Advertisement for orthosearch.org.uk
Results 1 - 20 of 29
Results per page:
Bone & Joint Open
Vol. 5, Issue 10 | Pages 937 - 943
22 Oct 2024
Gregor RH Hooper GJ Frampton C

Aims

The aim of this study was to determine whether obesity had a detrimental effect on the long-term performance and survival of medial unicompartmental knee arthroplasties (UKAs).

Methods

This study reviewed prospectively collected functional outcome scores and revision rates of all medial UKA patients with recorded BMI performed in Christchurch, New Zealand, from January 2011 to September 2021. Patient-reported outcome measures (PROMs) were the primary outcome of this study, with all-cause revision rate analyzed as a secondary outcome. PROMs were taken preoperatively, at six months, one year, five years, and ten years postoperatively. There were 873 patients who had functional scores recorded at five years and 164 patients had scores recorded at ten years. Further sub-group analysis was performed based on the patient’s BMI. Revision data were available through the New Zealand Joint Registry for 2,323 UKAs performed during this time period.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 401 - 411
1 Apr 2024
Carrothers A O'Leary R Hull P Chou D Alsousou J Queally J Bond SJ Costa ML

Aims

To assess the feasibility of a randomized controlled trial (RCT) that compares three treatments for acetabular fractures in older patients: surgical fixation, surgical fixation and hip arthroplasty (fix-and-replace), and non-surgical treatment.

Methods

Patients were recruited from seven UK NHS centres and randomized to a three-arm pilot trial if aged older than 60 years and had a displaced acetabular fracture. Feasibility outcomes included patients’ willingness to participate, clinicians’ capability to recruit, and dropout rates. The primary clinical outcome measure was the EuroQol five-dimension questionnaire (EQ-5D) at six months. Secondary outcomes were Oxford Hip Score, Disability Rating Index, blood loss, and radiological and mobility assessments.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 24 - 24
1 Jul 2022
Spolton-Dean C Burden E East J Toms A Bhamber N Waterson B
Full Access

Abstract. Introduction. OtisMed Shape Match ® patient specific implant cutting jigs were designed to place TKA in kinematic alignment (KA) rather than traditional mechanical alignment (MA). This product was withdrawn from the market in 2013. It has been hypothesised that KA might lead to early implant failure. Initial evidence has not supported this. We present 10 year outcome data for the largest single centre cohort to date. Methodology. Between 2010 and 2013, 127 Shape Match® TKAs were implanted in 119 individuals. Retrospective review of long leg post-operative radiographs assessed femoral mechanical anatomical angle (FMA), tibial mechanical angle (TMA), hip-knee-ankle angle (HKA), posterior tibial slope (PTS) and femoral component flexion. Oxford Knee Scores (OKS), revision and further surgery rates were reviewed. Results. 4 (3.1%) patients underwent revision for instability, recurrent haemarthrosis, stiffness and infection respectively. In this subgroup, PTS ranged from 9–25° (SD 7.5°). PTS range for non-revision subgroup was 1–23° (SD 4.6). 1 patient with a PTS of 21° had failure of quadriceps tendon, but was not revised. Mean OKS at 1year = 38.1 (SD 1.08), 2 years = 39.3 (SD 1.08), 5 years = 40.8 (SD 4.11). PTS had the largest impact on OKS, with <10° slope conferring a higher OKS. Conclusions. At 10 year follow up, this cohort did identify several cases where excessive PTS was evident. This may have led to revision surgery and contributed post-operative complications. PTS, unlike other alignment measures, impacted OKS results. Overall revision rate and OKS were consistent with registry and other published data


Bone & Joint Open
Vol. 3, Issue 6 | Pages 495 - 501
14 Jun 2022
Keohane D Sheridan GA Masterson E

Aims

Total knee arthroplasty (TKA) is a common and safe orthopaedic procedure. Zimmer Biomet's NexGen is the second most popular brand of implant used in the UK. The primary cause of revision after the first year is aseptic loosening. We present our experience of using this implant, with significant concerns around its performance with regards early aseptic loosening of the tibial component.

