Aim. We prospectively evaluated four different microbiological tools for diagnostics of prosthetic joint infections (PJI), and assessed their impact on the categorization of infection according to EBJIS guidelines. We compared culture, in-house real-time mPCR for S. aureus, S. lugdunensis, S. hominis, S. epidermidis, S. capitis, S. haemolyticus, C. acnes (mPCR), broad-spectrum PCR (Molzym) with 16S rRNA V3-V4 amplicon Sanger sequencing (16S PCR), and 16S rRNA V3-V4 amplicon next-generation sequencing (16S NGS) on MiSeq (Ilumina). Methods. A total of 341 samples (sonication fluid, tissue biopsy, synovial fluid) were collected from 32 patients with suspected PJI who underwent 56 revision surgeries at the Orthopaedic Centre University Hospital Ljubljana, between 2022 and 2024. Samples were processed using standard protocols for routine culture, followed by DNA isolation using the MagnaPure24 (Roche). All samples were tested with mPCR, and an additional ≥4 samples from each revision (244 in total) were subjected to further metagenomic analysis. Culture results were considered positive if the same microorganism was detected in ≥2 samples, ≥50 CFU/ml were present in the sonication fluid, or ≥1 sample was positive for a more virulent microorganism or if the patient had received antibiotic treatment. Results. Each tool demonstrated high sensitivity for correct EBJIS categorization (100% culture and 16S NGS, 96.88% mPCR and 16S PCR). The highest specificity was observed with mPCR and 16S PCR (87.5%), while culture (79.17%) and NGS (37.5%) showed lower specificity. In 27% (15/56) of revisions, all microbiological tests were negative, although infection was confirmed with histology in one case, and four cases were classified as infection-likely based on clinical signs. In 20% (11/56) of cases, all microbiological tests were positive; in three cases a combination of other EBJIS criteria (without microbiology) categorized the episodes as infection-likely and one as infection-unlikely, emphasizing the importance of microbiological tests in diagnostic criteria. In 43% (24/56) of revisions categorized as infection-unlikely using a combination of other EBJIS criteria, five had positive culture, and three had positive mPCR and 16S PCR. Fifteen (62%) had positive 16S NGS, 12 due to a low number of reads, which may indicate low-grade infection or possible contamination. Conclusion. To date, no test can be established as the ultimate gold standard. The lack of
Aim. To date, no ultimate diagnostic gold standard for prosthetic joint infections (PJI) has been established. In recent years, next generation sequencing (NGS) has emerged as a promising new tool, especially in culture-negative samples. In this prospective study, we performed metagenomic analysis using 16S rRNA V3-V4 amplicon NGS in samples from patients with suspected PJI. Methods. A total of 257 (187 culture-negative (CN) and 70 culture-positive (CP)) prospectively collected tissues and sonication fluid from 32 patients (56 revisions) were included. 16S rRNA V3-V4 amplicons were sequenced using Illumina's MiSeq (California, USA) followed by bioinformatic analysis using nf-core/ampliseq pipeline. Results. We successfully sequenced 255 samples and detected a total of 105 microorganisms. These were mainly environmental microorganisms present in a small number of reads (≤100), indicating possible contamination. Pseudomonas spp. (non-aeruginosa species) was detected most frequently in 73% (187/255) of samples. The test showed limitations in species classification and identified microorganisms mainly at genus level. Significant differences in the number of reads were observed when comparing CN (≤100) and CP (≥1000) samples. In two CP, no bacteria were identified with sequencing, which is probably due to low bacterial load (1 CFU. Haemophilus spp. was detected with a significant number of reads (≥10000) in five samples from a single patient, in whom infection was considered likely according to EBJIS criteria, changing it to confirmed infection. Staphylococcus spp. was identified with ≥10000 reads in two CNs from an individual who was receiving antibiotic treatment at the time, had clinical signs of infection, and had a confirmed infection with S. lugdunensis one month earlier. Cutibacterium spp. with 36% (93/257) and Staphylococcus spp. with 34% (87/257) were detected with a minimal number of reads (≤100) in several CN, indicating possible contamination with normal skin microbiota. In one patient, Facklamia spp., an opportunistic pathogen, was detected in two samples by sequencing, but not by culture. Conclusions. We consider 16S rRNA V3-V4 amplicon sequencing to be a promising tool; however, further studies are needed to clarify uncertainties regarding the
