Advertisement for orthosearch.org.uk
Results 1 - 20 of 48
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 64 - 64
1 Jul 2022
Dayananda K Dalal S Thomas E Chandratreya A Kotwal R
Full Access

Abstract. INTRODUCTION. A paucity of literature exists regarding efficacy of lateral unloader bracing in treatment for pathologies effecting the lateral compartment of the knee. We evaluate patient outcomes following customised lateral unloader bracing (cLUB) in treatment of lateral compartment osteoarthritis (LCOA), lateral tibial plateau fractures (LTPF) and spontaneous osteonecrosis of knee (SONK). METHODS. Institutional study approval was obtained. All patients undergoing cLUB between January 2013 and January 2021 were included, and prospectively followed-up. Visual Analogue Scales (VAS), Oxford Knee Scores (OKS) and Knee Injury and Osteoarthritis Outcome Scores (KOOS) were assessed at brace fitting and final follow-up. Brace compliance, complications and surgical interventions were also collected. Statistical analysis utilised paired t-test. RESULTS. 71 patients (LCOA n=47, LTPF n=21, SONK n=3) were analysed. VAS, OKS and KOOS scores show significant improvements after bracing (p<0.05). Brace compliance was 90.5%. One patient developed a deep-vein thrombosis, 12.7% suffered skin irritation (n=5 LTPF/n=4 LCOA) managed with bio-skin calf sleeves, and brace intolerance occurred in 8.5% (n=6). Brace survivorship was 64.8% (n=46). Twenty-five patients underwent post-bracing surgery; LTPF n=2, LCOA n=22, SONK n=1. The mean time interval between brace fitting and arthroplasty for LKOA patients was 2.1 (range 0.5-4) years. CONCLUSION. Our cohort demonstrates good compliance and significant improvements with cLUB across acute and chronic pathologies. Surgery and associated risks were avoided in certain cases. Further research is required alongside a cost-analysis. However, with increasing disease burden and surgical waiting times cLUB could be a crucial component of management in selected knee pathology cases


Bone & Joint Research
Vol. 11, Issue 2 | Pages 82 - 90
7 Feb 2022
Eckert JA Bitsch RG Sonntag R Reiner T Schwarze M Jaeger S

Aims

The cemented Oxford unicompartmental knee arthroplasty (OUKA) features two variants: single and twin peg OUKA. The purpose of this study was to assess the stability of both variants in a worst-case scenario of bone defects and suboptimal cementation.

Methods

Single and twin pegs were implanted randomly allocated in 12 pairs of human fresh-frozen femora. We generated 5° bone defects at the posterior condyle. Relative movement was simulated using a servohydraulic pulser, and analyzed at 70°/115° knee flexion. Relative movement was surveyed at seven points of measurement on implant and bone, using an optic system.


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1075 - 1081
17 Dec 2021
Suthar A Yukata K Azuma Y Suetomi Y Yamazaki K Seki K Sakai T Fujii H

Aims

This study aimed to investigate the relationship between changes in patellar height and clinical outcomes at a mean follow-up of 7.7 years (5 to 10) after fixed-bearing posterior-stabilized total knee arthroplasty (PS-TKA).

Methods

We retrospectively evaluated knee radiographs of 165 knees, which underwent fixed-bearing PS-TKA with patella resurfacing. The incidence of patella baja and changes in patellar height over a minimum of five years of follow-up were determined using Insall-Salvati ratio (ISR) measurement. We examined whether patella baja (ISR < 0.8) at final follow-up affected clinical outcomes, knee joint range of motion (ROM), and Knee Society Score (KSS). We also assessed inter- and intrarater reliability of ISR measurements and focused on the relationship between patellar height reduction beyond measurement error and clinical outcomes.


Bone & Joint 360
Vol. 10, Issue 3 | Pages 35 - 37
1 Jun 2021


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1033 - 1040
1 Aug 2020
Kennedy JA Mohammad HR Yang I Mellon SJ Dodd CAF Pandit HG Murray DW

Aims

To report mid- to long-term results of Oxford mobile bearing domed lateral unicompartmental knee arthroplasty (UKA), and determine the effect of potential contraindications on outcome.

