mechanical loading. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 32 - 32
7 Aug 2023
Nicholls K Petsiou D Wilcocks K Shean K Anderson J Vachtsevanos L
Full Access

Abstract

Introduction

Surgery in patients with high body mass index (BMI) is more technically challenging and associated with increased complications post-operatively. Inferior clinical and functional mid-term results for high BMI patients undergoing high tibial osteotomy (HTO) relative to normal weight patients have been reported. This study discusses the clinical, radiological and functional outcomes of HTO surgery in patients with a high BMI.

Method

This is a retrospective study on patients undergoing HTO surgery using the Tomofix anatomical MHT plate between 2017 and 2022, with follow-up period of up to 5 years. The cohort was divided: non-obese (BMI <30 kg/m2) and obese (BMI>30 kg/m2). Pre and post operative functional scores were collected: Oxford Knee Score (OKS), EuroQol-5D and Tegner. Complications, plate survivorship and Mikulicz point recorded.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 32 - 32
1 Apr 2022
French J Filer J Hogan K Fletcher J Mitchell S
Full Access

Introduction. Computer hexapod assisted orthopaedic surgery (CHAOS) has previously been shown to provide a predictable and safe method for correcting multiplanar femoral deformity. We report the outcomes of tibial deformity correction using CHAOS, as well as a new cohort of femoral CHAOS procedures. Materials and Methods. Retrospective review of medical records and radiographs for patients who underwent CHAOS for lower limb deformity at our tertiary centre between 2012–2020. Results. There were 70 consecutive cases from 56 patients with no loss to follow-up. Mean age was 40 years (17 to 77); 59% male. There were 48 femoral and 22 tibial procedures. Method of fixation was intramedullary nailing in 47 cases and locking plates in 23. Multiplanar correction was required in 43 cases. The largest correction of rotation was 40 degrees, and angulation was 28 degrees. Mean mechanical axis deviation reduction per procedure was 17.2 mm, maximum 89 mm. Deformity correction was mechanically satisfactory in all patients bar one who was under-corrected, requiring revision. Complications from femoral surgery included one under-correction, two cases of non-union, and one pulmonary embolism. Complications from tibial surgery were one locking plate fatigue failure, one compartment syndrome, one pseudoaneurysm of the anterior tibial artery requiring stenting, and one transient neurapraxia of the common peroneal nerve. There were no deaths. Conclusions. CHAOS can be used for reliable correction of complex deformities of both the femur and tibia. The risk profile appears to differ between femoral and tibial surgeries


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 302 - 308
1 Feb 2022
Dala-Ali B Donnan L Masterton G Briggs L Kauiers C O’Sullivan M Calder P Eastwood DM

Aims. Osteofibrous dysplasia (OFD) is a rare benign lesion predominantly affecting the tibia in children. Its potential link to adamantinoma has influenced management. This international case series reviews the presentation of OFD and management approaches to improve our understanding of OFD. Methods. A retrospective review at three paediatric tertiary centres identified 101 cases of tibial OFD in 99 patients. The clinical records, radiological images, and histology were analyzed. Results. Mean age at presentation was 13.5 years (SD 12.4), and mean follow-up was 5.65 years (SD 5.51). At latest review, 62 lesions (61.4%) were in skeletally mature patients. The most common site of the tibial lesion was the anterior (76 lesions, 75.2%) cortex (63 lesions, 62.4%) of the middle third (52 lesions, 51.5%). Pain, swelling, and fracture were common presentations. Overall, 41 lesions (40.6%) presented with radiological deformity (> 10°): apex anterior in 97.6%. A total of 41 lesions (40.6%) were treated conservatively. Anterior bowing < 10° at presentation was found to be related to successful conservative management of OFD (p = 0.013, multivariable logistic regression). Intralesional excision was performed in 43 lesions (42.6%) and a wide excision of the lesion in 19 (18.8%). A high complication rate and surgical burden was found in those that underwent a wide excision regardless of technique employed. There was progression/recurrence in nine lesions (8.9%) but statistical analysis found no predictive factors. No OFD lesion transformed to adamantinoma. Conclusion. This study confirms OFD to be a benign bone condition with low rates of local progression and without malignant transformation. It is important to distinguish OFD from adamantinoma by a histological diagnosis. Focus should be on angular deformity, monitored with full-length tibial radiographs. Surgery is indicated in symptomatic patients and predicted by the severity of the initial angular deformity. Surgery should focus more on the deformity rather than the lesion. Cite this article: Bone Joint J 2022;104-B(2):302–308


