Advertisement for orthosearch.org.uk
Results 1 - 20 of 3420
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 688 - 695
1 Jul 2024
Farrow L Zhong M Anderson L

Aims. To examine whether natural language processing (NLP) using a clinically based large language model (LLM) could be used to predict patient selection for total hip or total knee arthroplasty (THA/TKA) from routinely available free-text radiology reports. Methods. Data pre-processing and analyses were conducted according to the Artificial intelligence to Revolutionize the patient Care pathway in Hip and knEe aRthroplastY (ARCHERY) project protocol. This included use of de-identified Scottish regional clinical data of patients referred for consideration of THA/TKA, held in a secure data environment designed for artificial intelligence (AI) inference. Only preoperative radiology reports were included. NLP algorithms were based on the freely available GatorTron model, a LLM trained on over 82 billion words of de-identified clinical text. Two inference tasks were performed: assessment after model-fine tuning (50 Epochs and three cycles of k-fold cross validation), and external validation. Results. For THA, there were 5,558 patient radiology reports included, of which 4,137 were used for model training and testing, and 1,421 for external validation. Following training, model performance demonstrated average (mean across three folds) accuracy, F1 score, and area under the receiver operating curve (AUROC) values of 0.850 (95% confidence interval (CI) 0.833 to 0.867), 0.813 (95% CI 0.785 to 0.841), and 0.847 (95% CI 0.822 to 0.872), respectively. For TKA, 7,457 patient radiology reports were included, with 3,478 used for model training and testing, and 3,152 for external validation. Performance metrics included accuracy, F1 score, and AUROC values of 0.757 (95% CI 0.702 to 0.811), 0.543 (95% CI 0.479 to 0.607), and 0.717 (95% CI 0.657 to 0.778) respectively. There was a notable deterioration in performance on external validation in both cohorts. Conclusion. The use of routinely available preoperative radiology reports provides promising potential to help screen suitable candidates for THA, but not for TKA. The external validation results demonstrate the importance of further model testing and training when confronted with new clinical cohorts. Cite this article: Bone Joint J 2024;106-B(7):688–695


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 359 - 364
1 Apr 2024
Özdemir E de Lange B Buckens CFM Rijnen WHC Visser J

Aims. To investigate the extent of bone development around the scaffold of custom triflange acetabular components (CTACs) over time. Methods. We performed a single-centre historical prospective cohort study, including all patients with revision THA using the aMace CTAC between January 2017 and March 2021. A total of 18 patients (18 CTACs) were included. Models of the hemipelvis and the scaffold component of the CTACs were created by segmentation of CT scans. The CT scans were performed immediately postoperatively and at least one year after surgery. The amount of bone in contact with the scaffold was analyzed at both times, and the difference was calculated. Results. The mean time between the implantation and the second CT scan was two years (1 to 5). The mean age of the patients during CTAC implantation was 75 years (60 to 92). The mean scaffold-bone contact area increased from 16% (SD 12.6) to 28% (SD 11.9). The mean scaffold-bone distance decreased from a mean of 6.5 mm (SD 2.0) to 5.5 mm (SD 1.6). None of the CTACs were revised or radiologically loose. Conclusion. There was a statistically significant increase of scaffold-bone contact area over time, but the total contact area of the scaffold in relation to the acetabular bone remained relatively low. As all implants remained well fixed, the question remains to what extend the scaffold contributes to the observed stability, in relation to the screws. A future design implication might be an elimination of the bulky scaffold component. This design modification would reduce production costs and may optimize the primary fit of the implant. Cite this article: Bone Joint J 2024;106-B(4):359–364


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims. The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes. Methods. This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group). Results. Perforation of the vault of the glenoid (p = 0.018) and size mismatch in height (p < 0.001) and width (p = 0.013) were significantly more frequent in the ST group than in the SM group. There was no significant difference in the clinical scores and ROM in the two groups, two years postoperatively (all p > 0.05). In subgroup analysis, the VP group had significantly less inferior overhang (p = 0.009), more scapular notching (p = 0.018), and more size mismatch in height (p < 0.001) and width (p = 0.025) than the VNP group. Conclusion. In Asian patients with a small glenoid, using a 29.5 mm small baseplate at the time of RSA was more effective in reducing size mismatch between the glenoid and the baseplate, decreasing the incidence of perforation of the glenoid vault, and achieving optimal positioning of the baseplate compared with the use of a 33.8 mm standard baseplate. However, longer follow-up is required to assess the impact of these findings on the clinical outcomes. Cite this article: Bone Joint J 2023;105-B(11):1189–1195


