Advertisement for orthosearch.org.uk
Results 1 - 20 of 70
Results per page:
Bone & Joint Open
Vol. 4, Issue 2 | Pages 79 - 86
10 Feb 2023
McLaughlin JR Johnson MA Lee KR

Aims

The purpose of this study is to report our updated results at a minimum follow-up of 30 years using a first generation uncemented tapered femoral component in primary total hip arthroplasty (THA).

Methods

The original cohort consisted of 145 consecutive THAs performed by a single surgeon in 138 patients. A total of 37 patients (40 hips) survived a minimum of 30 years, and are the focus of this review. The femoral component used in all cases was a first-generation Taperloc with a non-modular 28 mm femoral head. Clinical follow-up at a minimum of 30 years was obtained on every living patient. Radiological follow-up at 30 years was obtained on all but four.


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 559 - 566
1 May 2022
Burden EG Batten T Smith C Evans JP

Aims

Arthroplasty is being increasingly used for the management of distal humeral fractures (DHFs) in elderly patients. Arthroplasty options include total elbow arthroplasty (TEA) and hemiarthroplasty (HA); both have unique complications and there is not yet a consensus on which implant is superior. This systematic review asked: in patients aged over 65 years with unreconstructable DHFs, what differences are there in outcomes, as measured by patient-reported outcome measures (PROMs), range of motion (ROM), and complications, between distal humeral HA and TEA?

Methods

A systematic review of the literature was performed via a search of MEDLINE and Embase. Two reviewers extracted data on PROMs, ROM, and complications. PROMs and ROM results were reported descriptively and a meta-analysis of complications was conducted. Quality of methodology was assessed using Wylde’s non-summative four-point system. The study was registered with PROSPERO (CRD42021228329).


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1206 - 1214
1 Jul 2021
Tsikandylakis G Mortensen KRL Gromov K Mohaddes M Malchau H Troelsen A

Aims

We aimed to investigate if the use of the largest possible cobalt-chromium head articulating with polyethylene acetabular inserts would increase the in vivo wear rate in total hip arthroplasty.

Methods

In a single-blinded randomized controlled trial, 96 patients (43 females), at a median age of 63 years (interquartile range (IQR) 57 to 69), were allocated to receive either the largest possible modular femoral head (36 mm to 44 mm) in the thinnest possible insert or a standard 32 mm head. All patients received a vitamin E-doped cross-linked polyethylene insert and a cobalt-chromium head. The primary outcome was proximal head penetration measured with radiostereometric analysis (RSA) at two years. Secondary outcomes were volumetric wear, periacetabular radiolucencies, and patient-reported outcomes.


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 25 - 32
1 Jul 2021
Amstutz HC Le Duff MJ

Aims

Adverse local tissue reactions associated with abnormal wear considerably slowed down the general use of metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), now limited to a few specialized centres. In this study, we provide the clinical results of 400 consecutive MoM HRAs implanted more than 20 years ago in one such centre.

Methods

A total of 355 patients (400 hips) were treated with Conserve Plus HRA between November 1996 and November 2000. There were 96 female (27%) and 259 male patients (73%). Their mean age was 48.2 years (SD 10.9). The University of California, Los Angeles (UCLA) hip scores and 12-item Short Form Survey (SF-12) quality of life scores were reported. Survivorship was assessed using Kaplan-Meier analyses.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1270 - 1276
1 Jul 2021
Townshend DN Bing AJF Clough TM Sharpe IT Goldberg A

Aims

This is a multicentre, non-inventor, prospective observational study of 503 INFINITY fixed bearing total ankle arthroplasties (TAAs). We report our early experience, complications, and radiological and functional outcomes.