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1725 - 1730
1 Nov 2021
Baumber R Gerrand C Cooper M Aston W

Aims

The incidence of bone metastases is between 20% to 75% depending on the type of cancer. As treatment improves, the number of patients who need surgical intervention is increasing. Identifying patients with a shorter life expectancy would allow surgical intervention with more durable reconstructions to be targeted to those most likely to benefit. While previous scoring systems have focused on surgical and oncological factors, there is a need to consider comorbidities and the physiological state of the patient, as these will also affect outcome. The primary aim of this study was to create a scoring system to estimate survival time in patients with bony metastases and to determine which factors may adversely affect this.

Methods

This was a retrospective study which included all patients who had presented for surgery with metastatic bone disease. The data collected included patient, surgical, and oncological variables. Univariable and multivariable analysis identified which factors were associated with a survival time of less than six months and less than one year. A model to predict survival based on these factors was developed using Cox regression.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 67 - 67
1 May 2016
Jones G Jaere M Clarke S Cobb J
Full Access

Introduction

Opening wedge high tibial osteotomy is an attractive surgical option for physically active patients with early osteoarthritis and varus malalignment. Unfortunately use of this surgical technique is frequently accompanied by an unintended increase in the posterior tibial slope, resulting in anterior tibial translation, and consequent altered knee kinematics and cartilage loading(1).

To address this unintended consequence, it has been recommended that the relative opening of the anteromedial and posterolateral corners of the osteotomy are calculated pre-operatively using trigonometry (1). This calculation assumes that the saw-cut is made parallel to the native posterior slope; yet given the current reliance on 2D images and the ‘surgeon's eye’ to guide the saw-cut, this assumption is questionable.

The aim of this study was to explore how accurately the native posterior tibial slope is reproduced with a traditional freehand osteotomy saw-cut, and whether novel 3D printed patient-specific guides improve this accuracy.

Methods

26 fourth year medical students with no prior experience of performing an osteotomy were asked to perform two osteotomy saw-cuts in foam cortical shell tibiae; one freehand, and one with a 3D printed surgical guide (Embody, London) that was designed using a CT scan of the bone model. The students were instructed to aim for parallelity with a hinge pin which had been inserted (with the use of a highly conforming 3D printed guide) parallel to the posterior slope of the native joint.

For the purpose of analysis, the sawbones were consistently orientated along their mechanical and anatomical tibial axes using custom moulded supports. Digital photographs taken in the plane of the osteotomy were analysed with ImageJ software to calculate the angular difference in the sagittal plane between the hinge-pin and saw-cut. Statistical analysis was performed with SPSS v21 (Chicago, Illinois); a paired t-test was used to compare the freehand and patient-specific guide techniques. Statistical significance was set at a p-value <0.05.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 86 - 86
1 Dec 2013
Bal BS Ivie C Davis M Crist B
Full Access