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1202 - 1208
1 Nov 2022
Klasan A Rice DA Kluger MT Borotkanics R McNair PJ Lewis GN Young SW

Aims. Despite new technologies for total knee arthroplasty (TKA), approximately 20% of patients are dissatisfied. A major reason for dissatisfaction and revision surgery after TKA is persistent pain. The radiological grade of osteoarthritis (OA) preoperatively has been investigated as a predictor of the outcome after TKA, with conflicting results. The aim of this study was to determine if there is a difference in the intensity of pain 12 months after TKA in relation to the preoperative radiological grade of OA alone, and the combination of the intensity of preoperative pain and radiological grade of OA. Methods. The preoperative data of 300 patients who underwent primary TKA were collected, including clinical information (age, sex, preoperative pain), psychological variables (depression, anxiety, pain catastrophizing, anticipated pain), and quantitative sensory testing (temporal summation, pressure pain thresholds, conditioned pain modulation). The preoperative radiological severity of OA was graded according to the Kellgren-Lawrence (KL) classification. Persistent pain in the knee was recorded 12 months postoperatively. Generalized linear models explored differences in postoperative pain according to the KL grade, and combined preoperative pain and KL grade. Relative risk models explored which preoperative variables were associated with the high preoperative pain/low KL grade group. Results. Pain 12 months after TKA was not associated with the preoperative KL grade alone. Significantly increased pain 12 months after TKA was found in patients with a combination of high preoperative pain and a low KL grade (p = 0.012). Patients in this group were significantly more likely to be male, younger, and have higher preoperative pain catastrophizing, higher depression, and lower anxiety (all p ≤ 0.05). Conclusion. Combined high preoperative pain and low radiological grade of OA, but not the radiological grade alone, was associated with a higher intensity of pain 12 months after primary TKA. This group may have a more complex cause of pain that requires additional psychological interventions in order to optimize the outcome of TKA. Cite this article: Bone Joint J 2022;104-B(11):1202–1208


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 668 - 678
1 Jun 2023
Friedman RJ Boettcher ML Grey S Flurin P Wright TW Zuckerman JD Eichinger JK Roche C

Aims. The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system. Methods. We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217). Results. Relative to their preoperative condition, each glenoid cohort had significant improvements in clinical outcomes from two years to ten years after surgery. Patients with cage glenoids had significantly better clinical outcomes, with higher patient-reported outcome scores and significantly increased active range of motion, compared with those with keel and peg glenoids. Those with cage glenoids also had significantly fewer complications (keel: 13.3%, peg: 13.1%, cage: 7.4%), revisions (keel: 7.1%, peg 9.7%, cage 3.5%), and aseptic glenoid loosening and failure (keel: 4.7%, peg: 5.8%, cage: 2.5%). Regarding radiological outcomes, 70 patients (11.2%) with cage glenoids had glenoid radiolucent lines (RLLs). The cage glenoid RLL rate was 3.3-times (p < 0.001) less than those with keel glenoids (37.3%) and 4.6-times (p < 0.001) less than those with peg glenoids (51.2%). Conclusion. These findings show that good long-term clinical and radiological outcomes can be achieved with each of the three aTSA designs of glenoid component analyzed in this study. However, there were some differences in clinical and radiological outcomes: generally, cage glenoids performed best, followed by cemented keel glenoids, and finally cemented peg glenoids. Cite this article: Bone Joint J 2023;105-B(6):668–678


