Advertisement for orthosearch.org.uk
Results 1 - 20 of 35
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1199 - 1202
1 Nov 2024
Watts AC Tennent TD Haddad FS


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1036 - 1038
1 Oct 2024
Tennent TD Watts AC Haddad FS


Bone & Joint 360
Vol. 12, Issue 6 | Pages 49 - 51
1 Dec 2023
Burden EG Whitehouse MR Evans JT


Bone & Joint 360
Vol. 12, Issue 4 | Pages 48 - 48
1 Aug 2023


Bone & Joint 360
Vol. 12, Issue 3 | Pages 44 - 44
1 Jun 2023


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 3 - 3
1 Dec 2022
Leardini A Caravaggi P Ortolani M Durante S Belvedere C
Full Access

Among the advanced technology developed and tested for orthopaedic surgery, the Rizzoli (IOR) has a long experience on custom-made design and implant of devices for joint and bone replacements. This follows the recent advancements in additive manufacturing, which now allows to obtain products also in metal alloy by deposition of material layer-by-layer according to a digital model. The process starts from medical image, goes through anatomical modelling, prosthesis design, prototyping, and final production in 3D printers and in case post-production. These devices have demonstrated already to be accurate enough to address properly the specific needs and conditions of the patient and of his/her physician. These guarantee also minimum removal of the tissues, partial replacements, no size related issues, minimal invasiveness, limited instrumentation. The thorough preparation of the treatment results also in a considerable shortening of the surgical and of recovery time. The necessary additional efforts and costs of custom-made implants seem to be well balanced by these advantages and savings, which shall include the lower failures and revision surgery rates. This also allows thoughtful optimization of the component-to-bone interfaces, by advanced lattice structures, with topologies mimicking the trabecular bone, possibly to promote osteointegration and to prevent infection. IOR's experience comprises all sub-disciplines and anatomical areas, here mentioned in historical order. Originally, several systems of Patient-Specific instrumentation have been exploited in total knee and total ankle replacements. A few massive osteoarticular reconstructions in the shank and foot for severe bone fractures were performed, starting from mirroring the contralateral area. Something very similar was performed also for pelvic surgery in the Oncology department, where massive skeletal reconstructions for bone tumours are necessary. To this aim, in addition to the standard anatomical modelling, prosthesis design, technical/technological refinements, and manufacturing, surgical guides for the correct execution of the osteotomies are also designed and 3D printed. Another original experience is about en-block replacement of vertebral bodies for severe bone loss, in particular for tumours. In this project, technological and biological aspects have also been addressed, to enhance osteointegration and to diminish the risk of infection. In our series there is also a case of successful custom reconstruction of the anterior chest wall. Initial experiences are in progress also for shoulder and elbow surgery, in particular for pre-op planning and surgical guide design in complex re-alignment osteotomies for severe bone deformities. Also in complex flat-foot deformities, in preparation of surgical corrections, 3D digital reconstruction and 3D printing in cheap ABS filaments have been valuable, for indication, planning of surgery and patient communication; with special materials mimicking bone strength, these 3D physical models are precious also for training and preparation of the surgery. In Paediatric surgery severe multi planar & multifocal deformities in children are addressed with personalized pre-op planning and custom cutting-guides for the necessary osteotomies, most of which require custom allografts. A number of complex hip revision surgeries have been performed, where 3D reconstruction for possible final solutions with exact implants on the remaining bone were developed. Elective surgery has been addressed as well, in particular the customization of an original total ankle replacement designed at IOR. Also a novel system with a high-tibial-osteotomy, including a custom cutting jig and the fixation plate was tested. An initial experience for the design and test of custom ankle & foot orthotics is also in progress, starting with 3D surface scanning of the shank and foot including the plantar aspect. Clearly, for achieving these results, multi-disciplinary teams have been formed, including physicians, radiologists, bioengineers and technologists, working together for the same goal


Bone & Joint 360
Vol. 10, Issue 3 | Pages 20 - 23
1 Jun 2021


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 74 - 74
1 Feb 2020
DeVito P Damodar D Berglund D Vakharia R Moeller E Giveans M Horn B Malarkey A Levy J
Full Access

Background. The purpose of this study was to determine if thresholds regarding the percentage of maximal improvement in the Simple Shoulder Test (SST) and American Shoulder and Elbow Surgery (ASES) score exist that predict “excellent” patient s­atisfaction (PS) following reverse total shoulder arthroplasty (RSA). Methods. Patients undergoing RSA using a single implant system were evaluated pre-operatively and at a minimum 2-year follow-up. Receiver-operating-characteristic (ROC) curve analysis determined thresholds to predict “excellent” PS by evaluating the percentage of maximal improvement for SST and ASES. Pre-operative factors were analyzed as independent predictors for achieving SST and ASES thresholds. Results. 198 (SST) and 196 (ASES) patients met inclusion criteria. For SST and ASES, ROC analysis identified 61.3% (p<.001) and 68.2% (p<.001) maximal improvement as the threshold for maximal predictability of “excellent” satisfaction respectively. Significant positive correlation between the percentage of maximum score achieved and “excellent” PS for both groups were found (r=.440, p<.001 for SST score; r=0.417, p<.001 for ASES score). Surgery on the dominant hand, greater baseline VAS Pain, and cuff arthropathy were independent predictors for achieving the SST and ASES threshold. Conclusion. Achievement of 61.3% of maximal SST score improvement and 68.3% of maximal ASES score improvement represent thresholds for the achievement of “excellent” satisfaction following RSA. Independent predictors of achieving these thresholds were dominant sided surgery and higher baseline pain VAS scores for SST, and rotator cuff arthropathy for ASES. Keywords. Percentage of maximal improvement; Predictors; American Shoulder and Elbow Surgery Score; Simply Shoulder Test; Reverse shoulder Arthroplasty; Satisfaction. Level of Evidence. Level III


