1 Oct 2024

The October 2024 Children’s orthopaedics Roundup360 looks at: Cost-effectiveness analysis of soft bandage and immediate discharge versus rigid immobilization in children with distal radius torus fractures: the FORCE trial; Percutaneous Achilles tendon tenotomy in clubfoot with a blade or a needle: a single-centre randomized controlled noninferiority trial; Treatment of hip displacement in children with cerebral palsy: a five-year comparison of proximal femoral osteotomy and combined femoral-pelvic osteotomy in 163 children; The Core outcome Clubfoot (CoCo) study: relapse, with poorer clinical and quality of life outcomes, affects 37% of idiopathic clubfoot patients; Retention versus removal of epiphyseal screws in paediatric distal tibial fractures: no significant impact on outcomes; Predicting the resolution of residual acetabular dysplasia after brace treatment in infant DDH; Low prevalence of acetabular dysplasia following treatment for neonatal hip instability: a long-term study; How best to distract the patient?.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1039 - 1043
1 Oct 2024
Luo TD Kayani B Magan A Haddad FS

The subject of noise in the operating theatre was recognized as early as 1972 and has been compared to noise levels on a busy highway. While noise-induced hearing loss in orthopaedic surgery specifically has been recognized as early as the 1990s, it remains poorly studied. As a result, there has been renewed focus in this occupational hazard. Noise level is typically measured in decibels (dB), whereas noise adjusted for human perception uses A-weighted sound levels and is expressed in dBA. Mean operating theatre noise levels range between 51 and 75 dBA, with peak levels between 80 and 119 dBA. The greatest sources of noise emanate from powered surgical instruments, which can exceed levels as high as 140 dBA. Newer technology, such as robotic-assisted systems, contribute a potential new source of noise. This article is a narrative review of the deleterious effects of prolonged noise exposure, including noise-induced hearing loss in the operating theatre team and the patient, intraoperative miscommunication, and increased cognitive load and stress, all of which impact the surgical team’s overall performance. Interventions to mitigate the effects of noise exposure include the use of quieter surgical equipment, the implementation of sound-absorbing personal protective equipment, or changes in communication protocols. Future research endeavours should use advanced research methods and embrace technological innovations to proactively mitigate the effects of operating theatre noise.

Cite this article: Bone Joint J 2024;106-B(10):1039–1043.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1165 - 1175
1 Oct 2024
Frost Teilmann J Petersen ET Thillemann TM Hemmingsen CK Olsen Kipp J Falstie-Jensen T Stilling M

Aims. The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA). Methods. Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom. Results. The greatest kinematic changes in the elbows were seen with the longest, + 4 mm, implant, which imposed a mean joint distraction of 2.8 mm in the radiohumeral joint and of 1.1 mm in the ulnohumeral joint, an increased mean varus angle of up to 2.4° for both the radius and the ulna, a mean shift of the radius of 2.0 mm in the ulnar direction, and a mean shift of the ulna of 1.0 mm posteriorly. Conclusion. The kinematics of the elbow deviated increasingly from those of the native joint with a 2 mm to a 4 mm lengthening of the radius. This confirms the importance of restoring the natural length of the radius when undertaking RHA. Cite this article: Bone Joint J 2024;106-B(10):1165–1175


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 52 - 52
19 Aug 2024
Malhotra R Parameswaran A Gautam D Batra S Apsingi S Kishore V Eachempati KK
Full Access

Chronic pelvic discontinuity (CPD) during revision hip arthroplasty is a challenging entity to address. The aim of this study was to evaluate the clinical and radiologic outcomes, and complications of the “acetabular distraction technique” for the management of CPD during revision hip arthroplasty. Patients with CPD, who underwent acetabular revision between 2014 and 2022 at two tertiary care centres, using an identical distraction technique, were evaluated. Demographic parameters, pre-operative acetabular bone loss, duration of follow-up, clinical and radiologic outcomes, and survivorship were evaluated. In all, 46 patients with a mean follow-up of 34.4 (SD=19.6, range: 24–120) months were available for evaluation. There were 25 (54.3%) male, and 21 (45.7%) female patients, with a mean age of 58.1 (SD=10.5, range: 40–81) years at the time of revision surgery. Based on the Paprosky classification of acetabular bone loss, 19 (41.3%), 12 (26.1%), and 15 (32.6%) patients had type 3b, 3a, and 2c defects. All patients were managed using the Trabecular Metal™ Acetabular Revision System; 16 patients required additional Trabecular Metal™ augments. The mean HHS improved from 50.1 (SD=7.6, range: 34.3 – 59.8) pre-operatively, to 86.6 (SD=4.2, range: 74.8 -91.8) at the last follow-up. Two patients (4.3 %) developed partial sciatic nerve palsy, two (4.3%) had posterior dislocation, and one (2.2%) required re-revision for aseptic loosening. Radiologically, 36 (78.3%) patients showed healing of the pelvic discontinuity. The Kaplan-Meier construct survivorship was 97.78% when using re-revision for aseptic acetabular loosening as an endpoint. The acetabular distraction technique has good clinical and radiologic outcomes in the management of CPD during revision hip arthroplasty