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims. This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA). Methods. From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery. Results. There were no significant differences in demographic data and preoperative characteristics between the two groups. Both groups showed significant improvements in patient-reported outcome measures (visual analogue scale for pain, visual analogue scale for function, American Shoulder and Elbow Surgeons, Constant, and Simple Shoulder Test scores) from preoperative to final assessment (p < 0.001). However, AGB showed no additional benefit. Notably, within range of motion, Group B showed significant postoperative decrease in both external rotation and internal rotation, unlike Group A (p = 0.028 and 0.003, respectively). Both groups demonstrated a significant correction of superior-inclination after surgery, while patients in Group B exhibited a significant decrease in LHO postoperatively (p = 0.001). Regarding complications, Group A experienced more acromial stress fractures (3 cases; 12.5%), whereas Group B had a higher occurrence of scapular notching (24 cases; 33.3%) (p = 0.008). Conclusion. Both eccentric reaming with STB and off-axis reaming with AGB are effective methods for addressing superior glenoid wear in RSA, leading to improved clinical outcomes. However, it is important to be aware of the potential risks associated with eccentric reaming, which include excessive bone loss leading to reduced rotation and scapular notching. Cite this article: Bone Joint J 2024;106-B(3):268–276


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 88 - 96
1 Jan 2023
Vogt B Rupp C Gosheger G Eveslage M Laufer A Toporowski G Roedl R Frommer A

Aims. Distraction osteogenesis with intramedullary lengthening devices has undergone rapid development in the past decade with implant enhancement. In this first single-centre matched-pair analysis we focus on the comparison of treatment with the PRECICE and STRYDE intramedullary lengthening devices and aim to clarify any clinical and radiological differences. Methods. A single-centre 2:1 matched-pair retrospective analysis of 42 patients treated with the STRYDE and 82 patients treated with the PRECICE nail between May 2013 and November 2020 was conducted. Clinical and lengthening parameters were compared while focusing radiological assessment on osseous alterations related to the nail’s telescopic junction and locking bolts at four different stages. Results. Osteolysis next to the telescopic junction was observed in 31/48 segments (65%) lengthened with the STRYDE nail before implant removal compared to 1/91 segment (1%) in the PRECICE cohort. In the STRYDE cohort, osteolysis initially increased, but decreased or resolved in almost all lengthened segments (86%) after implant removal. Implant failure was observed in 9/48 STRYDE (19%) and in 8/92 PRECICE nails (9%). Breakage of the distal locking bolts was found in 5/48 STRYDE nails (10%) compared to none in the PRECICE cohort. Treatment-associated pain was generally recorded as mild and found in 30/48 patients (63%) and 39/92 (42%) in the STRYDE and PRECICE cohorts, respectively. Temporary range of motion (ROM) limitations under distraction were registered in 17/48 (35%) segments treated with the STRYDE and 35/92 segments (38%) treated with the PRECICE nail. Conclusion. Osteolysis and periosteal reaction, implant breakage, and pain during lengthening and consolidation is more likely in patients treated with the STRYDE nail compared to the PRECICE nail. Temporary ROM limitations during lengthening occurred independent of the applied device. Implant-related osseous alterations seem to remodel after implant removal. Cite this article: Bone Joint J 2023;105-B(1):88–96


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 87 - 97
1 Jan 2021
Burssens A De Roos D Barg A Welck MJ Krähenbühl N Saltzman CL Victor J

Aims. Patients with a deformity of the hindfoot present a particular challenge when performing total knee arthroplasty (TKA). The literature contains little information about the relationship between TKA and hindfoot alignment. This systematic review aimed to determine from both clinical and radiological studies whether TKA would alter a preoperative hindfoot deformity and whether the outcome of TKA is affected by the presence of a postoperative hindfoot deformity. Methods. A systematic literature search was performed in the databases PubMed, EMBASE, Cochrane Library, and Web of Science. Search terms consisted of “total knee arthroplasty/replacement” combined with “hindfoot/ankle alignment”. Inclusion criteria were all English language studies analyzing the association between TKA and the alignment of the hindfoot, including the clinical or radiological outcomes. Exclusion criteria consisted of TKA performed with a concomitant extra-articular osteotomy and case reports or expert opinions. An assessment of quality was conducted using the modified Methodological Index for Non-Randomized Studies (MINORS). The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines and registered in the PROSPERO database (CRD42019106980). Results. A total of 17 studies were found to be eligible for review. They included six prospective and ten retrospective studies, and one case-control study. The effects of TKA showed a clinical improvement in the hindfoot deformity in three studies, but did not if there was osteoarthritis (OA) of the ankle (one study) or a persistent deformity of the knee (one study). The radiological alignment of the hindfoot corrected in 11 studies, but did not in the presence of a rigid hindfoot varus deformity (in two studies). The effects of a hindfoot deformity on TKA included a clinical association with instability of the knee in one study, and a shift in the radiological weightbearing axis in two studies. The mean MINORS score was 9.4 out of 16 (7 to 12). Conclusion. TKA improves both the function and alignment of the hindfoot in patients with a preoperative deformity of the hindfoot. This may not apply if there is a persistent deformity of the knee, a rigid hindfoot varus deformity, or OA of the ankle. Moreover, a persistent deformity of the hindfoot may adversely affect the stability and longevity of a TKA. These findings should be interpreted with caution due to the moderate methodological quality of the studies which were included. Therefore, further prospective studies are needed in order to determine at which stage correction of a hindfoot deformity is required to optimize the outcome of a TKA. Cite this article: Bone Joint J 2021;103-B(1):87–97