Methods

A total of 325 consecutive domed lateral UKAs undertaken for the recommended indications were included, and their functional and survival outcomes were assessed. The effects of age, weight, activity, and the presence of full-thickness erosions of cartilage in the patellofemoral joint on outcome were evaluated.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 861 - 867
1 Jul 2020
Hiranaka T Yoshikawa R Yoshida K Michishita K Nishimura T Nitta S Takashiba K Murray D

Aims

Cementless unicompartmental knee arthroplasty (UKA) has advantages over cemented UKA, including improved fixation, but has a higher risk of tibial plateau fracture, particularly in Japanese patients. The aim of this multicentre study was to determine when cementless tibial components could safely be used in Japanese patients based on the size and shape of the tibia.

Methods

The study involved 212 cementless Oxford UKAs which were undertaken in 174 patients in six hospitals. The medial eminence line (MEL), which is a line parallel to the tibial axis passing through the tip of medial intercondylar eminence, was drawn on preoperative radiographs. Knees were classified as having a very overhanging medial tibial condyle if this line passed medial to the medial tibial cortex. They were also classified as very small if a size A/AA tibial component was used.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 39 - 39
1 May 2019
Sharkey P
Full Access

Bone marrow lesions (BMLs), identified by MRI, are defined as a region of cancellous bone with high T2 and low T1 signal intensity. They are associated with various knee pathologies including spontaneous osteonecrosis of the knee (SPONK), AVN, trauma (fracture and bone contusion), following arthroscopy and secondary to overuse (i.e., after completing a marathon). They also are commonly recognised in patients with knee OA (referred to as OA-BMLs) and their substantial importance in knee OA pathogenesis has been recently identified. Depending upon the etiology (i.e., bone contusion, overuse, etc.) of the BML, these lesions can be “acute” in nature and spontaneously resolve over time. However, OA-BMLs generally are considered to be a “chronic” condition and overtime they have been shown to often persist and increase in size. Retrieval studies following THA and TKA, in patients with a preoperatively identified BML, have greatly expanded our understanding of OA – BMLs and these investigations consistently identify the critical role subchondral bone plays in OA disease progression. Histologic, histochemical and mechanical studies of OA-BMLs demonstrate significant alternations from healthy subchondral bone. The effected bone contains regions where fibrous tissue has replaced cancellous bone, microfractures are present and vascularity is increased. There is an increased concentration of inflammatory mediators and the bone structural integrity is compromised. Standard radiographs of the knee correlate only modestly with patient symptoms, but conversely, the presence of an OA-BML is an extremely strong predictor of pain and knee joint dysfunction. Felson et al. reported this relationship. In a large group of patients with painful knee OA, 77.5% of these patients had a BML. Both the presence and size of the BML, following multiregression analysis, were significant predictors of knee pain severity. Additionally, likely secondary to inadequate subchondral bone plate support, the presence of an OA-BML is associated with subchondral bone attrition (SBA). SBA leads to collapse of the subchondral bone plate and progressive joint deformity. Based on the association of an OA-BML with pain, joint dysfunction and deformity, it is not surprising that these lesions are prognostic for patients seeking knee arthroplasty. Several studies have demonstrated that the odds of knee arthroplasty performance are substantially higher in patents with an OA-BML. This enhanced understanding of knee OA pathogenesis and the critical role of subchondral bone in this process creates an opportunity for development of novel prevention and treatment strategies. Prevention of OA-BML formation has been considered and pharmacologic interventions proposed. Recent studies have reported positive results for treatment with bisphosphonates in patients with knee OA. One study reported significant pain and OA-BML size reduction in patients receiving a bisphosphonate for 4 months. A strategy aimed at repairing and/or enhancing subchondral bone compromised by an OA-BML has also been proposed. Early results reported with this intervention are encouraging, but preliminary


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 34 - 34
1 Apr 2019
Chang MJ Kang SB Chang CB Yoon C Kim W Shin JY Suh DW Oh JB Kim SJ Choi SH Kim SJ Baek HS
Full Access

