Advertisement for orthosearch.org.uk
Results 1 - 20 of 1320
Results per page:
Bone & Joint 360
Vol. 13, Issue 5 | Pages 39 - 42
1 Oct 2024

The October 2024 Trauma Roundup. 360. looks at: Early versus delayed weightbearing following operatively treated ankle fracture (WAX): a non-inferiority, multicentre, randomized controlled trial; The effect of early weightbearing and later weightbearing rehabilitation interventions on outcomes after ankle fracture surgery; Is intramedullary nailing of femoral diaphyseal fractures in the lateral decubitus position as safe and effective as on a traction table?; Periprosthetic fractures of the hip: Back to the Future, Groundhog Day, and horses for courses; Two big bones, one big decision: when to fix bilateral femur fractures; Comparison of ankle fracture fixation using intramedullary fibular nailing versus plate fixation; Unclassified acetabular fractures: do they really exist?


Bone & Joint 360
Vol. 13, Issue 5 | Pages 47 - 49
1 Oct 2024

The October 2024 Research Roundup360 looks at: Fracture risk among stroke survivors according to post-stroke disability status and stroke type; Noise-induced hearing loss: should surgeons be wearing ear protection during primary total joint replacement?; Intravenous dexamethasone in hip arthroscopy can enhance recovery; Patient-reported outcomes following periprosthetic joint infection of the hip and knee: a longitudinal, prospective observational study; When should surgery take place after weight loss?; Which type of surgery is the hardest physically and mentally?


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 916 - 923
1 Sep 2024
Fricka KB Wilson EJ Strait AV Ho H Hopper, Jr RH Hamilton WG Sershon RA

Aims

The optimal bearing surface design for medial unicompartmental knee arthroplasty (UKA) remains controversial. The aim of this study was to compare outcomes of fixed-bearing (FB) and mobile-bearing (MB) UKAs from a single high-volume institution.

Methods

Prospectively collected data were reviewed for all primary cemented medial UKAs performed by seven surgeons from January 2006 to December 2022. A total of 2,999 UKAs were identified, including 2,315 FB and 684 MB cases. The primary outcome measure was implant survival. Secondary outcomes included 90-day and cumulative complications, reoperations, component revisions, conversion arthroplasties, range of motion, and patient-reported outcome measures. Overall mean age at surgery was 65.7 years (32.9 to 94.3), 53.1% (1,593/2,999) of UKAs were implanted in female patients, and demographics between groups were similar (p > 0.05). The mean follow-up for all UKAs was 3.7 years (0.0 to 15.6).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 48 - 48
19 Aug 2024
Falez F Casella F Zaccagno S
Full Access

Post-operative peri-prosthetic femoral fracture (PO-PPFF) is one of the most relevant complications in primary Total Hip Arthroplasty (pTHA), accountable for a significant clinical and socio-economic burden both in revision and fixation settings. We retrospectively reviewed of our series of 1586 cementless total hip arthroplasty performed between 1999 and 2019 (achieving a minimum of 5-years follow-up) with different short stems. We have observed a cumulative low incidence of PO-PPFF of 0,33% (5 cases): we divided Po-PPFF in two groups: fracture occurred around a short stem (A) and around a standard shortened stem (B), according to French Hip & Knee Classification of Short Stems. Despite the length of observed period (mean follow-up 12 years, min 5 years max 24 years) a total of 1512 cases (mean age at surgery 61 years, max 74, min 40 years) were available to clinical and radiographic follow-up, being this population enrolled in elective surgery clinical protocols. Our data exceed the low incidence of post-operative femoral fracture around bone -preserving previously reported by Kim in 2018 (12 fracture out of 1089 cases:1.1%). No correlation have been observed among occurrence of PO-PPF age of the patient and no fracture occurred around cemented short stems despite patient's characteristics were unfavourable in term of age and bone quality. This result is not unexpected, giving the lower incidence of peri-prosthetic fracture even cemented conventional stems, as reported in all registry and systematic reviews. A similar behaviour was reported in 2020 Australian Joint Registry, where Post-operative periprosthetic femoral fracture showed a steep curve in early period, but remaining firmly below 1% during the following 12 years. Our clinical data seems to confirm previous studies by Jones (conducted on synthetic bone and fresh-frozen cadaveric femurs) where higher fracture angles and higher fracture torque were detected in short hips compared to standard stems


