header advert
Results 161 - 180 of 352
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 633 - 638
1 May 2007
Matthews TJW Smith SR Peach CA Rees JL Urban JPG Carr AJ

We have undertaken an in vivo assessment of the tissue metabolism and cellular activity in torn tendons of the rotator cuff. Cellular oxygen consumption was measured in 13 patients undergoing mini-open repair of small, medium, large and massive full-thickness tears. Measurements were also taken from three control patients who were undergoing open stabilisation of the shoulder with grossly normal tendons. The level of oxygen and nitrous oxide was measured amperometrically using silver needle microelectrodes at the apex of the tear and 1.5 cm from its edge. With nitrous oxide indicating the degree of perfusion, oxygen consumption was calculated at each location to reflect cellular activity.

All of the torn tendons had lower levels of cellular activity than the control group. This activity was lower still in the tissue nearest to the edge of the tear with the larger tears showing the lowest activity. This indicated reduced levels of tissue metabolism and infers a reduction in tendon viability.

Our findings suggest that surgical repair of torn tendons of the rotator-cuff should include the more proximal, viable tissue, and may help to explain the high rate of re-rupture seen in larger tears.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 620 - 626
1 May 2007
Nath RK Paizi M

Residual muscle weakness in obstetric brachial plexus palsy results in soft-tissue contractures which limit the functional range of movement and lead to progressive glenoid dysplasia and joint instability. We describe the results of surgical treatment in 98 patients (mean age 2.5 years, 0.5 to 9.0) for the correction of active abduction of the shoulder. The patients underwent transfer of the latissimus dorsi and teres major muscles, release of contractures of subscapularis pectoralis major and minor, and axillary nerve decompression and neurolysis (the modified Quad procedure). The transferred muscles were sutured to the teres minor muscle, not to a point of bony insertion. The mean pre-operative active abduction was 45° (20° to 90°). At a mean follow-up of 4.8 years (2.0 to 8.7), the mean active abduction was 162° (100° to 180°) while 77 (78.6%) of the patients had active abduction of 160° or more. No decline in abduction was noted among the 29 patients (29.6%) followed up for six years or more. This procedure involving release of the contracted internal rotators of the shoulder combined with decompression and neurolysis of the axillary nerve greatly improves active abduction in young patients with muscle imbalance secondary to obstetric brachial plexus palsy.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 490 - 494
1 Apr 2007
Arimitsu S Murase T Hashimoto J Oka K Sugamoto K Yoshikawa H Moritomo H

We have measured the three-dimensional patterns of carpal deformity in 20 wrists in 20 rheumatoid patients in which the carpal bones were shifted ulnarwards on plain radiography. Three-dimensional bone models of the carpus and radius were created by computerised tomography with the wrist in the neutral position. The location of the centroids and rotational angle of each carpal bone relative to the radius were calculated and compared with those of ten normal wrists.

In the radiocarpal joint, the proximal row was flexed and the centroids of all carpal bones translocated in an ulnar, proximal and volar direction with loss of congruity. In the midcarpal joint, the distal row was extended and congruity generally well preserved. These findings may facilitate more positive use of radiocarpal fusion alone for the deformed rheumatoid wrist.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 486 - 489
1 Apr 2007
Bassi RS Simmons D Ali F Nuttall D Birch A Trail IA Stanley JK

The Acclaim total elbow replacement is a modular system which allows implantation in both unlinked and linked modes. The results of the use of this implant in primary total elbow replacement in 36 patients, operated on between July 2000 and August 2002, are presented at a mean follow-up of 36 months (24 to 49). Only one patient did not have good relief of pain, but all had improved movement and function.

No implant showed clinical or radiological loosening, although one had a lucent area in three of seven humeral zones. The short-term results of the Acclaim total elbow replacement are encouraging. However, 11 patients (30.5%) suffered an intra-operative fracture of the humeral condyle. This did not affect the outcome, or the requirement for further surgery, except in one case where the fracture failed to unite. This problem has hopefully been addressed by redesigning the humeral resection guide. Other complications included three cases of ulnar neuropathy (8.3%) and one of deep infection (2.8%).


