The aim of this study was to compare the cost-effectiveness of surgical fixation with Kirschner (K-)wire ersus moulded casting after manipulation of a fracture of the distal radius in an operating theatre setting. An economic evaluation was conducted based on data collected from the Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT2) multicentre randomized controlled trial in the UK. Resource use was collected at three, six, and 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from an NHS and personal social services perspective. Sensitivity analyses were conducted to examine the robustness of cost-effectiveness estimates, and decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves.Aims
Methods
The aims of this study were to increase the diagnostic accuracy
of the analysis of synovial fluid in the differentiation of prosthetic
joint infection (PJI) by the addition of inexpensive biomarkers
such as the levels of C-reactive protein (CRP), adenosine deaminase
(ADA), alpha-2-macrogloblulin (α2M) and procalcitonin. Between January 2013 and December 2015, synovial fluid and removed
implants were requested from 143 revision total joint arthroplasties.
A total of 55 patients met inclusion criteria of the receipt of
sufficient synovial fluid, tissue samples and removed implants for
analysis. The diagnosis of PJI followed the definition from a recent International
Consensus Meeting to create two groups of patients; septic and aseptic.
Using receiver operating characteristic curves we determined the
cutoff values and diagnostic accuracy for each marker.Aims
Patients and Methods
The degree of displacement of a fracture of the distal radius
is an important factor which can be assessed using simple radiographic
measurements. Our aim was to investigate the reliability and reproducibility
of these measurements and to determine if they should be used clinically. A 10% sample was randomly generated from 3670 consecutive adult
patients who had presented to University Hospitals of Leicester
NHS Trust between 2007 and 2010 with a fracture of the distal radius.
Radiographs of the 367 patients were assessed by two independent
reviewers. Four measurements of displacement of the fracture were recorded
and the inter-observer correlation assessed using the intra-class
correlation coefficient.Aims
Patients and Methods
The use of journal clubs and, more recently,
case-based discussions in order to stimulate debate among orthopaedic
surgeons lies at the heart of orthopaedic training and education. A
virtual learning environment can be used as a platform to host virtual
journal clubs and case-based discussions. This has many advantages
in the current climate of constrained time and diminishing trainee
and consultant participation in such activities. The virtual environment
model opens up participation and improves access to journal clubs
and case-based discussions, provides reusable educational content,
establishes an electronic record of participation for individuals,
makes use of multimedia material (including clinical imaging and
photographs) for discussion, and finally, allows participants to
link case-based discussions with relevant papers in the journal
club. The Leicester experience highlights the many advantages and some
of the potential difficulties in setting up such a virtual system
and provides useful guidance for those considering such a system
in their own training programme. As a result of the virtual learning
environment, trainee participation has increased and there is a
trend for increased consultant input in the virtual journal club
and case-based discussions. It is likely that the use of virtual environments will expand
to encompass newer technological approaches to personal learning
and professional development.
We carried out lacerations of 50%, followed by trimming, in ten turkey flexor tendons We concluded that trimming partially lacerated flexor tendons will reduce the gliding resistance at the tendon-pulley interface, but will lead to fragmentation and triggering of the tendon at higher degrees of flexion and loading. We recommend that higher degrees of flexion be avoided during early post-operative rehabilitation following trimming of a flexor tendon.
Ultrasound scans were made of the hips of 209 neonates born consecutively over a two-week period. Of the 418 scans, 62 images were selected at random and 25 of these were duplicated to give a total of 87 scans. These static images were then presented to five experienced observers who each made nine different assessments and measurements. Interobserver and intraboserver agreement was calculated and expressed as kappa values. Our results showed poor reliability on both counts.
Fracture of the tuberosity of the scaphoid is common and usually heals without incident because of the good blood supply. We report four cases of nonunion of this fracture. Three of them were symptomatic and two required operative treatment.
Immobilisation of the thumb is widely believed to be important in the management of fractures of the carpal scaphoid. To assess the need for this, we randomly allocated 392 fresh fractures for treatment by either a forearm gauntlet (Colles') cast, leaving the thumb free, or by a conventional 'scaphoid' plaster incorporating the thumb as far as its interphalangeal joint. In the 292 fractures which were followed for six months, the incidence of nonunion was independent of the type of cast used.