Bone & Joint 360
Vol. 8, Issue 4 | Pages 49 - 49
1 Aug 2019


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 627 - 634
1 Jun 2019
King JJ Dalton SS Gulotta LV Wright TW Schoch BS

Aims

Acromial fractures following reverse shoulder arthroplasty (RSA) have a wide range of incidences in reported case series. This study evaluates their incidence following RSA by systematically reviewing the current literature.

Materials and Methods

A systematic review using the search terms “reverse shoulder”, “reverse total shoulder”, or “inverted shoulder” was performed using PubMed, Web of Science, and Cochrane databases between 1 January 2010 and 31 March 2018. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used. Studies were included if they reported on RSA outcomes and the incidence rate of acromial and/or scapular spine fractures. The rate of these fractures was evaluated for primary RSA, revision RSA, RSA indications, and RSA implant design.


Bone & Joint 360
Vol. 8, Issue 3 | Pages 45 - 45
1 Jun 2019


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 42 - 42
1 Nov 2018
Nolan B
Full Access

Increasingly more emphasis is being placed on Patient Reported Outcome Measures (PROMs). There are many used and reported in clinical studies, but there are no universally accepted or preferred measures. It is important for a researcher with a non-clinical background to understand how these assessments are performed, the type of information provided by each of the measures, and which diseases states are best reported by each measure.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 94 - 99
1 Jan 2017
Kim JM Zimmerman RM Jones CM Muhit AA Higgins JP Means Jr KR

Aims

Our purpose was to determine the quality of current randomised controlled trials (RCTs) in hand surgery using standardised metrics.

Materials and Methods

Based on five-year mean impact factors, we selected the six journals that routinely publish studies of upper extremity surgery. Using a journal-specific search query, 62 RCTs met our inclusion criteria. Then three blinded reviewers used the Jadad and revised Coleman Methodology Score (RCMS) to assess the quality of the manuscripts.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 26 - 26
1 Nov 2016
Larouche P Andrade J Reilly C Mulpuri K
Full Access

A commonly misunderstood principle in medical literature is statistical significance. Often, statistically non-significant or negative results are thought to be evidence for equivalence; mistakenly validating treatment modalities and putting patients at risk. This study examines the prevalence of misinterpretation of negative results of superiority trials in orthopaedic literature and outlines the need for a non-inferiority or equivalence research design. Four orthopaedic journals – Journal of Paediatric Orthopaedics A, Journal of Bone and Joint Surgery American Volume, Journal of Arthroplasty and Journal of Shoulder and Elbow Surgery – were hand searched to identify all randomised control trials (RCTs) published within the time periods 2002–2003, 2007–2008 and 2012–2013. The identified RCTs were read and classified by study methodology, results obtained, and interpretation of results. A total of 237 RCTs were identified. When analysing the primary outcomes, 117 (49.4%) studies yielded negative results and 120 (50.8%) yielded positive results. Out of the 237 articles, 231 (97.5%) used superiority methodology and 6 (2.5%) used non-inferiority or equivalence methodology. Of the 231 studies that used superiority methodology, 115 (49.8%) obtained negative results; and 45 (39.1%) of those misinterpreted the negative results for equivalence. While no statistical differences were seen, there was an upward trend in utilising non-inferiority and equivalence methodologies over time. Given the frequency of misinterpreted negative results, there is an evident need for a more appropriate research methodology that shows equivalence of treatment methods. A non-inferiority or equivalence study design can address orthopaedic clinical dilemmas more suitably when trying to show one treatment is no worse or is equal to another treatment. Regarding orthopaedic treatment modalities as equivalent when studies show negative statistical results can be detrimental to patients and their clinical outcomes. A non-inferiority methodology can be used to accurately depict no difference between treatment methods rather than attempting to show one treatment method as superior


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 83 - 83
1 May 2016
Karelse A Van Tongel A Verstraeten T Poncet D De Wilde L
Full Access