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 47 - 47
19 Aug 2024
Dimitriou D Almazrua I Alhasson M Staunton P Zukor D Huk O Antoniou J
Full Access

Short stems have been developed to conserve bone stock, especially in younger populations undergoing a total hip arthroplasty (THA), and showed similar functional outcomes compared to conventional stems. Recent literature suggested that stem length might be an independent risk factor for acute periprosthetic femoral fracture in direct anterior THA (1) or with different short stem designs (2). The purpose of the present study was to compare the incidence of acute periprosthetic femoral fractures, between stems of the same manufacture (Taperloc microplasty vs Taperloc complete), which have the same stem characteristics, except for the stem length which is 35 mm shorter in Taperloc microplasty during posterior and lateral THA.

Our institution's arthroplasty database was searched for all primary total hip arthroplasties utilizing short femoral stems performed between August 2016 and August 2023. Pre-operative X-rays for each case were analysed to characterize the proximal femoral geometry, specifically the canal bone ratio (CBR) and canal flare index (CFI). Data analysis was performed to identify risk factors for periprosthetic fractures.

For the time period assessed, 2107 femoral stems (Taperloc Microplasty:1727, Taperloc complete: 380) were implanted. Females constituted 53% of the cohort. The average patient age was 70±11 years. The periprosthetic fracture rate was 0.94%, with 20 periprosthetic fractures (Taperloc Microplasty:17, Taperloc complete: 3) excluding 2 greater trochanteric fractures (1 at each group), identified at follow-up of three months. There was no significant difference between the periprosthetic fracture rates between the two stems (0.98% vs 0.79%, p>0.72) The multivariate regression analysis demonstrated that the stem length, CBR, CFI, age, and gender were not risk factors for periprosthetic fracture.

The present study demonstrated that both Taperloc Microplasty and Taperloc complete stems had similar rates of periprosthetic fractures, and the stem length was not a risk factor for a periprosthetic fracture during uncemented THA.

1. Tamaki T, Cementless Tapered-Wedge Stem Length Affects the Risk of Periprosthetic Femoral Fractures in Direct Anterior Total Hip Arthroplasty. J Arthroplasty. 2018 Mar;33(3):805-809. 2. Staunton P. Acute Periprosthetic Hip Fracture with Short Uncemented Femoral Stems. J Arthroplasty 2024 accepted.


Bone & Joint 360
Vol. 13, Issue 4 | Pages 31 - 35
2 Aug 2024

The August 2024 Trauma Roundup. 360. looks at: Does topical vancomycin prevent fracture-related infections in closed fractures undergoing open reduction and internal fixation? A randomized controlled trial; Is postoperative splinting advantageous after upper limb fracture surgery?; Does suprapatellar nailing resolve knee pain?; Locking versus non-locking plate fixation in comminuted talar neck fractures: a biomechanical study using cadaveric specimens; Revolutionizing recovery metrics: PROMIS versus SMFA in orthopaedic trauma care; Dorsal hook plating of patella fractures: reliable fixation and satisfactory outcomes; The impact of obesity on subtrochanteric femur fracture outcomes; Low-dose NSAIDs (ketorolac) and cytokine modulation in orthopaedic polytrauma: a detailed analysis


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_14 | Pages 11 - 11
23 Jul 2024
Sarhan M Moreau J Francis S Page P
Full Access

Hip fractures frequently occur in elderly patients with osteoporosis and are rapidly increasing in prevalence owing to an increase in the elderly population and social activities. We experienced several recent presentations of TFNA nails failed through proximal locking aperture which requires significant revision surgery in often highly co-morbid patient population.