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 330 - 334
1 Mar 2007
Cesar M Roussanne Y Bonnel F Canovas F

Between 1993 and 2002, 58 GSB III total elbow replacements were implanted in 45 patients with rheumatoid arthritis by the same surgeon. At the most recent follow-up, five patients had died (five elbows) and six (nine elbows) had been lost to follow-up, leaving 44 total elbow replacements in 34 patients available for clinical and radiological review at a mean follow-up of 74 months (25 to 143). There were 26 women and eight men with a mean age at operation of 55.7 years (24 to 77).

At the latest follow-up, 31 excellent (70%), six good (14%), three fair (7%) and four poor (9%) results were noted according to the Mayo elbow performance score. Five humeral (11%) and one ulnar (2%) component were loose according to radiological criteria (type III or type IV). Of the 44 prostheses, two (5%) had been revised, one for type-IV humeral loosening after follow-up for ten years and one for fracture of the ulnar component. Seven elbows had post-operative dysfunction of the ulnar nerve, which was transient in five and permanent in two.

Despite an increased incidence of loosening with time, the GSB III prosthesis has given favourable mid-term results in patients with rheumatoid arthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 335 - 341
1 Mar 2007
Albert J Meadeb J Guggenbuhl P Marin F Benkalfate T Thomazeau H Chalès G

In a prospective randomised trial of calcifying tendinitis of the rotator cuff, we compared the efficacy of dual treatment sessions delivering 2500 extracorporeal shock waves at either high- or low-energy, via an electromagnetic generator under fluoroscopic guidance. Patients were eligible for the study if they had more than a three-month history of calcifying tendinitis of the rotator cuff, with calcification measuring 10 mm or more in maximum dimension. The primary outcome measure was the change in the Constant and Murley Score.

A total of 80 patients were enrolled (40 in each group), and were re-evaluated at a mean of 110 (41 to 255) days after treatment when the increase in Constant and Murley score was significantly greater (t-test, p = 0.026) in the high-energy treatment group than in the low-energy group. The improvement from the baseline level was significant in the high-energy group, with a mean gain of 12.5 (−20.7 to 47.5) points (p < 0.0001). The improvement was not significant in the low-energy group. Total or subtotal resorption of the calcification occurred in six patients (15%) in the high-energy group and in two patients (5%) in the low-energy group.

High-energy shock-wave therapy significantly improves symptoms in refractory calcifying tendinitis of the shoulder after three months of follow-up, but the calcific deposit remains unchanged in size in the majority of patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 327 - 329
1 Mar 2007
Price AE DiTaranto P Yaylali I Tidwell MA Grossman JAI

We retrospectively reviewed 26 patients who underwent reconstruction of the shoulder for a medial rotation contracture after birth injury of the brachial plexus. Of these, 13 patients with a mean age of 5.8 years (2.8 to 12.9) received an injection of botulinum toxin type A into the pectoralis major as a surgical adjunct. They were matched with 13 patients with a mean age of 4.0 years (1.9 to 7.2) who underwent an identical operation before the introduction of botulinum toxin therapy to our unit.

Pre-operatively, there was no significant difference (p = 0.093) in the modified Gilbert shoulder scores for the two groups. Post-operatively, the patients who received the botulinum toxin had significantly better Gilbert shoulder scores (p = 0.012) at a mean follow-up of three years (1.5 to 9.8).

It appears that botulinum toxin type A produces benefits which are sustained beyond the period for which the toxin is recognised to be active. We suggest that by temporarily weakening some of the power of medial rotation, afferent signals to the brain are reduced and cortical recruitment for the injured nerves is improved.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 202 - 205
1 Feb 2007
Arya AP Kulshreshtha R Kakarala GK Singh R Compson JP

Disorders of the pisotriquetral joint are well recognised as the cause of pain on the ulnar side of the wrist. The joint is not usually examined during routine arthroscopy because it is assumed to have a separate joint cavity to the radiocarpal joint, although there is often a connection between the two.

We explored this connection during arthroscopy and in fresh-frozen cadaver wrists and found that in about half of the cases the pisotriquetral joint could be visualised through standard wrist portals. Four different types of connection were observed between the radiocarpal joint and the pisotriquetral joint. They ranged from a complete membrane separating the two, to no membrane at all, with various other types of connection in between.

