Advertisement for orthosearch.org.uk
Results 1 - 20 of 49
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 85 - 85
22 Nov 2024
Sayol RR Lopez XP Regulez BV Bueno JC Garcia JCM Álvarez JM Fernández JS Gonzalez SG
Full Access

Aim. There is controversy regarding the use of Antibiotic-loaded cement (ALBC) as compared to non-antibiotic-loaded cement (NALBC) to reduce the overall infection rate without affecting implant survival or adding additional risks on fixation for primary total knee arthroplasty (TKA). Method. To conduct the analysis, we utilized the Catalan Arthroplasty Registry (RACat) for the TKAs implanted between 2005 and 2017. The primary variable recorded was the use of cement with or without antibiotics. Other recorded variables included were age, sex, diabetes mellitus, obesity, Charlson index and type of hospital. We analyzed the effect of ALBC vs. NALBC in reducing the risk of prosthetic infection at 3, 6, 12, and 24 months as well as prosthetic survival due to mechanical causes at 1, 5, and 10 years. Univariate and multivariable analyses of risk factors were conducted. Thereby, an interactive predictive model that determines the risk of prosthetic infection based on each patient's characteristics was created. Results. A total of 28,287 TKAs from the RACat were analyzed. In that total, there were 19,788 NALBC and 8,499 ALBC. The infection rates for TKAs with NALBC vs. those with ALBC at 3, 6, 12, and 24 months were respectively: 1.69% vs. 1.39% (p=0.132); 1.81% vs. 1.56% (p=0.147); 2.14% vs. 1.73% (p=0.030); 2.51% vs. 1.86% (p=0.001). A statistically significant reduction in periprosthetic infection rate was observed in the ALBC group at 12 and 24 months. No differences were observed between the two groups in terms of prosthetic mechanical survival. Being younger, male and having had previous knee surgery or having a high comorbidity index all led to a higher risk of prosthetic revision due to infection. Conclusions. The use of ALBC as a fixation method for TKA leads to a reduction in the risk of prosthetic infection without altering the mechanical survival of the implant. The creation of a predictive model helps determine the individualized risk of prosthetic infection based on the patient's characteristics


Bone & Joint Open
Vol. 5, Issue 8 | Pages 628 - 636
2 Aug 2024
Eachempati KK Parameswaran A Ponnala VK Sunil A Sheth NP

Aims

The aims of this study were: 1) to describe extended restricted kinematic alignment (E-rKA), a novel alignment strategy during robotic-assisted total knee arthroplasty (RA-TKA); 2) to compare residual medial compartment tightness following virtual surgical planning during RA-TKA using mechanical alignment (MA) and E-rKA, in the same set of osteoarthritic varus knees; 3) to assess the requirement of soft-tissue releases during RA-TKA using E-rKA; and 4) to compare the accuracy of surgical plan execution between knees managed with adjustments in component positioning alone, and those which require additional soft-tissue releases.

Methods

Patients who underwent RA-TKA between January and December 2022 for primary varus osteoarthritis were included. Safe boundaries for E-rKA were defined. Residual medial compartment tightness was compared following virtual surgical planning using E-rKA and MA, in the same set of knees. Soft-tissue releases were documented. Errors in postoperative alignment in relation to planned alignment were compared between patients who did (group A) and did not (group B) require soft-tissue releases.


Bone & Joint 360
Vol. 13, Issue 3 | Pages 31 - 34
3 Jun 2024

The June 2024 Shoulder & Elbow Roundup360 looks at: Reverse versus anatomical total shoulder replacement for osteoarthritis? A UK national picture; Acute rehabilitation following traumatic anterior shoulder dislocation (ARTISAN): pragmatic, multicentre, randomized controlled trial; acid for rotator cuff repair: a systematic review and meta-analysis of randomized controlled trials; Metal or ceramic humeral head total shoulder arthroplasty: an analysis of data from the National Joint Registry; Platelet-rich plasma has better results for long-term functional improvement and pain relief for lateral epicondylitis: a systematic review and meta-analysis of randomized controlled trials; Quantitative fatty infiltration and 3D muscle volume after nonoperative treatment of symptomatic rotator cuff tears: a prospective MRI study of 79 patients; Locking plates for non-osteoporotic proximal humeral fractures in the long term; A systematic review of the treatment of primary acromioclavicular joint osteoarthritis.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 133 - 138
1 May 2024
Peuchot H Jacquet C Fabre-Aubrespy M Ferguson D Ollivier M Flecher X Argenson J

Aims

Dual-mobility acetabular components (DMCs) have improved total hip arthroplasty (THA) stability in femoral neck fractures (FNFs). In osteoarthritis, the direct anterior approach (DAA) has been promoted for improving early functional results compared with the posterolateral approach (PLA). The aim of this study was to compare these two approaches in FNF using DMC-THA.