The role of unicompartmental knee arthroplasty (UKA) in spontaneous osteonecrosis of the knee (SONK) remains controversial, even though SONK usually involves only medial compartment of the knee joint. We aimed to compare the survival rate and clinical outcomes of UKA in SONK and medial compartment osteoarthritis (MOA) via a meta-analysis of previous studies. MEDLINE database in PubMed, the Embase database, and the Cochrane Library were searched up to January 2018 with keywords related to SONK and UKA. Studies were selected with predetermined inclusion criteria: (1) medial UKA as the primary procedure, (2) reporting implant survival or clinical outcomes of osteonecrosis and osteoarthritis, and (3) follow-up period greater than 1 year. Quality assessment was performed using the risk of bias assessment tool for non-randomised studies (RoBANs). A random effects model was used to estimate the pooled relative risk (RR) and standardised mean difference. The incidence of UKA revision for any reason was significantly higher in SONK than in MOA group (pooled RR = 1.83, p = 0.009). However, the risk of revision due to aseptic loosening and all- cause re-operation was not significantly different between the groups. Moreover, when stratified by the study quality, high quality studies showed similar risk of overall revision in SONK and MOA (p = 0.71). Subgroup analysis revealed worse survival of SONK, mainly related to high failure after uncemented UKA. Clinical outcomes after UKA were similar between SONK and MOA (p = 0.66). Cemented UKA has similar survival and clinical outcomes in SONK and MOA. Prospective studies designed specifically to compare the UKA outcomes in SONK and MOA are necessary


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 9 - 9
1 Apr 2019
Fukuoka S Fukunaga K Taniura K Sasaki T Takaoka K
Full Access

Aims. Spontaneous osteonecrosis of the knee (SONK) mainly affects the medial femoral condyle, would be a good indication for UKA. The primary aim of this study was to assess the clinical, functional and radiographic outcomes at middle to long-term follow-up, of a consecutive series of fifty UKA used for the treatment of SONK. The secondary aim was to assess the volume of necrotic bone and determine if this influenced the outcome. Patients and Methods. We reviewed 50 knees who were treated for SONK. Patients included ten males and 38 females. The mean age was 73 years (range, 57 to 83 years). The mean height and body weight were, respectively 153 cm (141 ∼171 cm) and 57 kg (35 ∼75kg). All had been operated on using the Oxford mobile-bearing UKA (Zimmer-Biomet, Swindon, United Kingdom) with cement fixation. The mean follow-up period was 8.4 years (range, 4 to 15years). We measured the size (width, length and depth) and the volume to be estimated (width x length x depth) of the necrotic bone mass using MRI in T1-weighted images. The clinical results were evaluated using the Knee Society Scoring System (KSS) and Oxford Knee Score (OKS). The flexion angle of the knee was evaluated using lateral X-ray images in maximum flexion. Results. There were no implant failures, but there were 4 deaths (from causes unrelated to UKA) mean 6.6 years after surgery(5∼8), 3 cases were lost mean 3.3 years after surgery(2∼5). The mean size of the necrotic lesion were 17.2mm (14.7∼25.3) in width, 28.2mm (6.2∼38.3) in length and 11.3mm (3.2∼14.3) in depth. The mean volume of it was calculated to be approximate 5.4 cm. 3. (0.7∼11.1). The mean flexion of the knee, KSS Knee Score, Function Score and OKS increased from a preoperative 128.7 degrees (110 ∼ 140 degrees) to 137.5 degrees (110 ∼ 153 degrees), 52.3 (30 ∼ 64) to 91.3 (87 ∼ 100), 39.7 (15∼ 55) to 90.2 (65 ∼ 100) and 21.6 (12∼ 28) to 40.2 (34∼ 48), respectively at the latest follow-up. At last follow-up all patients had good or excellent OKS. Conclusions. There was a 100% survival rate of the Oxford Phase 3 UKA for SONK in the middle to long-term (up to 15 years after surgery) in this independent study. All patients had good/excellent results at last follow-up and there were no reoperations or major complications. This suggests that Oxford mobile-bearing UKA is a good and definitive treatment for medial femoral SONK, whatever the size of the lesion