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 40 - 46
1 May 2024
Massè A Giachino M Audisio A Donis A Giai Via R Secco DC Limone B Turchetto L Aprato A

Aims. Ganz’s studies made it possible to address joint deformities on both the femoral and acetabular side brought about by Perthes’ disease. Femoral head reduction osteotomy (FHRO) was developed to improve joint congruency, along with periacetabular osteotomy (PAO), which may enhance coverage and containment. The purpose of this study is to show the clinical and morphological outcomes of the technique and the use of an implemented planning approach. Methods. From September 2015 to December 2021, 13 FHROs were performed on 11 patients for Perthes’ disease in two centres. Of these, 11 hips had an associated PAO. A specific CT- and MRI-based protocol for virtual simulation of the corrections was developed. Outcomes were assessed with radiological parameters (sphericity index, extrusion index, integrity of the Shenton’s line, lateral centre-edge angle (LCEA), Tönnis angle), and clinical parameters (range of motion, visual analogue scale (VAS) for pain, Merle d'Aubigné-Postel score, modified Harris Hip Score (mHHS), and EuroQol five-dimension five-level health questionnaire (EQ-5D-5L)). Early and late complications were reported. Results. The mean follow-up was 39.7 months (standard deviation (SD) 26.4). The mean age at surgery was 11.4 years (SD 1.6). No major complications were recorded. One patient required a total hip arthroplasty. Mean femoral head sphericity increased from 46.8% (SD 9.34%) to 70.2% (SD 15.44; p < 0.001); mean LCEA from 19.2° (SD 9.03°) to 44° (SD 10.27°; p < 0.001); mean extrusion index from 37.8 (SD 8.70) to 7.5 (SD 9.28; p < 0.001); and mean Tönnis angle from 16.5° (SD 12.35°) to 4.8° (SD 4.05°; p = 0.100). The mean VAS improved from 3.55 (SD 3.05) to 1.22 (1.72; p = 0.06); mean Merle d’Aubigné-Postel score from 14.55 (SD 1.74) to 16 (SD 1.6; p = 0.01); and mean mHHS from 60.6 (SD 18.06) to 81 (SD 6.63; p = 0.021). The EQ-5D-5L also showed significant improvements. Conclusion. FHRO associated with periacetabular procedures is a safe technique that showed improved functional, clinical, and morphological outcomes in Perthes’ disease. The newly introduced simulation and planning algorithm may help to further refine the technique. Cite this article: Bone Joint J 2024;106-B(5 Supple B):40–46


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1815 - 1820
1 Dec 2021
Huhnstock S Wiig O Merckoll E Svenningsen S Terjesen T