The Paprosky acetabular bone defect classification system and related algorithms for acetabular reconstruction cannot properly guide cementless acetabular reconstruction in the presence of porous metal augments. We aimed to introduce a rim, points, and column (RPC)-oriented cementless acetabular reconstruction algorithm and its clinical and radiographic outcomes. A total of 123 patients (128 hips) were enrolled. A minimum 5-year radiographic follow-up was available for 96 (75.8%) hips. The mean clinical and radiographic follow-up durations were 6.8±0.9 (range: 5.2–9.2) and 6.3±1.9 (range: 5.0–9.2) years, respectively. Harris hip score (HHS) improved significantly from 35.39±9.91 preoperatively to 85.98±12.81 postoperatively (P<0.001). Among the fixation modes, 42 (32.8%) hips were reconstructed with rim fixation, 42 (32.8%) with three-point fixation without point reconstruction, 40 (31.3%) with three-point fixation combined with point reconstruction, and 4 (3.1%) with three-point fixation combined with pelvic distraction. Complementary medial wall reconstruction was performed in 20 (15.6%) patients. All acetabular components were radiographically stable. Nine-year cumulative Kaplan–Meier survival rates for 123 patients with the endpoint defined as periprosthetic joint infection, any reoperation, and dissatisfaction were 96.91% (confidence interval [CI]: 86.26%, 99.34%), 97.66% (CI: 92.91%, 99.24%), and 96.06% (CI: 86.4%, 98.89%), respectively. Cup stability in cementless acetabular reconstruction depends on rim or three-point fixation. The continuity of the anterior and posterior columns determines whether the points provide adequate stability to the cup. Medial wall reconstruction is an important complementary fixation method for rim or three-point fixation. The patients who underwent cementless acetabular reconstruction guided by the RPC decision-making algorithm demonstrated satisfactory mid-term clinical function, satisfaction levels, radiographic results, and complication rates


Bone & Joint Open
Vol. 5, Issue 7 | Pages 581 - 591
12 Jul 2024
Wang W Xiong Z Huang D Li Y Huang Y Guo Y Andreacchio A Canavese F Chen S

Aims. To investigate the risk factors for unsuccessful radial head reduction (RHR) in children with chronic Monteggia fractures (CMFs) treated surgically. Methods. A total of 209 children (mean age 6.84 years (SD 2.87)), who underwent surgical treatment for CMFs between March 2015 and March 2023 at six institutions, were retrospectively reviewed. Assessed risk factors included age, sex, laterality, dislocation direction and distance, preoperative proximal radial metaphysis width, time from injury to surgery, reduction method, annular ligament reconstruction, radiocapitellar joint fixation, ulnar osteotomy, site of ulnar osteotomy, preoperative and postoperative ulnar angulation, ulnar fixation method, progressive ulnar distraction, and postoperative cast immobilization. Independent-samples t-test, chi-squared test, and logistic regression analysis were used to identify the risk factors associated with unsuccessful RHR. Results. Redislocation occurred during surgery in 48 patients (23%), and during follow-up in 44 (21.1%). The mean follow-up of patients with successful RHR was 13.25 months (6 to 78). According to the univariable analysis, time from injury to surgery (p = 0.002) and preoperative dislocation distance (p = 0.042) were identified as potential risk factors for unsuccessful RHR. However, only time from injury to surgery (p = 0.007) was confirmed as a risk factor by logistic regression analysis. Receiver operating characteristic curve analysis and chi-squared test confirmed that a time from injury to surgery greater than 1.75 months increased the rate of unsuccessful RHR above the cutoff (p = 0.002). Conclusion. Time from injury to surgery is the primary independent risk factor for unsuccessful RHR in surgically treated children with CMFs, particularly in those with a time from injury to surgery of more than 1.75 months. No other factors were found to influence the incidence of unsuccessful RHR. Surgical reduction of paediatric CMFs should be performed within the first two months of injury whenever possible. Cite this article: Bone Jt Open 2024;5(7):581–591


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 751 - 758
1 Jul 2024
Yaxier N Zhang Y Song J Ning B

Aims

Given the possible radiation damage and inaccuracy of radiological investigations, particularly in children, ultrasound and superb microvascular imaging (SMI) may offer alternative methods of evaluating new bone formation when limb lengthening is undertaken in paediatric patients. The aim of this study was to assess the use of ultrasound combined with SMI in monitoring new bone formation during limb lengthening in children.

