Indication for a TOFEM was fracture in 43%, bone loss in 51% and others in 6 %. Infection occurred at primary intervention in 32%, in connection with revisions in 18% or delayed in 49%.
This technical choice constitutes an effective solution for all those cases where, due to the infective damage, the radical surgical debridement needed or in presence of a septic pseudoarthrosis, there is a relevant loss of bone stock in the proximal femur. As a treatment for these specific clinical patterns oncological prosthetic implants can be used, to overcome the amount of bone loss. Sometimes acetabular prosthetic implantation, or reimplantation, is also needed because of its septic mobilization, otherwise a bicentric endoprosthesis can be implanted. The main issue for the surgeon is the gluteal muscular deficiency, caused often by the loss of the great trochanter, a severe condition often worsened by the damage on muscles and soft tissues given by previous surgical procedures and debridements. The offset itself, really often not sufficient for the limited amount of sizes and lengths of the oncological designed prosthetic implants, represent a key issue of this treatment with a high luxation risk, with a higher rate in those cases when an arthroprosthesis has been performed. In this article are described 4 cases, all four treated with a two-stage surgical approach and a definitive oncological prosthetic system to overcome the severe bone loss of the proximal femur. The cases are examined about the surgical indication to this prosthetic choice, the postoperative period with the related complications (1 case of recurrent luxation) and with a minimum follow up of 6 months (maximum 36 months). In all the cases at the follow up the infection is solved. At the end the specific rehabilitation program for the range of motion and the muscular strength regain, that we developed in our Operative Unit is described; in this program we occasionally used for the immediate post surgery period a jointed hip brace. The length of the rehabilitation could not be standard, but should be customized and variations of the program could be done during the follow up. In the immediate post-surgical period the rehabilitative goals are maintaining the correct posture in bed and regaining the passive articular range of motion. In the longer period the main goals are regain strength of the gluteal muscles, proprioception and gait, even if claudication (Trendelemburg), hyposthenia a recurrent dislocation can be let. The weight bearing is allowed usually at the eight week after surgery, but only after clinical and x-ray evaluation.
Aim. Low-grade infections cannot be easily distinguished from aseptic complications frequently leading to false negative diagnoses and late onset of anti-bacterial therapy. Therefore, there is a great need to establish biomarkers for early detection of low-grade infections. Method. In this study, we focused on the investigation of anti-α-defensin, anti-C3, anti-C5 and anti-C9 as potential biomarkers for infection in a cohort of hip and knee septic revision cases, taking patient characteristics and comorbidities into account. Here we included 78 patients with septic (35) and aseptic (43) (woman:37, men:42, age 50 – 93 years)
INTRODUCTION. The diagnosis of peri-prosthetic infection may be difficult. But this diagnosis can guide antibiotic prophylaxis and implementation of intraoperative bacteriological samples. The hypothesis of this study was that a composite score using clinical, radiological and biological data could be used for positive and negative diagnostic of infection before reoperation on prosthetic hip or knee. MATERIAL. 200
Although cemented fixation provides excellent results in primary total hip replacement (THR), particularly in patients older than 75 years, uncemented implants are most commonly used nowadays. We compare the rate of complications, clinical and radiological results of three different designs over 75-years-old patients. 433 hips implanted in patients over 75 years old were identified from our Local Joint Registry. Group A consisted of 139 tapered cemented hips, group B of 140 tapered grit-blasted uncemented hips and group C of 154 tapered porous-coated uncemented hips. A 28 mm femoral head size on polyethylene was used in all cases. The mean age was greater in group A and the physical activity level according to Devane was lower in this group (p<0.001 for both variables). Primary osteoarthritis was the most frequent diagnoses in all groups. The radiological acetabular shape was similar according to Dorr, however, an osteopenic-cylindrical femur was most frequently observed in group A (p<0.001). The pre- and post-operative clinical results were evaluated according to the Merle-D'Aubigne and Postel scale. Radiological cup position was assessed, including hip rotation centre distance according to Ranawat and cup anteversion according to Widmer. We also evaluated the lever arm and height of the greater trochanter distances and the stem position. Kaplan-Meier analysis was done for revision for any cause and loosening. The hip rotation centre distance was greater and the height of the greater trochanter was lower in group B (p=0.003, p<0.001, respectively). The lever arm distance was lower in group C (p<0.001). A varus stem position was more frequently observed in group B (p<0.001). There were no intra- or post-operative fractures in group A, although there were five intra-operative fractures in the other groups plus two post-operative fractures in group B and four in group C. The rate of dislocation was similar among groups and was the most frequent cause for