Background and purpose. Previous publications have reported an increased but levelling out risk of revision for infection after total hip arthroplasty (THA) in Norway. We assessed the changes in risk of major (cup and/or stem, 1- or 2-stage) and minor revisions (debridement, exchange of modular parts, antibiotics and implant retention (DAIR)) for infection after primary THAs reported to the Norwegian Arthroplasty Register (NAR) over the period 2005-2022. Patients and methods. Primary THAs reported to the NAR from 2005 to 2022 were included. Time was stratified into time periods (2005-2009, 2010-2018, 2019-2022) based on a previous publication. Cox regression analyses, adjusted for sex, age and ASA-classification, with the first revision for infection were performed. Results. 140,338 primary THAs met the inclusion criteria. 1.3% (1,785) were revised for infection during the study period. 0.5% (638) had major revisions, whereas 0.8% (1,147) had DAIRs for infection. The risk of revision for infection was 1.2 (95%CI 1.1-1.4) for 2010-2018 and 1.0 (0.8-1.1) for 2019-2022 compared to 2005-2009. Compared to 2010-2018, the risk of revision for infection was 0.8 (0.7-0.9) for 2019-2022. The risk of DAIR for infection was 1.5 (1.3-1.9) for 2010-2018 and 1.2 (1.0-1.4) for 2019-2022 compared to 2005-2009. Compared to 2010-2018, the risk of DAIR for infection was 0.8 (0.7-0.9) for 2019-2022. The risk of major revision for infection was 0.8 (0.7-1.0) for 2010-2018 and 0.8 (0.6-1.0) for 2019-2022 compared to 2005-2009.
The objective of this study was to compare simulated range of motion (ROM) for reverse total shoulder arthroplasty (rTSA) with and without adjustment for scapulothoracic orientation in a global reference system. We hypothesized that values for simulated ROM in preoperative planning software with and without adjustment for scapulothoracic orientation would be significantly different. A statistical shape model of the entire humerus and scapula was fitted into ten shoulder CT scans randomly selected from 162 patients who underwent rTSA. Six shoulder surgeons independently planned a rTSA in each model using prototype development software with the ability to adjust for scapulothoracic orientation, the starting position of the humerus, as well as kinematic planes in a global reference system simulating previously described posture types A, B, and C. ROM with and without posture adjustment was calculated and compared in all movement planes.Aims
Methods
The purpose of this study was to develop a convolutional neural network (CNN) for fracture detection, classification, and identification of greater tuberosity displacement ≥ 1 cm, neck-shaft angle (NSA) ≤ 100°, shaft translation, and articular fracture involvement, on plain radiographs. The CNN was trained and tested on radiographs sourced from 11 hospitals in Australia and externally validated on radiographs from the Netherlands. Each radiograph was paired with corresponding CT scans to serve as the reference standard based on dual independent evaluation by trained researchers and attending orthopaedic surgeons. Presence of a fracture, classification (non- to minimally displaced; two-part, multipart, and glenohumeral dislocation), and four characteristics were determined on 2D and 3D CT scans and subsequently allocated to each series of radiographs. Fracture characteristics included greater tuberosity displacement ≥ 1 cm, NSA ≤ 100°, shaft translation (0% to < 75%, 75% to 95%, > 95%), and the extent of articular involvement (0% to < 15%, 15% to 35%, or > 35%).Aims
Methods
We aimed to compare reoperations following distal radial fractures (DRFs) managed with early fixation versus delayed fixation following initial closed reduction (CR). We used administrative databases in Ontario, Canada, to identify DRF patients aged 18 years or older from 2003 to 2016. We used procedural and fee codes within 30 days to determine which patients underwent early fixation (≤ seven days) or delayed fixation following CR. We grouped patients in the delayed group by their time to definitive fixation (eight to 14 days, 15 to 21 days, and 22 to 30 days). We used intervention and diagnostic codes to identify reoperations within two years. We used multivariable regression to compare the association between early versus delayed fixation and reoperation for all patients and stratified by age (18 to 60 years and > 60 years).Aims
Methods
Treatment of high-grade limb bone sarcoma that invades a joint requires en bloc extra-articular excision. MRI can demonstrate joint invasion but is frequently inconclusive, and its predictive value is unknown. We evaluated the diagnostic accuracy of direct and indirect radiological signs of intra-articular tumour extension and the performance characteristics of MRI findings of intra-articular tumour extension. We performed a retrospective case-control study of patients who underwent extra-articular excision for sarcoma of the knee, hip, or shoulder from 1 June 2000 to 1 November 2020. Radiologists blinded to the pathology results evaluated preoperative MRI for three direct signs of joint invasion (capsular disruption, cortical breach, cartilage invasion) and indirect signs (e.g. joint effusion, synovial thickening). The discriminatory ability of MRI to detect intra-articular tumour extension was determined by receiver operating characteristic analysis.Aims