Twenty observers reported independently on the presence or absence of a fracture of the scaphoid on 60 sets of radiographs; these included initial and 2- to 3-week views in patients in whom the outcome was known, normal scaphoids and random copies of these. Analysis of variance of the accuracy of observations revealed that the 2- to 3-week radiographs did not improve diagnostic ability and that this was independent of the experience or seniority of the observer. For normal radiographs, 20% of the observations reported a fracture. Reproducibility of opinion improved with experience but this did not help with accuracy. Radiographs without accurate clinical observation should not determine the management of the suspected scaphoid fracture.
Eighty-two of 85 patients who had sustained a fracture of the waist of the scaphoid in 1985 were reviewed more than one year after injury. The incidence of nonunion, defined as a clear gap at the fracture site one year after injury, was 12.3%. This was much higher than expected. Most of the patients with nonunion had symptoms and had appreciable restriction of wrist movement. In a further 25% of the patients at review, the site of the fracture could be easily identified although it appeared to have healed. These patients were older and more of them were women. Three-quarters of these patients had symptoms but their wrist movement was essentially normal.
We have studied the role of computerised axial tomography in the assessment of the acetabulum before an uncemented Mittelmeier arthroplasty was performed in 20 patients. In the absence of gross anatomical abnormality, computerised tomography did not provide additional information, but in eight patients it was useful in determining adequacy of acetabular depth, anterior acetabular cover, and thickness of the anterior and posterior walls. In these patients, the CT scans provided information which was not available from plain radiographs and greatly assisted in pre-operative planning.
In 15 consecutive patients with slipped capital femoral epiphysis we recorded height, weight and skeletal maturity. Sexual maturity was assessed clinically and biochemically, and Harris's hypothesis that there is an increased ratio of serum growth hormone to oestrogen was tested in comparison with 15 age and sex matched controls. We found no difference in skeletal or sexual maturity between the groups, or any overt endocrine abnormality in the patients. However almost half the patients with slipped epiphysis were over the 90th weight percentile, suggesting that mechanical factors such as obesity are more important aetiologically than endocrine abnormalities.
We report a case of neonatal separation of the distal humeral epiphysis in which non-invasive ultrasonic examination provided clear definition of the injury.
Inter-observer agreement and reproducibility of opinion were assessed for the radiographic diagnosis of union of scaphoid fractures on films taken 12 weeks after injury. Weighted kappa statistics were used to compare the opinions of eight senior observers reviewing 20 sets of good quality radiographs on two occasions separated by two months. There was poor agreement on whether trabeculae crossed the fracture line, whether there was sclerosis at or near the fracture and on whether the proximal part of the scaphoid was avascular. As a consequence, agreement on union also was poor; it appears that radiographs taken 12 weeks after a scaphoid fracture do not provide reliable and reproducible evidence of healing.
The treatment of acromioclavicular injuries is controversial; few studies document the late results. We have reviewed 53 patients about five years after conservative management, in nine for subluxation and 44 for dislocation. Subjective and objective results were satisfactory in all cases except for one with painful subluxation, who was the only patient to change her occupation because of the injury. At review, joint stability was demonstrated by improvement in position and by the very small increase in the coracoclavicular gap on stress radiographs.
Unilateral Colles' fractures in 187 patients over the age of 55 years were studied in a randomised prospective trial: 97 fractures were minimally displaced and were treated either conventionally or in a crepe bandage; 90 displaced Colles' fractures were reduced and of these 47 were treated conventionally while 43 were encouraged to mobilise the wrist in a cast which restricted extension. Early wrist movement hastened functional recovery and led to earlier resolution of wrist swelling. Discomfort was no greater than in patients who were treated conventionally. The bony deformity, which recurred irrespective of the method of treatment, was not adversely affected by early mobilisation.
Sixteen consecutive patients with tibial plateau fractures were investigated by standard radiography, biplanar tomography and computerised axial tomograms (CT scans). It was found that CT scanning proved most helpful for classifying the type of fracture, for evaluating the degree of comminution, and for measuring displacement. Moreover, because a single position was maintained throughout the investigation, the patients felt less discomfort than during other assessment procedures. For these reasons CT scanning is recommended for evaluating this type of fracture.