Introduction:. Patient-specific cutting guides (PSCG) built from imaging of the extremity can improve the accuracy of bone cuts during total knee replacement (TKR). Some reports have suggested that PSCG offer only marginal improvement in the accuracy of alignment and component positioning in TKA. We compared outcomes between TKRs done with PSCG versus standard, intramedullary-based instrumentation. Methods:. Blood loss, duration of surgery, alignment of the mechanical axis of the leg, and implant position on standing, long-leg, and standard lateral digital radiographs were compared between a CT-guided, custom-built TKA implant (n = 50; ConforMIS iTotal, Boston, MA) implanted with PSCG, versus an off-shelf posterior stabilized TKA implanted with standard instrumentation (n = 50; NKII total knee, Zimmer, Warsaw, IN). The fraction of outliers (>3 degrees) was calculated for the two groups. Results:. The mean mechanical axis of iTotal was 181 degrees with a fraction of outliers of 0.2, versus 178 degrees for NKII with fraction of outliers of 0.7. For frontal plane positioning of femoral components, fraction of outliers for iTotal was 0.04, versus 0.6 for NKII. For tibial components, corresponding values were 0.1 and 0.6, respectively. Sagittal plane outliers were 0.2 and 0.9, respectively, for femoral components; and 0.2 and 0.6 for tibial components. Surgery duration was 5 minutes less and blood loss was 100 mL less for iTotal than for intramedullary-aligned NKII. Conclusion:. Patient specific instrumentation and custom-built implants showed a trend toward improved accuracy of alignment, reduction in blood loss and operating time, when compared to standard, off-the-shelf TKA implants with intramedullary alignment, with fewer radiographic outliers. Larger, randomized trials are necessary to evaluate this technology further, but the initial outcomes appear favorable, with no cost disadvantage to the custom-built implant


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1263 - 1268
1 Sep 2013
Savaridas T Wallace RJ Salter DM Simpson AHRW

Fracture repair occurs by two broad mechanisms: direct healing, and indirect healing with callus formation. The effects of bisphosphonates on fracture repair have been assessed only in models of indirect fracture healing.

A rodent model of rigid compression plate fixation of a standardised tibial osteotomy was used. Ten skeletally mature Sprague–Dawley rats received daily subcutaneous injections of 1 µg/kg ibandronate (IBAN) and ten control rats received saline (control). Three weeks later a tibial osteotomy was rigidly fixed with compression plating. Six weeks later the animals were killed. Fracture repair was assessed with mechanical testing, radiographs and histology.

The mean stress at failure in a four-point bending test was significantly lower in the IBAN group compared with controls (8.69 Nmm-2 (sd 7.63) vs 24.65 Nmm-2 (sd 6.15); p = 0.017). On contact radiographs of the extricated tibiae the mean bone density assessment at the osteotomy site was lower in the IBAN group than in controls (3.7 mmAl (sd 0.75) vs 4.6 mmAl (sd 0.57); p = 0.01). In addition, histological analysis revealed progression to fracture union in the controls but impaired fracture healing in the IBAN group, with predominantly cartilage-like and undifferentiated mesenchymal tissue (p = 0.007).

Bisphosphonate treatment in a therapeutic dose, as used for risk reduction in fragility fractures, had an inhibitory effect on direct fracture healing. We propose that bisphosphonate therapy not be commenced until after the fracture has united if the fracture has been rigidly fixed and is undergoing direct osteonal healing.

Cite this article: Bone Joint J 2013;95-B:1263–8.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 57 - 57
1 Sep 2012
Whyte T Scholes C Li Q Coolican M Parker D
Full Access

High tibial osteotomy is a well established joint preserving procedure for the treatment of unicompartmental knee osteoarthritis. Of particular interest are the alterations in knee loading compartments during dynamic activities such as locomotion. Computer modelling can indirectly assess contact and muscle forces in the patient. This study aimed to develop a valid model representative of high tibial osteotomy to assess the medial joint contact force at the knee during gait. Software for Interactive Musculoskeletal Modelling (version 2, SIMM Inc, USA) was used to develop a model to replicate the effects of high tibial osteotomy surgery on tibial alignment. The program was then used to perform a detailed analysis on gait data collected from two high tibial osteotomy patients preoperatively and 6 months post operatively. Inverse dynamics simulations were conducted to investigate knee joint contact force on the medial compartment of the two patients during the stance phase of their operated limbs. Significant decreases (p<0.05) in the medial joint contact force were observed during both early and late stance for both patients. Force generated in muscles crossing the knee was found to be the major contributor to the joint contact force. Total muscle force was found to increase significantly (p<0.05) following surgery, however decreased loads were calculated for the medial compartment. The pattern and magnitude of joint reaction force was found to be consistent before and after surgery and replicated the results of previous studies. The HTO-specific model was valid and sensitive to changes in joint reaction force, medial joint contact force and muscle forces crossing the knee. High tibial osteotomy reduced the medial joint contact force at the knee as a result of the coronal realignment of the limb. Osteoarthritis symptoms were relieved in terms of knee pain and function. Finally, a difference in compensatory strategies was observed between patients. This novel technique allows non-invasive assessment of the mechanical effect of procedures such as HTO. This should allow more accurate planning and assessment of such surgical procedures


