Advertisement for orthosearch.org.uk
Results 1 - 20 of 40
Results per page:
Bone & Joint 360
Vol. 13, Issue 2 | Pages 26 - 29
1 Apr 2024

The April 2024 Wrist & Hand Roundup. 360. looks at: Lunocapitate versus four-corner fusion in scapholunate or scaphoid nonunion advanced collapse: a randomized controlled trial; Postoperative scaphoid alignment, smoking, and avascular necrosis determine outcomes; Grip strength signals broader health concerns in females with distal radius fractures; Clearing the smoke: how smoking status influences recovery from open carpal tunnel release surgery; Age matters: assessing the likelihood of corrective surgery after distal radius fractures; Is pronator quadratus muscle repair required after anterior plate fixation for distal radius fractures?; Efficacy of total wrist arthroplasty: a comparative analysis of inflammatory and non-inflammatory arthritis outcomes; A comprehensive review of the one-bone forearm as a salvage technique


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 111 - 111
10 Feb 2023
Sonntag J Landale K Brorson S A. Harris I
Full Access

The aim of this study was to investigate surgeons’ reported change of treatment preference in response to the results and conclusion from a randomized controlled trial (RCT) and to study patterns of change between subspecialties and nationalities. Two questionnaires were developed through the Delphi process for this cross-sectional survey of surgical preference. The first questionnaire was sent out before the publication of a RCT and the second questionnaire was sent out after publication. The RCT investigated repair or non-repair of the pronator quadratus (PQ) muscle during volar locked plating of distal radial fractures (DRFs). Overall, 380 orthopaedic surgeons were invited to participate in the first questionnaire, of whom 115 replied. One hundred surgeons were invited to participate in the second questionnaire. The primary outcome was the proportion of surgeons for whom a treatment change was warranted, who then reported a change of treatment preference following the RCT. Secondary outcomes included the reasons for repair or non-repair, reasons for and against following the RCT results, and difference of preferred treatment of the PQ muscle between surgeons of different nationalities, qualifications, years of training, and number of procedures performed per year. Of the 100 surgeons invited for the second questionnaire, 74 replied. For the primary outcome, 6 of 32 surgeons (19%), who usually repaired the PQ muscle and therefore a change of treatment preference was warranted, reported a change of treatment preference based on the RCT publication. Of the secondary outcomes, restoring anatomy was the most common response for repairing the PQ muscle. The majority of the orthopaedic surgeons, where a change of treatment preference was warranted based on the results and conclusion of a RCT, did not report willingness to change their treatment preference


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 430 - 439
1 Mar 2021
Geary M Gaston RG Loeffler B

Upper limb amputations, ranging from transhumeral to partial hand, can be devastating for patients, their families, and society. Modern paradigm shifts have focused on reconstructive options after upper extremity limb loss, rather than considering the amputation an ablative procedure. Surgical advancements such as targeted muscle reinnervation and regenerative peripheral nerve interface, in combination with technological development of modern prosthetics, have expanded options for patients after amputation. In the near future, advances such as osseointegration, implantable myoelectric sensors, and implantable nerve cuffs may become more widely used and may expand the options for prosthetic integration, myoelectric signal detection, and restoration of sensation. This review summarizes the current advancements in surgical techniques and prosthetics for upper limb amputees.

Cite this article: Bone Joint J 2021;103-B(3):430–439.


Bone & Joint 360
Vol. 9, Issue 6 | Pages 27 - 30
1 Dec 2020


Bone & Joint Open
Vol. 1, Issue 9 | Pages 549 - 555
11 Sep 2020
Sonntag J Landale K Brorson S Harris IA

