Advertisement for orthosearch.org.uk
Results 1 - 20 of 341
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 66 - 66
14 Nov 2024
Tirta M Hjorth MH Jepsen JF Kold S Rahbek O
Full Access

Introduction

Epiphysiodesis, defined as the process of closing the growth plate (physis), have been used for several years as a treatment option of cases where the predicted leg-length discrepancy (LLD) falls between 2 to 5 cm. The aim of this study was to systematically review the existing literature on the effectiveness of three different epiphysiodesis techniques with implant usage for the treatment of leg-length discrepancy in the pediatric population. The secondary aim was to address the reported complications of staples, tension-band plates (TBP) and percutaneous epiphysiodesis screws (PETS).

Method

This systematic review was performed according to PRISMA guidelines. We searched MEDLINE (PubMed), Embase, Cochrane Library, Web of Science and Scopus for studies on skeletally immature patients with LLD treated with epiphysiodesis with an implant. The extracted outcome categories were effectiveness of epiphysiodesis (LLD measurements pre/post-operatively, successful/unsuccessful) and complications that were graded on severity.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1182 - 1189
1 Oct 2024
Nisar S Lamb J Johansen A West R Pandit H

Aims

To determine if patient ethnicity among patients with a hip fracture influences the type of fracture, surgical care, and outcome.

Methods

This was an observational cohort study using a linked dataset combining data from the National Hip Fracture Database and Hospital Episode Statistics in England and Wales. Patients’ odds of dying at one year were modelled using logistic regression with adjustment for ethnicity and clinically relevant covariates.


Bone & Joint Open
Vol. 5, Issue 7 | Pages 581 - 591
12 Jul 2024
Wang W Xiong Z Huang D Li Y Huang Y Guo Y Andreacchio A Canavese F Chen S

Aims

To investigate the risk factors for unsuccessful radial head reduction (RHR) in children with chronic Monteggia fractures (CMFs) treated surgically.

Methods

A total of 209 children (mean age 6.84 years (SD 2.87)), who underwent surgical treatment for CMFs between March 2015 and March 2023 at six institutions, were retrospectively reviewed. Assessed risk factors included age, sex, laterality, dislocation direction and distance, preoperative proximal radial metaphysis width, time from injury to surgery, reduction method, annular ligament reconstruction, radiocapitellar joint fixation, ulnar osteotomy, site of ulnar osteotomy, preoperative and postoperative ulnar angulation, ulnar fixation method, progressive ulnar distraction, and postoperative cast immobilization. Independent-samples t-test, chi-squared test, and logistic regression analysis were used to identify the risk factors associated with unsuccessful RHR.


Bone & Joint Open
Vol. 5, Issue 7 | Pages 570 - 580
10 Jul 2024
Poursalehian M Ghaderpanah R Bagheri N Mortazavi SMJ

Aims

To systematically review the predominant complication rates and changes to patient-reported outcome measures (PROMs) following osteochondral allograft (OCA) transplantation for shoulder instability.

Methods

This systematic review, following PRISMA guidelines and registered in PROSPERO, involved a comprehensive literature search using PubMed, Embase, Web of Science, and Scopus. Key search terms included “allograft”, “shoulder”, “humerus”, and “glenoid”. The review encompassed 37 studies with 456 patients, focusing on primary outcomes like failure rates and secondary outcomes such as PROMs and functional test results.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 82 - 88
1 May 2024
Villa JM Rajschmir K Hosseinzadeh S Manrique-Succar J Grieco P Higuera-Rueda CA Riesgo AM