Methods
The sensitivity and specificity of electrodiagnostic parameters in diagnosing carpal tunnel syndrome (CTS) have been reported differently, and this study aims to address this gap. This case-control study was conducted on 57 cases with CTS and 58 controls without complaints, such as pain or paresthesia on the median nerve. The main assessed electrodiagnostic parameters were terminal latency index (TLI), residual latency (RL), median ulnar F-wave latency difference (FdifMU), and median sensory latency-ulnar motor latency difference (MSUMLD).Aims
Methods
This study aims to evaluate the impact of metabolic syndrome in the setting of obesity on in-hospital outcomes and resource use after total joint replacement (TJR). A retrospective analysis was conducted using the National Inpatient Sample from 2006 to the third quarter of 2015. Discharges representing patients aged 40 years and older with obesity (BMI > 30 kg/m2) who underwent primary TJR were included. Patients were stratified into two groups with and without metabolic syndrome. The inverse probability of treatment weighting (IPTW) method was used to balance covariates.Aims
Methods
Limited implant survival due to aseptic cup loosening is most commonly responsible for revision total hip arthroplasty (THA). Advances in implant designs and materials have been crucial in addressing those challenges. Vitamin E-infused highly cross-linked polyethylene (VEPE) promises strong wear resistance, high oxidative stability, and superior mechanical strength. Although VEPE monoblock cups have shown good mid-term performance and excellent wear patterns, long-term results remain unclear. This study evaluated migration and wear patterns and clinical and radiological outcomes at a minimum of ten years’ follow-up. This prospective observational study investigated 101 cases of primary THA over a mean duration of 129 months (120 to 149). At last follow-up, 57 cases with complete clinical and radiological outcomes were evaluated. In all cases, the acetabular component comprised an uncemented titanium particle-coated VEPE monoblock cup. Patients were assessed clinically and radiologically using the Harris Hip Score, visual analogue scale (pain and satisfaction), and an anteroposterior radiograph. Cup migration and polyethylene wear were measured using Einzel-Bild-Röntgen-Analyze software. All complications and associated treatments were documented until final follow-up.Aims
Methods
Periprosthetic joint infection (PJI) is a challenging complication of any arthroplasty procedure. We reviewed our use of static antibiotic-loaded cement spacers (ABLCSs) for staged management of PJI where segmental bone loss, ligamentous instability, or soft-tissue defects necessitate a static construct. We reviewed factors contributing to their failure and techniques to avoid these complications when using ABLCSs in this context. A retrospective analysis was conducted of 94 patients undergoing first-stage revision of an infected knee prosthesis between September 2007 and January 2020 at a single institution. Radiographs and clinical records were used to assess and classify the incidence and causes of static spacer failure. Of the 94 cases, there were 19 primary total knee arthroplasties (TKAs), ten revision TKAs (varus-valgus constraint), 20 hinged TKAs, one arthrodesis (nail), one failed spacer (performed elsewhere), 21 distal femoral endoprosthetic arthroplasties, and 22 proximal tibial arthroplasties.Aims
Methods
The aim of this study was to gain a consensus for best practice of the assessment and management of children with idiopathic toe walking (ITW) in order to provide a benchmark for practitioners and guide the best consistent care. An established Delphi approach with predetermined steps and degree of agreement based on a standardized protocol was used to determine consensus. The steering group members and Delphi survey participants included members from the British Society of Children’s Orthopaedic Surgery (BSCOS) and the Association of Paediatric Chartered Physiotherapists (APCP). The statements included definition, assessment, treatment indications, nonoperative and operative interventions, and outcomes. Descriptive statistics were used for analysis of the Delphi survey results. The AGREE checklist was followed for reporting the results.Aims
Methods
The October 2024 Oncology Roundup360 looks at: Composite reconstruction: is it the answer for pelvic resections?; Can the cartilaginous thickness determine the risk of malignancy in pelvic cartilaginous tumours, and how accurate is the preoperative biopsy of these tumours?; Incidence and survival outcomes of patients with high-grade appendicular bone sarcoma and isolated regional lymph node metastasis; Improved metastatic-free survival after systematic re-excision following complete macroscopic unplanned excision of limb or trunk soft-tissue sarcoma; UK guidelines for the management of soft-tissue sarcomas; Current management of desmoid tumours: a review.