Methods

In this retrospective cohort study, ultrasound and radiograph examinations were performed every two weeks in 30 paediatric patients undergoing limb lengthening. Ultrasound was used to monitor new bone formation. The number of vertical vessels and the blood flow resistance index were compared with those from plain radiographs.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 728 - 734
1 Jul 2024
Poppelaars MA van der Water L Koenraadt-van Oost I Boele van Hensbroek P van Bergen CJA

Aims

Paediatric fractures are highly prevalent and are most often treated with plaster. The application and removal of plaster is often an anxiety-inducing experience for children. Decreasing the anxiety level may improve the patients’ satisfaction and the quality of healthcare. Virtual reality (VR) has proven to effectively distract children and reduce their anxiety in other clinical settings, and it seems to have a similar effect during plaster treatment. This study aims to further investigate the effect of VR on the anxiety level of children with fractures who undergo plaster removal or replacement in the plaster room.

Methods

A randomized controlled trial was conducted. A total of 255 patients were included, aged five to 17 years, who needed plaster treatment for a fracture of the upper or lower limb. Randomization was stratified for age (five to 11 and 12 to 17 years). The intervention group was distracted with VR goggles and headphones during the plaster treatment, whereas the control group received standard care. As the primary outcome, the post-procedural level of anxiety was measured with the Child Fear Scale (CFS). Secondary outcomes included the children’s anxiety reduction (difference between CFS after and CFS before plaster procedure), numerical rating scale (NRS) pain, NRS satisfaction of the children and accompanying parents/guardians, and the children’s heart rates during the procedure. An independent-samples t-test and Mann-Whitney U test (depending on the data distribution) were used to analyze the data.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 596 - 602
1 Jun 2024
Saarinen AJ Sponseller P Thompson GH White KK Emans J Cahill PJ Hwang S Helenius I

Aims. The aim of this study was to compare outcomes after growth-friendly treatment for early-onset scoliosis (EOS) between patients with skeletal dysplasias versus those with other syndromes. Methods. We retrospectively identified 20 patients with skeletal dysplasias and 292 with other syndromes (control group) who had completed surgical growth-friendly EOS treatment between 1 January 2000 and 31 December 2018. We compared radiological parameters, complications, and health-related quality of life (HRQoL) at mean follow-up of 8.6 years (SD 3.3) in the dysplasia group and 6.6 years (SD 2.6) in the control group. Results. Mean major curve correction per patient did not differ significantly between the dysplasia group (43%) and the control group (28%; p = 0.087). Mean annual spinal height increase was less in the dysplasia group (9.3 mm (SD 5.1) than in the control group (16 mm (SD 9.2); p < 0.001). Mean annual spinal growth adjusted to patient preoperative standing height during the distraction period was 11% in the dysplasia group and 14% in the control group (p = 0.070). The complication rate was 1.6 times higher (95% confidence interval (CI) 1.3 to 2.0) in the dysplasia group. The following complications were more frequent in the dysplasia group: neurological injury (rate ratio (RR) 5.1 (95% CI 2.3 to 11)), deep surgical site infection (RR 2.2 (95% CI 1.2 to 4.1)), implant-related complications (RR 2.0 (95% CI 1.5 to 2.7)), and unplanned revision (RR 1.8 (95% CI 1.3 to 2.5)). Final fusion did not provide additional spinal height compared with watchful waiting (p = 0.054). There were no significant differences in HRQoL scores between the groups. Conclusion. After growth-friendly EOS treatment, patients with skeletal dysplasias experienced a higher incidence of complications compared to those with other syndromes. Surgical growth-friendly treatment for skeletal dysplasia-associated EOS should be reserved for patients with severe, progressive deformities that are refractory to nonoperative treatment. Cite this article: Bone Joint J 2024;106-B(6):596–602


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 66 - 73
1 May 2024
Chaudhry F Daud A Greenberg A Braunstein D Safir OA Gross AE Kuzyk PR

Aims

Pelvic discontinuity is a challenging acetabular defect without a consensus on surgical management. Cup-cage reconstruction is an increasingly used treatment strategy. The present study evaluated implant survival, clinical and radiological outcomes, and complications associated with the cup-cage construct.

