Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
The Bone & Joint Journal

Include Proceedings
Dates
Year From

Year To
The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1005 - 1015
1 Aug 2014
Alshryda S Sukeik M Sarda P Blenkinsopp J Haddad FS Mason JM

Intravenous tranexamic acid (TXA) has been shown to be effective in reducing blood loss and the need for transfusion after joint replacement. Recently, there has been interest in applying it topically before the closure of surgical wounds. This has the advantages of ease of application, maximum concentration at the site of bleeding, minimising its systemic absorption and, consequently, concerns about possible side-effects.

We conducted a systematic review and meta-analysis which included 14 randomised controlled trials (11 in knee replacement, two in hip replacement and one in both) which investigated the effect of topical TXA on blood loss and rates of transfusion. Topical TXA significantly reduced the rate of blood transfusion (total knee replacement: risk ratio (RR) 4.51; 95% confidence interval (CI): 3.02 to 6.72; p < 0.001 (nine trials, I2 = 0%); total hip replacement: RR 2.56; 95% CI: 1.32 to 4.97, p = 0.004 (one trial)). The rate of thromboembolic events with topical TXA were similar to those found with a placebo. Indirect comparison of placebo-controlled trials of topical and intravenous TXA indicates that topical administration is superior to the intravenous route.

In conclusion, topical TXA is an effective and safe method of reducing the need for blood transfusion after total knee and hip replacement. Further research is required to find its optimum dose for topical use.

Cite this article: Bone Joint J 2014;96-B:1005–15.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1577 - 1585
1 Dec 2011
Alshryda S Sarda P Sukeik M Nargol A Blenkinsopp J Mason JM

We conducted a systematic review and meta-analysis of randomised controlled trials evaluating the effect of tranexamic acid (TXA) upon blood loss and transfusion in primary total knee replacement. The review used the generic evaluation tool designed by the Cochrane Bone, Joint and Muscle Trauma Group. A total of 19 trials were eligible: 18 used intravenous administration, one also evaluated oral dosing and one trial evaluated topical use. TXA led to a significant reduction in the proportion of patients requiring blood transfusion (risk ratio (RR) 2.56, 95% confidence interval (CI) 2.1 to 3.1, p < 0.001; heterogeneity I2 = 75%; 14 trials, 824 patients). Using TXA also reduced total blood loss by a mean of 591 ml (95% CI 536 to 647, p < 0.001; I2 = 78%; nine trials, 763 patients). The clinical interpretation of these findings is limited by substantial heterogeneity. However, subgroup analysis of high-dose (> 4 g) TXA showed a plausible consistent reduction in blood transfusion requirements (RR 5.33; 95% CI 2.44 to 11.65, p < 0.001; I2 = 0%), a finding that should be confirmed by a further well-designed trial. The current evidence from trials does not support an increased risk of deep-vein thrombosis (13 trials, 801 patients) or pulmonary embolism (18 trials, 971 patients) due to TXA administration.