Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Applied filters
The Bone & Joint Journal

Include Proceedings
Dates
Year From

Year To
The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1018 - 1024
1 Aug 2018
Ando W Yasui H Yamamoto K Oinuma K Tokunaga H Inaba Y Kobayashi N Aihara M Nakanishi R Ohzono K

Aims

The purpose of this study was to compare two different types of metal-on-metal (MoM) bearing for total hip arthroplasty (THA): one with a large femoral head (38 mm to 52 mm) and the other with a conventional femoral head (28 mm or 32 mm). We compared clinical outcome, blood metal ion levels, and the incidence of pseudotumour in the two groups.

Patients and Methods

Between December 2009 and December 2011, 62 patients underwent MoM THA with a large femoral head (Magnum group) and 57 patients an MoM THA with a conventional femoral head (conventional group). Clinical outcome was assessed using the Harris Hip score, University of California, Los Angeles (UCLA) activity score and EuroQol-5D (EQ-5D). Blood metal ion levels were measured and MRI scans were analyzed at a minimum of five years postoperatively.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1194 - 1200
1 Sep 2011
Akiyama H Yamamoto K Tsukanaka M Kawanabe K Otsuka H So K Goto K Nakamura T

We retrospectively reviewed 40 hips in 36 patients who had undergone acetabular reconstruction using a titanium Kerboull-type acetabular reinforcement device with bone allografts between May 2001 and April 2006. Impacted bone allografts were used for the management of American Academy of Orthopaedic Surgeons Type II defects in 17 hips, and bulk bone allografts together with impacted allografts were used for the management of Type III defects in 23 hips. A total of five hips showed radiological failure at a mean follow-up of 6.7 years (4.5 to 9.3), two of which were infected. The mean pre-operative Merle d’Aubigné score was 10 (5 to 15) vs 13.6 (9 to 18) at the latest follow-up. The Kaplan-Meier survival rate at ten years, calculated using radiological failure or revision of the acetabular component for any reason as the endpoint, was 87% (95% confidence interval 76.3 to 97.7). A separate experimental analysis of the mechanical properties of the device and the load-displacement properties of bone grafts showed that a structurally hard allograft resected from femoral heads of patients with osteoarthritis should be preferentially used in any type of defect. If impacted bone allografts were used, a bone graft thickness of < 25 mm was acceptable in Type II defects.

This clinical study indicates that revision total hip replacement using the Kerboull-type acetabular reinforcement device with bone allografts yielded satisfactory mid-term results.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 460 - 464
1 May 1995
Teshima R Otsuka T Takasu N Yamagata N Yamamoto K

We studied the most superficial layer of macroscopically normal articular cartilage obtained from human femoral heads, using polarising microscopy and SEM. The most superficial layer, 4 to 8 microns thick, was acellular consisting of collagen fibrils. This layer could be peeled away as a thin film, with no broken collagen fibrils on its inferior surface or on the surface of subjacent cartilage layers. The orientation and diameter of collagen fibrils were different on these two surfaces. Our findings suggest that the most superficial layer is an independent one which is only loosely connected to the fibrous structure in the layer deep to it.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 829 - 831
1 Nov 1988
Kawai H Yamamoto K

Delayed union or non-union of the scaphoid was treated by a bone graft on a pronator quadratus pedicle in eight cases. This produced earlier union than the Russe procedure. The procedure is simple and is recommended for old un-united scaphoid fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 287 - 292
1 Mar 1988
Kawai H Yamamoto K Yamamoto T Tada K Kaga K

Excision of the lunate was performed for 18 patients with Kienbock's disease; 14 were followed up for an average of almost 12 years. Carpal collapse progressed with time, but rearrangement of the remaining carpal bones preserved a satisfactory range of movement and grip strength. Degenerative changes were not severe. All the patients had relief of pain, were able to carry out their normal activities, and all but two could perform strenuous activities.