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 79 - 79
1 Jun 2018
Mullaji A
Full Access

Since 2005, the author has performed nearly 1000 Oxford medial unicompartmental arthroplasties (UKA) using a mobile bearing. The indications are 1) Isolated medial compartment osteoarthritis with ‘bone-on-bone’ contact, which has failed prior conservative treatment, 2) Medial femoral condyle avascular necrosis or spontaneous osteonecrosis, which has failed prior conservative treatment. Patients are recommended for UKA only if the following anatomic requirements are met: 1) Intact ACL, 2) Full thickness articular cartilage wear limited to the anterior half of the medial tibial plateau, 3) Unaffected lateral compartment cartilage, 4) Unaffected patellar cartilage on the lateral facet, 5) Less than 10 degrees of flexion deformity, 6) Over 100 degrees of knee flexion, and 7) Varus deformity not exceeding 15 degrees. Exclusion criteria for surgery are BMI of more than 30, prior high tibial osteotomy, and inflammatory arthritis. All cases were performed with a tourniquet inflated using a minimally-invasive incision with a quadriceps-sparing approach. Both femoral and tibial components were cemented. Most patients were discharged home the next morning; bilaterals usually stayed a day longer. We have previously described our results and the factors determining alignment. In a more recent study, we have compared the coronal post-operative limb alignment and knee joint line obliquity after medial UKA with a clinically and radiologically (less than Grade 2 medial OA) normal contralateral lower limb. In our series, we have had 1 revision for aseptic loosening of both components, conversion to TKRs in a patient with bilateral UKAs who developed rheumatoid arthritis 3 years later, and 9 meniscal dislocations. There have been no cases of wound infections and thromboembolism. We have reviewed our patients with a minimum 10-year follow-up which will be presented. The vast majority of our patients have been generally very satisfied with the results. Our study shows that most patients (who have no disease in the contralateral knee) regain their ‘natural’ alignment and joint line obliquity comparable to their contralateral limb. Over the past few years our percentage of UKAs has been steadily rising to about a third of our knee cases. UKA serves as a definitive procedure in the elderly. We see it as a suitable procedure in middle-aged patients who want an operation that provides a quick recovery, full function and range of motion, and near-normal kinematics, with the understanding that they have a small chance of conversion to a total knee arthroplasty in the future


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 450 - 454
1 Apr 2018
Chalmers BP Mehrotra KG Sierra RJ Pagnano MW Taunton MJ Abdel MP

Aims

Primary (or spontaneous) and secondary osteonecrosis of the knee can lead to severe joint degeneration, for which either total or unicompartmental arthroplasty may be considered. However, there are limited studies analyzing outcomes of unicompartmental knee arthroplasties (UKAs) for osteonecrosis involving an isolated compartment of the knee. The aims of this study were to analyze outcomes of UKAs for osteonecrosis with specific focus on 1) survivorship free of any revision or reoperation, 2) risk factors for failure, 3) clinical outcomes, and 4) complications.

Patients and Methods

A total of 45 patients underwent 46 UKAs for knee osteonecrosis between 2002 and 2014 at our institution (The Mayo Clinic, Rochester, Minnesota). Twenty patients (44%) were female; the mean age of the patients was 66 years, and mean body mass index (BMI) was 31 kg/m2. Of the 46 UKAs, 44 (96%) were medial UKAs, and 35 (76%) were fixed-bearing design. Mean mechanical axis postoperatively was 1.5° varus (0° to 5° varus); 41 UKAs (89%) were performed for primary osteonecrosis. Mean follow-up was five years (2 to 12)


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 887 - 893
1 Jul 2017
Ogawa H Matsumoto K Akiyama H

Aims

We aimed to investigate factors related to the technique of medial opening wedge high tibial osteotomy which might predispose to the development of a lateral hinge fracture.