Methods

A prospective continuous cohort study was conducted on patients undergoing operation for FNF using DMC by DAA or PLA. Functional outcome was evaluated using the Harris Hip Score (HHS) and Parker score at three months and one year. Perioperative complications were recorded, and radiological component positioning evaluated.


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 482 - 491
1 May 2024
Davies A Sabharwal S Liddle AD Zamora Talaya MB Rangan A Reilly P

Aims. Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. Methods. NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation. Results. A total of 4,799 TSAs (3,578 metal, 1,221 ceramic) and 1,363 HAs (1,020 metal, 343 ceramic) were included. The rate of revision was higher for metal compared with ceramic TSA, hazard ratio (HR) 3.31 (95% confidence interval (CI) 1.67 to 6.58). At eight years, prosthesis survival for ceramic TSA was 98.7% (95% CI 97.3 to 99.4) compared with 96.4% (95% CI 95.2 to 97.3) for metal TSA. The majority of revision TSAs were for cuff insufficiency or instability/dislocation. There was no significant difference in the revision rate for ceramic compared with metal head HA (HR 1.33 (95% CI 0.76 to 2.34)). For ceramic HA, eight-year prosthetic survival was 92.8% (95% CI 86.9 to 96.1), compared with 91.6% (95% CI 89.3 to 93.5) for metal HA. The majority of revision HAs were for cuff failure. Conclusion. The rate of all-cause revision was higher following metal compared with ceramic humeral head TSA in patients with OA and an intact rotator cuff. There was no difference in the revision rate for HA according to bearing surface. Cite this article: Bone Joint J 2024;106-B(5):482–491


Bone & Joint 360
Vol. 12, Issue 5 | Pages 39 - 42
1 Oct 2023

The October 2023 Oncology Roundup360 looks at: Are pathological fractures in patients with osteosarcoma associated with worse survival outcomes?; Spotting the difference: how secondary osteosarcoma manifests in retinoblastoma survivors versus conventional cases; Accuracy of MRI scans in predicting intra-articular joint involvement in high-grade sarcomas around the knee; Endoprosthetic reconstruction for lower extremity soft-tissue sarcomas with bone involvement; Local relapse of soft-tissue sarcoma of the extremities or trunk wall operated on with wide margins without radiation therapy; 3D-printed, custom-made prostheses in patients who had resection of tumours of the hand and foot; Long-term follow-up for low-grade chondrosarcoma; Evaluation of local recurrence and diagnostic discordance in chondrosarcoma patients undergoing preoperative biopsy; Radiological scoring and resection grade for intraosseous chondrosarcoma.


Bone & Joint Open
Vol. 3, Issue 9 | Pages 733 - 740
21 Sep 2022
Sacchetti F Aston W Pollock R Gikas P Cuomo P Gerrand C

Aims

The proximal tibia (PT) is the anatomical site most frequently affected by primary bone tumours after the distal femur. Reconstruction of the PT remains challenging because of the poor soft-tissue cover and the need to reconstruct the extensor mechanism. Reconstructive techniques include implantation of massive endoprosthesis (megaprosthesis), osteoarticular allografts (OAs), or allograft-prosthesis composites (APCs).

Methods

This was a retrospective analysis of clinical data relating to patients who underwent proximal tibial arthroplasty in our regional bone tumour centre from 2010 to 2018.


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 747 - 757
1 Jun 2022
Liang H Yang Y Guo W Yan L Tang X Li D Qu H Zang J Du Z

Aims

The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection.

Methods

From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients.


