Advertisement for orthosearch.org.uk
Results 1 - 20 of 28
Results per page:
Bone & Joint 360
Vol. 12, Issue 4 | Pages 23 - 26
1 Aug 2023

The August 2023 Wrist & Hand Roundup360 looks at: Complications and patient-reported outcomes after trapeziectomy with a Weilby sling: a cohort study; Swelling, stiffness, and dysfunction following proximal interphalangeal joint sprains; Utility of preoperative MRI for assessing proximal fragment vascularity in scaphoid nonunion; Complications and outcomes of operative treatment for acute perilunate injuries: a systematic review; The position of the median nerve in relation to the palmaris longus tendon at the wrist: a study of 784 MR images; Basal fractures of the ulnar styloid? A randomized controlled trial; Proximal row carpectomy versus four-corner arthrodesis in SLAC and SNAC wrist; Managing cold intolerance after hand injury: a systematic review.


Bone & Joint 360
Vol. 11, Issue 3 | Pages 24 - 28
1 Jun 2022


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 91 - 91
1 Nov 2021
Aljasim O Yener C Demirkoparan M Bilge O Küçük L Gunay H
Full Access

Introduction and Objective. Zone 2 flexor tendon injuries are still one of the challenges for hand surgeons. It is not always possible to achieve perfect results in hand functions after these injuries. There is no consensus in the literature regarding the treatment of zone 2 flexor tendon injuries, tendon repair and surgical technique to be applied to the A2 pulley. The narrow fibro-osseous canal structure in zone 2 can cause adhesions and loss of motion due to the increase in tendon volume due to surgical repair. Different surgical techniques have been defined to prevent this situation. In our study, in the treatment of zone 2 flexor tendon injuries; Among the surgical techniques to be performed in addition to FDP tendon repair; We aimed to compare the biomechanical results of single FDS slip repair, A2 pulley release and two different pulley plasty methods (Kapandji and V-Y pulley plasty). Materials and Methods. In our study, 12 human upper extremity cadavers preserved with modified Larssen solution (MLS) and amputated at the mid ½ level of the arm were used. A total of 36 fingers (second, third and the fourth fingers were used for each cadaver) were divided into four groups and 9 fingers were used for each group. With the finger fully flexed, the FDS and FDP tendons were cut right in the middle of the A2 pulley and repaired with the cruciate four-strand technique. The surgical techniques described above were applied to the groups. Photographs of fingers with different loads (50 – 700 gr) were taken before and after the application. Proximal interphalangeal (PIP) joint angle, PIP joint maximum flexion angle and bowstring distance were measured. The gliding coefficient was calculated by applying the PIP joint angle to the single-phase exponential association equation. Results. Gliding coefficient after repair increased by %21.46 ± 44.41, %62.71 ± 116.9, %26.8 ± 35.35 and %20.39 ± 28.78 in single FDS slip repair, A2 pulley release, V-Y pulley plasty and Kapandji plasty respectively. The gliding coefficient increased significantly in all groups after surgical applications (p<0.05). PIP joint maximum flexion angle decreased by %3.17 ± 7.92, %12.82 ± 10.94, %8.33 ± 3.29 and %7.35 ± 5.02 in single FDS slip repair, A2 pulley release, V-Y pulley plasty and Kapandji plasty respectively. PIP joint maximum flexion angle decreased significantly after surgery in all groups (p<0.05). However, there was no statistically significant difference between surgical techniques for gliding coefficient and PIP joint maximum flexion angle. Bowstring distance between single FDS slip repair, kapandji pulley plasty and V-Y pulley plasty showed no significant difference in most loads (p>0.05). Bowstring distance was significantly increased in the A2 pulley release group compared to the other three groups (p<0.05). Conclusion. Digital motion was negatively affected after flexor tendon repair. Similar results were found in terms of gliding coefficient and maximum flexion angle among different surgical methods. As single FDS slipe repair preserves the anatomical structure of the A2 pulley therefore we prefer it as an ideal method for zone 2 flexor tendon repair. However, resection of FDS slip may jeopardizes nutrition to the flexor digitorum profundus tendon which weakens the repair site. Therefore the results must be confirmed by an in vivo study before a clinical recommendation can be made. Keywords: Flexor tendon; injury; pulley plasty; cadaver;