We recommend that inspection of the pisotriquetral joint should be a part of the protocol for routine arthroscopy of the wrist.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 196 - 201
1 Feb 2007
Veitch S Blake SM David H

We prospectively reviewed 14 patients with deficiency of the proximal pole of the scaphoid who were treated by rib osteochondral replacement arthroplasty.

Improvement in wrist function occurred in all except one patient with enhanced grip strength, less pain and maintenance of wrist movement. In 13 patients wrist function was rated as good or excellent according to the modified wrist function score of Green and O’Brien. The mean pre-operative score of 54 (35 to 80) rose to 79 (50 to 90) at review at a mean of 64 months (27 to 103). Carpal alignment did not deteriorate in any patient and there were no cases of nonunion or significant complications.

This procedure can restore the mechanical integrity of the proximal pole of the scaphoid satisfactorily and maintain wrist movement while avoiding the potential complications of alternative replacement arthroplasty techniques and problems associated with vascularised grafts and salvage techniques.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 189 - 195
1 Feb 2007
Levy JC Virani N Pupello D Frankle M

We report the use of the reverse shoulder prosthesis in the revision of a failed shoulder hemiarthroplasty in 19 shoulders in 18 patients (7 men, 11 women) with severe pain and loss of function. The primary procedure had been undertaken for glenohumeral arthritis associated with severe rotator cuff deficiency.

Statistically significant improvements were seen in pain and functional outcome. After a mean follow-up of 44 months (24 to 89), mean forward flexion improved by 26.4° and mean abduction improved by 35°. There were six prosthesis-related complications in six shoulders (32%), five of which had severe bone loss of the glenoid, proximal humerus or both. Three shoulders (16%) had non-prosthesis related complications.

The use of the reverse shoulder prosthesis provides improvement in pain and function for patients with failure of a hemiarthroplasty for glenohumeral arthritis and rotator cuff deficiency. However, high rates of complications were associated with glenoid and proximal humeral bone loss.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 206 - 209
1 Feb 2007
Houshian S Chikkamuniyappa C Schroeder H

We present the outcome of the treatment of chronic post-traumatic contractures of the proximal interphalangeal joint by gradual distraction correction using an external fixator. A total of 30 consecutive patients with a mean age of 34 years (17 to 54) had distraction for a mean of 16 days (10 to 22). The fixator was removed after a mean of 29 days (16 to 40). Assessment at a mean of 34 months (18 to 54) after completion of treatment showed that the mean active range of movement had significantly increased by 63° (30° to 90°; p < 0.001). The mean active extension gained was 47° (30° to 75°).

Patients aged less than 40 years fared slightly better with a mean gain in active range of movement of 65° (30° to 90°) compared with those aged more than 40 years, who had a mean gain in active range of movement of 55° (30° to 70°) but the difference was not statistically significant (p = 0.148).

The use of joint distraction to correct chronic flexion contracture of the proximal interphalangeal joint is a minimally-invasive and effective method of treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 62 - 65
1 Jan 2007
Ito H Matsumoto T Yoshitomi H Kakinoki R Nakamura T

We compared the outcome of peri-operative humeral condylar fractures in patients undergoing a Coonrad-Morrey semiconstrained total elbow replacement with that of patients with rheumatoid arthritis undergoing the same procedure without fractures. In a consecutive series of 40 elbows in 33 patients, 13 elbows had a fracture in either condyle peri-operatively, and 27 elbows were intact. The fractured condyle was either fixed internally or excised. We found no statistical difference in the patients’ background, such as age, length of follow-up, immobilisation period, Larsen’s radiological grade, or Steinbrocker’s stage and functional class. There was also no statistical difference between the groups in relation to the Mayo Elbow Performance Score, muscle strength, range of movement, or radiolucency around the implants at a mean of 4.8 years (1.1 to 8.0) follow-up.