Methods

A retrospective, single-surgeon review was carried out of all of the NexGen Legacy Posterior Stabilized (LPS) TKAs performed in this institute. The specific model used for the index procedures was the NexGen Complete Knee System (Legacy Knee-Posterior Stabilized LPS-Flex Articular Surface, LPS-Flex Femoral Component Option, and Stemmed Nonaugmentable Tibial Component Option).


Bone & Joint 360
Vol. 10, Issue 6 | Pages 35 - 39
1 Dec 2021


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 822 - 827
1 May 2021
Buzzatti L Keelson B Vanlauwe J Buls N De Mey J Vandemeulebroucke J Cattrysse E Scheerlinck T

Evaluating musculoskeletal conditions of the lower limb and understanding the pathophysiology of complex bone kinematics is challenging. Static images do not take into account the dynamic component of relative bone motion and muscle activation. Fluoroscopy and dynamic MRI have important limitations. Dynamic CT (4D-CT) is an emerging alternative that combines high spatial and temporal resolution, with an increased availability in clinical practice. 4D-CT allows simultaneous visualization of bone morphology and joint kinematics. This unique combination makes it an ideal tool to evaluate functional disorders of the musculoskeletal system. In the lower limb, 4D-CT has been used to diagnose femoroacetabular impingement, patellofemoral, ankle and subtalar joint instability, or reduced range of motion. 4D-CT has also been used to demonstrate the effect of surgery, mainly on patellar instability. 4D-CT will need further research and validation before it can be widely used in clinical practice. We believe, however, it is here to stay, and will become a reference in the diagnosis of lower limb conditions and the evaluation of treatment options.

Cite this article: Bone Joint J 2021;103-B(5):822–827.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 294 - 298
1 Feb 2021
Hadeed MM Prakash H Yarboro SR Weiss DB

Aims. The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols. Methods. A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals. Results. The spiral and oblique fracture patterns withstood simulated weight-bearing with minimal displacement. The multifragmented model had early implant failure with breaking of the distal locking screws. The spiral fracture model shortened by a mean of 0.3 mm (SD 0.2), and developed a mean coronal angulation of 2.0° (SD 1.9°) and a mean sagittal angulation of 1.2° (SD 1.1°). On average, 88% of the shortening, 74% of the change in coronal alignment, and 75% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. The oblique fracture model shortened by a mean of 0.2 mm (SD 0.1) and developed a mean coronal angulation of 2.4° (SD 1.6°) and a mean sagittal angulation of 2.6° (SD 1.4°). On average, 44% of the shortening, 39% of the change in coronal alignment, and 79% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. Conclusion. For spiral and oblique fracture patterns, simulated weight-bearing resulted in a clinically acceptable degree of displacement. Most displacement occurred early in the test period, and the rate of displacement decreased over time. Based on this model, we offer evidence that early weight-bearing appears safe for well reduced oblique and spiral fractures, but not in multifragmented patterns that have poor bone contact. Cite this article: Bone Joint J 2021;103-B(2):294–298


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 68 - 68
1 Dec 2020
Taylan O Slane J Ghijselings I Delport HP Scheys L
Full Access

