header advert
Results 21 - 40 of 78
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 631 - 635
1 Jul 2004
Uglow MG Clarke NMP


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 531 - 535
1 May 2004
Clarke A Dewnany G Neumann L Wallace WA

We describe a surgical procedure used to achieve glenothoracic fusion after one-stage radical, near total scapulectomy for primary or secondary malignant lesions in six patients. The aim was complete excision of the lesion and preservation of the glenoid to provide a fulcrum for movement of the arm.

Post-operative assessment involved determination of the range of movement and the application of the Musculoskeletal Tumour Society score and the Constant score to evaluate function. The results showed that a functional range of movement was attainable despite such radical surgery, although there was a considerable reduction in power and ability to lift.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 126 - 134
1 Jan 2004
Clarke SA Brooks RA Lee PT Rushton N

Synthetic bone substitutes provide an alternative to autograft but do not give equivalent clinical results. Their performance may be enhanced by adding osteogenic growth factors. In this study, TGFβ1 was absorbed on to a carrier of β tricalcium phosphate and Gelfoam® and used to fill a defect around a tibial implant in a rat model of revision arthoplasty.

We added 0.0, 0.02 μg, 0.1 μg or 1.0 μg of TGFβ1 to the carrier and then implanted it around an hydroxyapatite-coated stainless-steel pin in the proximal tibia of rats. The tibiae were harvested at three, six or 26 weeks and the amount of bone formation and ceramic resorption were assessed.

TGFβ1 had no effect on the amount of bone in the defect, the amount of fluorescent label incorporated or the rate of mineral apposition. The growth factor did not significantly affect the amount of β TCP remaining in the tissue at any of the time points.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 913 - 917
1 Aug 2003
Clarke MT Lee PTH Arora A Villar RN

Metal-on-metal (MOM) bearings for hip arthroplasty are increasing in popularity. Concern remains, however, regarding the potential toxicological effects of the metal ions which these bearings release.

The serum levels of cobalt and chromium in 22 patients who had undergone MOM resurfacing arthroplasty were compared with a matched group of 22 patients who had undergone 28 mm MOM total hip arthroplasty (THA).

At a median of 16 months (7 to 56) after resurfacing arthroplasty, we found the median serum levels of cobalt and chromium to be 38 nmol/l (14 to 44) and 53 nmol/l (23 to 165) respectively. These were significantly greater than the levels after 28 mm MOM THA which were 22 nmol/l (15 to 87, p = 0.021) and 19 nmol/l (2 to 58, p < 0.001) respectively.

Since the upper limit for normal patients without implants is typically 5 nmol/l, both groups had significantly raised levels of metal ions. MOM bearings of large diameter, however, result in a greater systemic exposure of cobalt and chromium ions than bearings of small diameter. This may be of relevance for potential long-term side-effects. It is not known to what extent this difference is due to corrosion of the surfaces of the component or of the wear particles produced.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 650 - 654
1 Jul 2003
Clarke MT Lee PTH Villar RN

Metal-on-metal (MOM) is a commonly used bearing notable for its ‘suction fit’ when lubricated. In this study, we examined the capacity for MOM bearings to protect against dislocation after total hip replacement (THR).

We undertook a clinical investigation to compare the rate of dislocation of MOM bearings with those of ceramic-on-polyethylene (COP) bearings and found that one MOM bearing dislocated in a series of 109 hips (0.9%) compared with nine of 145 hips (6.2%) in the COP group (p = 0.02).

We also performed an in vitro investigation comparing the peak forces generated during forced separation of the two bearings of the same dimensions at velocities from 1 to 50 cm/s. This revealed that the MOM bearing generated significant resistance to separation at all velocities (maximum mean 24 N), whereas the COP did not (maximum mean 1.9 N, p < 0.001). We conclude that MOM bearings are more stable to dislocation than COP bearings as a result of the interfacial forces provided by a thin, lubricating fluid.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages - 306
1 Mar 2003
Clarke NMP


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 307 - 307
1 Mar 2003
MYERSON MS CLARKE NMP


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1084 - 1085
1 Sep 2002
CHESSER TJS LANGDON IJ OGILVIE C SARANGI PP CLARKE AM


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 418 - 425
1 Apr 2002
Cashman JP Round J Taylor G Clarke NMP

Between June 1988 and December 1997, we treated 332 babies with 546 dysplastic hips in a Pavlik harness for primary developmental dysplasia of the hip as detected by the selective screening programme in Southampton. Each was managed by a strict protocol including ultrasonic monitoring of treatment in the harness. The group was prospectively studied during a mean period of 6.5 ± 2.7 years with follow-up of 89.9%. The acetabular index (AI) and centre-edge angle of Wiberg (CEA) were measured on annual radiographs to determine the development of the hip after treatment and were compared with published normal values.

