Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Applied filters
The Bone & Joint Journal

Include Proceedings
Dates
Year From

Year To
The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 620 - 620
1 May 2002
ROBERTS C DELISS L


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 458 - 459
1 Aug 1982
Deliss L Wilson J

A previously undescribed syndrome affecting the fingers of women is presented. The patients experience a sharp pain and then the fingers become blue and numb. The discoloration resolves within 72 hours without the changes normally associated with an ecchymosis. Clinical and haematological examination of six patients failed to show any common factors or associated systemic disease. This syndrome is of no clinical significance to the patient, but it is important for clinicians to be aware of it because the acute phase can cause anxiety, suggesting more serious vascular disease.


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 4 | Pages 516 - 519
1 Nov 1978
Browett J Gibbs A Copeland S Deliss L

A prospective trial has been carried out to determine the value of suction drainage in the operation of meniscectomy. One hundred operations were analysed, in half of which drains had been used. The use of the drain could not be shown to result in any sustained advantages. The demand for analgesics after the operation was reduced but not to a statistically significant level. The size of the early effusion was significantly reduced, but this benefit was lost when the knee was mobilised. The return of power to the quadriceps and of movement to the knee were not hastened. The average volume of fluid drained was 134 millilitres and it has been shown that forty-eight hours is a suitable time for removal of the drain. The use of suction drainage is not advocated for the uncomplicated operation of meniscectomy.


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 327 - 332
1 Aug 1978
Lettin A Deliss L Blackburne J Scales J

The Stanmore hinged total knee replacement was introduced in 1969 for severe destructive arthropathy of the knee, and the results of one hundred consecutive operations are presented after an average interval of two and a half years. Insertion of the prosthesis relieved pain in 94 per cent, improved the range of movement in 67 per cent, invariably restored stability and corrected valgus or varus deformity. Gross flexion contractures were improved but not always fully corrected. Serious complications were few, though of three cases of deep infection two came to amputation and one to fibrous ankylosis. There were no mechanical failures of components of the prosthesis.