Advertisement for orthosearch.org.uk
Results 1 - 13 of 13
Results per page:
Bone & Joint Open
Vol. 3, Issue 9 | Pages 733 - 740
21 Sep 2022
Sacchetti F Aston W Pollock R Gikas P Cuomo P Gerrand C

Aims. The proximal tibia (PT) is the anatomical site most frequently affected by primary bone tumours after the distal femur. Reconstruction of the PT remains challenging because of the poor soft-tissue cover and the need to reconstruct the extensor mechanism. Reconstructive techniques include implantation of massive endoprosthesis (megaprosthesis), osteoarticular allografts (OAs), or allograft-prosthesis composites (APCs). Methods. This was a retrospective analysis of clinical data relating to patients who underwent proximal tibial arthroplasty in our regional bone tumour centre from 2010 to 2018. Results. A total of 76 patients fulfilled the inclusion criteria and were included in the study. Mean age at surgery was 43.2 years (12 to 86 (SD 21)). The mean follow-up period was 60.1 months (5.4 to 353). In total 21 failures were identified, giving an overall failure rate of 27.6%. Prosthesis survival at five years was 75.5%, and at ten years was 59%. At last follow-up, mean knee flexion was 89.8° (SD 36°) with a mean extensor lag of 18.1° (SD 24°). In univariate analysis, factors associated with better survival of the prosthesis were a malignant or metastatic cancer diagnosis (versus benign), with a five- and ten-year survival of 78.9% and 65.7% versus 37.5% (p = 0.045), while in-hospital length of stay longer than nine days was also associated with better prognosis with five- and ten-year survival rates at 84% and 84% versus 60% and 16% (p < 0.001). In multivariate analysis, only in-hospital length of stay was associated with longer survival (hazard ratio (HR) 0.23, 95% confidence interval (CI) 0.08 to 0.66). Conclusion. We have shown that proximal tibial arthroplasty with endoprosthesis is a safe and reliable method for reconstruction in patients treated for orthopaedic oncological conditions. Either modular or custom implants in this series performed well. Cite this article: Bone Jt Open 2022;3(9):733–740


Bone & Joint Open
Vol. 2, Issue 6 | Pages 371 - 379
15 Jun 2021
Davies B Kaila R Andritsos L Gray Stephens C Blunn GW Gerrand C Gikas P Johnston A

Aims

Hydroxyapatite (HA)-coated collars have been shown to reduce aseptic loosening of massive endoprostheses following primary surgery. Limited information exists about their effectiveness in revision surgery. The aim of this study was to radiologically assess osteointegration to HA-coated collars of cemented massive endoprostheses following revision surgery.

Methods

Retrospective review of osseointegration frequency, pattern, and timing to a specific HA-coated collar on massive endoprostheses used in revision surgery at our tertiary referral centre between 2010 to 2017 was undertaken. Osseointegration was radiologically classified on cases with a minimum follow-up of six months.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 75 - 75
1 May 2017
Koris J Blunn G Coathup M
Full Access

Background. Children suffering from primary bone cancer necessitating resection of growth plates, may suffer progressive leg length discrepancy, which can be attenuated with extendable prostheses. A serious complication is catastrophic implant failure. Over time, bone will remodel, altering the stress pattern in the implant. By using finite element analysis we can model different bone remodeling conditions to ascertain the effect that this will have on stress distribution and magnitude. A finite element analysis was performed. Simplified computer generated models were designed of a cemented femoral Stanmore growing massive endoprosthesis. Three scenarios were designed, modelled on post-operative radiographs. Scenario 1 had a gap between the end of the femur and the implant collar, scenario 2 had no gap, but with no bone attachment into the collar, and scenario 3 had growth of the bone over the length of the collar with attachment. Physiological loading conditions were applied. The resultant stress in the implant for each scenario was measured, and compared to the strength of the material. Peak stresses were recorded at the stem-collar junction. The maximum stress recorded in the implant in scenario 1 was 3104.2Mpa, compared to 1054.4Mpa in scenario 2, and 321.2Mpa in scenario 3. Conclusions. Both accurate reduction and bone growth with attachment to the stem of a massive endoprosthesis will greatly reduce the resultant stress in the implant under loading conditions. The load is redistributed throughout the length of the bone. This may help to prevent catastrophic failure in the implant under loading conditions. Further investigations of patient findings are needed to ensure the model findings are verified. Level of Evidence. IIb (Theoretical)