Aims. Large bone defects resulting from osteolysis, fractures, osteomyelitis, or metastases pose significant challenges in acetabular reconstruction for total hip arthroplasty. This study aimed to evaluate the survival and radiological outcomes of an acetabular reconstruction technique in patients at high risk of reconstruction failure (i.e. periprosthetic joint infection (PJI), poor bone stock, immunosuppressed patients), referred to as Hip Reconstruction In Situ with Screws and Cement (HiRISC). This involves a polyethylene liner embedded in cement-filled bone defects reinforced with screws and/or plates for enhanced fixation. Methods. A retrospective chart review of 59 consecutive acetabular reconstructions was performed by four surgeons in a single institution from 18 October 2018 to 5 January 2023. Cases were classified based on the Paprosky classification, excluding type 1 cases (n = 26) and including types 2 or 3 for analysis (n = 33). Radiological loosening was evaluated by an orthopaedic surgeon who was not the operating surgeon, by comparing the immediate postoperative radiographs with the ones at latest follow-up. Mean follow-up was 557 days (SD 441; 31 to 1,707). Results. Out of the 33 cases analyzed, six (18.2%) constructs required revision, with four revisions due to uncontrolled infection, one for dislocation, and one for aseptic loosening. Among the 27 non-revised constructs, only one showed wider radiolucencies compared to immediate postoperative radiographs, indicating potential loosening. Patients who underwent revision (n = 6) were significantly younger and had a higher BMI compared to those with non-revised constructs (p = 0.016 and p = 0.026, respectively). Sex, race, ethnicity, American Society of Anesthesiologists grade, infection status (patients with postoperative PJI diagnosis (septic) vs patients without such diagnosis (aseptic)), and mean follow-up did not significantly differ between revised and non-revised groups. Conclusion. The HiRISC technique may serve as a feasible short-term (about one to two years) alternative in patients with large acetabular defects, particularly in cases of PJI. Longer follow-up is necessary to establish the long-term survival of this technique. Cite this article: Bone Joint J 2024;106-B(5 Supple B):82–88


Bone & Joint Open
Vol. 5, Issue 4 | Pages 286 - 293
9 Apr 2024
Upadhyay PK Kumar V Mirza SB Shah N

Aims

This study reports the results of 38 total hip arthroplasties (THAs) in 33 patients aged less than 50 years, using the JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component.

Methods

We describe the survival, radiological, and functional outcomes of 33 patients (38 THAs) at a mean follow-up of 27 years (25 to 32) between 1988 and 2018.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 359 - 364
1 Apr 2024
Özdemir E de Lange B Buckens CFM Rijnen WHC Visser J

Aims

To investigate the extent of bone development around the scaffold of custom triflange acetabular components (CTACs) over time.

Methods

We performed a single-centre historical prospective cohort study, including all patients with revision THA using the aMace CTAC between January 2017 and March 2021. A total of 18 patients (18 CTACs) were included. Models of the hemipelvis and the scaffold component of the CTACs were created by segmentation of CT scans. The CT scans were performed immediately postoperatively and at least one year after surgery. The amount of bone in contact with the scaffold was analyzed at both times, and the difference was calculated.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims

Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery.

Methods

A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group.


Bone & Joint Research
Vol. 13, Issue 1 | Pages 40 - 51
11 Jan 2024
Lin J Suo J Bao B Wei H Gao T Zhu H Zheng X

Aims

To investigate the efficacy of ethylenediaminetetraacetic acid-normal saline (EDTA-NS) in dispersing biofilms and reducing bacterial infections.

Methods

EDTA-NS solutions were irrigated at different durations (1, 5, 10, and 30 minutes) and concentrations (1, 2, 5, 10, and 50 mM) to disrupt Staphylococcus aureus biofilms on Matrigel-coated glass and two materials widely used in orthopaedic implants (Ti-6Al-4V and highly cross-linked polyethylene (HXLPE)). To assess the efficacy of biofilm dispersion, crystal violet staining biofilm assay and colony counting after sonification and culturing were performed. The results were further confirmed and visualized by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). We then investigated the efficacies of EDTA-NS irrigation in vivo in rat and pig models of biofilm-associated infection.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 24 - 24
2 Jan 2024
Burgos J Mariscal G Antón-Rodrigálvarez L Sanpera I Hevia E García V Barrios C
Full Access