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1241 - 1245
1 Sep 2012
Burghardt RD Paley D Specht SC Herzenberg JE

Internal lengthening devices in the femur lengthen along the anatomical axis, potentially creating lateral shift of the mechanical axis. We aimed to determine whether femoral lengthening along the anatomical axis has an inadvertent effect on lower limb alignment. Isolated femoral lengthening using the Intramedullary Skeletal Kinetic Distractor was performed in 27 femora in 24 patients (mean age 32 years (16 to 57)). Patients who underwent simultaneous realignment procedures or concurrent tibial lengthening, or who developed mal- or nonunion, were excluded. Pre-operative and six-month post-operative radiographs were used to measure lower limb alignment. The mean lengthening achieved was 4.4 cm (1.5 to 8.0). In 26 of 27 limbs, the mechanical axis shifted laterally by a mean of 1.0 mm/cm of lengthening (0 to 3.5). In one femur that was initially in varus, a 3 mm medial shift occurred during a lengthening of 2.2 cm.

In a normally aligned limb, intramedullary lengthening along the anatomical axis of the femur results in a lateral shift of the mechanical axis by approximately 1 mm for each 1 cm of lengthening.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 53 - 53
1 Mar 2012
Hook S Melton J Wilson AJ Wandless F Thomas NP
Full Access

Improved surgical techniques and new fixation methods have revived interest in high tibial osteotomy surgery in recent years. Our aim was to review our first 59 cases. All patients underwent radiological and clinical review including pre and post operative scores. Mean age at surgery was 43 (22-59) and mean follow up is 22 months. The mean pre-operative limb alignment was 5.4° varus (range 1°-16°) with correction to 2° valgus (range -1° - 7°). HTO is known to increase tibial slope and in this series the change in tibial slope from -5.2° (95%CI: -6.36 to -4.07)) to -7.8° (-8.83 to –6.89) was statistically significant. p= 0.0014 (Mann Whitney). Patellar height is often reduced following opening wedge HTO and this is confirmed in our series. The Blackburne-Peel ratio changed from 0.74 to 0.58 and the Caton-Descamps from 0.83 to 0.7. Both were statistically significant at p<0.0001 and p=0.0001 respectively. All scores improved post operatively, the knee injury and osteoarthritis outcome (KOOS) from 48 (8-91) to 73 (27-96), the Oxford knee score (OKS) from 25 (3-47) to 37 (9-48), and the EQ5D from 189809 (11221-32333) to 14138 (11111-22233) with the EQ5D VAS improving from 58 to 75. There was no correlation between change in limb alignment, tibial slope or patellar height and any of the scores used. There were three superficial wound infections, and one non union which was treated with grafting and re fixation. Six patients have had their plate removed. Improvement in clinical scores in these patients confirms that medial opening wedge HTO is a reliable joint preserving procedure in the short term and our surgical technique is reproducible and consistent with other published series


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1388 - 1393
1 Oct 2009
Aird JJ Hogg A Rollinson P

In 1937 Blount described a series of 28 patients with ‘Tibia vara’. Since then, a number of deformities in the tibia and the femur have been described in association with this condition.

We analysed 14 children with Blount’s disease who were entered into a cross-sectional study. Their mean age was 10 (2 to 18). They underwent a clinical assessment of the rotational profile of their legs and a CT assessment of the angle of anteversion of their hips (femoral version). We compared our results to previously published controls. A statistically significant increase in femoral anteversion was noted in the affected legs, with on average the femurs in patients with Blount’s disease being 26° more anteverted than those in previously published controls.