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 263 - 269
1 Feb 2014
Batta V Coathup MJ Parratt MT Pollock RC Aston WJ Cannon SR Skinner JA Briggs TW Blunn GW

We reviewed the outcome of 69 uncemented, custom-made, distal femoral endoprosthetic replacements performed in 69 patients between 1994 and 2006. There were 31 women and 38 men with a mean age at implantation of 16.5 years (5 to 37). All procedures were performed for primary malignant bone tumours of the distal femur. At a mean follow-up of 124.2 months (4 to 212), 53 patients were alive, with one patient lost to follow-up. All nine implants (13.0%) were revised due to aseptic loosening at a mean of 52 months (8 to 91); three implants (4.3%) were revised due to fracture of the shaft of the prosthesis and three patients (4.3%) had a peri-prosthetic fracture. Bone remodelling associated with periosteal cortical thinning adjacent to the uncemented intramedullary stem was seen in 24 patients but this did not predispose to failure. All aseptically loose implants in this series were diagnosed to be loose within the first five years.

The results from this study suggest that custom-made uncemented distal femur replacements have a higher rate of aseptic loosening compared to published results for this design when used with cemented fixation. Loosening of uncemented replacements occurs early indicating that initial fixation of the implant is crucial.

Cite this article: Bone Joint J 2014;96-B:263–9.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 110 - 110
1 Sep 2012
Perera J Griffiths D Gikas P Perera J Donaldson J Aston W Pollock R Skinner J Cannon S Briggs T
Full Access

Sixty eight consecutive patients underwent proximal humeral replacement with a fixed fulcrum massive endoprosthesis, for tumour, between 1997 and 2007. The mean age was 46 years, (7–87). Ten patients were lost to follow up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumour Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS). The mean MSTS score was 72.3% and the mean TESS was 77.2%. Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This sub group of 4 patients had a mean MSTS score of 77.7% and a mean TESS of 80.0%. Endoprosthetic replacement for tumour of the proximal humerus using this prosthesis is a reliable operation yielding good functional results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with the new constrained humeral liner


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 113 - 113
1 Sep 2012
Sankar B Refaie R Murray S Gerrand C
Full Access

Introduction. Aseptic loosening is the most common mode of failure of massive endoprostheses. Introduction of Hydroxyapatite coated collars have reduced the incidence of aseptic loosening. However bone growth is not always seen on these collars. Objectives. The aims of our study were to determine the extent of osseous integration of Hydroxyapatite coated collars, attempt a grading system for bone growth and to determine the effect of diagnosis, surgical technique and adjuvant therapy on bone growth. Methods. We reviewed the records and radiographs of 58 patients who had a massive endoprosthesis implanted by two surgeons in our unit over the last five years. Revision surgeries were recorded separately. Bone growth was graded 1–4 based on appearance in antero-posterior and lateral radiographs. Results. Three groups were identified. Group 1-Resections for primary bone tumours (33 patients), Group 2-resections for metastatic bone disease (22 patients) and Group 3- Resections for non tumour indications (3 patients). Overall, 60% of patients had grade 1, 12% had grade 2, 19% had grade 3 and 9% had grade 4 osteointegration. Grade 3 or 4 Collar osteointegration was found in 37% of patients in Group 1, 9% in group 2 and 67% in group 3. 5% of patients with grade 1 integration, 100% patients with grade 2 integration and none of the patients with grade 3 or 4 integration underwent revision for aseptic loosening. Appearance or widening of a gap between the resected bone end and the collar indicated loosening and impending revision. Proximal humeral replacements had the lowest rate of osteointegration (12%). Adjuvant therapy did not affect osteointegration. Conclusion. Osteointegration of collars is seen more often after resection of primary bone tumours. The role of collars in metastatic tumour surgery is questionable. Our radiographic grading system of bone growth predicted aseptic loosening