The aim of this study was to report the restauration of the normal vertebral morphology and the absence of curve progression after removal the instrumentation in AIS patients that underwent posterior correction of the deformity by common all screws construct whitout fusion. A series of 36 AIS immature patients (Risser 3 or less) were include in the study. Instrumentation was removed once the maturity stage was complete (Risser 5). Curve correction was assessed at pre and postoperative, before instrumentation removal, just post removal, and more than two years after instrumentation removal. Epiphyseal vertebral growth modulation was assessed by a coronal wedging ratio (WR) at the apical level of the main curve (MC). The mean preoperative coronal Cobb was corrected from 53.7°±7.5 to 5.5º±7.5º (89.7%) at the immediate postop. After implants removal (31.0±5.8 months) the MC was 13.1º. T5–T12 kyphosis showed a significant improvement from 19.0º before curve correction to 27.1º after implants removal (p<0.05). Before surgery, WR was 0.71±0.06, and after removal WR was 0.98±0.08 (p<0.001). At the end of follow-up, the mean sagittal range of motion (ROM) of the T12-S1 segment was 51.2±21.0º. SRS-22 scores improved from 3.31±0.25 preoperatively to 3.68±0.25 at final assessment (p<0.001). In conclusion, fusionless posterior approach using a common all pedicle screws construct correct satisfactory scoliotic main curves and permits removal of the instrumentation once the bone maturity is reached. The final correction was highly satisfactory and an acceptable ROM of the previously lower instrumented segments was observed.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 26 - 26
2 Jan 2024
Jacob A Heumann M Zderic I Varga P Caspar J Lauterborn S Haschtmann D Fekete T Gueorguiev B Loibl M
Full Access

Stand-alone anterior lumbar interbody fusion (ALIF) provides the opportunity to avoid supplemental posterior fixation. This may reduce morbidity and complication rate, which is of special interest in patients with reduced bone mineral density (BMD). This study aims to assess immediate biomechanical stability and radiographic outcome of a stand-alone ALIF device with integrated screws in specimens of low BMD.

Eight human cadaveric spines (L4-sacrum) were instrumented with SynFix-LR™ (DePuy Synthes) at L5/S1. Quantitative computed tomography was used to measure BMD of L5 in AMIRA. Threshold values proposed by the American Society of Radiology 80 and 120 mg CaHa/mL were used to differentiate between Osteoporosis, Osteopenia, and normal BMD. Segmental lordosis, anterior and posterior disc height were analysed on pre- and postoperative radiographs (Fig 1). Specimens were tested intact and following instrumentation using a flexibility protocol consisting of three loading cycles to ±7.5 Nm in flexion-extension, lateral bending, and axial rotation. The ranges of motion (ROM) of the index level were assessed using an optoelectronic system.

BMD ranged 58–181mg CaHA/mL. Comparison of pre- and postoperative radiographs revealed significant increase of L5/S1 segmental lordosis (mean 14.6°, SD 5.1, p < 0.001) and anterior disc height (mean 5.8mm, SD 1.8, p < 0.001), but not posterior disc height. ROM of 6 specimens was reduced compared to the intact state. Two specimens showed destructive failure in extension. Mean decrease was most distinct in axial rotation up to 83% followed by flexion-extension.

ALIF device with integrated screws at L5/S1 significantly increases segmental lordosis and anterior disc height without correlation to BMD. Primary stability in the immediate postoperative situation is mostly warranted in axial rotation. The risk of failure might be increased in extension for some patients with reduced lumbar BMD, therefore additional posterior stabilization could be considered.

For any figures or tables, please contact the authors directly.


Bone & Joint Open
Vol. 4, Issue 12 | Pages 957 - 963
18 Dec 2023
van den Heuvel S Penning D Sanders F van Veen R Sosef N van Dijkman B Schepers T

Aims

The primary aim of this study was to present the mid-term follow-up of a multicentre randomized controlled trial (RCT) which compared the functional outcome following routine removal (RR) to the outcome following on-demand removal (ODR) of the syndesmotic screw (SS).