The harness failed to reduce 18 hips in 16 patients (15.2% of dislocations, 3.3% of DDH). These required surgical treatment. The development of those hips which were successfully treated in the harness showed no significant difference from the normal values of the AI for the left hips of girls after 18 months of age. Of those dysplastic hips which were successfully reduced in the harness, 2.4% showed persistent significant late dysplasia (CEA < 20°) and 0.2% persistent severe late dysplasia (CEA < 15°). All could be identified by an abnormal CEA (< 20°) at five years of age, and many from the progression of the AI by 18 months. Dysplasia was considered to be sufficient to require innominate osteotomy in five (0.9%). Avascular necrosis was noted in 1% of hips treated in the harness.

We conclude that, using our protocol, successful initial treatment of DDH with the Pavlik harness appears to restore the natural development of the hip to normal. We suggest that regular radiological surveillance up to five years of age is a safe and effective practice.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 269 - 272
1 Mar 2002
Conn KS Clarke MT Hallett JP

Templates are used in the preoperative planning of many orthopaedic procedures. The magnification of the bones on preoperative radiographs can vary despite using standardised radiological techniques. Templates will give misleading measurements unless this magnification is quantified.

A coin may be used to calculate the magnification, with significant improvement in the accuracy of templating (p = 0.05). A group of patients undergoing uncemented arthroplasty of the hip was at high risk for intraoperative fracture of the femur because the magnification of the radiograph was larger than that of the template.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 8 | Pages 1209 - 1210
1 Nov 2001
CHESSER TJS SARANGI PP LANGDON IJ OGILVIE C CLARKE AM


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1046 - 1049
1 Sep 2001
Phillips SA Griffiths WEG Clarke NMP

We reviewed the management of 100 cases of slipped upper femoral epiphysis treated over a period of 26 years. A total of 14 slips was identified as unstable on admission. These underwent reduction and stabilisation within 24 hours of the onset of severe symptoms. Of the 86 stable slips four progressed to avascular necrosis (AVN), which was not seen in the unstable slips. The literature on slipped upper femoral epiphysis suggests that the acute unstable slip is at higher risk of developing AVN. We recommend reduction and stabilisation of unstable slips within 24 hours of the onset of symptoms in order to reduce the risk of AVN.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 423 - 426
1 Apr 2001
Chesser TJS Langdon IJ Ogilvie C Sarangi PP Clarke AM

Splitting fractures of the humeral head are rare; part of the humeral head dislocates and the unfractured part remains attached to the shaft. We report eight cases in young patients. In five the diagnosis was made at presentation: three had minimal internal fixation using a superior subacromial approach, one had a closed reduction and one a primary prosthetic replacement. All five patients regained excellent function with no avascular necrosis at two years. In three the injury was initially unrecognised; two developed a painless bony ankylosis and one is awaiting hemiarthroplasty.

It is important to obtain the three trauma radiographic views to diagnose these unusual fractures reliably. CT delineates the configuration of the fracture. In young patients open reduction and internal fixation seems preferable to replacement of the humeral head, since we have shown that the head is potentially viable.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 309 - 309
1 Mar 2001
UGLOW MG CLARKE NMP


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 40 - 44
1 Jan 2001
Clarke MT Longstaff L Edwards D Rushton N

We have investigated whether the thigh tourniquet used during total knee replacement (TKR) influenced the development of postoperative wound hypoxia and was a cause of delayed wound healing.

We allocated randomly 31 patients (31 TKRs) to one of three groups: 1) no tourniquet; 2) tourniquet inflated at low pressure (about 225 mmHg); and 3) tourniquet inflated to high pressure of about 350 mmHg. Wound oxygenation was measured using transcutaneous oxygen electrodes.

In the first week after surgery, patients with a tourniquet inflated to a high pressure had greater wound hypoxia than those with a low pressure. Those without a tourniquet also had wound hypoxia, but the degree and duration were less pronounced than in either of the groups with a tourniquet.

