Advertisement for orthosearch.org.uk
Results 1 - 20 of 264
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 765 - 766
1 Jul 2022
Haddad FS Malchau H


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 469 - 476
1 Apr 2010
Shimmin AJ Walter WL Esposito C

The survivorship of contemporary resurfacing arthroplasty of the hip using metal-on-metal bearings is better than that of first generation designs, but short-term failures still occur. The most common reasons for failure are fracture of the femoral neck, loosening of the component, osteonecrosis of the femoral head, reaction to metal debris and malpositioning of the component. In 2008 the Australian National Joint Registry reported an inverse relationship between the size of the head component and the risk of revision in resurfacing hip arthroplasty. Hips with a femoral component size of ≤ 44 mm have a fivefold increased risk of revision than those with femoral components of ≥ 55 mm irrespective of gender. We have reviewed the literature to explore this observation and to identify possible reasons including the design of the implant, loading of the femoral neck, the orientation of the component, the production of wear debris and the effects of metal ions, penetration of cement and vascularity of the femoral head. Our conclusion is that although multifactorial, the most important contributors to failure in resurfacing arthroplasty of the hip are likely to be the design and geometry of the component and the orientation of the acetabular component


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 465 - 468
1 Aug 1982
McDonald I

Twenty-six patients with rheumatoid arthritis who had undergone bilateral replacement of the hip and knee were reviewed at a mean follow-up time of 51.6 months. A further operation was necessary in five patients due to complications of replacement of the knee, and seven patients still had significant pain in at least one replaced joint. There were no cases of infection due to operation. Seventeen of the patients still used walking aids, but one-third of these did so because of pain in joints that had not been replaced. Patients preferred painless total replacement of the hip to that of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 4 | Pages 561 - 566
1 Nov 1954
Devas MB

All the cup and replacement arthroplasties of the hip at the Middlesex Hospital performed two or more years ago—110 cases—have been reviewed. Cup arthroplasty was the more successful


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 922 - 928
1 Jul 2010
Bose VC Baruah BD

We performed 96 Birmingham resurfacing arthroplasties of the hip in 71 consecutive patients with avascular necrosis of the femoral head. A modified neck-capsule-preserving approach was used which is described in detail. The University of California, Los Angeles outcome score, the radiological parameters and survival rates were assessed. The mean follow-up was for 5.4 years (4.0 to 8.1). All the patients remained active with a mean University of California, Los Angeles activity score of 6.86 (6 to 9). Three hips failed, giving a cumulative survival rate of 95.4%. With failure of the femoral component as the endpoint, the cumulative survival rate was 98.0%. We also describe the combined abduction-valgus angle of the bearing couple, which is the sum of the inclination angle of the acetabular component and the stem-shaft angle, as an index of the optimum positioning of the components in the coronal plane. Using a modified surgical technique, it is possible to preserve the femoral head in avascular necrosis by performing hip resurfacing in patients with good results


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 4 | Pages 614 - 622
1 Nov 1957
Denham RA Alexander WL

1. Two hundred and eleven cases of arthroplasty of the hip have been studied in an attempt to establish the causes of success and failure by comparing the excellent, good and bad results. 2. The findings suggest that the result of an arthroplasty depends largely upon four factors: the surgical approach to the hip joint, the acetabular roof, the interposition substance, and the early post-operative complications. 3. Some important points in the technique of operation and in the post-operative management are described


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 892 - 900
1 Jul 2016
Atrey A Heylen S Gosling O Porteous MJL Haddad FS

Joint replacement of the hip and knee remain very satisfactory operations. They are, however, expensive. The actual manufacturing of the implant represents only 30% of the final cost, while sales and marketing represent 40%. Recently, the patents on many well established and successful implants have expired. Companies have started producing and distributing implants that purport to replicate existing implants with good long-term results. The aims of this paper are to assess the legality, the monitoring and cost saving implications of such generic implants. We also assess how this might affect the traditional orthopaedic implant companies. Cite this article: Bone Joint J 2016;98-B:892–900


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 1 | Pages 44 - 47
1 Feb 1976
Haw C Gray D