The study was done by retrospective data collection from 2013 to 2023 of all the hip fractures which had been fixed with Cephalomedullary nails to review and compare Gamma (2013–2017) and TFNA (2017–2023) failure rates and the timing of the failures. Infected and Elective revision to Arthroplasty cases were excluded.

The results are 1034 cases had been included, 784 fixed with TFNA and 250 cases fixed Gamma nails. Out of the 784 patients fixed with TFNA, 19 fixation failed (2.45%). Out of the 250 cases fixed with Gamma nails, 15 fixation failed (6%). Mean days for fixation failure were 323 and 244 days in TFNA and Gamma nails respectively.

We conclude that TFNA showed remarkable less failure rates if compared to Gamma nails. At point of launch, testing was limited and no proof of superiority of TFNA over Gamma nail. Several failures identified with proximal locking aperture in TFNA which can be related to the new design which had Substantial reduction in lateral thickness at compression screw aperture.


Femoral shaft fractures are fairly common injuries in paediatric age group. The treatment protocols are clear in patients of age less than 4 years and greater than 6 years. The real dilemma lies in the age group of 4–6 years. The aim of this study is to find whether a conservative line should be followed, or a more aggressive surgical intervention can provide significantly better results in these injuries. This study was conducted in a tertiary care hospital in Bhubaneswar, India from January 2020 to March 2021. A total of 40 patients with femur shaft fractures were included and randomly divided in two treatment groups. Group A were treated with a TENS nail while group B were treated with skin traction followed by spica cast. They were regularly followed up with clinical and radiological examination to look out for signs of healing and any complications. TENS was removed at 4–9 months’ time in all Group A patients. Group A patients had a statistically significant less hospital stay, immobilisation period, time to full weight bearing and radiological union. Rotational malunions were significantly lower in Group A (p-value 0.0379) while there was no statistically significant difference in angular malunion in coronal and sagittal plane at final follow up. Complications unique to group A were skin necrosis and infection. We conclude that TENS is better modality for treatment of shaft of femur fractures in patients of 4–6 years age as they significantly reduce the hospital stay, immobilization period and rotational malalignment


Bone & Joint Open
Vol. 5, Issue 6 | Pages 489 - 498
12 Jun 2024
Kriechling P Bowley ALW Ross LA Moran M Scott CEH

Aims

The purpose of this study was to compare reoperation and revision rates of double plating (DP), single plating using a lateral locking plate (SP), or distal femoral arthroplasty (DFA) for the treatment of periprosthetic distal femur fractures (PDFFs).

Methods

All patients with PDFF primarily treated with DP, SP, or DFA between 2008 and 2022 at a university teaching hospital were included in this retrospective cohort study. The primary outcome was revision surgery for failure following DP, SP, or DFA. Secondary outcome measures included any reoperation, length of hospital stay, and mortality. All basic demographic and relevant implant and injury details were collected. Radiological analysis included fracture classification and evaluation of metaphyseal and medial comminution.


Bone & Joint 360
Vol. 13, Issue 3 | Pages 18 - 20
3 Jun 2024

The June 2024 Hip & Pelvis Roundup. 360. looks at: Machine learning did not outperform conventional competing risk modelling to predict revision arthroplasty; Unravelling the risks: incidence and reoperation rates for femoral fractures post-total hip arthroplasty; Spinal versus general anaesthesia for hip arthroscopy: a COVID-19 pandemic- and opioid epidemic-driven study; Development and validation of a deep-learning model to predict total hip arthroplasty on radiographs; Ambulatory centres lead in same-day hip and knee arthroplasty success; Exploring the impact of smokeless tobacco on total hip arthroplasty outcomes: a deeper dive into postoperative complications


Bone & Joint Open
Vol. 5, Issue 6 | Pages 457 - 463
2 Jun 2024
Coviello M Abate A Maccagnano G Ippolito F Nappi V Abbaticchio AM Caiaffa E Caiaffa V

