Introduction. Ink engineering can advance 3D-printability for better therapeutics, with optimized proprieties. Herein, we describe a methodology for yielding 3D-printable
In cartilage tissue engineering (TE),new solutions are needed to effectively drive chondrogenic differentiation of mesenchymal stromal cells in both normal and inflammatory milieu. Ultrasound waves represent an interesting tool to facilitate chondrogenesis. In particular, low intensity pulsed ultrasound (LIPUS)has been shown to regulate the differentiation of adipose mesenchymal stromal cells. Hydrogels are promising biomaterials capable of encapsulating MSCs by providing an instructive biomimetic environment, graphene oxide (GO) has emerged as a promising nanomaterial for cartilage TE due to its chondroinductive properties when embedded in polymeric formulations, and piezoelectric nanomaterials, such as barium titanate nanoparticles (BTNPs),can be exploited as nanoscale transducers capable of inducing cell growth/differentiation. The aim of this study was to investigate the effect of dose-controlled LIPUS in counteracting inflammation and positively committing chondrogenesis of ASCs embedded in a 3D piezoelectric hydrogel. ASCs at 2*10. 6. cells/mL were embedded in a 3D VitroGel RGD. ®. hydrogel without nanoparticles (Control) or doped with 25 µg/ml of GO nanoflakes and 50 µg/ml BTNPs.The hydrogels were exposed to basal or inflammatory milieu (+IL1β 10ng/ml)and then to LIPUS stimulation every 2 days for 10 days of culture. Hydrogels were chondrogenic differentiated and analyzed after 2,10 and 28 days. At each time point cell viability, cytotoxicity, gene expression and immunohistochemistry (COL2, aggrecan, SOX9, COL1)and inflammatory cytokines were evaluated. Ultrasound stimulation significantly induced chondrogenic differentiation of ASCs loaded into 3D piezoelectric hydrogels under basal conditions: COL2, aggrecan and SOX9 were significantly overexpressed, while the fibrotic marker COL1 decreased compared to control samples. LIPUS also has potent anti-inflammatory effects by reducing IL6 and IL8 and maintaining its ability to boost chondrogenesis. These results suggest that the combination of LIPUS and piezoelectric hydrogels promotes the differentiation of ASCs encapsulated in a 3D hydrogel by reducing the inflammatory milieu, thus representing a promising tool in the field of cartilage TE. Acknowledgements: This work received funding from the European Union's Horizon 2020 research and innovation program, grant agreement No 814413, project ADMAIORA (AdvanceD
Biofilm-related infection is a major complication that occurs in orthopaedic surgery. Various treatments are available but efficacy to eradicate infections varies significantly. A systematic review was performed to evaluate therapeutic interventions combating biofilm-related infections on in vivo animal models. Literature research was performed on PubMed and Embase databases. Keywords used for search criteria were “bone AND biofilm”. Information on the species of the animal model, bacterial strain, evaluation of biofilm and bone infection, complications, key findings on observations, prevention, and treatment of biofilm were extracted.Aims
Methods
Aim. To develop a new system for antibacterial coating of joint prosthesis and osteosynthesis material. The new coating system was designed to release gentamicin immediately after insertion to eradicate surgical contamination. Method. Steel implants (2×15mm) were coated with a solid
A novel injectable hydrogel based on DNA and silicate nanodisks was fabricated and optimized to obtain a suitable drug delivery platform for biomedical applications. Precisely, the hydrogel was designed by combining two different type of networks: a first network (type A) made of interconnections between neighboring DNA strands and a second one (type B) consisting of electrostatic interactions between the silicate nanodisks and the DNA backbone. The silicate nanodisks were introduced to increase the viscosity of the DNA physical hydrogel and improve their shear-thinning properties. Additionally, the silicate nanodisks were selected to modulate the release capability of the designed network. DNA 4% solutions were heated at 90°C for 45 seconds and cooled down at 37°C degree for two hours. In the second step, the silicate nanodisks suspension in water at different concentrations (0.1 up to 0.5%) were then mixed with the pre-gel DNA hydrogels to obtain the
Introduction. Intervertebral disc degeneration (IVDD) associated with low back pain is a major contributor to global disability. Current treatments are poorly efficient in the long-term resulting in medical complications. Therefore, minimally invasive injectable therapies are required to repopulate damaged tissues and aid regeneration. Among injectable biomaterials, self-assembling peptide hydrogels (SAPHs) represent potential candidates as 3D cell carriers. Moreover, the advent of graphene-related materials has opened the route for the fabrication of graphene-containing hydrogel
Injectable hydrogels via minimally invasive surgery reduce the risk of infection, scar formation and the cost of treatment. Degradation of the intervertebral disc (IVD) currently has no preventative treatment. An injectable hydrogel material could restore disc height, reinforce local mechanical properties, and promote tissue regeneration. We present a hydrogel material Laponite® associated poly(N-isopropylacrylamide)-co-poly(dimethylacrylamide) (NPGel). Understanding how the components of this hydrogel system influence material properties, is crucial for tailoring treatment strategies for the IVD and other tissues. The effect of hydrogel wt./wt., clay and co-monomer percentages were assessed using a box-Behnken design. Rheometry, SEM, FTIR and swelling was used to measure changes in material properties in simulated physiological conditions. Rheometry revealed gelation temperature of hydrogel materials could be modified with dimethyl-acrylamide co-monomer; however, final maximum mechanical properties remained unaffected. Increasing the weight % and clay % increased resultant mechanical properties from ∼500–2500 G' (Pa), increased viscosity, but retained the ability to flow through a 26G needle at 39°C.Introduction
Methods & Results