Patients and Methods

A total of 71 patients with 82 osteotomies were included in the study. Their mean age was 62.9 years (37 to 80). The classification of the type of osteotomy was based on whether it extended beyond the fibular head. The level of the osteotomy was classified according to the height of its endpoint.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 101 - 101
1 May 2017
Jordan R Aparajit P Docker C El-Shazly M
Full Access

Introduction. Osteonecrosis of the knee encompasses three conditions; spontaneous osteonecrosis of the knee, secondary osteonecrosis (ON) and post-arthroscopic ON. Early stage lesions can be managed by non-operative measures that include protected weight-bearing and analgesia. The aim of this study was to report the experience of the authors in managing early stages of knee ON by analysing the functional outcome and need for surgical intervention. Methods. All patients treated for osteonecrosis of the knee between 1st August 2001 and 1st April 2014 were prospectively collected. Treatment consisted of touch-down weight bearing for four to six weeks. The cases were retrospectively reviewed. MR imaging was evaluated for the stage of disease according to Koshino's Classification system, the condyles involved and the time taken for resolution. Tegner Activity Scale, VAS pain, Lysholm, WOMAC and IKDC scores were recorded at presentation and final follow up. Results. 51 cases were treated for knee ON at our centre; 40 cases of SONK, seven secondary ON and four post-arthroscopic ON. Of the seven cases of secondary osteonecrosis; 5 were secondary to self-reported high ethanol intake and two secondary to corticosteroid treatment. The mean age of the group was 56.9 years and 68.7% were male. The medial femoral condyle was the most commonly affected (54.9%). 86% reported resolution of clinical symptoms and a statistically significant improvement was reported in all functional outcome measures. Four patients required total knee arthroplasty; three in the post-arthroscopic group within 15 months and one following ON secondary to corticosteroids performed at 5 months. Conclusion. Early stage spontaneous osteonecrosis of the knee can be managed successfully without surgery if diagnosed early. Although secondary and post-arthroscopic ON seem to be more resistant. Larger studies are required to confirm or refute this. Level of Evidence. IV – a case series. Conflict of Interests. The authors confirm that they have no relevant financial disclosures or conflicts of interest. Ethical approval was not sought as this was a systematic review


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 475 - 482
1 Apr 2017
Hamilton TW Pandit HG Inabathula A Ostlere SJ Jenkins C Mellon SJ Dodd CAF Murray DW

Aims

While medial unicompartmental knee arthroplasty (UKA) is indicated for patients with full-thickness cartilage loss, it is occasionally used to treat those with partial-thickness loss. The aim of this study was to investigate the five-year outcomes in a consecutive series of UKAs used in patients with partial thickness cartilage loss in the medial compartment of the knee.

Patients and Methods

Between 2002 and 2014, 94 consecutive UKAs were undertaken in 90 patients with partial thickness cartilage loss and followed up independently for a mean of six years (1 to 13). These patients had partial thickness cartilage loss either on both femur and tibia (13 knees), or on either the femur or the tibia, with full thickness loss on the other surface of the joint (18 and 63 knees respectively). Using propensity score analysis, these patients were matched 1:2 based on age, gender and pre-operative Oxford Knee Score (OKS) with knees with full thickness loss on both the femur and tibia. The functional outcomes, implant survival and incidence of re-operations were assessed at one, two and five years post-operatively. A subgroup of 36 knees in 36 patients with partial thickness cartilage loss, who had pre-operative MRI scans, was assessed to identify whether there were any factors identified on MRI that predicted the outcome.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 78 - 78
1 Jan 2017
Yasuda T Konishi H Morita Y Miyazaki Y Hayashi M Yamawaki Y Yoshimoto K Sueyoshi T Ota S Fujita S Onishi E Iwaki K Yamamoto H
Full Access