Aims. Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail. Methods. A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value. Results. A total of 98 of the 112 patients met the inclusion criteria. Overall, 65 patients were female (66.3%), the mean age was 83.23 years (SD 7.07), and the mean follow-up was 378 days (SD 36). Cut-out was observed in five patients (5.10%). The variables identified by univariate analysis with p < 0.05 were included in the multivariate logistic regression model were screw placement and TAD. The TAD was significant with an odds ratio (OR) 5.03 (p = 0.012) as the screw placement with an OR 4.35 (p = 0.043) in the anteroposterior view, and OR 10.61 (p = 0.037) in the lateral view. The TAD threshold value identified was 29.50 mm. Conclusion. Our study confirmed the risk factors for cut-out in the double-screw nail are comparable to those in the single screw. We found a TAD value of 29.50 mm to be associated with a risk of cut-out in double-screw nails, when good fracture reduction is granted. This value is higher than the one reported with single-screw nails. Therefore, we suggest the role of TAD should be reconsidered in well-reduced fractures treated with double-screw intramedullary nail. Cite this article: Bone Jt Open 2024;5(6):457–463


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 26 - 26
10 May 2024
Mauiliu S
Full Access

Titanium Elastic Nails have been around for the last 40 years, but it has never been introduced properly in the Pacific especially in Samoa in the management of femoral & in severely displaced forearm fractures in the paediatric age group & also Adult upper limb Trauma. This paper looks at the cases treated in TTM Hospital (Apia, Samoa) from June 2019- June 2023, looking at common injury patterns, indications for fixation and the cost benefit to the family and hospital, in terms of early rehabilitation and improving the length of stay in hospital pre-Tens nail era from 6–8 weeks to 1–2 weeks in hospital. 29 cases were treated with TENs concept during this period, 17 femoral fractures, 10 forearm fractures & 1 humerus fracture. Lastly this is very useful skill and tool to have in every hospital in the Pacific Islands, through proper training to prevent long term complications


Bone & Joint Research
Vol. 13, Issue 5 | Pages 214 - 225
3 May 2024
Groven RVM Kuik C Greven J Mert Ü Bouwman FG Poeze M Blokhuis TJ Huber-Lang M Hildebrand F Cillero-Pastor B van Griensven M

Aims

The aim of this study was to determine the fracture haematoma (fxH) proteome after multiple trauma using label-free proteomics, comparing two different fracture treatment strategies.

Methods

A porcine multiple trauma model was used in which two fracture treatment strategies were compared: early total care (ETC) and damage control orthopaedics (DCO). fxH was harvested and analyzed using liquid chromatography-tandem mass spectrometry. Per group, discriminating proteins were identified and protein interaction analyses were performed to further elucidate key biomolecular pathways in the early fracture healing phase.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 55 - 55
2 May 2024
McCann C Ablett A Feng T Macaskill V Oliver W Keating J
Full Access

Subtrochanteric femoral fractures are a subset of hip fractures generally treated with cephalomedullary nail fixation\[1\]. Single lag screw devices are most commonly-used, but integrated dual screw constructs have become increasingly popular\[2,3\]. The aim of this study was to compare outcomes of fixation of subtrochanteric femoral fractures using a single lag screw (Gamma3 nail, GN) with a dual screw device (InterTAN nail, IN). The primary outcome was mechanical failure, defined as lag screw cut-out, back-out, nail breakage or peri-implant fracture. Consecutive adult patients (18yrs) with subtrochanteric femoral fracture treated in a single centre were retrospectively identified using electronic records. Patients that underwent surgical fixation using either a long GN (2010–2017) or IN (2017–2022) were included. Medical records and radiographs were reviewed to identify complications of fixation. Cox regression analysis was used to determine the risk of mechanical failure and secondary outcomes by implant design. Multivariable regression models were used to identify predictors of mechanical failure. The study included 622 patients, 354 in the GN group (median age 82yrs, 72% female) and 268 in the IN group (median age 82yrs, 69% female). The risk of any mechanical failure was increased two-fold in the GN group (HR 2.44 \[95%CI 1.13 to 5.26\]; _p=0.024_). Mechanical failure comprising screw cut-out (_p=0.032_), back-out (_p=0.032_) and nail breakage (_p=0.26_) was only observed in the GN group. Technical predictors of failure included varus >5° for cut-out (OR 19.98 \[2.06 to 193.88\]; _p=0.01_), TAD;25mm for back-out (8.96 \[1.36 to 58.86\]; p=0.022) and shortening 1cm for peri-implant fracture (7.81 \[2.92 to 20.91\]; _p=<0.001_). Our results demonstrate that an intercalated screw construct is associated with a lower risk of mechanical failure compared with the a single lag screw device. Intercalated screw designs may reduce the risk of mechanical complications for patients with subtrochanteric femoral fractures