Methods

We included 53 cup-cage construct (51 patients) implants used for hip revision procedures for pelvic discontinuity between January 2003 and January 2022 in this retrospective review. Mean age at surgery was 71.8 years (50.0 to 92.0; SD 10.3), 43/53 (81.1%) were female, and mean follow-up was 6.4 years (0.02 to 20.0; SD 4.6). Patients were implanted with a Trabecular Metal Revision Shell with either a ZCA cage (n = 12) or a TMARS cage (n = 40, all Zimmer Biomet). Pelvic discontinuity was diagnosed on preoperative radiographs and/or intraoperatively. Kaplan-Meier survival analysis was performed, with failure defined as revision of the cup-cage reconstruction.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 9 - 9
23 Apr 2024
Ramlawi AA McClure P Assayag M
Full Access

Introduction. The practice of limb lengthening using intramedullary nails has surged in popularity in recent years. Our study explores the relationship between femur lengthening and overall height gain in adults undergoing cosmetic limb lengthening with telescoping magnetic intramedullary lengthening nails (MILNs). Materials & Methods. Demographic information, pre- and postoperative radiographic data, and secondary outcomes, such as mechanical angles and sagittal alignment, were analyzed for 42 adult femurs MILNs (PRECICE 2, NuVasive, Inc.). Height was assessed with a digital stadiometer. Limb lengthening was defined as the amount of nail distraction seen on a calibrated weight bearing X-ray at consolidation. mLDFA, mMPTA, MAD, AMA, and femoral sagittal bow were evaluated as secondary outcomes. Results. Mean starting height was 163.5 cm (SD 10.4, range 137–179) Post -lengthening mean height increased to 171.1 cm (SD 10.1, range 146.7–185.3). Average height gain was 7.5 cm (SD 1.3 cm, range 5.1–9.5). Average femoral lengthening was 7.3 cm (SD 1.14, range 4.1–10.1). There were no statistically significant difference between height gain and femur lengthening. Secondary outcomes showed reductions in femoral sagittal bow and AMA. Conclusions. We conclude that measuring femur lengthening is a reliable and accurate method of measuring gained height in deformity-free patients undergoing limb lengthening. We further reason that straightening of both femoral and spinal sagittal bow counteracts potential lengthening loss over the anatomical axis, versus mechanical axis lengthening


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 5 - 5
23 Apr 2024
Sain B Sidharthan S Naique S
Full Access

Introduction. Treatment of non-union in open tibial fractures Gustilo-Anderson(GA)-3A/3B fractures remains a challenging problem. Most of these can be dealt using treatment methods that requires excision of the non-union followed by bone grafting, masquelet technique, or acute shortening. Circular fixators with closed distraction or bone transport also remains a useful option. However, sometimes due to patient specific factors these cannot be used. Recently antibiotic loaded bone substitutes have been increasingly used for repairing infected non-unions. They provide local antibiotic delivery, fill dead space, and act as a bone conductive implant, which is resorted at the end of a few months. We aimed to assess the outcome of percutaneous injection of bone substitute while treating non-union of complex open tibial fractures. Materials & Methods. Three cases of clinical and radiological stiff tibial non-union requiring further intervention were identified from our major trauma open fracture database. Two GA-3B cases, treated with a circular frame developed fracture-related-infection(FRI) manifesting as local cellulitis, loosened infected wires/pins with raised blood-markers, and one case of GA-3A treated with an intramedullary nail. At the time of removal of metalwork/frame, informed consent was obtained and Cerament-G. TM. (bone-substitute with gentamicin) was percutaneously injected through a small cortical window using a bone biopsy(Jamshedi needle). All patients were allowed to weight bear as tolerated in a well-fitting air-cast boot and using crutches. They were followed up at 6 weekly intervals with clinical assessment of their symptoms and radiographs. Fracture union was assessed using serial radiographs with healing defined as filling of fracture gap, bridging callus and clinical assessment including return to full painless weight bearing. Results. Follow-up at 6 months showed all fractures had healed with no defect or gaps with evidence of new trabecular bone and significant resorption of Cerament-G. TM. at final follow-up. There was no evidence of residual infection with restoration of normal limb function. Fractures with no internal fixation showed a mild deformity that had developed during the course of the healing, presumed due to mild collapse in the absence of fixation. These were less than 10 degrees in sagittal and coronal planes and were clinically felt to be insignificant by the patients. Conclusions. Cerament-G's unique combination of high dose antibiotics and hydroxy apatite matrix provided by calcium sulphate might help provide an osteoconductive environment to allow these stiff non-unions to heal. The matrix appears to provide a scaffold-like structure that allows new bone in-growth with local release of antibiotics helping reduce deep-seated infections. The final deformation at fracture site underlines the need for fixation- and it is very unlikely that this technique will work in mobile nonunions. Whilst similar fractures may heal without the use of bone substitute injections, the speed of healing in presence of significant fracture gap suggests the use of these bone substitutes did help in our cases. Further studies with a larger cohort, including RCTs, to evaluate the effectiveness of this technique compared to other methods are needed