Poor soft tissue balance in total knee arthroplasty (TKA) is one of the most primary causes of dissatisfaction and reduced joint longevity, which are associated with postoperative instability and early implant failure. 1. Therefore, surgical techniques, including mechanical instruments and 3-D guided navigation systems, in TKA aim to achieve optimum soft tissue balancing in the knee to improve postoperative outcome. 2. Patella-in-Place balancing (PIPB) is a novel technique which aims to restore native collateral ligament behaviour by preserving the original state without any release. Moreover, reduction of the joint laxity compensates for the loss of the visco-elastic properties of the cartilage and meniscus. Following its clinical success, we aimed to evaluate the impact of the PIPB technique on collateral ligament strain and laxity behaviour, with the hypothesis that PIPB would restore strains in the collateral ligaments. 3. . Eight fresh-frozen cadaveric legs were obtained (KU Leuven, Belgium, H019 2015-11-04) and CT images were acquired while rigid marker frames were affixed into the femur, and tibia for testing. After carefully removing the soft tissues around the knee joint, while preserving the joint capsule, ligaments, and tendons, digital extensometers (MTS, Minnesota, USA) were attached along the length of the superficial medial collateral ligament (MCL) and lateral collateral ligament (LCL). A handheld digital dynamometer (Mark-10, Copiague, USA) was used to apply an abduction or adduction moment of 10 Nm at fixed knee flexion angles of 0°, 30°, 60° and 90°. A motion capture system (Vicon Motion Systems, UK) was used to record the trajectories of the rigid marker frames while synchronized strain data was collected for MCL/LCL. All motion protocols were applied following TKA was performed using PIPB with a cruciate retaining implant (Stryker Triathlon, MI, USA). Furthermore, tibiofemoral kinematics were calculated. 4. and combined with the strain data. Postoperative tibial varus/valgus stresses and collateral ligament strains were compared to the native condition using the Wilcoxon Signed-Rank Test (p<0.05). Postoperative tibial valgus laxity was lower than the native condition for all flexion angles. Moreover, tibial valgus of TKA was significantly different than the native condition, except for 0° (p=0.32). Although, tibial varus laxity of TKA was lower than the native at all angles, significant difference was only found at 0° (p=0.03) and 90° (p=0.02). No significant differences were observed in postoperative collateral ligament strains, as compared to the native condition, for all flexion angles, except for MCL strain at 30° (p=0.02) and 60° (p=0.01). Results from this experimental study supported our hypotheses, barring MCL strain in mid-flexion, which might be associated with the implant design. Restored collateral ligament strains with reduced joint laxity, demonstrated by the PIPB technique in TKA in vitro, could potentially restore natural joint kinematics, thereby improving patient outcomes. In conclusion, to further prove the success of PIPB, further biomechanical studies are required to evaluate the success rate of PIPB technique in different implant designs


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 442 - 448
1 Apr 2020
Kayani B Konan S Ahmed SS Chang JS Ayuob A Haddad FS

Aims

The objectives of this study were to assess the effect of anterior cruciate ligament (ACL) resection on flexion-extension gaps, mediolateral soft tissue laxity, maximum knee extension, and limb alignment during primary total knee arthroplasty (TKA).

Methods

This prospective study included 140 patients with symptomatic knee osteoarthritis undergoing primary robotic-arm assisted TKA. All operative procedures were performed by a single surgeon using a standard medial parapatellar approach. Optical motion capture technology with fixed femoral and tibial registration pins was used to assess study outcomes pre- and post-ACL resection with knee extension and 90° knee flexion. This study included 76 males (54.3%) and 64 females (45.7%) with a mean age of 64.1 years (SD 6.8) at time of surgery. Mean preoperative hip-knee-ankle deformity was 6.1° varus (SD 4.6° varus).


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 880 - 888
1 Jul 2019
Wei R Guo W Yang R Tang X Yang Y Ji T Liang H

Aims

The aim of this study was to describe the use of 3D-printed sacral endoprostheses to reconstruct the pelvic ring and re-establish spinopelvic stability after total en bloc sacrectomy (TES) and to review its outcome.