The results of excision arthroplasty on forty hips in thirty-two patients have been studied by personal review. The mean follow-up was ten years and the results were graded in the Lazansky system. The outcome was fairly predictable, most patients achieving a fair to good result. The patients were satisfied with the operation in unilateral cases as a secondary operation, but it was generally unsatisfactory as a primary procedure or when performed bilaterally. Pain relief was satisfactory, and previously infected hips achieved sound wound and bone healing. Half could walk with no aid or one stick. No correlation could be found between the radiological appearances and the quality of the result


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 35 - 39
1 Jan 2006
Beaulé PE Campbell PA Hoke R Dorey F

During hip resurfacing arthroplasty, excessive valgus positioning or surgical technique can result in notching of the femoral neck. Although mechanical weakening and subsequent fracture of the femoral neck are well described, the potential damage to the retinacular vessels leading to an ischaemic event is relatively unknown. Using laser Doppler flowmetry, we measured the blood flow in 14 osteoarthritic femoral heads during routine total hip replacement surgery, before and after notching of the femoral neck. In ten hips there was a reduction in blood flow of more than 50% from the baseline value after simulated notching of the femoral neck. Our results suggest that femoral head vascularity in the osteoarthritic state is similar to the non-arthritic state, where damage to the extraosseous vessels can predispose to avascular necrosis. Surgeons who perform resurfacing arthroplasty of the hip should pay careful attention to these vessels by avoiding excessive dissection around the femoral neck and/or notching


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 4 | Pages 393 - 397
1 Nov 1977
Williams E Taylor A Arden G Edwards D

In fifty-six patients with ankylosing spondylitis three types of arthroplasty had been performed in ninety-nine hips. Forty-one of the patients were men and fifteen were women, their average age at operation being forty-two years. Primary pseudarthrosis produced well-satisfied patients, but only a fair result in five hips, whereas cup arthroplasty resulted in a poor outcome for eight hips, all of which needed revision. Total replacement of eighty-six hips, however, led to 73 per cent being graded as good or excellent up to ten years later. The main complications were deep infection of five hips, para-articular ossification around nine hips (six leading to bony ankylosis), and fibrous ankylosis of six hips


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 2 | Pages 191 - 197
1 May 1964
Charnley J Ferreira ADS

1 . The results of transplanting the greater trochanter in 225 "low-friction" arthroplasties of the hip have been examined. 2. Non-union occurred in an average of 7 per cent of cases. 3. When non-union occurred the results still showed improvement. 4. Four different methods of fixation were used, of which that using two wires, crossed in the horizontal and coronal planes, never failed to secure union. 5. Transplantation of the greater trochanter to the best position is only possible if the neck of the femur is shortened or if the centre of motion of the arthroplasty is displaced medially by deepening the acetabulum, or by a combination of both. 6. In the best position the transplanted trochanter considerably improved active abduction against gravity


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 538 - 541
1 Apr 2007
De Haan R Campbell P Reid S Skipor AK De Smet K

A prospective study of serum and urinary ion levels was undertaken in a triathlete who had undergone a metal-on-metal resurfacing arthroplasty of the hip four years previously. The one month study period included the final two weeks of training, the day of the triathlon, and the two weeks immediately post-race. Serum cobalt and chromium levels did not vary significantly throughout this period, including levels recorded on the day after the 11-hour triathlon. Urinary excretion of chromium increased immediately after the race and had returned to pre-race levels six days later. The clinical implications are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1019 - 1024
1 Aug 2007
Hing CB Young DA Dalziel RE Bailey M Back DL Shimmin AJ

Narrowing of the femoral neck after resurfacing arthroplasty of the hip has been described previously in both cemented and uncemented hip resurfacing. The natural history of narrowing of the femoral neck is unknown. We retrospectively measured the diameter of the femoral neck in a series of 163 Birmingham hip resurfacings in 163 patients up to a maximum of six years after operation to determine the extent and progression of narrowing. There were 105 men and 58 women with a mean age of 52 years (18 to 82). At a mean follow-up of five years, the mean Harris hip score was 94.8 (47 to 100) and the mean flexion of the hip 112.5° (80° to 160°). There was some narrowing of the femoral neck in 77% (125) of the patients reviewed, and in 27.6% (45) the narrowing exceeded 10% of the diameter of the neck. A multiple logistic regression analysis showed a significant association (chi-squared test (derived from logistic regression) p = 0.01) of narrowing with female gender and a valgus femoral neck/shaft angle. There was no significant association between the range of movement, position or size of the component or radiological lucent lines and narrowing of the neck (chi-squared test; p = 0.10 (flexion), p = 0.08 (size of femoral component), p = 0.09 (size of acetabular component), p = 0.71 (femoral component angulation), p = 0.99 (lucent lines)). There was no significant difference between the diameter of the neck at a mean of three years (2.5 to 3.5) and that at five years (4.5 to 5.5), indicating that any change in the diameter of the neck had stabilised by three years (sign rank test, p = 0.60). We conclude that narrowing of the femoral neck which is found with the Birmingham hip resurfacing arthroplasty is in most cases associated with no adverse clinical or radiological outcome up to a maximum of six years after the initial operation