Medial meniscus tear has been proposed as a potential etiology of spontaneous osteonecrosis of the knee (SONK). Disruption of collagen fibers within the meniscus causes meniscal extrusion, which results in alteration in load distribution in the knee. A recent study has demonstrated high incidence of medial meniscus extrusion in the knee with SONK. Our purpose was to determine whether the extent of medial meniscus extrusion correlates with the severity of SONK in the medial femoral condyle. Anteroposterior and lateral knee radiographs were taken with the patients standing. Limb alignment was expressed as the femorotibial angle (FTA) obtained from the anteroposterior radiograph. The stage of progression of SONK was determined according to the radiological classification system described by Koshino. After measurement of anteroposterior, mediolateral, and superoinferior dimensions of the hypointense T1 signal intensity lesion of MRI, its ellipsoid volume was calculated with the three dimensions. Meniscal pathology (degeneration, tear, and extrusion) were also evaluated by MRI. Of the 18 knees with SONK, we found 5 knees at the radiological stage 2 lesions, 9 knees at the stage 3, and 4 knees at the stage 4. Whereas the ellipsoid volume of SONK lesion significantly increased with the stage progression, the volume was significantly greater at stage 4 than stage 2 or 3. All the 18 knees with SONK in the present study showed substantial extrusion (> 3mm) and degeneration of the medial meniscus. While medial meniscal extrusion increased with the stage progression, medial meniscus was significantly extruded at stage 3 or 4 compared with stage 2. A significant increase in FTA was found with the stage progression. FTA was significantly greater at stage 4 than stage 2 or 3. Multiple linear regression analysis revealed that medial meniscus extrusion and FTA were useful predictors of the volume of SONK lesion. This study has clearly shown a significant correlation between the extent of medial meniscus extrusion and the stage and volume of SONK lesion. Degeneration and tears of the medial meniscus in combination with extrusion may result in loss of hoop stress distribution in the medial compartment, which could increase the load in the medial femoral condyle. In addition to meniscal pathology, knee alignment can influence load distribution in the medial compartment biomechanically. Multiple linear regression analysis indicates that an increase in FTA concomitant with a greater extrusion of medial meniscus could result in greater lesion and advanced radiological stage of SONK. Taken together, alteration in compressive force transmission through the medial compartment by meniscus extrusion and varus alignment could develop subchondral insufficiency fractures in the medial femoral condyle, which is considered to be one of the main contributing factors to SONK development. There was high association of medial meniscus extrusion and FTA with the radiological stage and volume of SONK lesion. Increased loading in the medial femoral condyle with greater extrusion of medial meniscus and varus alignment may contribute to expansion and secondary osteoarthritic changes of SONK lesion


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 71 - 71
1 Dec 2016
Mullaji A
Full Access

Since 2005, the author has performed 422 Oxford medial unicompartmental arthroplasties (UKA) using a mobile bearing. There were 263 females and 119 males, (40 patients had bilateral UKAs) with a mean age of 62 years. The indications were: Isolated medial compartment osteoarthritis with ‘bone-on-bone’ contact, which had failed prior conservative treatment; Medial femoral condyle avascular necrosis or spontaneous osteonecrosis, which had failed prior conservative treatment. Patients were recommended UKA only if the following anatomic requirements were met: Intact ACL, Full thickness articular cartilage wear limited to the anterior half of the medial tibial plateau, Unaffected lateral compartment cartilage, Unaffected patellar cartilage on the lateral facet, Less than 10 degrees of flexion deformity, Over 100 degrees of knee flexion, Varus deformity not exceeding 15 degrees. Exclusion criteria for surgery were BMI of more than 30, prior high tibial osteotomy, and inflammatory arthritis. All cases were performed with a tourniquet inflated using a minimally-invasive incision with a quadriceps-sparing approach. Both femoral and tibial components were cemented. Rehabilitation consisted of teaching the patients 6 exercises to regain strength and range of motion, and weight-bearing as tolerated with a cane began from the evening of surgery. Most patients were discharged home the next morning; bilaterals usually stayed a day longer. We have previously described our results and the factors determining alignment. In a more recent study we have compared the coronal postoperative limb alignment and knee joint line obliquity after medial UKA with a clinically and radiologically (less than Grade 2 medial OA) normal contralateral lower limb. In our series of 423 cases, we have had 1 revision for aseptic loosening of both components, and 4 meniscal dislocations. There have been no cases of wound infections and thromboembolism. We are currently undertaking a review of the 2–10 year follow-up of our cases. The vast majority of our patients have been generally very satisfied with the results. Our study shows that most patients (who have no disease in the contralateral knee) regain their ‘natural’ alignment and joint line obliquity comparable to their contralateral limb. Over the past few years our percentage of UKAs has been steadily rising. UKA serves as a definitive procedure in the elderly. We see it as a suitable procedure in middle-aged patients who want an operation that provides a quick recovery, full function and range of motion, and near-normal kinematics, with the understanding that they have a small chance of conversion to a total knee arthroplasty in the future


