Aims

The standard of surgical treatment for lower limb neoplasms had been characterized by highly interventional techniques, leading to severe kinetic impairment of the patients and incidences of phantom pain. Rotationplasty had arisen as a potent limb salvage treatment option for young cancer patients with lower limb bone tumours, but its impact on the gait through comparative studies still remains unclear several years after the introduction of the procedure. The aim of this study is to assess the effect of rotationplasty on gait parameters measured by gait analysis compared to healthy individuals.

Methods

The MEDLINE, Scopus, and Cochrane databases were systematically searched without time restriction until 10 January 2022 for eligible studies. Gait parameters measured by gait analysis were the outcomes of interest.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 49 - 49
1 May 2021
Gigi R Kurien B Giles S Fernandes J
Full Access

Introduction

The purpose of our study was to retrospectively analyze our patients who were treated for FH and PFFD by means of guided growth temporary Hemiepiphysiodesis.

We sought to determine the effectiveness of the procedure, as well as its success rates, complications, and rebound phenomena.

Materials and Methods

We retrospectively reviewed the medical records and all routine preoperative and post operative long standing radiograph of all the FH and PFFD patients that were operated in our institute using guided growth hemiepiphysiodesis technique of distal femur or proximal tibia between 2007 to 2017.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 31 - 33
1 Dec 2013

The December 2013 Children’s orthopaedics Roundup360 looks at: Long term-changes in hip morphology following osteotomy; Arthrogrypotic wrist contractures are surgically amenable; Paediatric femoral lengthening over a nail; Current management of paediatric supracondylar fractures; MRI perfusion index predictive of Perthes’ progression; Abduction bracing effective in residual acetabular deformity; Hurler syndrome in the spotlight; and the Pavlik works for femoral fractures too!


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 192 - 198
1 Feb 2013
Ackman J Altiok H Flanagan A Peer M Graf A Krzak J Hassani S Eastwood D Harris GF

Van Nes rotationplasty may be used for patients with congenital proximal focal femoral deficiency (PFFD). The lower limb is rotated to use the ankle and foot as a functional knee joint within a prosthesis. A small series of cases was investigated to determine the long-term outcome. At a mean of 21.5 years (11 to 45) after their rotationplasty, a total of 12 prosthetic patients completed the Short-Form (SF)-36, Faces Pain Scale-Revised, Harris hip score, Oswestry back pain score and Prosthetic Evaluation Questionnaires, as did 12 age- and gender-matched normal control participants. A physical examination and gait analysis, computerised dynamic posturography (CDP), and timed ‘Up & Go’ testing was also completed. Wilcoxon Signed rank test was used to compare each PFFD patient with a matched control participant with false discovery rate of 5%. There were no differences between the groups in overall health and well-being on the SF-36. Significant differences were seen in gait parameters in the PFFD group. Using CDP, the PFFD group had reduced symmetry in stance, and reduced end point and maximum excursions. Patients who had undergone Van Nes rotationplasty had a high level of function and quality of life at long-term follow-up, but presented with significant differences in gait and posture compared with the control group. Cite this article: Bone Joint J 2013;95-B:192–8


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 788 - 792
1 Jun 2011
Schiedel FM Pip S Wacker S Pöpping J Tretow H Leidinger B Rödl R

We report the results of intramedullary leg lengthening conducted between 2002 and 2009 using the Intramedullary Skeletal Kinetic Distractor in 69 unilateral lengthenings involving 58 femora and 11 tibiae. We identified difficulties that occurred during the treatment and assessed whether they were specifically due to the implant or independent of it. Paley’s classification for evaluating problems, obstacles and complications with external fixators was adopted, and implant-specific difficulties were continuously noted. There were seven failures requiring premature removal of the device, in four due to nail breakage and three for other reasons, and five unsuccessful outcomes after completion of the lengthening. In all, 116 difficulties were noted in 45 patients, with only 24 having problem-free courses. In addition to the difficulties arising from the use of external fixators, there were almost the same number again of implant-specific difficulties.

Nevertheless, successful femoral lengthening was achieved in 52 of the 58 patients (90%). However, successful tibial lengthening was only achieved in five of 11 patients (45%).


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 23 - 23
1 Mar 2008
Li P Forder J Ganz R
Full Access

To investigate the proportion of dysplastic hips which are retroverted. We studied the radiographs of over seven hundred patients with dysplastic hips who had had a periacetabular osteotomy in the period 1984–1998. We excluded patients with neuromuscular dysplasia, Perthes’ disease of the hip, post-traumatic dysplasia and proximal focal femoral deficiency. We selected 232 radiographs of patients with congenital acetabular dysplasia. A number of parameters were measured including lateral centre-edge angle, anterior centre-edge angle, acetabular index of weight-bearing surface, femoral head extrusion index and acetabular index of depth to width. Also recorded were acetabular version and congruency between femoral head and acetabulum. The lateral centre-edge angle of Wiberg had a mean value of 6.4° (SD 8.9°), the mean anterior centre-edge angle was 1.3° (SD 13.5°) and the acetabular index of weight-bearing surface of the acetabulum had a mean value of 24.5° (SD 9.7°). The majority (192, 82.8%) of acetabula were anteverted as might be expected. However, a significant minority (40, 17.2%) were retroverted. The mean anterior centre-edge angle in retroverted hips was 6.7° (SD 9.4°) compared with 0.4° (SD 13.3°) in anteverted hips. The authors have shown that, in a typical group of patients with congenital acetabular dysplasia significant enough to warrant periacetabular osteotomy, the majority of hips as expected have anteverted acetabula. However, a significant minority are retroverted. This finding has an important bearing on the performance of the osteotomy. We have also found that most if not all the information required prior to and following periac-etabular osteotomy can be obtained from an orthograde view of the pelvis