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 11 - 11
23 Apr 2024
Lineham B Faraj A Hammet F Barron E Hadland Y Moulder E Muir R Sharma H
Full Access

Introduction. Intra articular distal tibia fractures can lead to post-traumatic osteoarthritis. Joint distraction has shown promise in elective cases. However, its application in acute fractures remains unexplored. This pilot study aims to fill this knowledge gap by investigating the benefits of joint distraction in acute fractures. Materials & Methods. We undertook a restrospective cohort study comprising patients with intra-articular distal tibia and pilon fractures treated with a circular ring fixator (CRF) at a single center. Prospective data collection included radiological assessments, Patient-Reported Outcome Measures (PROM), necessity for additional procedures, and Kellgren and Lawrence grade (KL) for osteoarthritis (OA). 137 patients were included in the study, 30 in the distraction group and 107 in the non-distraction group. There was no significant difference between the groups. Results. Mean follow-up was 3.73 years. There was no significant difference between the groups in overall complications or need for further procedures. There was no significant difference in progression of KL between the groups (1.81 vs 2.0, p=0.38) mean follow up 1.90 years. PROM data was available for 44 patients (6 distraction, 38 non-distraction) with a mean follow-up of 1.71 years. There was no significant difference in EQ5D (p=0.32) and C Olerud-H Molander scores (p=0.17). Conclusions. This pilot study suggests that joint distraction is safe in the acute setting. However, the study's impact is constrained by a relatively small patient cohort and a short-term follow-up period. Future investigations should prioritise longer-term follow-ups and involve a larger patient population to more comprehensively evaluate the potential benefits of joint distraction in acute fractures


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 20 - 20
23 Apr 2024
Guichet J
Full Access

Introduction. Frame HI is the #Days for device removal/cm. IM Nail HI is less relevant (31–45 D/cm). Albizzia HI was 33 D/cm (1991–2003). Patients felt fine approximately 1M after end of lengthening (EoL), resuming normal life and sports. This sometimes resulted in implants fractures (e.g. skying before bone fusion). Ideally, the full fusion should occur at the EoL. We decided to shorten the HI to reach this target, optimising all parameters. Materials & Methods. The evolution of care has been monitored over a 32-year clinical experience with a fully weight-bearing nails (Albizzia then G-nail). Monitoring was with X-rays, DEXA, blood bone activity, and in London with special 5G CBCT Scans. We implemented several changes in the Care of patients and measured them according to the ‘Five Principles’ (stability, function, ‘Roads-vascular supply’, ‘Materials-calories’ and ‘Workers-BFC’, with actions on food intake, activity levels and on muscle and bone vascular growths. Results. Preop: training (vascularity, muscle force). Op & Postop: spine morphine, IM sawing preserving BFC, controlled hypo-pressure, low hydration, 50 cm leg elevation, walking, resistance bike, full motion (drainage, muscle reactivation), discharge 3–4h postop (including bilateral). Postop daily intense gym training. POD07-21: Distraction increased to fight non-linear hyper-ossification (44–50 mm gain at POD30) +/- aided by NSAIDs. HI decreased to 12–20D/cm, sometimes 8D/cm with some ‘soft fusion’ during lengthening, hardening within 1W after EoL. Conclusions. The surgeon is not a passive X-rays observer, but has an active role in changing the healing speed and decreasing HI for patient safety. Electro/Magnetic nails (torque 1 Nm) may be clocked by bone fusion, which does not occur with the G-Nail (19 Nm). An holistic vision for patients and treatments at several levels is essential to accelerate bone healing, and to return fast to full normal life, after a short ‘lengthening parenthesis’


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 352 - 358
1 Apr 2024
Wilson JM Trousdale RT Bedard NA Lewallen DG Berry DJ Abdel MP

Aims

Dislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct.