Use of a tourniquet during TKR can increase postoperative wound hypoxia, especially when inflated to high pressures. Our findings may be relevant to wound healing and the development of wound infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 931 - 932
1 Aug 2000
O’HARA LJ BARLOW IW CLARKE NMP


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 739 - 743
1 Jul 2000
Uglow MG Clarke NMP

Between 1988 and 1995, we studied 91 club feet from a series of 120 recalcitrant feet in 86 patients requiring surgical treatment. There were 48 boys and 20 girls. The mean age at operation was 8.9 months. Surgery consisted of an initial plantar medial release followed two weeks later by a posterolateral release. This strategy was adopted specifically to address the problems of wound healing associated with single-stage surgery and to ascertain the rate of relapse after a two-stage procedure. Immobilisation in plaster was used for three months followed by night splintage. The feet were classified preoperatively and prospectively into four grades according to the system suggested by Dimeglio et al. Grade-1 feet were postural and did not require surgery. All wounds were closed primarily. One superficial wound infection occurred in a grade-4 foot and there were no cases of wound breakdown. The rate of relapse was 20.4% in grade-3 and 65.4% in grade-4 feet.

Two-stage surgery for the treatment of club foot seems to be effective in the reduction of wound problems but does not appear to give significantly better results in terms of relapse when performed for more severe deformities.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 601 - 613
1 May 2000
Roach HI Clarke NMP

Chondrocytes at the lower zone of the growth plate must be eliminated to facilitate longitudinal growth; this is generally assumed to involve apoptosis. We attempted to provide definitive electron-microscopic evidence of apoptosis in chondrocytes of physes and chondroepiphyses in the rabbit. We were, however, unable to find a single chondrocyte with the ultrastructure of ‘classical’ apoptosis in vivo, although such a cell was found in vitro. Instead, condensed chondrocytes had a convoluted nucleus with patchy chromatin condensations while the cytoplasm was dark with excessive amounts of endoplasmic reticulum. These cells were termed ‘dark chondrocytes’. A detailed study of their ultrastructure combined with localisation methods in situ suggested a different mechanism of programmed cell death. In addition, another type of death was identified among the immature chondrocytes of the chondroepiphysis. These cells had the same nucleus as dark chondrocytes, but the lumen of the endoplasmic reticulum had expanded to fill the entire non-nuclear space, and all cytoplasm and organelles had been reduced to dark, worm-like inclusions. Since these cells appeared to be ‘in limbo’, they were termed ‘paralysed’ cells. It is proposed that ‘dark chondrocytes’ and ‘paralysed cells’ are examples of physiological cell death which does not involve apoptosis. It is possible that the confinement of chondrocytes within their lacunae, which would prevent phagocytosis of apoptotic bodies, necessitates different mechanisms of elimination.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 204 - 210
1 Mar 2000
O’Hara LJ Barlow JW Clarke NMP

We performed an audit of 71 children with consecutive displaced, extension-type supracondylar fractures of the humerus over a period of 30 months. The fractures were classified according to the Wilkins modification of the Gartland system. There were 29 type IIA, 22 type IIB and 20 type III. We assessed the effectiveness of guidelines proposed after a previous four-year review of 83 supracondylar fractures. These recommended that: 1) an experienced surgeon should be responsible for the initial management; 2) closed or open reduction of type-IIB and type-III fractures must be supplemented by stabilisation with Kirschner (K-) wires; and 3) K-wires of adequate thickness (1.6 mm) must be used in a crossed configuration.

The guidelines were followed in 52 of the 71 cases. When they were observed there were no reoperations and no malunion. In 19 children in whom they had not been observed more than one-third required further operation and six had a varus deformity. Failure to institute treatment according to the guidelines led to an unsatisfactory result in 11 patients. When they were followed the result of treatment was much better. We have devised a protocol for the management of these difficult injuries.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 999 - 1004
1 Nov 1998
Wilkinson JM Scott BW Clarke AM Bell MJ

The Sheffield Expanding Intramedullary Rod System was developed after experiencing problems with existing rod systems in the management of osteogenesis imperfecta. Between 1986 and 1996 we treated 74 bones in the lower limb in 28 children at a median follow-up of 5.25 years. We have reviewed 24 children with a total of 60 rods.

Before surgery, all children had had multiple fractures of the lower limb. At review eight patients had experienced no further fractures, but three had suffered five or more subsequently.

Before initial stabilisation, 15 children had never walked, and only three (13%) used walking as their main means of mobility. After surgery, half of those who showed motor arrest were able to walk (p = 0.016). The number of patients able to walk, with or without aids, increased to 17 (p = 0.0001).

We have experienced no evidence of epiphyseal damage after the procedure, and complication rates requiring rod exchange have been low (7%).