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 604 - 612
1 May 2022
MacDessi SJ Wood JA Diwan A Harris IA

Aims

Intraoperative pressure sensors allow surgeons to quantify soft-tissue balance during total knee arthroplasty (TKA). The aim of this study was to determine whether using sensors to achieve soft-tissue balance was more effective than manual balancing in improving outcomes in TKA.

Methods

A multicentre randomized trial compared the outcomes of sensor balancing (SB) with manual balancing (MB) in 250 patients (285 TKAs). The primary outcome measure was the mean difference in the four Knee injury and Osteoarthritis Outcome Score subscales (ΔKOOS4) in the two groups, comparing the preoperative and two-year scores. Secondary outcomes included intraoperative balance data, additional patient-reported outcome measures (PROMs), and functional measures.


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1783 - 1790
1 Dec 2021
Montgomery S Bourget-Murray J You DZ Nherera L Khoshbin A Atrey A Powell JN

Aims

Total hip arthroplasty (THA) with dual-mobility components (DM-THA) has been shown to decrease the risk of dislocation in the setting of a displaced neck of femur fracture compared to conventional single-bearing THA (SB-THA). This study assesses if the clinical benefit of a reduced dislocation rate can justify the incremental cost increase of DM-THA compared to SB-THA.

Methods

Costs and benefits were established for patients aged 75 to 79 years over a five-year time period in the base case from the Canadian Health Payer’s perspective. One-way and probabilistic sensitivity analysis assessed the robustness of the base case model conclusions.


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1479 - 1487
1 Sep 2021
Davis ET Pagkalos J Kopjar B

Aims

The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid total hip arthroplasties (THAs).

Methods

We undertook a registry study combining the National Joint Registry dataset with polyethylene manufacturing characteristics as supplied by the manufacturers. The primary endpoint was revision for any reason. We performed further analyses on other reasons including instability, aseptic loosening, wear, and liner dissociation. The primary analytic approach was Cox proportional hazard regression.


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1405 - 1413
1 Aug 2021
Ogura K Fujiwara T Morris CD Boland PJ Healey JH

Aims

Rotating-hinge knee prostheses are commonly used to reconstruct the distal femur after resection of a tumour, despite the projected long-term burden of reoperation due to complications. Few studies have examined the factors that influence their failure and none, to our knowledge, have used competing risk models to do so. The purpose of this study was to determine the risk factors for failure of a rotating-hinge knee distal femoral arthroplasty using the Fine-Gray competing risk model.

Methods

We retrospectively reviewed 209 consecutive patients who, between 1991 and 2016, had undergone resection of the distal femur for tumour and reconstruction using a rotating-hinge knee prosthesis. The study endpoint was failure of the prosthesis, defined as removal of the femoral component, the tibial component, or the bone-implant fixation; major revision (exchange of the femoral component, tibial component, or the bone-implant fixation); or amputation.


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1289 - 1296
1 Oct 2020
Amstutz HC Le Duff M

Aims

Hip resurfacing arthroplasty (HRA) is typically indicated for young and active patients. Due to the longevity of arthroplasty, these patients are likely to undergo revision surgery during their lifetime. There is a paucity of information on the long-term outcome of revision surgeries performed after failed HRA. The aim of our study was to provide survivorship data as well as clinical scores after HRA revisions.

Methods

A total of 42 patients (43 hips) were revised after HRA at our centre to a variety of devices, including four HRA and 39 total hip arthroplasties (THAs). In addition to perioperative complications, University of California, Los Angeles (UCLA) hip scores and 12-Item Short-Form Health Survey questionnaire (SF-12) quality of life scores were collected at follow-up visits after the primary HRA and after revision surgery.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 50 - 50
1 Dec 2019
Ullmark G Sotiriou D Stigbrand H
Full Access