Aims. The aim of this study was to assess the prognostic value of the modified three-group Stulberg classification, which is based on the sphericity of the femoral head, in patients with Perthes’ disease. Methods. A total of 88 patients were followed from the time of diagnosis until a mean follow-up of 21 years. Anteroposterior pelvic and frog-leg lateral radiographs were obtained at diagnosis and at follow-up of one, five, and 21 years. At the five- and 21-year follow-up, the femoral heads were classified using a modified three-group Stulberg classification (round, ovoid, or flat femoral head). Further radiological endpoints at long-term follow-up were osteoarthritis (OA) of the hip and the requirement for total hip arthroplasty (THA). Results. There were 71 males (81%) and 17 females. A total of 13 patients had bilateral Perthes’ disease; thus 101 hips were analyzed. At five-year follow-up, 37 hips were round, 38 ovoid, and 26 flat. At that time, 66 hips (65%) were healed and 91 (90%) were skeletally immature. At long-term follow-up, when the mean age of the patients was 28 years (24 to 34), 20 hips had an unsatisfactory outcome (seven had OA and 13 had required THA). There was a strongly significant association between the modified Stulberg classification applied atfive-year follow-up and an unsatisfactory outcome at long-term follow-up (p < 0.001). Between the five- and 21-year follow-up, 67 hips (76%) stayed in their respective modified Stulberg group, indicating a strongly significant association between the Stulberg classifications at these follow-ups (p < 0.001). Conclusion. The modified Stulberg classification is a strong predictor of long-term radiological outcome in patients with Perthes’ disease. It can be applied at the healing stage, which is usually reached five years after the diagnosis is made and before skeletal maturity. Cite this article: Bone Joint J 2021;103-B(12):1815–1820


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1309 - 1316
1 Jul 2021
Garg B Bansal T Mehta N

Aims. To describe the clinical, radiological, and functional outcomes in patients with isolated congenital thoracolumbar kyphosis who were treated with three-column osteotomy by posterior-only approach. Methods. Hospital records of 27 patients with isolated congenital thoracolumbar kyphosis undergoing surgery at a single centre were retrospectively analyzed. All patients underwent deformity correction which involved a three-column osteotomy by single-stage posterior-only approach. Radiological parameters (local kyphosis angle (KA), thoracic kyphosis (TK), lumbar lordosis (LL), pelvic tilt (PT), sacral slope (SS), C7 sagittal vertical axis (C7 SVA), T1 slope, and pelvic incidence minus lumbar lordosis (PI-LL)), functional scores, and clinical details of complications were recorded. Results. The mean age of the study population was 13.9 years (SD 6.4). The apex of deformity was in thoracic, thoracolumbar, and lumbar spine in five, 14, and eight patients, respectively. The mean operating time was 178.4 minutes (SD 38.5) and the mean operative blood loss was 701.8 ml (SD 194.4). KA (preoperative mean 70.8° (SD 21.6°) vs final follow-up mean 24.7° (SD 18.9°); p < 0.001) and TK (preoperative mean -1.48° (SD 41.23°) vs final follow-up mean 24.28° (SD 17.29°); p = 0.005) underwent a significant change with surgery. Mean Scoliosis Research Society (SRS-22r) score improved after surgical correction (preoperative mean 3.24 (SD 0.37) vs final follow-up mean 4.28 (SD 0.47); p < 0.001) with maximum improvement in self-image and mental health domains. The overall complication rate was 26%, including two neurological and five non-neurological complications. Permanent neurological deficit was noted in one patient. Conclusion. Deformity correction employing three-column osteotomies by a single-stage posterior-only approach is safe and effective in treating isolated congenital thoracolumbar kyphosis. Cite this article: Bone Joint J 2021;103-B(7):1309–1316


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1307 - 1312
1 Oct 2019
Jacxsens M Schmid J Zdravkovic V Jost B Spross C

Aims. In order to determine whether and for whom serial radiological evaluation is necessary in one-part proximal humerus fractures, we set out to describe the clinical history and predictors of secondary displacement in patients sustaining these injuries. Patients and Methods. Between January 2014 and April 2016, all patients with an isolated, nonoperatively treated one-part proximal humerus fracture were prospectively followed up. Clinical and radiological evaluation took place at less than two, six, 12, and 52 weeks. Fracture configuration, bone quality, and comminution were determined on the initial radiographs. Fracture healing, secondary displacement, and treatment changes were recorded during follow-up. Results. In 100 patients (59 female, 41 male; mean age 57 years), 91 of the fractures (91%) remained stable. In five of nine patients (55%) with secondary displacement, surgery was recommended. Comminution, present in 23 patients (23%), was identified as a predictor of secondary displacement (p < 0.001). Patients’ age, sex, fracture configuration, and bone quality were not associated with secondary displacement (p ≥ 0.438). Nonoperative treatment resulted in a mean absolute Constant score (CS) of 80 (49 to 98), relative CS of 101% (63% to 138%), median subjective shoulder value of 95% (interquartile range (IQR) 90% to 100%), and median EuroQol five-dimensional questionnaire score of 0.89 (IQR 0.80 to 1.00) with bone union in all cases at one-year follow-up. Conclusion. Radiological re-evaluation was only necessary in patients presenting with comminution and may be redundant for 77% of patients with one-part proximal humerus fractures. Nonoperative treatment of one-part proximal humerus fractures remains the mainstay of treatment with a low rate of secondary surgery, a high union rate, and good clinical results. Cite this article: Bone Joint J 2019;101-B:1307–1312