Patients and Methods

We retrospectively reviewed 32 patients who underwent TES in our hospital between January 2015 and December 2017. We divided the patients into three groups on the basis of the method of reconstruction: an endoprosthesis group (n = 10); a combined reconstruction group (n = 14), who underwent non-endoprosthetic combined reconstruction, including anterior spinal column fixation; and a spinopelvic fixation (SPF) group (n = 8), who underwent only SPF. Spinopelvic stability, implant survival (IS), intraoperative haemorrhage rate, and perioperative complication rate in the endoprosthesis group were documented and compared with those of other two groups.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 317 - 324
1 Mar 2019
Moon J Kim Y Hwang K Yang J Ryu J Kim Y

Aims

The present study investigated the five-year interval changes in pseudotumours and measured serum metal ions at long-term follow-up of a previous report of 28 mm diameter metal-on-metal (MoM) total hip arthroplasty (THA).

Patients and Methods

A total of 72 patients (mean age 46.6 years (37 to 55); 43 men, 29 women; 91 hips) who underwent cementless primary MoM THA with a 28 mm modular head were included. The mean follow-up duration was 20.3 years (18 to 24). All patients had CT scans at a mean 15.1 years (13 to 19) after the index operation and subsequent follow-up at a mean of 20.2 years (18 to 24). Pseudotumour volume, type of mass, and new-onset pseudotumours were evaluated using CT scanning. Clinical outcomes were assessed by Harris Hip Score (HHS) and the presence of groin pain. Serum metal ion (cobalt (Co) and chromium (Cr)) levels were measured at the latest follow-up.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 227 - 232
1 Feb 2019
Walker T Rutkowski L Innmann M Panzram B Herre J Gotterbarm T Aldinger PR Merle C

Aims

The treatment of patients with allergies to metal in total joint arthroplasty is an ongoing debate. Possibilities include the use of hypoallergenic prostheses, as well as the use of standard cobalt-chromium (CoCr) alloy. This non-designer study was performed to evaluate the clinical outcome and survival rates of unicondylar knee arthroplasty (UKA) using a standard CoCr alloy in patients reporting signs of a hypersensitivity to metal.

Patients and Methods

A consecutive series of patients suitable for UKA were screened for symptoms of metal hypersensitivity by use of a questionnaire. A total of 82 patients out of 1737 patients suitable for medial UKA reporting cutaneous metal hypersensitivity to cobalt, chromium, or nickel were included into this study and prospectively evaluated to determine the functional outcome, possible signs of hypersensitivity, and short-term survivorship at a minimum follow-up of 1.5 years.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 81 - 81
1 Nov 2018
Gueorguiev B
Full Access

Locking plates have led to important changes in bone fracture management, allowing flexible biological fracture fixation based on the principle of an internal fixator. The technique of locking plate fixation differs fundamentally from conventional plating and has its indications and limitations. Most of the typical locking plate failure patterns are related to basic technical errors, such as under-sizing of the implant, too short working length, and imperfect application of locking screws. After analysis of the fracture morphology and intrinsic stability following fracture reduction, a meticulous preoperative planning is mandatory under consideration of the principles of the internal fixator technique to avoid technical errors and inaccuracies leading to early implant failure


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1320 - 1329
1 Oct 2018
Metcalfe D Peterson N Wilkinson JM Perry DC

Aims

The aim of this study was to describe temporal trends and survivorship of total hip arthroplasty (THA) in very young patients, aged ≤ 20 years.

Patients and Methods

A descriptive observational study was undertaken using data from the National Joint Registry (NJR) for England, Wales, Northern Ireland and the Isle of Man between April 2003 and March 2017. All patients aged ≤ 20 years at the time of THA were included and the primary outcome was revision surgery. Descriptive statistics were used to summarize the data and Kaplan–Meier estimates calculated for the cumulative implant survival.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 36 - 36
1 Apr 2018
Falkenberg A Morlock M Huber G
Full Access