Methods

Patients were recruited from 11 specialist centres between June 2016 and November 2019. Demographic, radiological, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Questionnaire, and EuroQol five-dimension five-level score) were collected preoperatively, at six months, one year, and two years. The Canadian Orthopaedic Foot and Ankle Society (COFAS) grading system was used to stratify deformity. Early and late complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts, and/or subsidence.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 150 - 157
1 Jun 2021
Anderson LA Christie M Blackburn BE Mahan C Earl C Pelt CE Peters CL Gililland J

Aims

Porous metaphyseal cones can be used for fixation in revision total knee arthroplasty (rTKA) and complex TKAs. This metaphyseal fixation has led to some surgeons using shorter cemented stems instead of diaphyseal engaging cementless stems with a potential benefit of ease of obtaining proper alignment without being beholden to the diaphysis. The purpose of this study was to evaluate short term clinical and radiographic outcomes of a series of TKA cases performed using 3D-printed metaphyseal cones.

Methods

A retrospective review of 86 rTKAs and nine complex primary TKAs, with an average age of 63.2 years (SD 8.2) and BMI of 34.0 kg/m2 (SD 8.7), in which metaphyseal cones were used for both femoral and tibial fixation were compared for their knee alignment based on the type of stem used. Overall, 22 knees had cementless stems on both sides, 52 had cemented stems on both sides, and 15 had mixed stems. Postoperative long-standing radiographs were evaluated for coronal and sagittal plane alignment. Adjusted logistic regression models were run to assess malalignment hip-knee-ankle (HKA) alignment beyond ± 3° and sagittal alignment of the tibial and femoral components ± 3° by stem type.


Bone & Joint Open
Vol. 2, Issue 1 | Pages 33 - 39
14 Jan 2021
McLaughlin JR Lee KR Johnson MA

Aims

We present the clinical and radiological results at a minimum follow-up of 20 years using a second-generation uncemented total hip arthroplasty (THA). These results are compared to our previously published results using a first-generation hip arthroplasty followed for 20 years.

Methods

A total of 62 uncemented THAs in 60 patients were performed between 1993 and 1994. The titanium femoral component used in all cases was a Taperloc with a reduced distal stem. The acetabular component was a fully porous coated threaded hemispheric titanium shell (T-Tap ST). The outcome of every femoral and acetabular component with regard to retention or revision was determined for all 62 THAs. Complete clinical follow-up at a minimum of 20 years was obtained on every living patient. Radiological follow-up was obtained on all but one.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 21 - 21
1 Oct 2020
Amstutz HC Le Duff MJ
Full Access