Methods

All patients included in the ‘ROutine vs on DEmand removal Of the syndesmotic screw’ (RODEO) trial received the Olerud-Molander Ankle Score (OMAS), American Orthopaedic Foot and Ankle Hindfoot Score (AOFAS), Foot and Ankle Outcome Score (FAOS), and EuroQol five-dimension questionnaire (EQ-5D). Out of the 152 patients, 109 (71.7%) completed the mid-term follow-up questionnaire and were included in this study (53 treated with RR and 56 with ODR). Median follow-up was 50 months (interquartile range 43.0 to 56.0) since the initial surgical treatment of the acute syndesmotic injury. The primary outcome of this study consisted of the OMAS scores of the two groups.


Bone & Joint 360
Vol. 12, Issue 6 | Pages 24 - 27
1 Dec 2023

The December 2023 Foot & Ankle Roundup360 looks at: Subchondral bone cysts remodel after correction of varus deformity in ankle arthritis; 3D-printed modular endoprosthesis reconstruction following total calcanectomy; Percutaneous partial bone excision in the management of diabetic toe osteomyelitis; Hemiepiphysiodesis is a viable surgical option for Juvenile hallux valgus; Ankle arthroplasty vs arthrodesis: which comes out on top?; Patient-related risk factors for poorer outcome following total ankle arthroplasty; The Outcomes in Ankle Replacement Study.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1078 - 1085
1 Oct 2023
Cance N Batailler C Shatrov J Canetti R Servien E Lustig S

Aims

Tibial tubercle osteotomy (TTO) facilitates surgical exposure and protects the extensor mechanism during revision total knee arthroplasty (rTKA). The purpose of this study was to determine the rates of bony union, complications, and reoperations following TTO during rTKA, to assess the functional outcomes of rTKA with TTO at two years’ minimum follow-up, and to identify the risk factors of failure.

Methods

Between January 2010 and September 2020, 695 rTKAs were performed and data were entered into a prospective database. Inclusion criteria were rTKAs with concomitant TTO, without extensor mechanism allograft, and a minimum of two years’ follow-up. A total of 135 rTKAs were included, with a mean age of 65 years (SD 9.0) and a mean BMI of 29.8 kg/m2 (SD 5.7). The most frequent indications for revision were infection (50%; 68/135), aseptic loosening (25%; 34/135), and stiffness (13%; 18/135). Patients had standardized follow-up at six weeks, three months, six months, and annually thereafter. Complications and revisions were evaluated at the last follow-up. Functional outcomes were assessed using the Knee Society Score (KSS) and range of motion.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 79 - 79
7 Aug 2023
Houston J Everett S Choudhary A Middleton S Mandalia V
Full Access

Abstract

Introduction

Symptomatic osteochondritis dissecans (OCD) and traumatic osteochondral fractures (OCF) are treated with fixation with either metal or bioabsorbable device. We performed a comparative review of patients with OCD and traumatic OCF stabilised with Bio-Compression screws which are headless absorbable compression screws. Our aim was to determine whether there was a difference in outcomes between presentations.

Methods

Retrospective single-centre cohort study of all patients with OCD and OCF treated with Bio-Compression screw between July 2017 and September 2022. All patients followed up until discharge with satisfactory clinical outcome. Primary outcome was return to theatre for ongoing pain or mechanical symptoms. Secondary outcome was evidence of fixation failure on follow-up MRI scan.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 5 - 5
23 Jun 2023
Higuera CA Villa JM Rajschmir K Grieco P Manrique-Succar J Riesgo AM
Full Access

Osteolysis, fractures, and bone destruction caused by osteomyelitis or metastasis can cause large bone defects and present major challenges during acetabular reconstruction in total hip arthroplasty. We sought to evaluate the survivorship and radiographic outcomes of an acetabular reconstruction consisting of a polyethylene liner (semi-constrained) embedded in cement filling bone defect(s) reinforced with screws and/or plates for enhanced fixation (HiRISC).