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 456 - 461
1 Mar 2021
Sasaki G Watanabe Y Yasui Y Nishizawa M Saka N Kawano H Miyamoto W

Aims. To clarify the effectiveness of the induced membrane technique (IMT) using beta-tricalcium phosphate (β-TCP) for reconstruction of segmental bone defects by evaluating clinical and radiological outcomes, and the effect of defect size and operated site on surgical outcomes. Methods. A review of the medical records was conducted of consecutive 35 lower limbs (30 males and five females; median age 46 years (interquartile range (IQR) 40 to 61)) treated with IMT using β-TCP between 2014 and 2018. Lower Extremity Functional Score (LEFS) was examined preoperatively and at final follow-up to clarify patient-centered outcomes. Bone healing was assessed radiologically, and time from the second stage to bone healing was also evaluated. Patients were divided into ≥ 50 mm and < 50 mm defect groups and into femoral reconstruction, tibial reconstruction, and ankle arthrodesis groups. Results. There were ten and 25 defects in the femur and tibia, respectively. Median LEFS improved significantly from 8 (IQR 1.5 to 19.3) preoperatively to 63.5 (IQR 57 to 73.3) at final follow-up (p < 0.001). Bone healing was achieved in all limbs, and median time from the second stage to bone healing was six months (IQR 5 to 10). Median time to bone healing, preoperative LEFS, or postoperative LEFS did not differ significantly between the defect size groups or among the treatment groups. Conclusion. IMT using β-TCP provided satisfactory clinical and radiological outcomes for segmental bone defects in the lower limbs; surgical outcomes were not influenced by bone defect size or operated part. Cite this article: Bone Joint J 2021;103-B(3):456–461


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 301 - 309
1 Mar 2020
Keenan OJF Holland G Maempel JF Keating JF Scott CEH

Aims. Although knee osteoarthritis (OA) is diagnosed and monitored radiologically, actual full-thickness cartilage loss (FTCL) has rarely been correlated with radiological classification. This study aims to analyze which classification system correlates best with FTCL and to assess their reliability. Methods. A prospective study of 300 consecutive patients undergoing unilateral total knee arthroplasty (TKA) for OA (mean age 69 years (44 to 91; standard deviation (SD) 9.5), 178 (59%) female). Two blinded examiners independently graded preoperative radiographs using five common systems: Kellgren-Lawrence (KL); International Knee Documentation Committee (IKDC); Fairbank; Brandt; and Ahlbäck. Interobserver agreement was assessed using the intraclass correlation coefficient (ICC). Intraoperatively, anterior cruciate ligament (ACL) status and the presence of FTCL in 16 regions of interest were recorded. Radiological classification and FTCL were correlated using the Spearman correlation coefficient. Results. Knees had a mean of 6.8 regions of FTCL (SD 3.1), most common medially. The commonest patterns of FTCL were medial ± patellofemoral (143/300, 48%) and tricompartmental (89/300, 30%). ACL status was associated with pattern of FTCL (p = 0.023). All radiological classification systems demonstrated moderate ICC, but this was highest for the IKDC: whole knee 0.68 (95% confidence interval (CI) 0.60 to 0.74); medial compartment 0.84 (95% CI 0.80 to 0.87); and lateral compartment 0.79 (95% CI 0.73 to 0.83). Correlation with actual FTCL was strongest for Ahlbäck (Spearman rho 0.27 to 0.39) and KL (0.30 to 0.33) systems, although all systems demonstrated medium correlation. The Ahlbäck score was the most discriminating in severe knee OA. Osteophyte presence in the medial compartment had high positive predictive value (PPV) for FTCL, but not in the lateral compartment. Conclusion. The Ahlbäck and KL systems had the highest correlation with confirmed cartilage loss at TKA. However, the IKDC system displayed the best interobserver reliability, with favourable correlation with FTCL in medial and lateral compartments, although it was less discriminating in more severe disease. Cite this article: Bone Joint J 2020;102-B(3):301–309