Background. Hip resurfacing arthoplasty (HRA) showed promising early and mid-terms results at the beginning of the new millennium. Adverse local tissue reactions associated with metal debris considerably slowed down the implantation of HRA which use is now limited to a few specialized centers. The long term success of this procedure, however, is still largely unknown. This study aimed to provide the clinical results of a series of 400 consecutive HRA with a minimum follow-up of 20 years. Methods. All patients treated with Conserve. ®. Plus HRA between November 1996 and November 2000 were retrospectively selected and 355 patients (400 hips) were included. The clinical results of this series was previously reported in 2004 at a follow up of 2 to 6 years[1]. There were 96 women (27%) and 259 men (73%). Mean age at surgery was 48.2 ± 10.9 years. Long-term survivorship was assessed with Kaplan-Meier survival estimates. UCLA hip scores and SF-12 quality of life scores were collected at follow-up visits. Radiographic positioning of the acetabular component was assessed with the computation of the contact patch to rim (CPR) distance. Radiolucencies about the metaphyseal stem and around the acetabular component were recorded to assess the quality of the component fixation. Results. The mean time of follow up was 16.3 ± 5.5 years including 183 hips beyond 20 yrs. Nine hips were lost to follow up (2.2%) Thirty-three patients (35 hips,8.8%) died of causes unrelated to the surgery at a mean 11.9 ± 5.3 years after surgery The mean UCLA hip scores at last follow-up were 9.3 ± 1.0, 9.1 ± 1.4, 9.0 ± 1.8, and 6.9 ± 1.7 for pain, walking, function, and activity, respectively. Post-operative SF-12 scores were 48.4 ± 10.3 for the physical component and 48.5 ± 15.5 for the mental component and did not differ from those of the general US population. Fifty-five patients (60 hips) underwent revision surgery at a mean time of 9.3 ± 5.8 years. Indications for revision surgery included acetabular component loosening (12 hips), femoral component loosening (31 hips), femoral neck fracture (6 hips), wear (6 hips), sepsis (2 hips), recurrent dislocations (1 hip), acetabular component protrusion after over-reaming (1 hip) and unknown (1 hip which was revised in another center). Using any revision as an endpoint, the Kaplan-Meier survivorship was 95.2% at 5 years, 91.2% at 10 years, 87.3% at 15 years, and 83.2% at 20 years. A multivariate model for risk factor analysis showed a diagnosis of developmental dysplasia (p=0.020) and a low body mass index (typically associated with higher levels of activity) (p=0.032), to be significantly related to revision for any reason. Female sex was not a risk factor after adjustment for hip dysplasia and component size was made (Table 1). There was only 1 femoral failure (a late neck fracture 19 years after surgery) among the hips reconstructed with a cemented metaphyseal stem (n=59). Five of the 6 hips (1.5%) with wear-related failures all had mal-positioned sockets (CPR distance <10mm) and were therefore preventable. There were no cases with a high score of aseptic lymphocytic vasculitis-associated lesions (ALVAL)[2], suggesting metal sensitivity. X-ray analysis showed excellent persisting fixation in all but one hip. Conclusions. In this group of patients operated over 20 years ago, HRA keeps providing excellent pain relief and quality of life to the patients. Subsequent progress in the preparation of the femoral head has considerably reduced the failure rate on the femoral side which was the main mode of failure in this initial series[3, 4]. The 83.1% 20 year survivorship of this initial series surpasses that of total hip arthroplasties in use 20 years ago in this young patient population[5]. Life-long durability of the device is anticipated for most of the remaining patients. The established benefits of this procedure, such as a low dislocation rate, an anatomic reconstruction with physiologic loading of the proximal femur, the absence of taper corrosion, and an easy conversion if ever necessary, make HRA a preferable alternative to THA in young and active patients. For any figures, tables, or references, please contact the authors directly


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1158 - 1166
14 Sep 2020
Kaptein BL den Hollander P Thomassen B Fiocco M Nelissen RGHH

Aims. The primary objective of this study was to compare migration of the cemented ATTUNE fixed bearing cruciate retaining tibial component with the cemented Press-Fit Condylar (PFC)-sigma fixed bearing cruciate retaining tibial component. The secondary objectives included comparing clinical and radiological outcomes and Patient Reported Outcome Measures (PROMs). Methods. A single blinded randomized, non-inferiority study was conducted including 74 patients. Radiostereometry examinations were made after weight bearing, but before hospital discharge, and at three, six, 12, and 24 months postoperatively. PROMS were collected preoperatively and at three, six, 12, and 24 months postoperatively. Radiographs for measuring radiolucencies were collected at two weeks and two years postoperatively. Results. The overall migration (mean maximum total point motion (MPTM)) at two years was comparable: mean 1.13 mm (95% confidence interval (CI), 0.97 to 1.30) for the ATTUNE and 1.16 mm (95% CI, 0.99 to 1.35) for the PFC-sigma. At two years, the mean backward tilting was -0.43° (95% CI, -0.65 to -0.21) for the ATTUNE and 0.08° (95% CI -0.16 to 0.31), for the PFC-sigma. Overall migration between the first and second postoperative year was negligible for both components. The clinical outcomes and PROMs improved compared with preoperative scores and were not different between groups. Radiolucencies at the implant-cement interface were mainly seen below the medial baseplate: 17% in the ATTUNE and 3% in the PFC-sigma at two weeks, and at two years 42% and 9% respectively (p = 0.001). Conclusion. In the first two postoperative years the initial version of the ATTUNE tibial component was not inferior with respect to overall migration, although it showed relatively more backwards tilting and radiolucent lines at the implant-cement interface than the PFC-sigma. The version of the ATTUNE tibial component examined in this study has subsequently undergone modification by the manufacturer. Level of Evidence: 1 (randomized controlled clinical trial). Cite this article: Bone Joint J 2020;102-B(9):1158–1166