Introduction. Clinical symptoms arising from corrosion within taper junctions of modular total hip prostheses are of increasing concern [1]. In particular, bi-modular implant designs showed increased failure rates due to wear originating from the neck-stem junction [2]. In-vivo corrosion-related failure is less frequently observed for head-stem junctions [3]. It is hypothesized that fretting and crevice corrosion are associated with micromotions between the mating surfaces of a taper junction [4]. The aim of this study was to measure micromotion occurring within a head-stem junction of a conventional prosthesis and clarify by how much it is exceeded in a neck-stem junction of a bi-modular prosthesis that exhibited severe corrosion and early implant failure. Material & Methods. The micromotions within two taper articulations were investigated: a head-stem taper (Corail, DePuy Synthes, Leeds, UK, Figure 1) and a neck-stem taper of a bi-modular THA prosthesis (Rejuvenate, Stryker, Kalamazoo, MI, USA). Both tapers were assembled with 2000 N. Loading at an angle of 50° to the taper axes (identical for both) in direction of the stem axis was incrementally increased from 0 N to 1900 N (n=3). Small windows (< 2.5 mm. 2. ) were cut through the female tapers by electric discharge machining, exposing the male taper surface for direct micromotion measurements by microscopic topographic measurements (Infinite Focus Microscope, Alicona Imaging GmbH, Austria). Subsequently, feature matching of the images from the differently loaded implants was applied (Matlab 2016b, The MathWorks Inc., Natick, MA, USA) to determine the local relative motion between the mating surfaces. Results. Loading with 1900 N resulted in micromotions of 1.0 µm ± 0.1 µm at the head-stem taper (Figure 2). The stepwise loading showed the motion trajectory, suggesting toggling with the dominant displacement in axial direction and small transversal movements. Neck-stem micromotion was significantly higher (14.2 µm ± 1.7 µm, p < 0.001). The trajectory revealed a tilt of the neck in direction of the force. The male taper returned into its initial position after the load was removed, indicating a repetitive rocking motion within every load sequence. Discussion. The higher micromotion at the neck-stem taper junction is likely caused by the larger lever arm (20-fold) between load application and taper engagement. This can serve to explain the susceptibility of bi-modular prostheses to an elevated rate of problems due to fretting corrosion. Similar findings are speculated to apply for large-diameter heads, which showed high failure rates in clinical practice [5]. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 91 - 91
1 Nov 2016
Almaawi A Alsheikh K Masse V Lavigne M Vendittoli P
Full Access

Modifying Knee anatomy during mechanical Total Knee Arthroplasty (TKA) may impact ligament balance, patellar tracking and quadriceps function. Although well fixed, patients may report high levels (20%) of dissatisfaction. One theory is that putting the knee in neutral mechanical alignment may be responsible for these unsatisfactory results. Kinematic TKA has gained interest in recent years; it aims to resurface the knee joint and preservation of natural femoral flexion axis about which the tibia and patella articulate, recreating the native knee without the need for soft tissue relaease. That's being said, it remains the question of whether all patients are suitable for kinematic alignment. Some patients' anatomy may be inherently biomechanically inferior and recreating native anatomy in these patients may result in early implant failure. The senior author (PAV) has been performing Kinematic TKA since 2011, and has developed an algorithm in order to better predict which patient may benefit from this technique. Lower limb CT scans from 4884 consecutive patients scheduled for TKA arthroplasty were analysed. These exams were performed for patient-specific instrumentation production (My Knee®, Medacta, Switzerland). Multiple anatomical landmarks used to create accurate CT-based preoperative planning and determine the mechanical axis of bone for the femur and tibia and overall Hip-knee-Ankle (HKA). We wanted to test the safe range for kinematic TKA for the planned distal resection of the femur and tibia. Safe range algorithm was defined as the combination of the following criteria: – Independent tibial and femoral cuts within ± 5° of the bone neutral mechanical axis and HKA within ± 3°. The purpose of this study is to verify the applicability of the proposed safe range algorithm on a large sample of individual scheduled for TKA. The preoperative tibial mechanical angle average 2.9 degrees in varus, femoral mechanical angle averaged 2.7 degrees in valgus and overall HKA averaged of 0.1 in varus. There were 2475 (51%) knees out of 4884, with femur and tibia mechanical axis within ±5° and HKA within ±3° without need for bony corrections. After applying the algorithm, a total of 4062 cases (83%) were successfully been evaluated using the proposed protocol to reach a safe range of HKA ±3° with minimal correction. The remaining 822 cases (17%) could not be managed by the proposed algorithm because of their unusual anatomies and were dealt with individually. In this study, we tested a proposed algorithm to perform kinematic alignment TKA avoiding preservation/restoration of some extreme anatomies that might not be suitable for TKA long-term survivorship. A total of 4062 cases (83%) were successfully eligible for our proposed safe range algorithm for kinematic TKA. In conclusion, kinematically aligned TKA may be a promising option to improve normal knee function restoration and patient satisfaction. Until we have valuable data confirming the compatibility of all patients' pre arthritic anatomies with TKA long-term survivorship, we believe that kinematically alignment should be performed within some limits. Further studies with Radiostereometry or longer follow up might help determine if all patients' anatomies are suitable for Kinematic TKA