Bone & Joint 360
Vol. 10, Issue 2 | Pages 33 - 37
1 Apr 2021


Bone & Joint 360
Vol. 9, Issue 6 | Pages 27 - 30
1 Dec 2020


Bone & Joint 360
Vol. 9, Issue 5 | Pages 28 - 32
1 Oct 2020


Bone & Joint 360
Vol. 9, Issue 2 | Pages 23 - 27
1 Apr 2020


Bone & Joint 360
Vol. 8, Issue 1 | Pages 21 - 24
1 Feb 2019


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 125 - 125
1 Nov 2018
Kurnik C Mercer D Mercer R Salas C Moneim M Kamermans E Benjey L
Full Access

Extensor tendon attachment to the dorsum of the proximal phalanx may fully extend the finger metacarpal phalangeal joint (MPJ). 15 fresh-frozen cadaveric hands were axially loaded in the line of pull to the extensor digitorum comunis of the index, middle, ring and small finger at the level just proximal to the MPJ. We measured force of extension at the MP joint in 3 groups: 1) native specimen, 2) extensor tendon release at the proximal interphalangeal (PIP) joint with release of lumbricals/lateral bands, 3) extensor tendon release at the PIP joint and dorsal proximal phalanx and lumbrical/lateral band release. Degree change of extension was calculated using arctan function with height change of the distal aspect of the proximal phalanx, and the length of the proximal phalanx. We used Student T-test to determine significant decrease in the extension of the phalanges. Extension of all fingers decreased slightly when the extensor tendon were severed at the PIP joint with release of the lateral bands/lumbricals (8deg+/−2deg). After this release, the finger no longer extended. Slight loss of extension was not statistically significant (p >.05) between group 1 and group 2. Groups 1 and 2 were significantly different compared to group 3. In summary, distal extensor tendon transection and release of lateral bands/lumbricals resulted in little change in force and degree of finger extension. The distal insertion of the extensor, released when exposing the PIP joint dorsally, may not need to be repaired to the base of the middle phalanx


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1138 - 1145
1 Sep 2018
Soreide E Murad MH Denbeigh JM Lewallen EA Dudakovic A Nordsletten L van Wijnen AJ Kakar S

Aims

Dupuytren’s contracture is a benign, myoproliferative condition affecting the palmar fascia that results in progressive contractures of the fingers. Despite increased knowledge of the cellular and connective tissue changes involved, neither a cure nor an optimum form of treatment exists. The aim of this systematic review was to summarize the best available evidence on the management of this condition.

Materials and Methods

A comprehensive database search for randomized controlled trials (RCTs) was performed until August 2017. We studied RCTs comparing open fasciectomy with percutaneous needle aponeurotomy (PNA), collagenase clostridium histolyticum (CCH) with placebo, and CCH with PNA, in addition to adjuvant treatments aiming to improve the outcome of open fasciectomy. A total of 20 studies, involving 1584 patients, were included.


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 73 - 80
1 Jan 2018
Sanjuan-Cerveró R Carrera-Hueso FJ Vazquez-Ferreiro P Ramon-Barrios MA

Aims

The aim of this meta-analysis was to assess the safety and efficacy of collagenase clostridium histolyticum compared with fasciectomy and percutaneous needle fasciotomy (PNF) for Dupuytren’s disease.

Materials and Methods

We systematically searched PubMed, EMBASE, LILACS, Web of Science, Cochrane, Teseo and the ClinicalTrials.gov registry for clinical trials and cohort or case-control studies which compared the clinical outcomes and adverse effects of collagenase with those of fasciectomy or PNF.