This study aimed to gather insights from elbow experts using the Delphi method to evaluate the influence of patient characteristics and fracture morphology on the choice between operative and nonoperative treatment for coronoid fractures. A three-round electronic (e-)modified Delphi survey study was performed between March and December 2023. A total of 55 elbow surgeons from Asia, Australia, Europe, and North America participated, with 48 completing all questionnaires (87%). The panellists evaluated the factors identified as important in literature for treatment decision-making, using a Likert scale ranging from "strongly influences me to recommend nonoperative treatment" (1) to "strongly influences me to recommend operative treatment" (5). Factors achieving Likert scores ≤ 2.0 or ≥ 4.0 were deemed influential for treatment recommendation. Stable consensus is defined as an agreement of ≥ 80% in the second and third rounds.Aims
Methods
The aims of this study were to validate the minimal clinically important difference (MCID) and patient-acceptable symptom state (PASS) thresholds for Western Ontario Shoulder Instability Index (WOSI), Rowe score, American Shoulder and Elbow Surgeons (ASES), and visual analogue scale (VAS) scores following arthroscopic Bankart repair, and to identify preoperative threshold values of these scores that could predict the achievement of MCID and PASS. A retrospective review was conducted on 131 consecutive patients with anterior shoulder instability who underwent arthroscopic Bankart repair between January 2020 and January 2023. Inclusion criteria required at least one episode of shoulder instability and a minimum follow-up period of 12 months. Preoperative and one-year postoperative scores were assessed. MCID and PASS were estimated using distribution-based and anchor-based methods, respectively. Receiver operating characteristic curve analysis determined preoperative patient-reported outcome measure thresholds predictive of achieving MCID and PASS.Aims
Methods
This study aimed to quantify the shoulder kinematics during an apprehension-relocation test in patients with anterior shoulder instability (ASI) and glenoid bone loss using the radiostereometric analysis (RSA) method. Kinematics were compared with the patient’s contralateral healthy shoulder. A total of 20 patients with ASI and > 10% glenoid bone loss and a healthy contralateral shoulder were included. RSA imaging of the patient’s shoulders was performed during a repeated apprehension-relocation test. Bone volume models were generated from CT scans, marked with anatomical coordinate systems, and aligned with the digitally reconstructed bone projections on the RSA images. The glenohumeral joint (GHJ) kinematics were evaluated in the anteroposterior and superoinferior direction of: the humeral head centre location relative to the glenoid centre; and the humeral head contact point location on the glenoid.Aims
Methods
This study aimed to analyze kinematics and kinetics of the tibiofemoral joint in healthy subjects with valgus, neutral, and varus limb alignment throughout multiple gait activities using dynamic videofluoroscopy. Five subjects with valgus, 12 with neutral, and ten with varus limb alignment were assessed during multiple complete cycles of level walking, downhill walking, and stair descent using a combination of dynamic videofluoroscopy, ground reaction force plates, and optical motion capture. Following 2D/3D registration, tibiofemoral kinematics and kinetics were compared between the three limb alignment groups.Aims
Methods
Rotator cuff tear (RCT) is the leading cause of shoulder pain, primarily associated with age-related tendon degeneration. This study aimed to elucidate the potential differential gene expressions in tendons across different age groups, and to investigate their roles in tendon degeneration. Linear regression and differential expression (DE) analyses were performed on two transcriptome profiling datasets of torn supraspinatus tendons to identify age-related genes. Subsequent functional analyses were conducted on these candidate genes to explore their potential roles in tendon ageing. Additionally, a secondary DE analysis was performed on candidate genes by comparing their expressions between lesioned and normal tendons to explore their correlations with RCTs.Aims
Methods
The paediatric trigger thumb is a distinct clinical entity with unique anatomical abnormalities. The aim of this study was to present the long-term outcomes of A1 pulley release in idiopathic paediatric trigger thumbs based on established patient-reported outcome measures. This study was a cross-sectional, questionnaire-based study conducted at a tertiary care orthopaedic centre. All cases of idiopathic paediatric trigger thumbs which underwent A1 pulley release between 2004 and 2011 and had a minimum follow-up period of ten years were included in the study. The abbreviated version of the Disabilities of Arm, Shoulder and Hand questionnaire (QuickDASH) was administered as an online survey, and ipsi- and contralateral thumb motion was assessed.Aims
Methods