We investigated the extent to which improved
balance relative to pain relief correlates with the success of total knee
replacement (TKR). A total of 81 patients were recruited to the
study: 16 men (19.8%) and 65 women (80.2%). Of these, 62 patients
(10 men, 52 women) with a mean age of 73 (57 to 83) underwent static
and dynamic assessment of balance pre-operatively and one year post-operatively.
The parameters of balance were quantified using commercially available
and validated equipment. Motor function and self-reported outcome
were also assessed. There was a significant improvement in dynamic balance (p <
0.001) one year after TKR, and better balance correlated with improved
mobility, functional balance and increased health-related quality
of life. As it seems that balance, and not only pain relief, influences
the success of TKR, balance skills should be better addressed during
the post-operative rehabilitation of patients who undergo TKR.
Limited access surgery is thought to reduce post-operative morbidity and provide faster recovery of function. The percutaneous compression plate (PCCP) is a recently introduced device for the fixation of intertrochanteric fractures with minimal exposure. It has several potential mechanical advantages over the conventional compression hip screw (CHS). Our aim in this prospective, randomised, controlled study was to compare the outcome of patients operated on using these two devices. We randomised 104 patients with intertrochanteric fractures (AO/OTA 31.A1–A2) to surgical treatment with either the PCCP or CHS and followed them for one year postoperatively. The mean operating blood loss was 161.0 ml (8 to 450) in the PCCP group and 374.0 ml (11 to 980) in the CHS group (Student’s The PCCP device was associated with reduced intra-operative blood loss, less postoperative pain and a reduced incidence of collapse of the fracture.