Introduction. Periprosthetic joint infection (PJI) represents the costliest complication in Orthopedics. Studies of mixing vancomycin to bone graft at Impaction Bone Grafting (IBG) have shown high local concentration for 3 weeks. Patients and methods. 55 consecutive revisions PJI, age 68 (SD 10.9), (9 one-stage and 46 two-stage) were retrospectively analyzed. All cases were revised using IBG. Most cases had vancomycin mixed in graft or added locally in joint. All had bone cement containing Gentamycin and Vancomycin. Follow up 2–16 years included clinical Merle d'Aubigne-Postel score, radiology and laboratory tests. We analyzed surgical time, bleeding, hospitalization time, infection eradication and prosthetic survival for one- and two-stage revision procedures. One patient was lost to follow up and 6 died (2 one- and 4 2-stage) before 2 years. Values are mean and SD. Analyses done by students t-test. Results. Preoperatively scores for 1- and 2-stage groups were 11.7 (0.79) and 10.2 (1.27) respectively. Follow up scores were 17.5 (0.38) and 15.9 (0.73) respectively. Total intra-operative blood loss (ml) for one- and two-stage procedures were 1638 (780) and 2764 (828) respectively p<0.05. Total surgery time (minutes): 238 (206) and 409 (108) respectively p<0.05. Total hospitalization time (days): 13 (6.2) and 34 (13) p<0.05. Radiology at follow-up showed no signs of PJI, signs of mechanical loosening in one. There were no persistent or new PJI, no revision for mechanical loosening. Two revision for any reason in the 2-stage and one in the 1-stage group. Five reoperations without component exchange for periprosthetic fracture, all in the 2-stage group. Conclusion. No mechanical loosening and no persistent or new PJI are favourable results. Blood loss, hospitalization- and surgery-time were substantially increased for the two-stage group. Muscle atrophy, osteoporotic development and decrease general physical condition are all well-known side effects of two-stage procedure. Revision one-stage hip PJI using IBG avoids increased suffering and resources connected to the two-stage procedure. Literatures have not shown eradication of PJI, to be clearly superior after two- compared to one-stage procedures. Reconstitution of bone defects and the possibility of very high local antibiotic concentration are substantial advantages when using IBG. We recommend a careful one-stage IBG procedure using antibiotic loaded graft for none “difficult to treat” cases


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 101 - 108
1 Jan 2018
Stevenson JD Kumar VS Cribb GL Cool P

Aims

Dislocation rates are reportedly lower in patients requiring proximal femoral hemiarthroplasty than for patients undergoing hip arthroplasty for neoplasia. Without acetabular replacement, pain due to acetabular wear necessitating revision surgery has been described. We aimed to determine whether wear of the native acetabulum following hemiarthroplasty necessitates revision surgery with secondary replacement of the acetabulum after proximal femoral replacement (PFR) for tumour reconstruction.

Patients and Methods

We reviewed 100 consecutive PFRs performed between January 2003 and January 2013 without acetabular resurfacing. The procedure was undertaken in 74 patients with metastases, for a primary bone tumour in 20 and for myeloma in six. There were 48 male and 52 female patients, with a mean age of 61.4 years (19 to 85) and median follow-up of two years (interquartile range (IQR) 0.5 to 3.7 years). In total, 52 patients presented with a pathological fracture and six presented with failed fixation of a previously instrumented pathological fracture.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 841 - 848
1 Jun 2017
Hipfl C Stihsen C Puchner SE Kaider A Dominkus M Funovics PT Windhager R

Aims

Pelvic reconstruction after the resection of a tumour around the acetabulum is a challenging procedure due to the complex anatomy and biomechanics. Several pelvic endoprostheses have been introduced, but the rates of complication remain high. Our aim was to review the use of a stemmed acetabular pedestal cup in the management of these patients.

Patients and Methods

The study involved 48 patients who underwent periacetabular reconstruction using a stemmed pedestal cup (Schoellner cup; Zimmer Biomet Inc., Warsaw, Indiana) between 2000 and 2013. The indications for treatment included a primary bone tumour in 27 patients and metastatic disease in 21 patients. The mean age of the patients at the time of surgery was 52 years (16 to 83).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 3 - 3
1 Dec 2016
Jacobs A Menno B Meis JF Van Hellemondt G Goosen J
Full Access