Aims. The aim of this study was to investigate surgeons’ reported change of treatment preference in response to the results and conclusion from a randomized contolled trial (RCT) and to study patterns of change between subspecialties and nationalities. Methods. Two questionnaires were developed through the Delphi process for this cross-sectional survey of surgical preference. The first questionnaire was sent out before the publication of a RCT and the second questionnaire was sent out after publication. The RCT investigated repair or non-repair of the pronator quadratus (PQ) muscle during volar locked plating of distal radial fractures (DRFs). Overall, 380 orthopaedic surgeons were invited to participate in the first questionnaire, of whom 115 replied. One hundred surgeons were invited to participate in the second questionnaire. The primary outcome was the proportion of surgeons for whom a treatment change was warranted, who then reported a change of treatment preference following the RCT. Secondary outcomes included the reasons for repair or non-repair, reasons for and against following the RCT results, and difference of preferred treatment of the PQ muscle between surgeons of different nationalities, qualifications, years of training, and number of procedures performed per year. Results. Of the 100 surgeons invited for the second questionnaire, 74 replied. For the primary outcome, six of 32 surgeons (19%), who usually repaired the PQ muscle and therefore a change of treatment preference was warranted, reported a change of treatment preference based on the RCT publication. Of the secondary outcomes, restoring anatomy was the most common response for repairing the PQ muscle. Conclusion. The majority of the orthopaedic surgeons, where a change of treatment preference was warranted based on the results and conclusion of a RCT, did not report willingness to change their treatment preference. Cite this article: Bone Joint Open 2020;1-9:549–555


Bone & Joint Research
Vol. 9, Issue 7 | Pages 429 - 439
1 Jul 2020
Tahir M Chaudhry EA Zaffar Z Anwar K Mamoon MAH Ahmad M Jamali AR Mehboob G

Aims

We hypothesized that the wide-awake local anaesthesia with no tourniquet (WALANT) technique is cost-effective, easy to use, safe, and reproducible, with a low learning curve towards mastery, having a high patient satisfaction rate. Furthermore, WALANT would be a suitable alternative for the austere and developing nation environments where lack of funds and resources are a common issue.

Methods

This was a randomized control trial of 169 patients who required surgery for closed isolated distal radius fractures. The study was performed between March 2016 and April 2019 at a public sector level 1 trauma centre. General anaesthesia was used in 56 patients, Bier’s block in 58 patients, and WALANT in 55 patients. Data were collected on pre-, peri-, and postoperative parameters, clinical outcome, hospital costs, and patient satisfaction. One-way analysis of variance (ANOVA) was used with a p-value of 0.05 being significant.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 749 - 754
1 Jun 2020
Jung H Park MJ Won Y Lee GY Kim S Lee JS

Aims

The aim of this study was to analyze the association between the shape of the distal radius sigmoid notch and triangular fibrocartilage complex (TFCC) foveal tear.

Methods

Between 2013 and 2018, patients were retrospectively recruited in two different groups. The patient group comprised individuals who underwent arthroscopic transosseous TFCC foveal repair for foveal tear of the wrist. The control group comprised individuals presenting with various diseases around wrist not affecting the TFCC. The study recruited 176 patients (58 patients, 118 controls). The sigmoid notch shape was classified into four types (flat-face, C-, S-, and ski-slope types) and three radiological parameters related to the sigmoid notch (namely, the radius curvature, depth, and version angle) were measured. The association of radiological parameters and sigmoid notch types with the TFCC foveal tear was investigated in univariate and multivariate analyses. Receiver operating characteristic curves were used to estimate a cut-off for any statistically significant variables.


Bone & Joint 360
Vol. 9, Issue 2 | Pages 33 - 37
1 Apr 2020


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1498 - 1505
1 Dec 2019
Sonntag J Woythal L Rasmussen P Branner U Hølmer P Jensen AK Lange KHW Brorson S

Aims. The aim of this study was to investigate the difference in functional outcome after repair and non-repair of the pronator quadratus muscle in patients undergoing surgical treatment for a distal radial fracture with volar plating. Patients and Methods. A total of 72 patients with a distal radial fracture were included in this randomized clinical trial. They were allocated to have the pronator quadratus muscle repaired or not, after volar locked plating of a distal radial fracture. The patients, the assessor, the primary investigator, and the statistician were blinded to the allocation. Randomization was irreversibly performed using a web application that guaranteed a secure and tamper-free assignment. The primary outcome measure was the Patient Rated Wrist Evaluation (PRWE) after 12 months. Secondary outcomes included the Disabilities of the Arm, Shoulder and Hand (DASH) score, pronation strength, grip strength, the range of pronation and supination, complications, and the operating time. Results. Of the 72 patients, 63 (87.5%) completed follow-up for the primary outcome measure: 31 (86.1%) from the non-repair group and 32 (88.9%) from the repair group. At the 12-month follow-up, the mean difference in PRWE of 5.47 (95% confidence interval (CI) -4.02 to 14.96) between the repair (mean 18.38 (95% CI 10.34 to 26.41)) and non-repair group (mean 12.90 (95% CI 7.55 to 18.25)) was not statistically significant (p = 0.253). There was a statistically significant difference between pronation strength, favouring non-repair. We found no difference in the other secondary outcomes. Conclusion. We found that repairing pronator quadratus made no difference to the clinical outcome, 12 months after volar plating of a distal radial fracture. We conclude that there is no functional advantage in repairing this muscle under these circumstances and advise against it. Cite this article: Bone Joint J 2019;101-B:1498–1505