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 610 - 614
1 May 2019
Aibinder WR Bartels DW Sperling JW Sanchez-Sotelo J

Aims. Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA). Patients and Methods. A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m. 2. (17.3 to 66.4). Results. Greater tuberosity stress shielding was noted in 14 shoulders (two TSA and 12 RSA) and was graded as mild in nine, moderate in two, and severe in three. Medial calcar resorption was noted in 23 shoulders (seven TSA and 16 RSA), and was graded as mild in 21 and moderate in two. No humeral components were revised for loosening or considered to be loose radiologically. Nine shoulders underwent reoperation for infection (n = 3), fracture of the humeral tray (n = 2), aseptic glenoid loosening (n = 1), and instability (n = 3). No periprosthetic fractures occurred. Conclusion. Implantation of this particular short cementless humeral component at the time of TSA or RSA was associated with a low rate of adverse radiological findings on the humeral side at mid-term follow-up. Our data do not raise any concerns regarding the use of a short stem in TSA or RSA. Cite this article: Bone Joint J 2019;101-B:610–614


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 808 - 814
1 Jul 2023
Gundavda MK Lazarides AL Burke ZDC Focaccia M Griffin AM Tsoi KM Ferguson PC Wunder JS

Aims

The preoperative grading of chondrosarcomas of bone that accurately predicts surgical management is difficult for surgeons, radiologists, and pathologists. There are often discrepancies in grade between the initial biopsy and the final histology. Recent advances in the use of imaging methods have shown promise in the ability to predict the final grade. The most important clinical distinction is between grade 1 chondrosarcomas, which are amenable to curettage, and resection-grade chondrosarcomas (grade 2 and 3) which require en bloc resection. The aim of this study was to evaluate the use of a Radiological Aggressiveness Score (RAS) to predict the grade of primary chondrosarcomas in long bones and thus to guide management.

Methods

A total of 113 patients with a primary chondrosarcoma of a long bone presenting between January 2001 and December 2021 were identified on retrospective review of a single oncology centre’s prospectively collected database. The nine-parameter RAS included variables from radiographs and MRI scans. The best cut-off of parameters to predict the final grade of chondrosarcoma after resection was determined using a receiver operating characteristic curve (ROC), and this was correlated with the biopsy grade.


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 376 - 382
1 Mar 2017
Plant CE Parsons NR Costa ML

Aims. We conducted a study to determine whether radiological parameters correlate with patient reported functional outcome, health-related quality of life and physical measures of function in patients with a fracture of the distal radius. Patients and Methods. The post-operative palmar tilt and ulnar variance at six weeks and 12 months were correlated with the Patient Rated Wrist Evaluation, Disabilities of the Arm, Shoulder and Hand, and EuroQol scores, grip strength, pinch strength and range of movement at three, six and 12 months for 50 patients (mean age 57 years; 26 to 85) having surgical fixation, with either percutaneous pinning or reconstruction with a volar plate, for a fracture of the distal radius. Results. Radiological parameters were found to correlate poorly with the patient reported outcomes (r = 0.00 to 0.47) and physical measures of function (r = 0.01 to 0.51) at all intervals. Conclusion. This study raises concerns about the use of radiological parameters to determine management, and to act as a surrogates for successful treatment, in patients with a fracture of the distal radius. Restoration of ‘normal’ radiographic parameters may not be necessary to achieve a satisfactory functional outcome for the patient. Cite this article: Bone Joint J 2017;99-B:376–82


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 459 - 462
1 Apr 2009
Heinert G Hendricks J Loeffler MD