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 4 | Pages 720 - 731
1 Nov 1968
Ring PA

1. A complete replacement arthroplasty of the hip is described in which both components are inherently stable. 2. The arthroplasty does not require the use of acrylic cement. 3. It is appropriate for the treatment of the severely arthritic hip in which arthrodesis is not indicated, and for the mobilisation of two stiff and painful hips at any age. 4. It can be performed on both sides at the same time. 5. It produces a stable, pain-free and mobile joint in a high proportion of cases, and has appeared not to deteriorate over periods of up to four years


The Journal of Bone & Joint Surgery British Volume
Vol. 32-B, Issue 2 | Pages 166 - 173
1 May 1950
Judet J Judet R

We have endeavoured to make known the results of a simple type of arthroplasty of the hip which is well tolerated even by elderly patients. It has not been the purpose of this article to compare former operations with our own, a newcomer in the field of surgery of the hip. In particular we do not wish to compare our comparatively recent results with Smith-Petersen's well-established method of cup arthroplasty—a magnificent contribution to the surgery of the region. The results we have already obtained, however, appear sufficiently favourable to merit further study and development of the method. If the future confirms the value of our early results, we shall perhaps be able to suggest operation to patients who suffer more from loss of function than from pain


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 1 | Pages 59 - 75
1 Feb 1948
Smith-Petersen MN

This is the first time that the principle of the mould—the principle of guiding the repair of nature for the purpose of recreating a destroyed or damaged structure, has been applied to surgery. The evolution of the method to its present encouraging stage is the result of the co-operative, professional family spirit of the Massachusetts General Hospital. We all share in it. We share it with the general surgeon because of his contributions to surgical technique. We share it with the "medical man" because of his pre-operative and post-operative care of the patient; because of his guidance as to when, and when not, to operate; and because of the many friendly arguments which are productive of so much good. We share it with the anaesthetist because of his clinical judgment of the patient, his selection of anaesthetic agent, and his continuous, conscientious administration of the anaesthetic throughout the operation. I am going to change from "we" to "I." I owe so much to my assistants, from the first to the last: Bill Rogers, Eddie Cave, George Van Gorder, Paul Norton, Milton Thompson, Otto Aufranc, and Carroll Larson. I want to thank them all for helping to carry the load, for remembering the things that I forgot, and for making helpful suggestions which often led to improvement in surgical technique or to the construction of a useful instrument. I want to pay tribute to the staff of the Orthopaedic Service of the Massachusetts General Hospital and to thank its members for kindly scepticism, constructive criticism, and neverfailing loyal support. The subject of this lecture, "Evolution of Mould Arthroplasty of the Hip Joint," is appropriate for a Moynihan lecture. It is not the work of one man alone. It is the work of one man, supported by a co-operative, helpful, and friendly hospital staff. This is what Lord Moynihan strove so hard to bring about at a time when surgeons viewed one another as rivals. To quote Dr William Mayo: "It is to Lord Moynihan's everlasting credit that, largely as a result of his unceasing efforts, surgeons came to consider themselves as fellow-workers in a cause."