Of 1345 articles retrieved, ten were selected. They described the outcomes of 425 patients treated with collagenase and 418 treated by fasciectomy or PNF. Complications were assessed using inverse-variance weighted odds ratios (ORs). Clinical efficacy was assessed by differences between the means for movement of the joint before and after treatment. Dose adjustment was applied in all cases.


Bone & Joint 360
Vol. 6, Issue 5 | Pages 18 - 20
1 Oct 2017


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 102 - 102
1 Jan 2017
Gindraux F Lepage D Loisel F Nallet A Tropet Y Obert L
Full Access

Used routinely in maxillofacial reconstructive surgery, the chondrocostal graft is also applied to hand surgery in traumatic or pathologic indications. The purpose of this overview was to analyze at long-term follow-up the radiological and histological evolution of this autograft, in hand and wrist surgery. We extrapolated this autograft technique to the elbow by using perichondrium. Since 1992, 148 patients have undergone chondrocostal autograft: 116 osteoarthritis of the thumb carpometacarpal joint, 18 radioscaphoid arthritis, 6 articular malunions of the distal radius, 4 kienbock's disease, and 4 traumatic loss of cartilage of the proximal interphalangeal (PIP) joint. Perichondrium autografts were used in 3 patients with elbow osteoarthritis. Magnetic Resonance Imaging (MRI) was performed in 19 patients with a mean follow-up of 68 months (4–159). Histological studies were performed on: i) perioperative chondrocostal grafts (n=3), ii) chondrocostal grafts explanted between 2 and 48 months after surgery (n=10), and iii) perioperative perichondrium grafts (n=2). Whatever the indication, the reconstruction by a chondrocostal/ostochondrocostal or perichondrium graft yielded satisfactory clinical results at long-term follow-up. The main question was the viability of the graft. -. For rib cartilage grafting: The radiological study indicated the non-wear of the graft and a certain degree of ossification. The MRI and histology confirmed a very small degree of osseous metaplasia and graft viability. The biopsies showed neo-vascularization of the cartilage that had undergone morphological, constitutional and architectural changes. Comparison of these structural modifications with perioperative chondrocostal graft histology is in progress. -. For perichondrium grafting: The first cases gave satisfactory clinical results but must be confirmed on a larger number of patients. Histological results highlighted a tissue composed of one fibrous layer and one cartilage-like layer, a common composition of supporting tissue. Despite the strong mechanical strain in the hand and wrist, chondrocostal graft is a biological arthroplasty that is trustworthy and secure over the long term, although it can cause infrequent complications inherent to this type of surgery. Despite the inevitable histological modification, the cartilage remains alive and is of satisfactory quality at long term follow-up and fulfills the requirements for interposition and reconstruction of an articular surface. The perichondrium graft constitutes a new arsenal to cure cartilage resurfacing. The importance of perichondrium for the survival of the grafted cartilage, as previously reported, as well as its role in resurfacing, is being investigated


Bone & Joint 360
Vol. 5, Issue 5 | Pages 19 - 21
1 Oct 2016


Bone & Joint 360
Vol. 5, Issue 3 | Pages 17 - 19
1 Jun 2016


Bone & Joint 360
Vol. 4, Issue 2 | Pages 17 - 20
1 Apr 2015

The April 2015 Wrist & Hand Roundup360 looks at: Non-operative hand fracture management; From the sublime to the ridiculous?; A novel approach to carpal tunnel decompression; Osteoporosis and functional scores in the distal radius; Ulnar variance and force distribution; Tourniquets in carpal tunnel under the spotlight; Scaphoid fractures reclassified; Osteoporosis and distal radial fracture fixation; PROMISing results in the upper limb


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 7 - 7
1 Dec 2014
Madhusudhan T Clay N
Full Access