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 3 - 10
1 Oct 2016
Hamilton TW Pandit HG Lombardi AV Adams JB Oosthuizen CR Clavé A Dodd CAF Berend KR Murray DW

Aims

An evidence-based radiographic Decision Aid for meniscal-bearing unicompartmental knee arthroplasty (UKA) has been developed and this study investigates its performance at an independent centre.

Patients and Methods

Pre-operative radiographs, including stress views, from a consecutive cohort of 550 knees undergoing arthroplasty (UKA or total knee arthroplasty; TKA) by a single-surgeon were assessed. Suitability for UKA was determined using the Decision Aid, with the assessor blinded to treatment received, and compared with actual treatment received, which was determined by an experienced UKA surgeon based on history, examination, radiographic assessment including stress radiographs, and intra-operative assessment in line with the recommended indications as described in the literature.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 94 - 94
1 May 2016
Uboldi F Ferrua P Pasqualotto S Carimati G Usellini E Berruto M
Full Access

Purpose. Osteochondral lesions of the knee are relatively common both in young and senior population. The very disabling clinical symptoms, in association to the scarce regenerative capacity of the articular cartilage and the increased risk of developing a secondary osteoarthritis make an effective treatment mandatory. Methods and Materials. From December 2008 to January 2013, 34 patients (35 knees), 24 males and 10 females (mean age 36.2 years range 14–66) underwent implant of Maioregen® (Finceramica Faenza S.P.A, Italy) biomimetic tri-layer osteochondral scaffold. In 17 cases the osteochondral lesion was cause by an osteochondritis dissecans (acute or sequela), in 13 cases by a spontaneous osteonecrosis and in 4 cases the etiology was traumatic. Patients were evaluated with subjective IKDC and Tegner Lysholm scores, VAS and Tegner Activity Scale before surgery and at regular follow up (mean follow up 38.4 months, range 13 months max 63 months). Results. Both Lysholm and IKDC Subjective scores significantly increased from 57.5 and 48.2 before surgery to 89.7 and 76.3 at 1 year follow up. Mean VAS scale score decreased from 6.3 to 2 at 1 year follow up. At 3 years follow up 20 evaluated patients showed an increment on both scales (Lysholm 92.38, IKDC 84.7). Only 4 patients were evaluated at 5 years follow up with mean subjective IKDC 92.5, Lysholm 98.75 and VAS 1. Conclusion. Maioregen® biomimetic osteochondral scaffold showed very good results as surgical treatment option in treating ICRS grade 3–4 osteochondral lesions whatever the etiology. In particular, the implant showed good results also in treatment of osteonecrosis and could provide an alternative to unicompartimental arthroplasty in young and active patients


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 83 - 83
1 Jan 2016
Uboldi FM Ferrua P Pasqualotto S Carimati G Zedde P Berruto M
Full Access