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 32 - 32
2 May 2024
Yan A Yan A Hoggett L Helm A
Full Access

The increased torque required to dislocate dual mobility (DM) components may increase peri-prosthetic femoral fracture (PPF) risk. Current literature often relies on revision as an endpoint and may underestimate PPF. This study aims to review PPF rate, risks and treatment following primary DM implantation. Prospective cohort study of 549 patients following primary DM total hip arthroplasty (THA) between 2013 and 2021. Collected data included demographics, indication for surgery, cortical index and PPF. 549 patients were identified with primary DM THA. Mean age was 73 years (26–96). 446 (81.2%) patients had their index surgery following hip fracture. 18 patients (3.27%) sustained a PPF. Cumulative PPF rate was 1.5% at 1-year, 2.2% at 5-years and 3.27% overall. PPF was higher in patients undergoing surgery following hip fracture (4%) vs. other indications (1%). OR 4.04 (95% CI:0.53, 30.72), p=0.219. Mean cortical index was lower in patients with PPF 0.4 (95% CI:0.36, 0.45) compared to those without 0.46 (95% CI:0.45, 0.46) p=0.029. Treatment for PPF included 10 (55.6%) open reduction internal fixation (ORIF), 7 (38.9%) revision THA and 1 conservatively managed. PPF rate following DM use is higher in our cohort than published rates. Our rates are comparable to some papers when subgroup analysis of older patients and cemented taper slip stems are considered. PPF risk with DM may be increased in patients undergoing surgery after hip fracture or with a lower cortical index preoperatively. Over half of PPF were managed with ORIF and may mask PPF risk studies that report using revision as an endpoint


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 35 - 35
2 May 2024
Robinson M Wong ML Cassidy R Bryce L Lamb J Diamond O Beverland D
Full Access

The significance of periprosthetic fractures about a total hip arthroplasty (THA) is becoming increasingly important. Recent studies have demonstrated post-operative periprosthetic fracture rates are higher amongst cemented polished taper slip (PTS) stem designs compared to collared cementless (CC) designs.

However, in the National Joint Registry, the rate of intra-operative periprosthetic femoral fractures (IOPFF) with cementless implant systems remains higher (0.87% vs 0.42%. p <0.001) potentially leading to more post-operative complications.

This study identifies the incidence of IOPFF, the fracture subtype and compares functional outcomes and revision rates of CC femoral implants with an IOPFF to CC stems and PTS stems without a fracture.

5376 consecutive CC stem THA, carried out through a posterior approach were reviewed for IOPFF. Each fracture was subdivided into calcar fracture, greater trochanter (GT) fracture or shaft fracture.

1:1:1 matched analysis was carried out to compare Oxford scores at one year. Matching criteria included; sex (exact), age (± 1 year), American Society of Anaesthesiologists (ASA) grade (exact), and date of surgery (± 6 months).

Electronic records were used to review revision rates.

Following review of the CC stems, 44 (0.8%) were identified as having an IOPFF. Of these 30 (0.6%) were calcar fractures, 11 (0.2%) GT fractures and 3 (0.06%) were shaft fractures. There were no shaft penetrations.

Overall, no significant difference in Oxford scores at one year were observed when comparing the CC IOPFF, CC non-IOPFF and PTS groups.