We conclude that fractured condyles can be successfully treated with either internal fixation or excision, and cause no harmful effect.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1610 - 1612
1 Dec 2006
Al-Rashid M Theivendran K Craigen MAC

The use of volar locking compression plates for the treatment of fractures of the distal radius is becoming increasingly popular because of the stable biomechanical construct, less soft-tissue disturbance and early mobilisation of the wrist. A few studies have reported complications such as rupture of flexor tendons. We describe three cases of rupture of extensor tendons after the use of volar locking compression plates. We recommend extreme care when drilling and placing the distal radial screws to prevent damaging the extensor tendons.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1606 - 1609
1 Dec 2006
Seki M Nakamura H Kono H

We studied 21 patients with a spontaneous palsy of the anterior interosseous nerve. There were 11 men and 10 women with a mean age at onset of 39 years (17 to 65).

Pain around the elbow or another region (forearm, shoulder, upper arm, systemic arthralgia) was present in 17 patients and typically lasted for two to three weeks. It had settled within six weeks in every case. In ten cases the palsy developed as the pain settled. A complete palsy of flexor pollicis longus and flexor digitorum profundus to the index finger was seen in 13 cases and an isolated palsy of flexor pollicis longus in five. All patients were treated without operation. The mean time to initial muscle contraction was nine months (2 to 18) in palsy of the flexor digitorum profundus to the index finger, and ten months (1 to 24) for a complete palsy of flexor pollicis longus. An improvement in muscle strength to British Medical Research Council grade 4 or better was seen in all 15 patients with a complete palsy of the flexor digitorum profundus and in 16 of 18 with a complete palsy of flexor pollicis longus.

There was no significant correlation between the duration of pain and either the time to initial muscle contraction or final muscle strength. Prolonged pain was not always associated with a poor outcome but the age of the patient when the palsy developed was strongly correlated. Recovery occurred within 12 months in patients under the age of 40 years who achieved a final British Medical Research Council grade of 4 or better. Surgical decompression does not appear to be indicated for young patients with this condition.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1460 - 1463
1 Nov 2006
Landor I Vavrik P Jahoda D Guttler K Sosna A

We assessed the long-term results of 58 Souter-Strathclyde total elbow replacements in 49 patients with rheumatoid arthritis. The mean length of follow-up was 9.5 years (0.7 to 16.7). The mean pre-operative Mayo Elbow Performance Score was 30 (15 to 80) and at final follow-up was 82 (60 to 95). A total of 13 elbows (22.4%) were revised, ten (17.2%) for aseptic loosening, one (1.7%) for instability, one (1.7%) for secondary loosening after fracture, and one elbow (1.7%) was removed because of deep infection. The Kaplan-Meier survival rate was 70% and 53% at ten and 16 years, respectively. Failure of the ulnar component was found to be the main problem in relation to the loosening. Anterior transposition of the ulnar nerve had no influence on ulnar nerve paresthaesiae in these patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1341 - 1346
1 Oct 2006
Gille J Ince A González O Katzer A Loehr JF

This study reviews the predisposing features, the clinical, and laboratory findings at the time of diagnosis and the results of single-stage revision of prosthetic replacement of the elbow for infection.

Deep infection occurred in six of 305 (1.9%) primary total elbow replacements. The mean follow-up after revision was 6.8 years (6 months to 16 years) and the mean age at the time of revision was 62.7 years (56 to 74). All six cases with infection had rheumatoid arthritis and had received steroid therapy. The infective organism was Staphylococcus aureus. Four of the six elbows had a developed radiolucency around one component or the other. Successful single-stage exchange arthroplasty was carried out with antibiotic-loaded cement in five of the six cases. In one, the revision prosthesis had to be removed following recurrence of the infection. The functional result was good in three elbows, fair in one, poor in one and fair in the resection arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1178 - 1182
1 Sep 2006
Stanley JK Penn DS Wasseem M

Surgical access to the head of the radius is usually performed through a lateral approach. We present an alternative technique through a modified posterior approach which was developed following dissections of 22 human cadavers. An osteotomy of the supinator tuberosity was performed and reflected as a single unit with the attached annular ligament. Excellent exposure of the head of the radius was achieved, replacement of the head was undertaken and the osteotomy site repaired. The elbows were stable and had a full range of movement. The approach was then carried out on 13 patients for elective replacement of the head and was found to be safe and reproducible. In the patient group all osteotomies united, the elbows were stable and had an improved range of supination and pronation. There was no change in flexion and extension of the elbow. Complications included a haematoma and a reflex sympathetic dystrophy.