INTRODUCTION. Osteochondral lesions of the knee are relatively common both in young and senior population. The very disabling clinical symptoms, in association to the scarce regenerative capacity of the articular cartilage and the increased risk of developing a secondary osteoarthritis make an effective treatment mandatory. MATERIALS AND METHODS. From December 2008 to January 2013, 34 patients (35 knees), 24 males and 10 females (mean age 36.2 years range 14–66) underwent implant of Maioregen® (Finceramica Faenza S.P.A, Italy) biomimetic osteochondral scaffold. In 17 cases the osteochondral lesion was cause by an osteochondritis dissecans (acute or sequela), in 13 cases by a spontaneous osteonecrosis and in 4 cases the etiology was traumatic. Patients were evaluated with subjective IKDC and Tegner Lysholm scores, VAS and Tegner Activity Scale before surgery and at regular follow up (mean follow up 38.4 months, range 13 months max 63 months). RESULTS. Both Lysholm and IKDC Subjective scores significantly increased from 57.5 and 48.2 before surgery to 89.7 and 76.3 at 1 year follow up. Mean VAS scale score decreased from 6.3 to 2 at 1 year follow up. At 3 years follow up 20 evaluated patients showed an increment on both scales (Lysholm 92.38, IKDC 84.7). Only 4 patients were evaluated at 5 years follow up with mean subjective IKDC 92.5, Lysholm 98.75 and VAS 1. DISCUSSION. Maioregen ® biomimetic osteochondral scaffold showed very good results as surgical treatment option in treating ICRS grade 3–4 osteochondral lesions whatever the etiology. In particular, the implant showed good results also in treatment of osteonecrosis and could provide an alternative to unicompartimental arthroplasty in young and active patients


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 141 - 141
1 Jan 2016
Ryu K Suzuki T Iriuchishima T Kojima K Saito S Ishii T Nagaoka M Tokuhashi Y
Full Access

Objective. Mobile bearing unicompartmental knee arthroplasty (UKA) is an effective and safe treatment for osteoarthritis of the medial compartment. However, mobile-bearing UKA needs accurate ligament balancing of flexion and extension gaps to prevent dislocation of the mobile meniscal bearing. Instability can lead to dislocation of the insert. The phase 3 instruments of the Oxford UKA use a balancing technique for the flexion gap (90° of flexion) and extension gap (20° of flexion), thereby focusing attention on satisfactory soft tissue balancing. With this technique, spacers are used to balance the flexion and extension gap. However, gap kinematics in another flexion angle of mobile-bearing UKA is unclear. We developed UKA tensor for mobile-bearing UKA and we assessed the accurate gap kinematics of UKA. Materials and Methods. Between 2012 and 2013, The Phase 3 Oxford Partial Knee UKA (Biomet Inc., Warsaw, IN) were carried out in 48 patients (71 knees) for unicompartmental knee osteoarthritis or spontaneous osteonecrosis of the medial compartment. The mean age of patients at surgery was 71.6 years and the mean follow-up period was 1.7 years. The mean preoperative coronal plane alignment was 7.4° in varus. The indications for UKA included disabling knee pain with medial compartment disease; intact ACL and collateral ligaments; preoperative contracture of less than 15°; and preoperative deformity of <15°. Each surgery was performed by using different spacer block with 1-mm increments and the meniscal bearing lift-off tests according to surgical technique. We developed newly tensor for mobile bearing UKA which designed to permit surgeons to measure multiple range of the joint medial compartment/joint component gap, while applying a constant joint distraction force (Figure 1). We assessed the intra-operative joint gap measurements at 0, 20, 60, 90 and 120 of flexion with 100N, 125N and 150N of joint distraction forces. Results. The gaps measured were 0°: 8.6 ± 1.6, 20°: 9.2 ± 1.4, 60°: 9.6 ± 1.2, 90°: 11.1 ± 1.3, 120°: 11.6 ± 1.8 in 100 N, 0°: 9.7 ± 1.7, 20°: 11.2 ± 1.3, 60°: 11.4 ± 1.3, 90°: 11.9 ± 1.5, 120°: 10.4 ± 1.6 in 125 N, 0°: 11.3±1.4, 20°: 11.8 ± 1.3, 60°: 11.1 ± 1.2, 90°: 12.5 ± 1.3, 120°: 11.9 ± 1.6 in 150N (Figure 2). There was a significant difference between full extension to extension (20° of flexion) and flexion (90° of flexion) to full flexion (120° of flexion). Conclusion. Mobile bearing UKA instrumentation using a balancing technique by spacer block for the flexion gap (90° of flexion) and extension gap (20° of flexion), full extension gap was significantly smaller than extension gap and flexion gap was significantly smaller than full flexion gap in 100N, 125N and 150N of joint distraction forces