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 361 - 362
1 Sep 2005
Walter W Zicat B O’Sullivan M Walter W
Full Access

Introduction and Aims: Third generation alumina ceramic-on-ceramic bearings are being increasingly used in hip replacement surgery as an alternative to polyethylene because of the unacceptably high wear of polyethylene bearings and associated osteolysis leading to failure of hip replacement. Follow-up time with these modern ceramic bearings is still short. Method: We report the minimum five-year follow-up of our first 300 hip replacements with these bearings in 283 patients, done between June 1997 and February 1999. Three hundred ceramic-on-ceramic Osteonics Securfit or Securfit Plus stems were used with the Osteonics Securfit cup in all cases – these are cement-free and hydroxyapatite coated. The bearings were third generation alumina ceramic femoral heads and cup inserts manufactured by CeramTec. The average age was 58 years and there were 52% females. Osteoarthritis was the diagnosis in 93% and inflammatory arthritis in four percent. We used 92% 32mm bearings and eight percent 28mm bearings. Results: Mean Harris hip score improved from 56 pre-operatively to 94 at five years. Complications included: three non-fatal and no fatal pulmonary emboli, one deep and four superficial infections. There were four revisions for periprosthetic femoral fracture, one for cup malposition and one for sciatic nerve palsy in a patient with proximal focal femoral deficiency. There were a further four re-operations for psoas tendonitis where the psoas tendon was released. There were no re-operations for bearing failure and none of the ceramic components failed catastrophically, although a small number of acetabular inserts chipped around the rim during insert and were discarded. Of particular interest is the fact that there was no osteolysis seen in any of these hips, either around the acetabulum or around the femur. The usual small lytic areas noted around the calcar and the trochanteric regions of the femur that are commonly seen with polyethylene bearings were completely absent in this group. Three of the hips squeak intermittently with vigorous activity. Conclusion: Third generation ceramic-on-ceramic bearings have only been available for seven or eight years. Early results using these new bearings are encouraging, in that osteolysis to date has not been seen in this series. No hip in this series has been revised for failure of these ceramic implants. It will be a further five to 10 years before we can be certain how these newer bearings will perform in the long term, but the five-year results are encouraging


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 69 - 69
1 Jan 2004
Li P Ganz R Forder J
Full Access

It is generally agreed that in acetabular dysplasia the acetabulum lies excessively anteverted. Although this is true for the majority of hips, we have found that in some patients with dysplastic hips, the acetabulum lies unexpectedly in retroversion. Aim: To investigate the proportion of dysplastic hips which are retroverted. Method: We studied the radiographs of over seven hundred patients with dysplastic hips and who had had a periacetabular osteotomy in the period 1984–1998. We excluded patients with neuromuscular dysplasia, Perthes disease of the hip, post-traumatic dysplasia and proximal focal femoral deficiency. We selected 232 radiographs of patients with congenital acetabular dysplasia. A number of parameters were measured including, lateral centre edge angle, anterior centre-edge angle, acetabular index of weight bearing surface, femoral head extrusion index and acetabular index of depth to width. Also recorded was acetabular version and congruency between femoral head and acetabulum. Results: The lateral centre-edge angle of Wiberg had a mean value of 6.4° (SD 8.9°), the mean anterior centre-edge angle was 1.3° (SD 13.5°) and the acetabular index of weight bearing surface of the acetabulum had a mean value of 24.5° (SD 9.7°). The majority (192, 82.8%) of acetabula were anteverted as might be expected. However, a significant minority (40,17.2%) were retroverted. The mean anterior centre-edge angle in retroverted hips was 6.7° (SD 9.4°) compared with 0.4° (SD 13.3°) in anteverted hips. Conclusion: The authors have shown that in a typical group of patients with congenital acetabular dysplasia, significant enough to warrant periacetabular osteotomy, the majority of hips as expected have anteverted acetabula. However, a significant minority are retroverted. This finding has an important bearing in the performance of the osteotomy


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 5 | Pages 557 - 568
1 Nov 1983
Gillespie R Torode I

Sixty-nine patients with congenital abnormality of the femur were reviewed. Their manifestation of femoral dysplasia ranged from an intact femur approximately 60 per cent of the length of the normal leg to a subtotal absence of the femur in which only the femoral condyles remained, often with a congenital fusion of the knee joint. Two groups were defined: Group I consisted of those with congenital hypoplastic femur in which the hip and knee could be made functional and where, in some patients at least, leg equalisation was possible; Group II consisted of those with true proximal focal femoral deficiency where the hip joint was never normal and the knee joint was always useless. The patients in each group were examined and evaluated with respect to clinical signs, surgical procedures performed, and prosthetic requirements and function. A protocol of treatment for both groups is suggested