Aim. Despite a preoperative workup with no evidence to suspect a prosthetic joint infection (PJI) before revision surgery, routinely obtained intraoperative cultures still can be unexpectedly positive. The purpose of this study was (1) to assess the incidence of unexpected positive intraoperative cultures in presumed aseptic knee and hip revisions and (2) to determine whether a difference exists between the infection-free implant survival rate of patients with and without unexpected positive intraoperative cultures. Method. We selected patients who underwent a one-stage revision total knee arthroplasty (TKA) or total hip arthroplasty (THA) for different reasons. Three or more separate intraoperative cultures were obtained during each procedure. A negative result was defined as less than two positive cultures with the same microorganism. An unsuspected PJI was defined as having two or more positive cultures with the same microorganism. Patients’ medical records were reviewed to collect demographics, preoperative laboratory results, culture results, and the occurrence of infection during follow-up. Results. A total of 340 and 339 patients with a presumed aseptic knee and hip revision, respectively, were analyzed. The incidence of unsuspected PJIs was 7.9% and 12.1% in the knees and hips, respectively. Of these unsuspected PJIs, the infection-free prosthetic survival rate at 2 year follow-up was 88% (95%CI 59–97) and 92% (95%CI 73–98) in knees and hips, respectively. In the knee group, the infection-free prosthetic survival rate of patients with an unsuspected PJI was significantly lower compared to that of patients with negative intraoperative culture results (88% (95%CI 59–97) versus 97% (95%CI 93–99) with p=0.01). In the hip group, there was no such a difference (92% (95%CI 73–98) versus 93% (95%CI 88–96) with p=0.41). Conclusions. We found incidences of unsuspected PJI and infection-free prosthetic survival rates that are comparable with previous studies. During follow-up after one-stage revision TKA, a higher incidence of infection was observed in patients with an unsuspected PJI. This difference was not observed in the hip revisions


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 27 - 27
1 Dec 2016
Higuera C
Full Access

Background. The clinical benefit of chronic suppression with oral antibiotics as a salvage treatment for periprosthetic joint infection is unclear. The purpose of this study was to compare infection-free prosthetic survival rates between patients who received chronic oral antibiotics and those who did not following irrigation and debridement with polyethylene exchange or two-stage revision for periprosthetic joint infection. Methods. We reviewed the records on all irrigation and debridement procedures with polyethylene exchange and two-stage revisions performed at our institution from 1996 to 2010 for hip or knee periprosthetic joint infection. Of 625 patients treated with a total of 655 eligible revisions, ninety-two received chronic oral antibiotics for a minimum of six months and were eligible for inclusion in our study. These patients were compared with a matched cohort (ratio of 1:3) who did not receive chronic oral antibiotics. Results. The five-year infection-free prosthetic survival rate was 68.5% (95% confidence interval = 59.2% to 79.3%) for the antibiotic-suppression group and 41.1% (95% CI = 34.9% to 48.5%) for the non-suppression group (hazard ratio = 0.63, p = 0.008). Stratification by the type of surgery and the infecting organism showed a higher five-year survival rate for the patients in the suppression group who underwent irrigation and debridement with polyethylene exchange (64.7%) compared with those in the non-suppression group who underwent irrigation and debridement with polyethylene exchange (30.4%, p < 0.0001) and a higher five-year survival rate for the patients in the suppression group who had a Staphylococcus aureus infection (57.4%) compared with those in the non-suppression group who had a Staphylococcus aureus infection (40.1%, p = 0.047). Conclusions. Chronic suppression with oral antibiotics increased the infection-free prosthetic survival rate following surgical treatment for periprosthetic joint infection. Patients who underwent irrigation and debridement with polyethylene exchange and those who had a Staphylococcus aureus infection had the greatest benefit


Bone & Joint 360
Vol. 5, Issue 5 | Pages 30 - 32
1 Oct 2016


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1057 - 1063
1 Aug 2013
Zeng Y Shen B Yang J Zhou ZK Kang PD Pei FX

The purpose of this study was to undertake a meta-analysis to determine whether there is lower polyethylene wear and longer survival when using mobile-bearing implants in total knee replacement when compared with fixed-bearing implants. Of 975 papers identified, 34 trials were eligible for data extraction and meta-analysis comprising 4754 patients (6861 knees). We found no statistically significant differences between the two designs in terms of the incidence of radiolucent lines, osteolysis, aseptic loosening or survival. There is thus currently no evidence to suggest that the use of mobile-bearing designs reduce polyethylene wear and prolong survival after total knee replacement.

Cite this article: Bone Joint J 2013;95-B:1057–63.