Methods

We identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m2 (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97).


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 110 - 114
1 Mar 2024
Yee AHF Chan VWK Fu H Chan P Chiu KY

Aims

The aim of this study was to evaluate the survival of a collarless, straight, hydroxyapatite-coated femoral stem in total hip arthroplasty (THA) at a minimum follow-up of 20 years.

Methods

We reviewed the results of 165 THAs using the Omnifit HA system in 138 patients, performed between August 1993 and December 1999. The mean age of the patients at the time of surgery was 46 years (20 to 77). Avascular necrosis was the most common indication for THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (20 to 31). At 20 and 25 years, 113 THAs in 91 patients and 63 THAs in 55 patients were available for review, respectively, while others died or were lost to follow-up. Kaplan-Meier analysis was performed to evaluate the survival of the stem. Radiographs were reviewed regularly, and the stability of the stem was evaluated using the Engh classification.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 293 - 302
1 Mar 2024
Vogt B Lueckingsmeier M Gosheger G Laufer A Toporowski G Antfang C Roedl R Frommer A

Aims. As an alternative to external fixators, intramedullary lengthening nails (ILNs) can be employed for distraction osteogenesis. While previous studies have demonstrated that typical complications of external devices, such as soft-tissue tethering, and pin site infection can be avoided with ILNs, there is a lack of studies that exclusively investigated tibial distraction osteogenesis with motorized ILNs inserted via an antegrade approach. Methods. A total of 58 patients (median age 17 years (interquartile range (IQR) 15 to 21)) treated by unilateral tibial distraction osteogenesis for a median leg length discrepancy of 41 mm (IQR 34 to 53), and nine patients with disproportionate short stature treated by bilateral simultaneous tibial distraction osteogenesis, with magnetically controlled motorized ILNs inserted via an antegrade approach, were retrospectively analyzed. The median follow-up was 37 months (IQR 30 to 51). Outcome measurements were accuracy, precision, reliability, bone healing, complications, and patient-reported outcome assessed by the Limb Deformity-Scoliosis Research Society Score (LD-SRS-30). Results. A median tibial distraction of 44 mm (IQR 31 to 49) was achieved with a mean distraction index of 0.5 mm/day (standard deviation 0.13) and median consolidation index of 41.2 days/cm (IQR 34 to 51). Accuracy, precision, and reliability were 91%, 92%, and 97%, respectively. New temporary range of motion limitations occurred in 51% of segments (34/67). Distraction-related equinus deformity treated by Achilles tendon lengthening was the most common major complication recorded in 16% of segments (11/67). In 95% of patients (55/58) the distraction goal was achieved with 42% unplanned additional interventions per segment (28/67). The median postoperative LD-SRS-30 score was 4.0 (IQR 3.6 to 4.3). Conclusion. Tibial distraction osteogenesis using motorized ILNs inserted via an antegrade approach appears to be a reliable and precise procedure. Temporary joint stiffness of the knee or ankle should be expected in up to every second patient. A high rate and wide range of complications of variable severity should be anticipated. Cite this article: Bone Joint J 2024;106-B(3):293–302


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims

Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm.

Methods

An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score.


Bone & Joint 360
Vol. 13, Issue 1 | Pages 7 - 8
1 Feb 2024
Jamal B Round J Qureshi A


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 53 - 61
1 Jan 2024
Buckland AJ Huynh NV Menezes CM Cheng I Kwon B Protopsaltis T Braly BA Thomas JA

Aims

The aim of this study was to reassess the rate of neurological, psoas-related, and abdominal complications associated with L4-L5 lateral lumbar interbody fusion (LLIF) undertaken using a standardized preoperative assessment and surgical technique.

Methods

This was a multicentre retrospective study involving consecutively enrolled patients who underwent L4-L5 LLIF by seven surgeons at seven institutions in three countries over a five-year period. The demographic details of the patients and the details of the surgery, reoperations and complications, including femoral and non-femoral neuropraxia, thigh pain, weakness of hip flexion, and abdominal complications, were analyzed. Neurological and psoas-related complications attributed to LLIF or posterior instrumentation and persistent symptoms were recorded at one year postoperatively.