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 123 - 128
1 Jun 2020
Martin JR Geary MB Ransone M Macknet D Fehring K Fehring T

Aims

Aseptic loosening of the tibial component is a frequent cause of failure in primary total knee arthroplasty (TKA). Management options include an isolated tibial revision or full component revision. A full component revision is frequently selected by surgeons unfamiliar with the existing implant or who simply wish to “start again”. This option adds morbidity compared with an isolated tibial revision. While isolated tibial revision has a lower morbidity, it is technically more challenging due to difficulties with exposure and maintaining prosthetic stability. This study was designed to compare these two reconstructive options.

Methods

Patients undergoing revision TKA for isolated aseptic tibial loosening between 2012 and 2017 were identified. Those with revision implants or revised for infection, instability, osteolysis, or femoral component loosening were excluded. A total of 164 patients were included; 88 had an isolated tibial revision and 76 had revision of both components despite only having a loose tibial component. The demographics and clinical and radiological outcomes were recorded.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1592 - 1599
1 Dec 2018
Galea VP Connelly JW Shareghi B Kärrholm J Sköldenberg O Salemyr M Laursen MB Muratoglu O Bragdon C Malchau H

Aims

The primary aim of this study was to compare the wear properties of vitamin E-diffused, highly crosslinked polyethylene (VEPE) and one formulation of moderately crosslinked and mechanically annealed ultra-high molecular weight polyethylene (ModXLPE) in patients five years after primary total hip arthroplasty (THA). The secondary aim was to assess the clinical results of patients treated with VEPE by evaluating patient-reported outcome measures (PROMs), radiological evidence of fixation, and the incidence of mechanical failure.

Patients and Methods

A total of 208 patients (221 THAs) from four international centres were recruited into a prospective study involving radiostereometric analysis (RSA) and the assessment of clinical outcomes. A total of 193 hips (87%) were reviewed at the five-year follow-up. Of these, 136 (70%) received VEPE (vs ModXLPE) liners and 68 (35%) received ceramic (vs metal) femoral heads. PROMs and radiographs were collected preoperatively and at one, two, and five years postoperatively. In addition, RSA images were collected to measure PE wear postoperatively and at one, two, and five years after surgery.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 75 - 75
1 Oct 2018
Robinson RP Summers S
Full Access

Introduction. Modularity in femoral stem designs allow surgeons to independently control leg length, offset, and femoral version in revision or complex primary THA cases. Initial enthusiasm in these modular stems has been tempered by recognition of modular junction failures. This study evaluates mean 5-year clinical results and survival rates of a 3-part titanium alloy modular femoral implant with unique taper geometries and a metaphyseal plasma spray surface. The current results are presented after pre-market independent fatigue testing performed by Orthopaedic Laboratory (Greenwald) and previously published early clinical results in 2006. Low plasticity burnishing (LPB) was added in 2005 to further strengthen the neck metaphyseal modular junction. The modular stem component is a polished cylindrical splined clothespin design. Our hypothesis is that these unique modular junctions succeed in offering the advantages of modularity without failure at this midterm follow-up period. Methods. Between May 2010 and July 2016, 32 total hip arthroplasties were performed using a 3-part femoral stem with neck-metaphyseal-stem modular junctions. Surgeries were either the final stage of a two-stage revision for infection, revision THR for loosening, or a revision of a previous non-prosthetic replacement procedure. Patients were entered into an IRB-approved registry and followed with x-rays, HHS, Oxford scores, and patient satisfaction scores. Patients who failed to return for routine follow-up were contacted by phone or email. Two patients had died with their implants intact. Six patients could not be reached for an updated follow-up. One stem was revised for loosening at 33 months due to failed osseointegration in a patient with chronic renal failure. This removed stem was submitted for taper exam and sectioning. Results. There were 23 patients for evaluation at a mean 61 months (range 21–98). Mean patient age at implantation was 56 (range 25–88), BMI was 27 (range 20–40). There were no modular junction failures. Modular junctions examined in the retrieved implant did not demonstrate any abnormalities other than normal wear properties. HHS and OHS scores both improved between pre-op and final follow-up, 23 to 85 and 17 to 43, respectively. Average patient satisfaction score at final follow-up was 9.8 out of 10 (min 8, max 10). Radiographic examination showed stem subsidence > 2mm and radiolucencies around the metaphyseal cone in 1 patient, the same patient who required implant removal. Radiolucencies were seen along the polished stem tip in 43% of cases, spot welding at the distal metaphyseal cone in 67% of cases, and mild proximal-medial stress shielding in 33% of cases. Conclusion. This unique 3-part modular stem with metaphyseal fixation shows good functional and radiographic results at 5-year follow-up. There were no junctional failures. One stem was removed due to failure to osseointegrate and showed no worrisome taper abnormalities. Spot welding is common around the plasma spray metaphyseal cone. Implant removal, if necessary, only requires disruption of the metaphyseal fixation. Further follow-up will be important to confirm our confidence in this unique stem design