Retrospective chart review of 59 consecutive acetabular reconstructions as described above performed by 4 surgeons in a single institution (10/18/2018-1/5/2023) was performed. After radiographs and operative reports were reviewed, cases were classified following the Paprosky classification for acetabular defects. Paprosky type 1 cases (n=26) were excluded, while types 2/3 (n=33) were included for analysis. Radiographic loosening was evaluated up to latest follow-up. Mean follow-up was: 487 days (range, 20–1,539 days).

Out of 33 cases, 2 (6.1%) cases were oncological (metastatic disease) and 22 (66.7%) had deep infection diagnosis (i.e., periprosthetic joint infection [PJI] or septic arthritis). In total, 7 (21.2%) reconstructions were performed on native acetabula (3 septic, 4 aseptic). At a mean follow-up of 1.3 years, 5 (15.2%) constructs were revised: 4 due to uncontrolled infection (spacer exchange) and 1 for instability. On follow-up radiographs, only 1 non-revised construct showed increased radiolucencies, but no obvious loosening. When compared to patients with non-revised constructs, those who underwent revision (n=5) were significantly younger (mean 73.8 vs. 60.6 years, p=0.040) and had higher body mass index (24.1 vs. 31.0 Kg/m2, p=0.045), respectively. Sex, race, ethnicity, American-Society-of-Anesthesiologist classification, infection diagnosis status (septic/aseptic), and mean follow-up (449.3 vs. 695.6 days, respectively, p=0.189) were not significantly different between both groups.

HiRISC construct may be a viable short-term alternative to more expensive implants to treat large acetabular defects, particularly in the setting of PJI. Longer follow up is needed to establish long term survivorship.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 543 - 550
1 May 2023
Abel F Avrumova F Goldman SN Abjornson C Lebl DR

Aims

The aim of this study was to assess the accuracy of pedicle screw placement, as well as intraoperative factors, radiation exposure, and complication rates in adult patients with degenerative disorders of the thoracic and lumbar spines who have undergone robotic-navigated spinal surgery using a contemporary system.

Methods

The authors reviewed the prospectively collected data on 196 adult patients who had pedicle screws implanted with robot-navigated assistance (RNA) using the Mazor X Stealth system between June 2019 and March 2022. Pedicle screws were implanted by one experienced spinal surgeon after completion of a learning period. The accuracy of pedicle screw placement was determined using intraoperative 3D fluoroscopy.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 43 - 43
11 Apr 2023
Amirouche F Mok J Leonardo Diaz R Forsthoefel C Hussain A
Full Access

Lateral lumbar interbody fusion (LLIF) has biomechanical advantages due to the preservation of ligamentous structures (ALL/PLL), and optimal cage height afforded by the strength of the apophyseal ring. We compare the biomechanical motion stability of multiple levels LLIF (4 segments) utilising PEEK interbody 26mm cages to stand-alone cage placement and with supplemental posterior fixation with pedicle screw and rods.

Six lumbar human cadaver specimens were stripped of the paraspinal musculature while preserving the discs, facet joints, and osteoligamentous structures and potted. Specimens were tested under 5 conditions: intact, posterior bilateral fixation (L1-L5) only, LLIF-only, LLIF with unilateral fixation and LLIF with bilateral fixation. Non-destructive testing was performed on a universal testing machine (MTS Systems Corp) to produce flexion-extension, lateral-bending, and axial rotation using customized jigs and a pulley system to define a non-constraining load follower. Three-dimensional spine motion was recorded using a motion device (Optotrak).