Total joint replacement (TJR), such as hip and knee replacement, is commonly used for the treatment of end stage arthritis. The use of Poly (methylmethacrylate) bone cement is a gold standard in such replacement, where it fixes the implant in place and transfer stresses between bone and implant, and frequently used for local delivery of drugs such as antibiotics. The use of antibiotic loaded bone cement is considered a well-established standard in the treatment and prophylaxis of Prosthetic joint infections (PJI). PJIs is a serious problem that decreases success rate of surgery and can be life threatening to patients, where the incidence can reach up 2% in total and hip replacements and up to 40% for revision surgery. Currently used antibiotic loaded bone cements have many limitations, including burst release of < 10% of antibiotic added. This burst release falls rapidly below inhibitory level within few days, which leads to selection of resistant antimicrobial strains and does not provide prophylaxis from early and delayed stage infection. This study aims to provide a controlled release for gentamicin when loaded on Silica nanoparticles (NP) using layer-by-layer technique (LbL) to provide prophylaxis and treatment from postsurgical infections. The gentamicin loaded NPs were incorporated into PMMA bone cement and the new
Calcium phosphate ceramics and bioactive glasses are frequently used in orthopedic surgery to stimulate the regeneration of bone tissue due to their superior compatibility to bone tissue. Nevertheless, the brittleness and lack of self-healing behavior of bioceramics are still considered as serious drawbacks. Therefore, these bioceramics have been combined with organic biomaterials for several decades. Since the 1990s, the emergence of nanotechnology has accelerated the progress with respect to the development of organic-inorganic
The enhancement of current bone cement properties is a challenging issue that has been the focus of much research. Developing bone composites with high level of cytocompatibility, mechanical and antibacterial properties is a challenging task. We overcome this challenge by designing a
Summary Statement. Innovative
Nanotechnology is the study, production and controlled
manipulation of materials with a grain size <
100 nm. At this
level, the laws of classical mechanics fall away and those of quantum
mechanics take over, resulting in unique behaviour of matter in
terms of melting point, conductivity and reactivity. Additionally,
and likely more significant, as grain size decreases, the ratio
of surface area to volume drastically increases, allowing for greater interaction
between implants and the surrounding cellular environment. This
favourable increase in surface area plays an important role in mesenchymal
cell differentiation and ultimately bone–implant interactions. Basic science and translational research have revealed important
potential applications for nanotechnology in orthopaedic surgery,
particularly with regard to improving the interaction between implants
and host bone. Nanophase materials more closely match the architecture
of native trabecular bone, thereby greatly improving the osseo-integration
of orthopaedic implants. Nanophase-coated prostheses can also reduce
bacterial adhesion more than conventionally surfaced prostheses.
Nanophase selenium has shown great promise when used for tumour
reconstructions, as has nanophase silver in the management of traumatic
wounds. Nanophase silver may significantly improve healing of peripheral
nerve injuries, and nanophase gold has powerful anti-inflammatory
effects on tendon inflammation. Considerable advances must be made in our understanding of the
potential health risks of production, implantation and wear patterns
of nanophase devices before they are approved for clinical use.
Their potential, however, is considerable, and is likely to benefit
us all in the future. Cite this article:
Objectives. There is increasing application of bone morphogenetic proteins
(BMPs) owing to their role in promoting fracture healing and bone
fusion. However, an optimal delivery system has yet to be identified.
The aims of this study were to synthesise bioactive BMP-2, combine
it with a novel α-tricalcium phosphate/poly(D,L-lactide-co-glycolide)
(α-TCP/PLGA)
Introduction. The annual incidence of fractures in the UK is almost 4%. Bone grafting procedures and segmental bone transport have been employed for bone tissue regeneration. However, their limited availability, donor site morbidity and increased cost mean that there is still a large requirement for alternative methods and there is considerable research into regeneration using bone morphogenetic proteins (BMPs). The aims of this study are to synthesise and combine BMP-2 with a novel
Several bisphosphonates are now available for the treatment of osteoporosis. Porous hydroxyapatite/collagen (HA/Col) composite is an osteoconductive bone substitute which is resorbed by osteoclasts. The effects of the bisphosphonate alendronate on the formation of bone in porous HA/Col and its resorption by osteoclasts were evaluated using a rabbit model. Porous HA/Col cylinders measuring 6 mm in diameter and 8 mm in length, with a pore size of 100 μm to 500 μm and 95% porosity, were inserted into a defect produced in the lateral femoral condyles of 72 rabbits. The rabbits were divided into four groups based on the protocol of alendronate administration: the control group did not receive any alendronate, the pre group had alendronate treatment for three weeks prior to the implantation of the HA/Col, the post group had alendronate treatment following implantation until euthanasia, and the pre+post group had continuous alendronate treatment from three weeks prior to surgery until euthanasia. All rabbits were injected intravenously with either saline or alendronate (7.5 μg/kg) once a week. Each group had 18 rabbits, six in each group being killed at three, six and 12 weeks post-operatively. Alendronate administration suppressed the resorption of the implants. Additionally, the mineral densities of newly formed bone in the alendronate-treated groups were lower than those in the control group at 12 weeks post-operatively. Interestingly, the number of osteoclasts attached to the implant correlated with the extent of bone formation at three weeks. In conclusion, the systemic administration of alendronate in our rabbit model at a dose-for-weight equivalent to the clinical dose used in the treatment of osteoporosis in Japan affected the mineral density and remodelling of bone tissue in implanted porous HA/Col composites.
The use of mesenchymal stem cells (MSCs) for cartilage and bone tissue engineering needs to be supported by scaffolds that may release stimuli for modulate cell activity. The objective of this study was to asses if MSC undergo differentiation when cultured upon a membrane of nanofibers of poly-L-lactic acid loaded with hydroxyapatite nanoparticles (PLLA/HAp). The PLLA/HAp
Aims: to investigate the mechanical properties of a new