Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Applied filters
The Bone & Joint Journal

Include Proceedings
Dates
Year From

Year To
The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 452 - 456
1 May 1992
Maistrelli G Mahomed N Garbuz D Fornasier V Harrington I Binnington A

In 33 dogs we implanted femoral stems made either of carbon composite, some coated with hydroxyapatite, or of titanium alloy with a porous coating. Osseointegration was greater in the hydroxyapatite-coated than in the un-coated stems (p less than 0.001). Push-out tests, at an average of 7.2 months after implantation, showed a six-fold increase in interface shear strength and a twelve-fold increase in shear stiffness in the hydroxyapatite-coated group compared with noncoated implants. The highest shear-strength values were found in the porous-coated titanium alloy stems, around which there was also the most resorptive bone remodelling.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 43 - 46
1 Jan 1991
Maistrelli G Fornasier V Binnington A McKenzie K Sessa V Harrington I

The purpose of this study was to determine the biological effects of the elastic modulus of the femoral stem in canine hip arthroplasty. Cementless total hip arthroplasty was performed in 12 dogs, six had a low elastic modulus polyacetal resin stem and six had a high modulus stainless steel stem. The components were otherwise similar. At six and 12 months after operation, radiographic and histomorphometric analysis showed that those with steel implants had more cortical porosity than did the other group (p less than 0.01). We suggest that the elastic modulus of the implant is an important factor in controlling cortical bone resorption. A low modulus femoral prosthesis can significantly decrease bone resorption which might otherwise eventually lead to implant failure.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 653 - 657
1 Jul 1990
Maistrelli G Gerundini M Fusco U Bombelli R Bombelli M Avai A

We reviewed the results of 277 intertrochanteric valgus-extension osteotomies performed between 1973 and 1975 for primary or secondary osteoarthritis. The average age of the patients was 51 years and follow-up varied from 11 to 15 years. At the latest evaluation 67% of the hips were good or excellent on the Merle D'Aubigne scale. Better results were obtained in patients under 40 years of age with unilateral involvement and a mechanical (secondary) aetiology. An elliptical femoral head, minimal subluxation and an adequate pre-operative range of motion were also favourable. There was radiographic evidence of regression of the arthritic changes in 39% of the hips at final review. Valgus-extension osteotomy is effective for secondary osteoarthritis of the hip in selected younger patients, but not for those with primary hip disease or a poor range of movement.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 761 - 766
1 Nov 1988
Maistrelli G Fusco U Avai A Bombelli R

We have reviewed the results of 106 intertrochanteric osteotomies performed for osteonecrosis of the femoral head. The average age at operation was 47.5 years. At two years from operation 71% of the hips had a clinically satisfactory result and at final follow-up, an average of 8.2 years after operation, 58% continued to have excellent or good rating. Twenty-four hips had needed total replacement or arthrodesis because of pain. Patients aged less than 55 did better than those operated on after that age, and hips with an idiopathic or post-traumatic aetiology did considerably better than alcohol-induced or steroid-induced cases. In view of these findings we believe that in the younger adult, in the absence of metabolic bone disease or advanced joint destruction, intertrochanteric osteotomy should be considered for the treatment of osteonecrosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 385 - 389
1 May 1985
Vaughan P Lui S Harrington I Maistrelli G

The Roger Anderson external fixator was used in the treatment of unstable fractures of the distal radius in 52 patients, and the results evaluated after a follow-up averaging 58 months. The indications for its use were failure to maintain adequate closed reduction using plaster, and instability of the fracture as determined by the initial radiographs. Our radiological criteria for instability included dorsal angulation of more than 20 degrees, fractures involving the joint, radial shortening of more than 10 mm, and severe dorsal comminution. Using the Lucas modification of the Sarmiento demerit point-rating system, we found that 46 patients (89%) had good or excellent results and six (11%) were classified as fair. There were no poor results. Seven patients (14%) developed complications. None of these affected the long-term results except in one elderly woman where the pins loosened and had to be removed.