BACKGROUND. Abnormal glenoid version positioning has been recognized as a cause of glenoid component failure caused by the rocking horse phenomenon. In contrast, the importance of the glenoid inclination has not been investigated. MATERIALS AND METHODS. The computed tomography scans of 152 healthy shoulders were evaluated. A virtual glenoid component was positioned in 2 different planes: the maximum circular plane (MCP) and the inferior circle plane (ICP). The MCP was defined by the best fitting circle of the most superior point of the glenoid and 2 points at the lower glenoid rim. The ICP was defined by the best fitting circle on the rim of the inferior quadrants. The inclination of both planes was measured as the intersection with the scapular plane. We defined the force vector of the rotator force couple and calculated the magnitude of the shear force vector on a virtual glenoid component in both planes during glenohumeral abduction. RESULTS. The inclination of the component positioned in the MCP averaged 95° (range, 84°–108°) and for the ICP averaged 111° (range, 94°–126°). A significant reduction in shear forces was calculated for the glenoid component in the ICP vs the MCP: 98% reduction in 60° of abduction to 49% reduction in 90° of abduction. CONCLUSION. Shear forces are significantly higher when the glenoid component is positioned in the MCP compared with the ICP, and this is more pronounced in early abduction. Positioning the glenoid component in the inferior circle might reduce the risk of a rocking horse phenomenon. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 75 - 80
1 Jan 2016
Merolla G Chin P Sasyniuk TM Paladini P Porcellini G

Aims

We evaluated clinical and radiographic outcomes of total shoulder arthroplasty (TSA) using the second-generation Trabecular Metal (TM) Glenoid component. The first generation component was withdrawn in 2005 after a series of failures were reported. Between 2009 and 2012, 40 consecutive patients with unilateral TSA using the second-generation component were enrolled in this clinical study. The mean age of the patients was 63.8 years (40 to 75) and the mean follow-up was 38 months (24 to 42).

Methods

Patients were evaluated using the Constant score (CS), the American Shoulder and Elbow Surgeons (ASES) score and routine radiographs.


Bone & Joint 360
Vol. 3, Issue 6 | Pages 39 - 40
1 Dec 2014
Foy MA


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 574 - 579
1 May 2014
Talbot CL Ring J Holt EM

We present a review of claims made to the NHS Litigation Authority (NHSLA) by patients with conditions affecting the shoulder and elbow, and identify areas of dissatisfaction and potential improvement. Between 1995 and 2012, the NHSLA recorded 811 claims related to the shoulder and elbow, 581 of which were settled. This comprised 364 shoulder (64%), and 217 elbow (36%) claims. A total of £18.2 million was paid out in settled claims. Overall diagnosis, mismanagement and intra-operative nerve injury were the most common reasons for litigation. The highest cost paid out resulted from claims dealing with incorrect, missed or delayed diagnosis, with just under £6 million paid out overall. Fractures and dislocations around the shoulder and elbow were common injuries in this category. All 11 claims following wrong-site surgery that were settled led to successful payouts.

This study highlights the diagnoses and procedures that need to be treated with particular vigilance. Having an awareness of the areas that lead to litigation in shoulder and elbow surgery will help to reduce inadvertent risks to patients and prevent dissatisfaction and possible litigation.

Cite this article: Bone Joint J 2014; 96-B:574–9.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 714 - 717
1 May 2013
Yates P Kellett C Huntley JS Whitwell D Reed MR Beadel G Snyckers C

In May 2012, in airports across the globe, seven orthopaedic surgeons bravely said goodbye to their loved ones, and slowly turned towards their respective aircraft. Filled with expectation and mild trepidation they stepped into the unknown… the ABC fellowship of 2012.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 8 - 8
1 May 2012
Sonnabend D
Full Access

Thirty years ago, rotator cuff surgery was exceedingly uncommon and shoulder arthroplasty almost unknown. Surgery for shoulder instability was largely empirical, non-anatomical and frequently unsuccessful. With the help of arthroscopy and MR scanning, a complex array of labral, ligament and tendon pathologies can now be recognised and treated, precisely and predictably. Anatomy-restoring arthroscopic techniques have largely replaced open stabilisation surgery. As life expectancy rises and citizens remain active into their seventh and eighth decades, the call for rotator cuff surgery has risen dramatically. Complex tendon transfers have expanded the indications for cuff surgery. Open repair has in part been supplanted by increasingly sophisticated arthroscopic techniques. The potential use of orthobiologics and stem cells promises further advances in the foreseeable future. Following the successful development of humeral hemiarthroplasty, and later of total shoulder replacement, surgical techniques and clinical indications for arthroplasty are now well refined. Predictable outcomes have been further enhanced by the present generation of ‘anatomic’ prostheses. More recently, the ‘rediscovery’ and improvement of semi-constrained (reverse) prostheses has transformed the previously dismal outlook for sufferers of cuff arthropathy and similar conditions. Many Australian Orthopaedic Association trainees undertake post-specialisation fellowships in shoulder surgery, both at home and abroad, and there is a steady flow of young overseas fellows through Australian shoulder units. The Shoulder and Elbow Society of Australia, founded in 1990 as a loose grouping of interested colleagues, now boasts over 70 active members. Australian surgeons and researchers are well represented in the prestigious Journal of Shoulder and Elbow Surgery and Australian shoulder surgery has come of age