Although cemented fixation provides excellent results in primary total hip replacement (THR), particularly in patients older than 75 years, uncemented implants are most commonly used nowadays. We compare the rate of complications, clinical and radiological results of three different designs over 75-years-old patients. Materials and Methods. 433 hips implanted in patients over 75 years old were identified from our Local Joint Registry. Group A consisted of 139 tapered cemented hips, group B of 140 tapered grit-blasted uncemented hips and group C of 154 tapered porous-coated uncemented hips. A 28 mm femoral head size on polyethylene was used in all cases. The mean age was greater in group A and the physical activity level according to Devane was lower in this group (p<0.001 for both variables). Primary osteoarthritis was the most frequent diagnoses in all groups. The radiological acetabular shape was similar according to Dorr, however, an osteopenic-cylindrical femur was most frequently observed in group A (p<0.001). The pre- and post-operative clinical results were evaluated according to the Merle-D'Aubigne and Postel scale. Radiological cup position was assessed, including hip rotation centre distance according to Ranawat and cup anteversion according to Widmer. We also evaluated the lever arm and height of the greater trochanter distances and the stem position. Kaplan-Meier analysis was done for revision for any cause and loosening. Results. The hip rotation centre distance was greater and the height of the greater trochanter was lower in group B (p=0.003, p<0.001, respectively). The lever arm distance was lower in group C (p<0.001). A varus stem position was more frequently observed in group B (p<0.001). There were no intra- or post-operative fractures in group A, although there were five intra-operative fractures in the other groups plus two post-operative fractures in group B and four in group C. The rate of dislocation was similar among groups and was the most frequent cause for
Introduction:. The outcome of previous cemented total hip arthroplasty has been reported to be inferior in renal transplant patients because of poor bone stock resulting from long-term steroid use. Moreover, as renal transplant patients remain on immunosuppressant therapy for life, higher levels of overall morbidity must be considered. We evaluated the mid-term results of cementless total hip arthroplasty in renal transplant recipients with osteonecrosis of the femoral head, and compared those with age and sex matched osteonecrosis patients that had not undergone organ transplantation or been treated with long-term steroid. Materials & Methods:. Between October 1997 and October 2008, 45 consecutive primary cementless total hip arthroplasties were performed in 30 patients with advanced osteonecrosis of the femoral head after renal transplantation. There were 18 males (27 hips) and 12 females (18 hips) of overall mean age 44 years (22 to 68). The clinical and radiographic results of cementless total hip arthroplasty in these 45 hips were compared with those of 96 sex and age-matched osteonecrotic hips of 72 patients that had not undergone organ transplantation or long-term steroid use. Patients were evaluated at surgery and at a mean of 7.2 years (range, 2–13 years) postoperatively. Results:. The mean Harris hip score of patients improved from 48 points preoperatively to 94 points at last follow-up (p < 0.05). Three hips in patient group had massive osteolysis with polyethylene wear requiring
Background. Ultrasound and MRI are recommended tools in evaluating postoperative pain in metal-on-metal hip (MoM) arthroplasty. Aim. To retrospectively compare MRI and ultrasound results of the hip with histopathology results in failed (MoM) hip arthroplasty. Methods. 25 hips (16 patients) who underwent revision hip surgery for painful (MoM) hip replacement/resurfacing were included in this study (March 2011 to May 2012). Average age 50.4 yrs (37–69y). Blood test for cobalt and chromium levels, ultrasound and MRI were done prior to
Introduction. Total femur implantation is a rare and challenging procedure in final
Aim: To determine the outcome and need for subsequent surgery in patients following successful closed reduction of dislocation after primary total hip arthroplasty (THA) and the financial implications of re-operation. Methods: Data was retrospectively obtained from radiographs and patient case notes for all dislocated primary hip replacements presenting to the University Hospital of Wales from January 2000 till November 2005. Records were analysed with a minimum of 1 year follow-up to determine the outcome and need for subsequent surgery following successful closed reduction of dislocation after primary THA. Factors studied include age at primary surgery, indications, components, approach, head size, duration since surgery and direction of dislocation. Results: Over the 6 year study period, 98 patients presented with 100 first time dislocated primary total hip replacements. All the dislocations underwent successful closed reduction. 62 (62%) hips re-dislocated more that once. At minimum follow up of 1 year, 7 patients had died and were excluded from the final study group. Of the remaining 93 hips, 46 patients have had no further surgery. 44 THA’s have undergone revision procedures and 3 are waiting to have revision surgery (51% in total). Of those who have undergone
Introduction: There has been a proliferation of newer fluted tapered grit-blasted titanium stems in hip revision arthroplasty. However, only a limited number of clinical series have so far been reported in the literature. Moreover, all reports have only a short-term clinical and radiographical follow-up (<
5 years). Medium-term and long-term follow-up studies are lacking. Therefore, the aim of this study was to review a series of a cementless modular tapered revision femoral component (MP Link hip reconstruction prosthesis) with a minimum 5 year follow-up. Patients and Methods: This study includes 90 consecutive cases (87 patients) with the MP stem. We documented the Harris hip score (HHS) and the Visual analogue scale (VAS) was used to assess pain at rest and movement. Survivorship was calculated using Kaplan-Meier survival analysis. The 95% confidence intervals (CI) for the cumulative 5 year survival were calculated. Radiographs made immediately after the index operation were compared with those at follow-up examination in order to classify the restoration of femoral bone and vertical migration of the implant. Results: Of the original 90 cases, 24 (27%) died prior to clinical and radiographical review, 2 (2%) had a stem revision and 1 (1%) was lost to follow-up. Patients who died and were lost to follow-up were included in the survival analysis. For those patients, all data concerning complications and revisions were extracted from journal files and the Swedish Hip Register which collects all information on
In using the S-ROM proximally supported, modular stem for