Vol. 100-B, Issue 5 | Pages 667 - 674
1 May 2018
Lauthe O Soubeyrand M Babinet A Dumaine V Anract P Biau DJ

Aims

The primary aim of this study was to determine the morbidity of a tibial strut autograft and characterize the rate of bony union following its use.

Patients and Methods

We retrospectively assessed a series of 104 patients from a single centre who were treated with a tibial strut autograft of > 5 cm in length. A total of 30 had a segmental reconstruction with continuity of bone, 27 had a segmental reconstruction without continuity of bone, 29 had an arthrodesis and 18 had a nonunion. Donor-site morbidity was defined as any event that required a modification of the postoperative management. Union was assessed clinically and radiologically at a median of 36 months (IQR, 14 to 74).


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1244 - 1249
1 Sep 2017
Cladière-Nassif V Bourdet C Audard V Babinet A Anract P Biau D

Aims

Resection of the proximal humerus for the primary malignant bone tumour sometimes requires en bloc resection of the deltoid. However, there is no information in the literature which helps a surgeon decide whether to preserve the deltoid or not. The aim of this study was to determine whether retaining the deltoid at the time of resection would increase the rate of local recurrence. We also sought to identify the variables that persuade expert surgeons to choose a deltoid sparing rather than deltoid resecting procedure.

Patients and Methods

We reviewed 45 patients who had undergone resection of a primary malignant tumour of the proximal humerus. There were 29 in the deltoid sparing group and 16 in the deltoid resecting group. Imaging studies were reviewed to assess tumour extension and soft-tissue involvement. The presence of a fat rim separating the tumour from the deltoid on MRI was particularly noted. The cumulative probability of local recurrence was calculated in a competing risk scenario.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1183 - 1188
1 Sep 2011
Biau DJ Meziane M Bhumbra RS Dumaine V Babinet A Anract P

The purpose of this study was to define immediate post-operative ‘quality’ in total hip replacements and to study prospectively the occurrence of failure based on these definitions of quality. The evaluation and assessment of failure were based on ten radiological and clinical criteria. The cumulative summation (CUSUM) test was used to study 200 procedures over a one-year period. Technical criteria defined failure in 17 cases (8.5%), those related to the femoral component in nine (4.5%), the acetabular component in 32 (16%) and those relating to discharge from hospital in five (2.5%). Overall, the procedure was considered to have failed in 57 of the 200 total hip replacements (28.5%). The use of a new design of acetabular component was associated with more failures. For the CUSUM test, the level of adequate performance was set at a rate of failure of 20% and the level of inadequate performance set at a failure rate of 40%; no alarm was raised by the test, indicating that there was no evidence of inadequate performance.

The use of a continuous monitoring statistical method is useful to ensure that the quality of total hip replacement is maintained, especially as newer implants are introduced.