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 170 - 175
1 Feb 2018
Lam Tin Cheung K Lanting BA McCalden RW Yuan X MacDonald SJ Naudie DD Teeter MG

Aims

The aim of this study was to evaluate the long-term inducible displacement of cemented tibial components ten years after total knee arthroplasty (TKA).

Patients and Methods

A total of 15 patients from a previously reported prospective trial of fixation using radiostereometric analysis (RSA) were examined at a mean of 11 years (10 to 11) postoperatively. Longitudinal supine RSA examinations were acquired at one week, one year, and two years postoperatively and at final follow-up. Weight-bearing RSA examinations were also undertaken with the operated lower limb in neutral and in maximum internal rotation positions. Maximum total point motion (MTPM) was calculated for the longitudinal and inducible displacement examinations (supine versus standing, standing versus internal rotation, and supine versus standing with internal rotation).


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1333 - 1341
1 Oct 2016
van der Voort P Valstar ER Kaptein BL Fiocco M van der Heide HJL Nelissen RGHH

Aims

The widely used and well-proven Palacos R (a.k.a. Refobacin Palacos R) bone cement is no longer commercially available and was superseded by Refobacin bone cement R and Palacos R + G in 2005. However, the performance of these newly introduced bone cements have not been tested in a phased evidence-based manner, including roentgen stereophotogrammetric analysis (RSA).

Patients and Methods

In this blinded, randomised, clinical RSA study, the migration of the Stanmore femoral component was compared between Refobacin bone cement R and Palacos R + G in 62 consecutive total hip arthroplasties. The primary outcome measure was femoral component migration measured using RSA and secondary outcomes were Harris hip score (HHS), Hip disability and Osteoarthritis Outcome Score (HOOS), EuroQol 5D (EQ-5D) and Short Form 36 (SF-36).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 70 - 70
1 May 2016
Carli A Warth L Nestor B
Full Access

Introduction

Cementless fixation is the current preferred method for acetabular reconstruction in total hip arthroplasty (THA). Despite promising long-term results among several designs, theoretic concerns regarding the high modulus of elasticity, low friction against bone and low volumetric porosity of contemporary cementless cups have spurred the introduction of novel porous surfaces that are designed to improve osseointegration and decrease aseptic loosening. Although several novel surfaces have been introduced into clinical use over the past decade, very little literature regarding their clinical and radiographic performance exists. The current study investigates the performance of one such novel surface, Tritanium (Stryker, Mahwah, NJ).

Methods

We prospectively evaluated 121 consecutive THAs performed in 94 patients by a single arthroplasty surgeon using the Tritanium Primary Acetabular Component (Stryker, Mahwah, NJ). 109 hips (90.1%) had adequate clinical and radiological follow-up for analysis. Clinical parameters recorded included implant survivorship, Harris Hip Scores, WOMAC and SF-12. Furthermore, radiographs at the 6-week, 1 year and most recent clinical visit were evaluated by two blinded observers for implant position, evidence of radiolucency, sclerosis and component migration.