We believe this to be a previously unrecognised component of Blount’s disease, and that the marked intoeing seen in the disease may be partly caused by internal femoral version, in addition to the well-recognised internal tibial version.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 345 - 345
1 Sep 2005
Hill N Fellows R MacIntyre N Tang T Ellis R Harrison M Wilson D
Full Access

Introduction and Aims: High tibial osteotomy (HTO) is a corrective surgical procedure used to treat medial compartment osteoarthritis (OA). In HTO a bone wedge is resected from the upper tibia to realign the lower limb. In this study, we investigated the effect of HTO on patellofemoral joint motion using a validated new technique. Method: We assessed patellar tracking in four subjects before and after high tibial osteotomy surgery. A high-resolution MR image was acquired of each subject’s knee. Each subject then loaded his/her knee in a custom test rig in the MR scanner, while fast, low-resolution MRI scans were acquired. This was repeated at five flexion angles. Bone outlines were identified (image segmentation) and processed (meshed) to yield bone models. Knee kinematics were determined by matching (registering) the high-resolution bone models to the low-resolution bony outlines. We compared the pre- and post-operative tracking patterns using a two-way repeated measures ANOVA. Results: The resultant patellar tracking patterns were expressed as a function of knee flexion. Mean values for each quantity were calculated over the flexion range. High tibial osteotomy decreased patellar flexion by a mean of 5.06 degrees (p < 0.003), decreased internal patellar spin by a mean of 1.25 degrees (p < 0.001) and increased medial patellar tilt by a mean of 1.59 degrees (p < 0.001). High tibial osteotomy increased proximal patellar translation by a mean of 4.19mm (p < 0.008), but, for the number of specimens tested, we found no significant change in anterior or medial translation. Conclusion: Our finding that HTO translated the patella proximally is consistent with findings of elevated patellae in the literature. The significant changes in patellar movement caused by high tibial osteotomy surgery suggest that the post-operative anterior knee pain associated with these procedures is due to mechanical changes at the patellofemoral joint


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 305 - 305
1 Nov 2002
Horesh Z Levy M Soudry M
Full Access

Introduction: Treating tibial plateau fractures extreme care should be given to restore articular surface height preserving knee joint stability to be able to obtain maximal range of movement and to prevent future joint degenerative changes. Preoperative evaluation with CT and 3-D reconstruction is mandatory to understand the topography of the fracture for surgical planning. Traditional bone grafting techniques together with newer bone substitutes should be utilized in addition to ligamentotaxis when necessary. Fixation with smooth or olive wires (in occasions with washers for wider contact), sometimes augmented by screws is used with the Ilizarov external frame for stabilization avoiding extended incisions. In unstable fractures, bridging of the knee with slight distraction of the joint is provided by including the distal femur to the frame with an additional ring. Guided by these principles, complex tibial plateau fractures were treated in our department and the results are reported. Materials and Methods: Ten patients 40.6 years old on average (30–70) with Schatzker type V–VI fractures (all closed) were treated by hybrid 3 ring Ilizarov external frames alone or in combination with another procedure. Six were treated by ligamentotaxis and Ilizarov fixation alone and minimal opening for joint surface elevation when needed. The remaining 4 needed 6.5 mm canulated cancellous screw augmentation and 2 of them additional bone graft supplementation. Two patients needed extension of the frame to the femur with hinges on the center of joint rotation. All patients remain non-WB for 6 weeks and partial WB for another 6 weeks. Within 3 months the frame was removed and replaced by a brace or a cast-brace with full WB. Physiotherapy started early after the operation. Results: The results were analyzed over an average follow-up period of 22.6 months (range 3–53). All fractures healed in an average of 12 weeks. Range of motion in all patients included full extension with 90° of flexion or more. No postoperative infections, septic arthritis or neurovascular complications were reported. Pin site infection was resolved locally. One case resulted in mild valgus alignment due to osteoporotic bone (70 years old patient). Discussion: Ilizarov external fixation for complex tibial plateau fractures offers the advantage of minimal invasive interventions with a high level of functionality since the early post operative period. The combination with minimal invasive opening for joint surface elevation and additional screws or bone graft extends even more the scope of the treatment. Functional results were similar to previous reported series. The good observance of traditional tibial plateau surgery principles should guide the surgeons when using this modality of treatment for optimal results