Bone & Joint 360
Vol. 3, Issue 5 | Pages 18 - 20
1 Oct 2014

The October 2014 Wrist & Hand Roundup360 looks at: pulsed electromagnetic field of no use in acute scaphoid fractures; proximal interphalangeal joint replacement: one at a time or both at once; trapeziometacarpal arthrodesis in the young patient; Tamoxifen and Dupytren’s disease; and endoscopic or open for de Quervain’s syndrome?


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 130 - 130
1 Jul 2014
Schneider K Zderic I Gueorguiev B Richards R Nork S
Full Access

Summary. Biomechanically, a 2° screw deviation from the nominal axis in the PFLCP leads to significantly earlier implant failure. Screw deviation relies on a technical error on insertion, but in our opinion cannot be controlled intraoperatively with the existing instrumentation devices. Background. Several cases of clinical failure have been reported for the Proximal Femoral Locking Compression Plate (PFLCP). The current study was designed to investigate the failure mode and to explore biomechanically the underlying mechanism. Specifically, the study sought to determine if the observed failure was due to technical error on insertion or due to implant design. Methods. To exclude patient and fracture type related factors, an abstract foam block model simulating an unstable pertrochanteric fracture was created for three study groups with six specimens each (n=6). Group 1 was properly instrumented according to the manufacturer's guidelines. In Group 2 and 3, the first or second screw was placed in a posterior or anterior off-axis orientation by 2° measured in the transversal plane, respectively. Each construct was tested cyclically until failure using a test setup and protocol simulating complex axial and torsional loading. Radiographs were taken prior to and after the tests. Force, number of cycles and failure mode were compared. Results. The 2° screw deviation from the nominal axis led to significantly earlier construct failure in Group 2 and 3. The failure mode consisted of loosening of the off-axis screw due to disengagement with the plate, resulting in loss of construct stiffness and varus collapse of the fracture. Conclusions. In our biomechanical test setup, a screw deviation of only 2° from the nominal axis consistently led to the failure mode observed clinically. In our opinion, screw deviation mostly relies on technical error on insertion. But, proper screw insertion may be difficult or impossible with the existing instrumentation devices, especially as it cannot be controlled or guaranteed intraoperatively


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_2 | Pages 38 - 38
1 Jan 2014
Gadd R Barwick T Paling E Davies M Blundell C
Full Access