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 124 - 131
1 Feb 2019
Isaacs J Cochran AR

Abstract

Nerve transfer has become a common and often effective reconstructive strategy for proximal and complex peripheral nerve injuries of the upper limb. This case-based discussion explores the principles and potential benefits of nerve transfer surgery and offers in-depth discussion of several established and valuable techniques including: motor transfer for elbow flexion after musculocutaneous nerve injury, deltoid reanimation for axillary nerve palsy, intrinsic re-innervation following proximal ulnar nerve repair, and critical sensory recovery despite non-reconstructable median nerve lesions.


Bone & Joint 360
Vol. 7, Issue 5 | Pages 18 - 21
1 Oct 2018


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 789 - 794
1 Jun 2014
Sukegawa K Kuniyoshi K Suzuki T Ogawa Y Okamoto S Shibayama M Kobayashi T Takahashi K

We conducted an anatomical study to determine the best technique for transfer of the anterior interosseous nerve (AIN) for the treatment of proximal ulnar nerve injuries. The AIN, ulnar nerve, and associated branches were dissected in 24 cadaver arms. The number of branches of the AIN and length available for transfer were measured. The nerve was divided just proximal to its termination in pronator quadratus and transferred to the ulnar nerve through the shortest available route. Separation of the deep and superficial branches of the ulnar nerve by blunt dissection alone, was also assessed. The mean number of AIN branches was 4.8 (3 to 8) and the mean length of the nerve available for transfer was 72 mm (41 to 106). The transferred nerve reached the ulnar nerve most distally when placed dorsal to flexor digitorum profundus (FDP). We therefore conclude that the AIN should be passed dorsal to FDP, and that the deep and superficial branches of the ulnar nerve require approximately 30 mm of blunt dissection and 20 mm of sharp dissection from the point of bifurcation to the site of the anastomosis. The use of this technique for transfer of the AIN should improve the outcome for patients with proximal ulnar nerve injuries. Cite this article: Bone Joint J 2014;96-B:789–94


Bone & Joint 360
Vol. 2, Issue 6 | Pages 20 - 21
1 Dec 2013

The December 2013 Wrist & Hand Roundup. 360 . looks at: Scapholunate instability; three-ligament tenodesis; Pronator quadratus; Proximal row carpectomy; FPL dysfunction after volar plate fixation; Locating the thenar branch of the median nerve; Metallosis CMCJ arthroplasties; and timing of flap reconstruction


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 396 - 400
1 Mar 2013
Rhee SH Kim J Lee YH Gong HS Lee HJ Baek GH

The purpose of this study was to evaluate the risk of late displacement after the treatment of distal radial fractures with a locking volar plate, and to investigate the clinical and radiological factors that might correlate with re-displacement. From March 2007 to October 2009, 120 of an original cohort of 132 female patients with unstable fractures of the distal radius were treated with a volar locking plate, and were studied over a follow-up period of six months. In the immediate post-operative and final follow-up radiographs, late displacement was evaluated as judged by ulnar variance, radial inclination, and dorsal angulation. We also analysed the correlation of a variety of clinical and radiological factors with re-displacement. Ulnar variance was significantly overcorrected (p < 0.001) while radial inclination and dorsal angulation were undercorrected when compared statistically (p <  0.001) with the unaffected side in the immediate post-operative stage. During follow-up, radial shortening and dorsal angulation progressed statistically, but none had a value beyond the acceptable range. Bone mineral density measured at the proximal femur and the position of the screws in the subchondral region, correlated with slight progressive radial shortening, which was not clinically relevant.

Volar locking plating of distal radial fractures is a reliable form of treatment without substantial late displacement.