Dupuytren's disease is often disabling and traditionally has been managed with various surgical methods, with recurrence rates up to 50 %. Recently clostridial collagenase injection has been licensed for use in the NHS. We prospectively analysed the results of clostridial collagenase injection in 62 patients with varying degrees of Metacarpo phalangeal (MCP) and Proximal interphalangeal (PIP) joint contractures. There were 48 males and 14 females with an average age of 66 years. The average MCPJ and PIPJ deformities were 33 and 17 degrees respectively. Following the infiltration and subsequent manipulation under local anaesthetic and night splinting for 3 months, patients were followed up at 4 weeks and 6 months. Deformities persisted in 5 patients and later required surgical correction. MCPJ deformities were more amenable for correction than PIPJ and in those with recurrence. The average residual deformity was 7 degrees. Common complications include bruising, swelling, pain not responding to routine analgesia, lymphangitis and skin break in some but none required any additional interventions. 14 patients had completed 6 month follow up and there was no recurrence. Subjective assessment through questionnaires revealed high patient satisfaction rate with early return to work within 1 week in most patients. Patients with previous operations preferred injections over operative correction. Collagenase injections are effective in deformity correction with higher satisfaction rate and low morbidity. Early results are encouraging but long term follow up is required to assess recurrence rates


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 59 - 59
1 Aug 2012
Bone M Cunningham J Field J Joyce T
Full Access

Finger arthroplasty lacks the success seen with hip and knee joint replacements. The Van Straten Leuwen Poeschmann Metal (LPM) prosthesis was intended for the proximal interphalangeal (PIP) joints. However revision rates of 30% after 19 months were reported alongside massive osteolysis. Three failed LPM titanium niobium (TiNb) coated cobalt chrome (CoCr) components were obtained- two distal and one proximal. All three components were analysed using an environmental scanning electron microscope (ESEM). This gave the chemical composition of the surface to determine if the TiNb surface coating was still intact. The distal components were analysed using a ZYGO non-contact profilometer (1nm resolution) with the proximal component unable to be analysed due to its shape. ZYGO analysis gave the roughness average (Ra) of the surface and determined the presence of scratches, pitting and other damage. Images obtained from both the ZYGO and the ESEM indicated that the surfaces of all components were heavily worn. On the articulating surfaces of both distal components unidirectional scratching was dominant, while the non-articulating surface showed multidirectional scratching. The presence of unidirectional scratching suggested two-body wear, whilst the multidirectional scratching on the non-articulating surface of the distal component suggested that trapped debris may have caused three-body wear. The ESEM chemical analysis showed that in some regions on the distal component the TiNb coating had been removed completely and in other areas it had been scratched or penetrated. On the proximal component the TiNb coating had been almost completely removed from the articulating surfaces and was only present in small amounts on the non-articulating surfaces. There was little evidence of bone attachment to the titanium coating which was intended to help provide fixation. ESEM images showed the coating had been removed in some sections where there was minimal scratching, suggesting this scratching did not impact significantly in the coating removal. Therefore here the main cause of coating removal may have been corrosion, although scratching may have also have played a part. The osteolysis reported clinically may have been linked to the wear debris from the failed coating


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 581 - 581
1 Oct 2010
Mansha M Miranda S
Full Access

Treatment for the comminuted intra-articular fractures of base of phalanxes remains a challenging problem in hand surgery. The outcomes are commonly associated with pain, stiffness, chronic instability and degenerative arthritis of proximal interphalangeal (PIP) joints. We present our short term results in 12 consecutive patients suffering from these complex fractures treated by closed reduction and application of a dynamic external fixator (Giddins’s frame). The average range of movement achieved was 11–86 degrees and there were no serious complications. We used the construct with slight modification and in our experience this may be helpful to reduce the pin site infection. It is relatively simple, uses widely available equipment (K-wire), and compact thus allows more than one finger to be treated. Early return to work, good pain relief and high level of patient’s satisfaction was achieved. Our short term results were comparable to best previously published results. Based on our experience we recommend this easy technique to treat these complex fractures of IP joints


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 293 - 296
1 Feb 2010
Afshar A

In this case report a four-year-old girl with ulnar dimelia is described. She had six digits without mirror symmetry in her right hand. The first pre-axial digit was excised and true pollicisation performed for the second pre-axial digit. The arterial anatomy was abnormal but there was not symmetrical development of the arterial tree.