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 16 - 16
1 Jul 2012
Perera J Gikas P Griffiths D Donaldson J Aston W Pollock R Skinner J Cannon S Briggs T
Full Access

Sixty eight consecutive patients underwent proximal humeral replacement with a fixed fulcrum massive endoprosthesis for tumour between 1997 and 2007. The mean age was 46 years (7-87). Ten patients were lost to follow up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumour Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS). The mean MSTS score was 72.3 % and the mean TESS was 77.2 %. Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This sub group of 4 patients had a mean MSTS score of 77.7 % and a mean TESS of 80.0%. Endoprosthetic replacement for tumour of the proximal humerus using this prosthesis is a reliable operation yielding good functional results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with the new constrained humeral liner


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 399 - 403
1 Mar 2011
Griffiths D Gikas PD Jowett C Bayliss L Aston W Skinner J Cannon S Blunn G Briggs TWR Pollock R

Between 1997 and 2007, 68 consecutive patients underwent replacement of the proximal humerus for tumour using a fixed-fulcrum massive endoprosthesis. Their mean age was 46 years (7 to 87). Ten patients were lost to follow-up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumor Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS) at a mean follow-up of five years and 11 months (one year to ten years and nine months). The mean MSTS score was 72.3% (53.3% to 100%) and the mean TESS was 77.2% (58.6% to 100%). Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This subgroup had a mean MSTS score of 77.7% and a mean TESS of 80.0%. The dislocation rate for the original prosthesis was 25.9; none of the patients with the new liner had a dislocation at a mean of 14.5 months (12 to 18). Endoprosthetic replacement for tumours of the proximal humerus using this prosthesis is a reliable operation yielding good results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with a new constrained humeral liner, which reduces the risk of dislocation


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 815 - 819
1 Jun 2009
Spiegelberg BGI Sewell MD Coltman T Blunn GW Flanagan AM Cannon SR Briggs TWR

We report a case which highlights the progression of osteofibrous dysplasia to adamantinoma and questions whether intralesional curettage is the appropriate treatment. The role of a joint-sparing massive endoprosthesis using cortical fixation is demonstrated and we describe a unique biomedical design which resulted in the manufacture of an end cap to allow amputation through a custom-made proximal tibial replacement, rather than an above-knee amputation following recurrence


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 403 - 403
1 Jul 2008
Paniker J Abudu A Carter S Tillman R Grimer R
Full Access

Purpose: To study the results of treatment of symptomatic non-union with endoprosthesis at the Royal Orthopaedic Hospital. Methods: Between 1987 & 2005, 17patients were treated with massive endoprosthesis for non-union. We performed a retrospective review of these case notes. Results: Mean age at diagnosis was 63years (range 36–86). Location of non-union was distal femur in 9, proximal femur in 4, proximal humerus in 2, proximal tibia in 1, distal humerus in 1. The majority of the patients had received prior multiple operations before endoprosthetic surgery. Four patients had obvious infection confirmed by histology and/or microbiology prior to surgery. Endoprosthetic Reconstruction was performed as a 1 stage procedure in 13 and as a 2 stage in 4. Complications occurred in 5 patients. These included recurrence of infection in 1, persistent pain in 1, aseptic loosening in 1, periprosthetic fracture in 1 and a non ST myocardial infarction in 1. At the last follow-up, (mean 5years, range 1–18years) majority of patients achieved good range of motion and good mobility. Conclusion: We conclude that endoprosthetic replacement is a reasonable option for treatment of end-stage non-union in carefully selected patients. Adequate mobility and function can be achieved in majority of patients following such treatment


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 392 - 392
1 Oct 2006
Kalia P Bhalla A Coathup M Miller J Goodship A Blunn G
Full Access