Cite this article: Bone Joint J 2013;95-B:396–400.


Bone & Joint 360
Vol. 1, Issue 6 | Pages 17 - 18
1 Dec 2012

The December 2012 Wrist & Hand Roundup. 360. looks at: the imaging of scaphoid fractures; splinting to help Dupuytren’s disease; quality of life after nerve transfers; early failure of Moje thumbs; electra CMCJ arthroplasty; proximal interphalangeal joint replacement; pronator quadratus repair in distal radius fractures; and osteoporosis and wrist fractures


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 34 - 34
1 Sep 2012
Friedl W Singh S Anastasiu A
Full Access

Distal radius fractures are typical and frequent fracture of elderly woman with reduced bone density. Thus implant fixation is more difficult. Dorsal and radial comminution are frequent in these patients and so reduction and angle stable osteosynthesis needed. The angle stable plate, often also multidirectional is today the most common stabilisation device. Because of the introduction of bulky and bended implants as the Micronail or Targon DR wich require difficult opening of the bone with awles we decided to test the XS radius nail witch is a 4,5mm or 3,5mm straight nail and witch is introduced after guide wire placement and over drilling with a canulated drill of the same diameter. It is locked parallel to the joint in 3 different directions with angular stability with threaded wires. Methods 16 radius sawbones were osteotomised corresponding to a A3 Fracture and stabilised with a angle stable plate (8) and XS nail (8). 1000 alternating load cycles from 20–200N were performed and the deformation was registered. Also a FE analysis with the MSC Patran/Marc softwere were performed. Also the calculated deformation in the FE study was 20% lower. Also deformation amplitude was lower with 0.31mm compared to 0.42mm in the plate group. The differences however were not significant. Both devices show good biomechanical results. The XS nail has the advantage of mainly intraosseus position, simple operation technique with introduction over a guide wire from the proc. Styloideus radii and over drilling with a canulated drill of the same size. The exposure of the N rad. superf. must be performed. First clinical evaluation is presented. Due to the results we developed a anatomically adapted XS radius nail. The results of the first 100 patients are presented. Conclusions. Both angular stable plate and XSR nail can be used in unstable distal radius fracture fixation. The mainly intraosseus position of the nail and saving of the pronator quadratus as well as lower deformation are in favour of the XSR nail. However frontal plane fractures and very comminuted fractures are better treated with a multidirectional locking plate due to technical reasones so that we use the XSR nail mainly in A3 and C1 fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1090 - 1096
1 Aug 2012
Mahmoud M El Shafie S Kamal M

Malunion is the most common complication of the distal radius with many modalities of treatment available for such a problem. The use of bone grafting after an osteotomy is still recommended by most authors. We hypothesised that bone grafting is not required; fixing the corrected construct with a volar locked plate helps maintain the alignment, while metaphyseal defect fills by itself. Prospectively, we performed the procedure on 30 malunited dorsally-angulated radii using fixed angle volar locked plates without bone grafting. At the final follow-up, 22 wrists were available. Radiological evidence of union, correction of the deformity, clinical and functional improvement was achieved in all cases. Without the use of bone grafting, corrective open wedge osteotomy fixed by a volar locked plate provides a high rate of union and satisfactory functional outcomes.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 56 - 56
1 May 2012
Patel M O'Donnell T
Full Access