Aims

To investigate the longevity of uncemented fixation of a femoral component in total hip arthroplasty (THA) in patients with Dorr type C proximal femoral morphology.

Patients and Methods

A total of 350 consecutive uncemented THA in 320 patients were performed between 1983 and 1987, by a single surgeon using the Taperloc femoral component. The 63 patients (68 hips) with Dorr type C proximal femoral morphology were the focus of this review. The mean age of the patients was 69 years (24 to 88) and mean follow-up was 16.6 years (ten to 29). Survival analysis included eight patients (eight hips) who died without undergoing revision surgery prior to obtaining ten years follow-up. All 55 surviving patients (60 hips) were available for clinical assessment and radiographic review. As a comparator group, the survival and implant fixation in the remaining 282 THAs (257 patients) with Dorr type A and B morphology were evaluated. The mean age of these patients was 52 years (20 to 82).


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 81 - 81
1 Dec 2015
Born P Ilchmann T Zwicky L Graber P Ochsner P Zimmerli W Clauss M
Full Access

To report mid-term results of PJI treated with uncemented stems. : 80 hips of PJI after THA were treated with uncemented stems from 01/1993 to 12/2012 and followed prospectively. Selection occurred for one- (n=27) or two-stage (n=53) exchange according to the Liestal algorithm. Surgical approaches were transfemoral (n=58), transgluteal (n=9) or transtrochanteric (n=13). A monoblock (Wagner SL, n=58) or modular (Revitan, n=22) revision stem was implanted. On the acetabular side 44 Müller rings, 33 Burch-Schneider cages (combined with a cemented PE-cup) and 3 press-fit cups were used. Kaplan-Meier survival was calculated for endpoints (a) persistence of infection, (b) septic/aseptic stem loosening. Radiographs were analysed for (a) subsidence, (b) distal stem integration, (c) changes in cortical thickness, (d) proximal femur restoration, (e) radiolucency around stem/cup. Mean FU was 5.2 (2–15) years. PJI was eradicated in 77 of 80 hips (96%). 3 patients (all two-stage) had a treatment failure. 2 were treated successfully with an additional two-stage exchange. In the 3rd patient we were not able to control infection and exarticulation was performed. Furthermore, one stem was revised for aseptic loosening (5 years), 1 for a broken Wagner stem (7 years) and 1 for subsidence (8 months). Stem survival after 5 years was 93% (SD ±2.5 years). 2 cups were revised for aseptic loosening and 1 for recurrent dislocations. Subsidence ≥5mm was found in 6 hips and occurred always within 3 months after surgery independent of stem type (p=0.947) and approach (p=0.691). Proximal femoral remodelling after transfemoral approach was excellent or good in 71% (32 excellent, 9 good) with no difference between one-/two-stage exchanges (p=0.288). Initial distal stem integration was 65mm medial and 66mm lateral and increased to 8mm medial (p=0.716) and 10mm lateral (p<0.001). Cortical thickness was unchanged over the entire FU period (p=0.493). Radiolucencies were seen around 26 stems, only the stem revised after 5years was rated loose. Eradication of PJI was high using our established protocol even with uncemented revision stems. Mid-term survival was independent from one-/two-stage revision and comparable to results for aseptic loosening revision


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1242 - 1249
1 Sep 2015
Hintermann B Wagener J Knupp M Schweizer C J. Schaefer D

Large osteochondral lesions (OCLs) of the shoulder of the talus cannot always be treated by traditional osteochondral autograft techniques because of their size, articular geometry and loss of an articular buttress. We hypothesised that they could be treated by transplantation of a vascularised corticoperiosteal graft from the ipsilateral medial femoral condyle.