Introduction: The survival of massive endoprosthesis replacements is not as successful as conventional joint replacements. The main cause of failure of these implants is aseptic loosening. Bone in-growth onto the implant collar on the shaft of the prosthesis adjacent to the transaction site has been correlated with a decrease in radiolucent lines adjacent to the intramedullary stem and reduced implant loosening. We propose that bone contact and in-growth to the collar may be further enhanced with tissue engineering techniques. The hypothesis of this study was that autologous mesenchymal stem cells (MSCs) suspended within fibrin glue and sprayed onto hydroxyapatite (HA)-coated collars of massive prosthesis will augment bone growth and contact to the implant in an ovine model. Materials and Methods: MSCs were isolated and expanded in vitro from the iliac crest of six adult sheep. Pre-implantation, 2 x 106 autologous MSCS were suspended in thrombin. During surgery, this mixture was combined with fibrinogen and sprayed onto the proximal and distal HA-coated collars of tibial midshaft prostheses using pressurized air. The implants were cemented into the right hind limb of twelve sheep, six of which received MSCs. Radiographs were taken at 2, 4 and 6 months and bone area within defined regions quantified using image analysis software. After six months, specimens were retrieved and processed for undecalcified histology. Transverse thin sections were prepared through the centre of each collar. Image analysis was used to quantify bone area and contact. Mann Whitney U tests were used for comparative statistical analysis, where p< 0.05 was classified as significant. Results: Anterior-posterior (AP) radiographs taken at 2, 4, and 6 months showed that animals treated with MSCs produced more bone adjacent to the shaft of the implant. Analysis of bone area on both AP and medio-lateral (ML) radiographs taken after sacrifice showed that stem cell-treated implants encouraged significantly more total bone around the implants at 6 months than the control group (171.94 ± 29.04 mm2, and 87.51 ± 9.81 mm2 bone area, respectively, p = 0.016). Analysis of histological sections shows a significant increase in bone area around midshafts treated with MSCs, compared to the implant controls (53.99 ± 10.64 mm2, and 21.07 ± 7.34 mm2, respectively; p = 0.020). The average surface area contact between the midshaft and bone was almost doubled in the MSC-implant group (19.83 ± 8.73 % contact) than in the control group (8.667 ± 8.667 %, p = 0.196). In the MSC group bone was seen deep within the grooves of the HA coated collar whilst a fibrous soft tissue layer separated the newly formed bone in the control group. Conclusion: Bone contact and in-growth to massive endoprostheses was significantly improved by spraying the implant with autologous MSCs suspended in fibrin glue. Enhanced fixation using stem cells may help prevent aseptic loosening in these massive implants


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 348 - 348
1 Mar 2004
Ashwood N Cobb J Robbins G Blunn G
Full Access

Massive cemented endoprosthesis are used to enable early resumption of activity after tumour surgery. The longevity of the prosthesis varies with anatomical site, pros-thesis type, and mode of þxation. Revision surgery will be required in approximately 50% of cases of endopros-thetic replacements around the knee by 10 years because of aseptic loosening. Insertion of a second cemented endoprosthesis is a challenge because of the poor quality of the remaining bone and loosening recurs quickly. The use of extracortical plate þxation in joint sparing surgery where the remaining bone after tumour resection will not accept an intramedullary stem is also described. The þrst series of 14 patients with extracortical plate þxation in difþcult revision or joint-sparing tumour surgery with a mean follow-up of 5 years are described. The three-plate design incorporates well within a remodelled cortex to achieve osseomechanical integration with all patients regaining their premorbid level of function within 5 months. At 5 years the Enneking scores averaged 27.3. One revision was required in a femoral replacement because of loosening. It was possible to insert a new endo-prosthesis as the intramedullary bone had reconstituted. The preliminary results suggest that this technique may provide an easy, biomechanically friendly alternative to a device with an intramedullary stem, which has a shorter lifespan in revision tumour surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 865 - 869
1 Aug 2002
Wicart P Mascard E Missenard G Dubousset J

Failure of massive knee endoprostheses implanted for malignant tumours of the distal femur in children presents a difficult problem. We present the results of rotationplasty undertaken under these circumstances in four boys. They had been treated initially at a mean age of 9.5 years for a stage-IIB malignant tumour of the distal femur by resection and implantation of a massive knee endoprosthesis. After a mean period of eight years and a mean of four operative procedures, there was failure of the endoprosthesis because of aseptic loosening in two and infection in two. Function was poor with a mean Musculoskeletal Tumor Society score of 7.5/30, and considerable associated psychological problems. At a mean follow-up of 4.5 years after rotationplasty there was excellent function with a mean score of 27.5/30 and resolution of the psychological problems