Digital templating in hip replacement is commonly performed with radiological markers to determine the magnification. The latter can also be determined by measuring the distance from the x-ray focal spot to the object and the distance from the x-ray focal spot to the radiological cassette or image receptor. We used post-operative radiographs of total hip replacements and hemiarthroplasties from 22 patients to calculate the magnification using both methods. The accuracy of each method was ascertained by measuring the size of the head of the implant projected on to the radiographs and comparing the result with the known size recorded in the medical records. The accuracy was found to be similar with a mean absolute measurement error of 2.6% (. sd. 1.4; 0.0% to 5.2%) for the radiological marker and 2.8% (. sd. 2.2; 0.4% to 10.1%) for the distance method (p = 0.75). The mean radiation dose for templating radiographs (pelvis and lateral of the hip) was similar when taken using a radiological marker (328 mSv . sd. 142) (n = 51) or using the distance measurement method (324 mSv . sd. 39) (n = 39) (p = 0.90). We conclude that the distance measuring method is as accurate as the radiological marker method, but may avoid some of the disadvantages such as misplacement of the marker or placement outside the radiological field. It may also be more acceptable to the patient and radiographer


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 483 - 489
1 Apr 2016
Tigchelaar S Rooy JD Hannink G Koëter S van Kampen A Bongers E

Aim. Nail patella syndrome (NPS) is a skeletal dysplasia with patellofemoral dysfunction as a key symptom. We present the first in-depth radiological evaluation of the knee in a large series of NPS patients and describe the typical malformations. Patients and Methods. Conventional radiological examination of 95 skeletally mature patients with NPS was performed. Patellar morphology was classified according to the Wiberg classification as modified by Baumgartl and Ficat criteria, and trochlear shape was classified according to the Dejour classification. Results. Patellar aplasia was present in 4/90 (4%), and patellar hypoplasia in 77/90 (86%) of patients. The prevailing patellar shapes were type III, type IV and Hunter’s cap. No patellar shape genotype-phenotype association could be found. The malformations of the distal femur comprised shortening of the lateral femoral condyle in 46 out of 84 patients (55%), with a prominent anterior surface of the lateral femoral condyle in 47 out of 84 patients (56%) and a flat anterior surface of the medial femoral condyle in 78 out of 85 patients (92%). The trochlea was type A1 according to the Dejour classification in 79 out of 85 patients (93%). . Conclusion. An easily recognisable characteristic quartet of malformations consisting of patellar aplasiaor hypoplasia and the malformations of the distal femur was found in 22 out of 81 patients (27%), with the majority displaying at least three malformations. Take home message: The distinct malformations of the knee in nail patella syndrome are easily recognisable on conventional radiographs and lead to the correct interpretation of the aberrant morphology which is essential in the treatment of these patellofemoral disorders. Cite this article: Bone Joint J 2016;98-B:483–9


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 950 - 956
1 Jul 2015
Tsitsilonis S Schaser KD Wichlas F Haas NP Manegold S

The incidence of periprosthetic fractures of the ankle is increasing. However, little is known about the outcome of treatment and their management remains controversial. The aim of this study was to assess the impact of periprosthetic fractures on the functional and radiological outcome of patients with a total ankle arthroplasty (TAA). A total of 505 TAAs (488 patients) who underwent TAA were retrospectively evaluated for periprosthetic ankle fracture: these were then classified according to a recent classification which is orientated towards treatment. The outcome was evaluated clinically using the American Orthopedic Foot and Ankle Society (AOFAS) score and a visual analogue scale for pain, and radiologically. . A total of 21 patients with a periprosthetic fracture of the ankle were identified. There were 13 women and eight men. The mean age of the patients was 63 years (48 to 74). Thus, the incidence of fracture was 4.17%. . There were 11 intra-operative and ten post-operative fractures, of which eight were stress fractures and two were traumatic. The prosthesis was stable in all patients. Five stress fractures were treated conservatively and the remaining three were treated operatively. . A total of 17 patients (81%) were examined clinically and radiologically at a mean follow-up of 53.5 months (12 to 112). The mean AOFAS score at follow-up was 79.5 (21 to 100). The mean AOFAS score in those with an intra-operative fracture was 87.6 (80 to 100) and for those with a stress fracture, which were mainly because of varus malpositioning, was 67.3 (21 to 93). Periprosthetic fractures of the ankle do not necessarily adversely affect the clinical outcome, provided that a treatment algorithm is implemented with the help of a new classification system. . Cite this article: Bone Joint J 2015;97-B:950–6