Between 2004 and 2011, we carried out a prospective study of a consecutive series of 14 patients (five women, nine men; mean age 34.8 years, 20 to 54) who were treated for an OCL with a vascularised bone graft. Clinical outcome was assessed using a visual analogue scale (VAS) for pain and the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score. Radiological follow-up used plain radiographs and CT scans to assess graft incorporation and joint deterioration.

At a mean follow-up of 4.1 years (2 to 7), the mean VAS for pain had decreased from 5.8 (5 to 8) to 1.8 (0 to 4) (p = 0.001) and the mean AOFAS hindfoot score had increased from 65 (41 to 70) to 81 (54 to 92) (p = 0.003). Radiologically, the talar contour had been successfully reconstructed with stable incorporation of the vascularised corticoperiosteal graft in all patients. Joint degeneration was only seen in one ankle.

Treatment of a large OCL of the shoulder of the talus with a vascularised corticoperiosteal graft taken from the medial condyle of the femur was found to be a safe, reliable method of restoring the contour of the talus in the early to mid-term.

Cite this article: Bone Joint J 2015;97-B:1242–9.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1610 - 1617
1 Dec 2014
Lainiala O Eskelinen A Elo P Puolakka T Korhonen J Moilanen T

We conducted a retrospective study to assess the prevalence of adverse reactions to metal debris (ARMD) in patients operated on at our institution with metal-on-metal (MoM) total hip replacements with 36 mm heads using a Pinnacle acetabular shell. A total of 326 patients (150 males, 175 hips; 176 females, 203 hips) with a mean age of 62.7 years (28 to 85) and mean follow-up of 7.5 years (0.1 to 10.8) participating in our in-depth modern MoM follow-up programme were included in the study, which involved recording whole blood cobalt and chromium ion measurements, Oxford hip scores (OHS) and plain radiographs of the hip and targeted cross-sectional imaging. Elevated blood metal ion levels (> 5 parts per billion) were seen in 32 (16.1%) of the 199 patients who underwent unilateral replacement. At 23 months after the start of our modern MoM follow-up programme, 29 new cases of ARMD had been revealed. Hence, the nine-year survival of this cohort declined from 96% (95% CI 95 to 98) with the old surveillance routine to 86% (95% CI 82 to 90) following the new protocol. Although ARMD may not be as common in 36 mm MoM THRs as in those with larger heads, these results support the Medicines and Healthcare Products Regulatory Agency guidelines on regular reviews and further investigations, and emphasise the need for specific a follow-up programme for patients with MoM THRs.

Cite this article: Bone Joint J 2014; 96-B:1610–17.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1674 - 1680
1 Dec 2014
Choi WJ Lee JS Lee M Park JH Lee JW

We compared the clinical and radiographic results of total ankle replacement (TAR) performed in non-diabetic and diabetic patients. We identified 173 patients who underwent unilateral TAR between 2004 and 2011 with a minimum of two years’ follow-up. There were 88 male (50.9%) and 85 female (49.1%) patients with a mean age of 66 years (sd 7.9, 43 to 84). There were 43 diabetic patients, including 25 with controlled diabetes and 18 with uncontrolled diabetes, and 130 non-diabetic patients. The clinical data which were analysed included the Ankle Osteoarthritis Scale (AOS) and the American Orthopaedic Foot and Ankle Society (AOFAS) scores, as well the incidence of peri-operative complications.

The mean AOS and AOFAS scores were significantly better in the non-diabetic group (p = 0.018 and p = 0.038, respectively). In all, nine TARs (21%) in the diabetic group had clinical failure at a mean follow-up of five years (24 to 109), which was significantly higher than the rate of failure of 15 (11.6%) in the non-diabetic group (p = 0.004). The uncontrolled diabetic subgroup had a significantly poorer outcome than the non-diabetic group (p = 0.02), and a higher rate of delayed wound healing.

The incidence of early-onset osteolysis was higher in the diabetic group than in the non-diabetic group (p = 0.02). These results suggest that diabetes mellitus, especially with poor glycaemic control, negatively affects the short- to mid-term outcome after TAR.

Cite this article: Bone Joint J 2014;96-B:1674–80.