There were no CC stems revised for any reason with either a calcar fracture or trochanteric fracture within the period of 8 years follow-up.

IOPFF do occur more frequently in cementless systems than cemented. The majority are calcar and GT fractures. These fractures, when identified and managed intra-operatively, do not have worse functional outcomes or revision rates compared to matched non-IOPFF cases.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 125 - 132
1 May 2024
Carender CN Perry KI Sierra RJ Trousdale RT Berry DJ Abdel MP

Aims

Uncemented implants are now commonly used at reimplantation of a two-stage revision total hip arthoplasty (THA) following periprosthetic joint infection (PJI). However, there is a paucity of data on the performance of the most commonly used uncemented femoral implants – modular fluted tapered (MFT) femoral components – in this setting. This study evaluated implant survival, radiological results, and clinical outcomes in a large cohort of reimplantation THAs using MFT components.

Methods

We identified 236 reimplantation THAs from a single tertiary care academic institution from September 2000 to September 2020. Two designs of MFT femoral components were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years (SD 11), mean BMI was 32 kg/m2 (SD 7), and 46% (n = 109) were female. Mean follow-up was seven years (SD 4). A competing risk model accounting for death was used.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 133 - 138
1 May 2024
Peuchot H Jacquet C Fabre-Aubrespy M Ferguson D Ollivier M Flecher X Argenson J

Aims

Dual-mobility acetabular components (DMCs) have improved total hip arthroplasty (THA) stability in femoral neck fractures (FNFs). In osteoarthritis, the direct anterior approach (DAA) has been promoted for improving early functional results compared with the posterolateral approach (PLA). The aim of this study was to compare these two approaches in FNF using DMC-THA.

Methods

A prospective continuous cohort study was conducted on patients undergoing operation for FNF using DMC by DAA or PLA. Functional outcome was evaluated using the Harris Hip Score (HHS) and Parker score at three months and one year. Perioperative complications were recorded, and radiological component positioning evaluated.


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 442 - 449
1 May 2024
Nieboer MF van der Jagt OP de Munter L de Jongh MAC van de Ree CLP

Aims. Periprosthetic proximal femoral fractures (PFFs) are a major complication after total hip arthroplasty (THA). Health status after PFF is not specifically investigated. The aim of this study is to evaluate the health status pattern over two years after sustaining a PFF. Methods. A cohort of patients with PFF after THA was derived from the Brabant Injury Outcomes Surveillance (BIOS) study. The BIOS study, a prospective, observational, multicentre follow-up cohort study, was conducted to obtain data by questionnaires pre-injury and at one week, and one, three, six, 12, and 24 months after trauma. Primary outcome measures were the EuroQol five-dimension three-level questionnaire (EQ-5D-3L), the Health Utility Index 2 (HUI2), and the Health Utility Index 3 (HUI3). Secondary outcome measures were general measurements such as duration of hospital stay and mortality. Results. A total of 70 patients with a PFF were included. EQ-5D utility scores were significantly lower on all timepoints except at six months’ follow-up compared to pre-injury. EuroQol visual analogue scale (EQ-VAS) scores at one month's follow-up were significantly lower compared to pre-injury. The percentage of reported problems at two years was higher for all dimensions except anxiety/depression when compared to pre-injury. The mean EQ-5D utility score was 0.26 higher in males compared to females (95% confidence interval (CI) 0.01 to 0.42; p = 0.003). The mean EQ-VAS score for males was 8.9 points higher when compared to females over all timepoints (95% CI 1.2 to 16.7; p = 0.027). Mortality was 10% after two years’ follow-up. Conclusion. PFF patients are a frail population with substantial functional impairment at baseline. Post-injury, they have a significant and clinically relevant lower health status two years after trauma when compared to pre-injury. Health status improves the most between one and three months after injury. Two years after PFF, more patients experience problems in mobility, self-care, usual activities, and pain/discomfort than pre-injury. Cite this article: Bone Joint J 2024;106-B(5):442–449


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 430 - 434
1 May 2024
Eardley WGP