Results are reported for the L3-L4 motion segment within the construct to allow comparison with previously published works of shorter constructs (1-2 segments). In all conditions, there was an observed decrease in ROM from intact in flexion/extension (31%-89% decrease), lateral bending (19%-78%), and axial rotation (37%-60%). At flexion/extension, the decreases were statistically significant (p<0.007) except for stand-alone LLIF. LLIF+unilateral had similar decreases in all planes as the LLIF+bilateral condition. The observed ROM within the 4-level construct was similar to previously reported results in 1-2 levels for stand-alone LLIF and LLIF+bilateral.

Surgeons may be concerned about the biomechanical stability of an approach utilizing stand-alone multilevel LLIF. Our results show that 4-level multilevel LLIF utilizing 26 mm cages demonstrated ROM comparable to short-segment LLIF. Stand-alone LLIF showed a decrease in ROM from the intact condition. The addition of posterior supplemental fixation resulted in an additional decrease in ROM. The results suggest that unilateral posterior fixation may be sufficient.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 5 - 5
4 Apr 2023
Vicary-Watts R McLauchlan G
Full Access

Cannulated hip screws are frequently used in the management of hip fractures. There have been concerns over the failure rate of the technique and the outcomes of those that subsequently require conversion to total hip replacement (THR).

This study utilised a database of over 600 cannulated hip screw (CHS) fixations performed over a 14-year period and followed up for a minimum of one year (1-14). We identified 57 cases where a conversion to THR took place (40 females, 17 males, mean age: 71.2 years). Patient demographics, original mechanism of injury, fracture classification, reason for fixation failure, time until arthroplasty, implant type and post-arthroplasty complications were recorded. Clinical outcomes were measured using the Oxford Hip Score.

The failure rate of cannulated screw treatment was 9.4% and the mean time from initial fixation to arthroplasty was 15.4 (16.5) months. Thirty six fractures were initially undisplaced and 21 were displaced. As one might expect the displaced cases tended to be younger but this didn't reach statistical significance [66.5(14.3) vs 72.7(13.1), p=0.1]. The commonest causes of failure were non-union (25 cases, 44%) and avascular necrosis (17 cases, 30%). Complications after THR consisted of one leg length discrepancy and one peri-prosthetic fracture. The mean Oxford score pre-arthroplasty was 12.2 (8.4), improving to 38.4 (11.1) at one-year. Although the pre op Oxford scores tended to be lower in patients with undisplaced fractures and higher ASA scores, the improvement was the same whatever the pre-op situation. The one-year Oxford score and the improvement in score are comparable to those seen in the literature for THR in general.

In conclusion, CHS has a high success rate and where salvage arthroplasty is required it can provide good clinical outcomes with low complication rates.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 72 - 72
4 Apr 2023
Silva-Henao J Pahr DH Reisinger A
Full Access

Primary implant stability is critical for osseointegration and subsequent implant success. Small displacements on the screw/bone interface are necessary for implant success, however, larger displacements can propagate cracks and break anchorage points which causes the screw to fail. Limited information is available on the progressive degradation of stability of an implanted bone screw since most published research is based on monotonic, quasi-static loading [1]. This study aims to address this gap in knowledge. A total of 100 implanted trabecular screws were tested using multi-axial loading test set-up. Screws were loaded in cycles with the applied force increasing 1N in each load cycle. In every load cycle, Peak forces, displacements, and stiffness degradation (calculated in the unloading half of the cycle) where recorded. 10 different loading configurations where tested. The damage vs displacement shows a total displacement at the point of failure between 0.3 and 0.4 mm while an initial stiffness reduction close to 40%. It is also shown that at a displacement of ~0.1 mm, the initial stiffness of every sample had degraded by 20% (or more) meaning that half of the allowable degradation occurred in the first 25-30% of the total displacement. Other studies on screw overloading [1] suggests similar results to our concerning initial stiffness degradation at the end of the loading cycle. Our results also show that the initial stiffness degrades faster with relatively small deformations suggesting that the failure point of an implanted screw might occur before the common failure definition (pull-out force, for example). These results are of great significance since primary implant stability is better explained by the stiffness of the construct than by its failure point