The modified posterior approach provides excellent access to the head and neck of the radius, gives good stability of the elbow and allows early mobilisation of the joint.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1173 - 1177
1 Sep 2006
Kean J Wigderowitz CA Coventry DM

We performed a double-blind, randomised controlled trial to assess the effectiveness of a continuous-infusion brachial plexus block with levobupivacaine compared with that of a standard single injection for the management of post-operative pain after surgery on the shoulder.

Eight patients were randomised to receive a pre-operative brachial plexus block using 30 ml of levobupivacaine 0.5% with adrenaline 1:200 000 followed by insertion of a 20-gauge polyamide catheter. This was connected to a disposable elastometric pump, set immediately after surgery to administer a continuous flow of levobupivacaine 0.25% at a rate of 5 ml per hour. The other eight patients were randomised to receive only the initial injection of 30 ml. The study was double-blinded with the aid of sham catheters and clamped pumps.

All patients were given regular paracetamol and were prescribed morphine through a patient-controlled analgesia pump. Motor and sensory block assessments, visual analogue scale pain scores and consumption of morphine were recorded after the operation and then at 6, 12 and 24 hours after administration of the block.

Satisfactory motor and sensory block was achieved in all patients. The mean visual analogue scale pain score at 12 hours and consumption of morphine at 24 hours after injection were significantly lower (p < 0.05) in the continuous-infusion group. This group also took longer to request their first additional analgesia and reported a significantly higher overall level of satisfaction.

Our study has shown that continuous interscalene infusion of levobupivacaine is an effective method of post-operative analgesia after major surgery of the shoulder.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1048 - 1052
1 Aug 2006
Jerosch-Herold C Rosén B Shepstone L

Locognosia, the ability to localise touch, is one aspect of tactile spatial discrimination which relies on the integrity of peripheral end-organs as well as the somatosensory representation of the surface of the body in the brain. The test presented here is a standardised assessment which uses a protocol for testing locognosia in the zones of the hand supplied by the median and/or ulnar nerves.

The test-retest reliability and discriminant validity were investigated in 39 patients with injuries to the median or ulnar nerve. Intraclass correlation coefficients were used to calculate the test-retest reliability. Discriminant validity was assessed by comparing the injured with the unaffected hand.

Excellent test-retest reliability was demonstrated for the injuries to the median (intraclass correlation coefficient 0.924, 95% confidence interval 0.848 to 1.00) and the ulnar nerves (intraclass correlation coefficient 0.859, 95% confidence interval 0.693 to 1.00). The magnitude of the difference in scores between affected and unaffected hands showed good discriminant validity. For injuries to the median nerve the mean difference was 11.1 points (1 to 33; sd 7.4), which was statistically significant (p < 0.0001, paired t-test) and for those of the ulnar nerve it was 4.75 points (1 to 13.5; sd 3.16), which was also statistically significant (paired t-test, p < 0.0001).

The locognosia test has excellent test-retest reliability, is a valid test of tactile spatial discrimination and should be included in the evaluation of outcome after injury to peripheral nerves.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 920 - 924
1 Jul 2006
Mori T Kudo H Iwano K Juji T

We studied 11 patients (14 elbows) with gross rheumatoid deformity of the elbow, treated by total arthroplasty using the Kudo type-5 unlinked prosthesis, and who were evaluated between five and 11 years after operation. Massive bone defects were augmented by autogenous bone grafts. There were no major complications such as infection, subluxation or loosening. In most elbows relief from pain and stability were achieved. The results, according to the Mayo Elbow Performance Score, were excellent in eight, good in five and fair in one. In most elbows there was minimal or no resorption of the grafted bone. There were no radiolucent lines around the stems of the cementless components. This study shows that even highly unstable rheumatoid elbows can be replaced successfully using an unlinked prosthesis, with augmentation by grafting for major defects of bone.