Introduction:. Prompted by the success of hip and knee arthroplasty, total ankle replacement (TAR) has become increasingly popular as a treatment for end stage arthritic complaints of the ankle. Glazebrook et al proposed a three grade classification of complications to assist prediction of early implant failure. We have compared the experience of a tertiary referral centre in the UK to Glazebrook's proposed system. Method:. A retrospective review of the Sheffield Foot and Ankle Unit TAR database was performed from 1995 to 2010. All complications were recorded and categorised using Glazebrook's proposed system. Glazebrook described eight main complications of increasing severity. Low grade complications; Post operative bone fracture, Intra-operative bone fracture and wound healing problems were very unlikely to lead to revision. Medium grade complications; technical error and subsidence, lead to failure < 50% of the time. High grade complications; deep infection, aseptic loosening and implant failure lead to revision > 50% of the time. Results:. 217 TAR were implanted in 198 patients with a minimum follow up of 30 months. The complication rate was 23% with a revision rate of 17%. All complications recorded in our study except intraoperative bone fracture and wound healing had a failure rate of at least 50%. Conclusion:. The proposed classification system of Glazebrook et al was the first step towards an international system of classifying TAR complications. Most complications associated with TAR have a significant impact on the lifespan of a TAR. Glazebrook et al's proposed three tier system did not reliably reflect our experience. We would categorise complications as either high or low risk for early failure of TAR


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 337 - 337
1 Mar 2013
Sonntag R Reinders J Rieger JS Jaeger S Kretzer JP
Full Access

Background. Titanium, in particular Ti6Al4V, is the standard material used in cementless joint arthroplasty. Implants are subjected to cyclic loading where fracture is the reason for re-operation in 1.5–2.4% of all revisions in total hip arthroplasty. In order to strengthen critical regions, surface treatments such as shot peening may be applied. A superficial titanium oxide layer is naturally formed on the surface as a protective film at ambient conditions. However, as its thickness is only in the range of several nanometers, it is prone to be destroyed by high loads - as present at the surface during bending - leading to an ‘oxidative wear’ in a corrosive environment [1]. The present study aims to evaluate the shot peening treatment on Ti6Al4V regarding its potential for cyclically loaded parts under a dry and a corrosive testing medium. Materials and Methods. Hour-glass shaped titanium specimens (Ti6Al4V) with a minimal diameter of 10 mm have been subjected to an annealing treatment at 620°C for 10h to remove initial residual stresses introduced during machining. Subsequently, a high-intensity shot peening treatment with cut wire followed by a low-intensity cleaning process with glass beads have been performed (Metal Improvement, Germany). Arithmetic mean roughness R. a. of the treated surfaces was measured (Mahr Perthometer M2, Germany). Residual stress depth profiles prior to and after shot peening have been measured by a Fe-filtered Co-K(alpha) radiation (GE Measurement&Control, USA) and calculated using the sin. 2. (psi) method. Fatigue strength has been determined by two servo-hydraulic hydropulsers (Bosch Rexroth, Germany) at 10 Hz and a load ratio of R=0.1 either under dry conditions (8 specimens) or surrounded by a 0.9-% saline solution (6 specimens) (BBraun, Germany) (Fig. 1). Testing has been performed until fracture occurred or the total number of 10 × 10. 6. cycles has been reached. All fracture surfaces have been analyzed after testing using FEG-SEM (Zeiss LEO 1530 VP Gemini, Germany). Results. Surface roughness increased significantly (p<0.01) after shot peening treatment from R. a, annealed. = 0.24 μm (±0.09 μm) to R. a, peened. = 2.02 μm (±0.16μm). Residual stresses have been introduced during shot peening up to a depth of 200μm with a maximum of 870 MPa at the surface (Fig. 2, left). All specimens showed clear signs of fatigue fracture after failure. Regarding fatigue strength, no differences have been observed between testing in saline solution or a dry environment (Fig. 2, right). Discussion. Shot peening has shown to significantly increase fatigue strength of a Ti6Al4V alloy after testing up to 10 × 10. 6. cycles. Thus, it seems to be an appropriate treatment for highly loaded components in cementless joint arthroplasty. In this context, a corrosive environment around a cyclically loaded implant does not seem to have any influence on their long term mechanical behaviour. However, it still needs to be clarified to which extend shot peening might decrease the risk of an early implant failure due to micro-motion between assembled parts (fretting) [2]