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 741 - 744
1 May 2005
Beaulé PE Krismer M Mayrhofer P Wanner S Le Duff M Mattesich M Stoeckl B Amstutz HC Biedermann R

Studies on the migration of an implant may be the only way of monitoring the early performance of metal-on-metal prostheses. The Ein Bild Roentgen Analyse - femoral component analysis (EBRA-FCA) method was adapted to measure migration of the femoral component in a metal-on-metal surface arthroplasty of the hip using standard antero-posterior radiographs. In order to determine the accuracy and precision of this method a prosthesis was implanted into cadaver bones. Eleven series of radiographs were used to perform a zero-migration study. After adjustment of the femoral component to simulate migration of 3 mm the radiographs were repeated. All were measured independently by three different observers. The accuracy of the method was found to be ± 1.6 mm for the x-direction and ± 2 mm for the y-direction (95% percentile). The method was validated using 28 hips with a minimum follow-up of 3.5 years after arthroplasty. Seventeen were sound, but 11 had failed because of loosening of the femoral component. The normal (control) group had a different pattern of migration compared with that of the loose group. At 29.2 months, the control group showed a mean migration of 1.62 mm and 1.05 mm compared with 4.39 mm and 4.05 mm in the failed group, for the centre of the head and the tip of the stem, respectively (p = 0.001). In the failed group, the mean time to migration greater than 2 mm was earlier than the onset of clinical symptoms or radiological evidence of failure, 19.1 versus 32.2 months (p = 0.001) and 24.8 months (p = 0.012), respectively. EBRA-FCA is a reliable and valid tool for measuring migration of the femoral component after surface arthroplasty and can be used to predict early failure of the implant. It may be of value in determining the long-term performance of surface arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 31 - 34
1 Jan 2006
Loughead JM Starks I Chesney D Matthews JNS McCaskie AW Holland JP

Resurfacing arthroplasty of the hip is being performed more frequently in the United Kingdom. The majority of these patients are younger than 55 years of age, and in this group the key benefits include conservation of femoral bone stock and the potential reduction in the rate of dislocation afforded by the larger resurfacing head. Early aseptic loosening is well recognised in patients younger than 55 years of age, and proponents of resurfacing believe that the improved wear characteristics of the metal-on-metal bearing may improve the long-term survival of this implant. There has been some concern, however, that resurfacing may not be conservative of acetabular bone. We compared a series of 33 consecutive patients who had a hybrid total hip arthroplasty with an uncemented acetabular component and a cemented femoral implant, with 35 patients undergoing a Birmingham hip resurfacing arthroplasty. We compared the diameter of the implanted acetabulum in both groups and, because they were not directly comparable, we corrected for patient size by measuring the diameter of the contralateral femoral head. The data were analysed using unpaired t-tests and analysis of covariance. There was a significantly larger acetabulum in the Birmingham arthroplasty group (mean diameter 56.6 mm vs 52.0 mm; p < 0.001). However, this group had a significantly larger femoral head diameter on the contralateral side (p = 0.03). Analysis of covariance revealed a significant difference between the mean size of the acetabular component implanted in the two operations. The greatest difference in the size of acetabulum was in those patients with a larger diameter of the femoral head. This study shows that more bone is removed from the acetabulum in hip resurfacing than during hybrid total hip arthroplasty, a difference which is most marked in larger patients


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 258 - 264
1 Mar 1997
Nakata K Ohzono K Masuhara K Matsui M Hiroshima K Ochi T

We have reviewed 65 bipolar arthroplasties of the hip in 55 patients with osteoarthritis secondary to dysplasia. The mean age at operation was 56 years (42 to 79) and the mean period of follow-up was 7.2 years (5.0 to 13.0). The average Merle d’Aubigné and Postel score before operation was 10.3 and at final follow-up 15.0. There were excellent or good results in 42 hips (65%). Migration of the outer head was observed in 50 hips (77%), most often in the group with a centre-edge angle of less than 0°, an acetabular head index of less than 60%, coverage of the outer head by the original acetabulum of less than +10° and after bone grafting of the acetabulum. This migration was progressive in 31 (62%) of the 50 hips, with massive osteolysis of the acetabulum in eight. The extent and progression of migration were closely associated with this osteolysis. Four hips required revision for extensive migration of the outer head with destruction of the acetabulum or severe acetabular osteolysis, and nine hips are awaiting revision for failure of the bipolar prosthetic head. The overall failure rate was 18%. We report major problems after bipolar hip arthroplasty for osteoarthritis secondary to hip dysplasia with progressive migration of the outer head and massive acetabular osteolysis at five years or more after operation


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1652 - 1653
1 Dec 2006
Bowman NK Bucher TA Bassily AA

Resurfacing arthroplasties of the hip are being undertaken with increasing frequency and the complications associated with this procedure are well documented. We have encountered a further problem with a fracture of the centralising peg of the femoral component in a prosthesis which had been in situ for three years