Increased use of locking volar plates for distal radius fractures led to a number of reports in literature of flexor tendon injuries from impingement and attrition against hardware. Repair of the pronator quadratus is critical in preventing tendon injury. We present a pronator quadratus sparing approach to the distal radius. The senior author has used a pronator quadratus sparing lateral pillar approach for for the past five years. A lateral incision is used over the radial styloid. The first dorsal compartment is released and APL and EPB tendons retracted. The underlying brachio-radialis tendon and insertion fascia is split and the palmar portion elevated off the distal radius with the pronator quadratus as a single contiguous sheet. The distal edge of the pronator quadratus is elevated from the wrist capsule by sharp dissection. The radial artery is protected by the retracted tissue. Repair of the brachio-radialis tendon and insertion fascia is much more robust than that of the pronator quadratus covering the entire plate. Since 2004, the senior author has used the pronator quadratus sparing approach for volar plating of the distal radius, in 183 cases. At last follow-up there were no instances of flexor tendon injury, which was considered to be one of the outcome measures and end-points. There was no impingement in the first dorsal compartment, except in two cases of lateral pillar hardware impingement from additional lateral pillar plate fixation through the same approach. Nine cases had minor persistent superficial radial nerve parasthesia. One case had a superficial wound infection requiring drainage. The repaired pronator quadratus formed a barrier protecting the plate. The infection was aggressively treated and the plate left in situ for three months till fracture union. Cultures from the retrieved plate showed no organisms. Another implant had two of the locking screws back out. The pronator quadratus fascia was tented with an underlying haematoma. The fascia however only showed minimum screw penetration and no flexor tendon injury. Average wrist dorsiflexion was 72 deg and palmar flexion 65 deg. Average pronation was 81 deg and average supination 69 deg. Supination range was slow to recover in younger patients. One explanation could be the tight pronator quadratus repair. Average PRWE and DASH scores were 19. The quadratus sparing approach to the volar distal radius is easy to perform and protects the flexor tendons at the wrist. Cases demonstrated that an intact pronator quadratus can act as an effective barrier to prominent hardware and superficial infection. Supination range may be reduced by this approach due to a tight repair, though a palmar DRUJ capsule contracture may also be an explanation


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 222 - 226
1 Feb 2012
Rodrigues-Pinto R Freitas D Costa LD Sousa R Trigueiros M Lemos R Silva C Oliveira A

Radial osteotomy is currently advocated for patients with Lichtman’s stages II and IIIA of Kienböck’s disease; its place in the treatment of patients with stage IIIB disease remains controversial. The purpose of this study was to evaluate the medium-term results of this procedure and to compare the outcome in patients with stage IIIB disease and those with earlier stages (II and IIIA). A total of 18 patients (18 osteotomies) were evaluated both clinically and radiologically at a mean follow-up of 10.3 years (4 to 18). Range of movement, grip strength and pain improved significantly in all patients; the functional score (Nakamura Scoring System (NSSK)) was high and self-reported disability (Disabilities of Arm, Shoulder and Hand questionnaire) was low at the final follow-up in all patients evaluated. Patients with stage IIIB disease, however, had a significantly lower grip strength, lower NSSK scores and higher disability than those in less advanced stages. Radiological progression of the disease was not noted in either group, despite the stage. Radial osteotomy seems effective in halting the progression of disease and improving symptoms in stages II, IIIA and IIIB. Patients with less advanced disease should be expected to have better clinical results.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 525 - 526
1 Nov 2011
Chirpaz-Cerbat J Ruatti S
Full Access

Purpose of the study: Defective reduction and secondary displacement after osteosynthesis of distal radius fractures can compromise wrist function. Volar locking plates enable solid fixation which remains stable over time but section of the pronator quadrates necessary for the anterior approach raises the risks of destabilising the distal radioulnar joint and loss of pronation force. Our study was designed to evaluate recovery of grip, pronation and supination force after volar locking plate fixation. Material and methods: This was a prospective study of 29 fractures of the distal radius with dorsal displacement fixed with a volar locking plate in 28 patients (17 men, 11 women, mean age 48.75 years) from January 2007 to May 2008. The quality of the pronator quadrates suture was assessed at the end of the operation. The assessment included the classical parameters of wrist movement, the Herzberg and Dumontier score, radial slope and ulnar variance on the ap and lateral views of the wrist, and recovery of grip, pronation and supination force compared with the opposite side using an ambulatory device. Results: The pronator quadratus suture was considered solid in eight cases, precarious in seven. Complete suture was not possible in 14 cases. At mean follow-up of 10 months, patients had on average recovered 77% of the grip force, 74% of the pronation force, and 76% of supination force, compared with the opposite side. Complications included one defective reduction, one secondary displacement (by defective plate position), two dystrophy syndromes, and four posttrauma carpal tunnel syndromes. Discussion: The literature shows that volar plate fixation enables recovery of 74% to 84% of grip force. Few studies have examined the recovery of pronosupination and none have described results after osteosynthesis for fracture. Our study did not find that section of the pronator quadrates, a muscle difficult to suture, had a deleterious effect. Conclusion: Osteosynthesis using a volar locking plate for distal fractures of the radius remains a controversial issue. Study of recovery of the grip, pronation and supination force did not reveal any prejudice attributable to this technique