Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:

Aims. The purpose of this study was to assess the reliability and responsiveness to hip surgery of a four-point modified Care and Comfort Hypertonicity Questionnaire (mCCHQ) scoring tool in children with cerebral palsy (CP) in Gross Motor Function Classification System (GMFCS) levels IV and V. Methods. This was a population-based cohort study in children with CP from a national surveillance programme. Reliability was assessed from 20 caregivers who completed the mCCHQ questionnaire on two occasions three weeks apart. Test-retest reliability of the mCCHQ was calculated, and responsiveness before and after surgery for a displaced hip was evaluated in a cohort of children. Results. Test-retest reliability for the overall mCCHQ score was good (intraclass correlation coefficient 0.78), and no dimension demonstrated poor reliability. The surgical intervention cohort comprised ten children who had preoperative and postoperative mCCHQ scores at a minimum of six months postoperatively. The mCCHQ tool demonstrated a significant improvement in overall score from preoperative assessment to six-month postoperative follow-up assessment (p < 0.001). Conclusion. The mCCHQ demonstrated responsiveness to intervention and good test-retest reliability. The mCCHQ is proposed as an outcome tool for use within a national surveillance programme for children with CP. Cite this article: Bone Jt Open 2023;4(8):580–583


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 198 - 203
1 Jan 2021
Min JJ Kwon S Sung KH Lee KM Chung CY Park MS

Aims. Hip displacement, common in patients with cerebral palsy (CP), causes pain and hinders adequate care. Hip reconstructive surgery (HRS) is performed to treat hip displacement; however, only a few studies have quantitatively assessed femoral head sphericity after HRS. The aim of this study was to quantitatively assess improvement in hip sphericity after HRS in patients with CP. Methods. We retrospectively analyzed hip radiographs of patients who had undergone HRS because of CP-associated hip displacement. The pre- and postoperative migration percentage (MP), femoral neck-shaft angle (NSA), and sphericity, as determined by the Mose hip ratio (MHR), age at surgery, Gross Motor Function Classification System level, surgical history including Dega pelvic osteotomy, and triradiate cartilage status were studied. Regression analyses using linear mixed model were performed to identify factors affecting hip sphericity improvement. Results. A total of 108 patients were enrolled. The mean preoperative MP was 58.3% (SD 31.7%), which improved to 9.1% (SD 15.6%) at the last follow-up. NSA and MHR improved from 156.5° (SD 11.5°) and 82.3% (SD 8.6%) to 126.0° (SD 18.5°) and 89.1% (SD 9.0%), respectively. Factors affecting the postoperative MHR were preoperative MP (p = 0.005), immediate postoperative MP (p = 0.032), and history of Dega osteotomy (p = 0.046). Conclusion. We found that hip sphericity improves with HRS. Preoperative MP, reduction quality, and acetabular coverage influence femoral head remodelling. We recommend that surgeons should consider intervention early before hip displacement progresses and that during HRS, definite reduction and coverage of the femoral head should be obtained. Cite this article: Bone Joint J 2021;103-B(1):198–203


Bone & Joint Open
Vol. 4, Issue 5 | Pages 363 - 369
22 May 2023
Amen J Perkins O Cadwgan J Cooke SJ Kafchitsas K Kokkinakis M

Aims

Reimers migration percentage (MP) is a key measure to inform decision-making around the management of hip displacement in cerebral palsy (CP). The aim of this study is to assess validity and inter- and intra-rater reliability of a novel method of measuring MP using a smart phone app (HipScreen (HS) app).

Methods

A total of 20 pelvis radiographs (40 hips) were used to measure MP by using the HS app. Measurements were performed by five different members of the multidisciplinary team, with varying levels of expertise in MP measurement. The same measurements were repeated two weeks later. A senior orthopaedic surgeon measured the MP on picture archiving and communication system (PACS) as the gold standard and repeated the measurements using HS app. Pearson’s correlation coefficient (r) was used to compare PACS measurements and all HS app measurements and assess validity. Intraclass correlation coefficient (ICC) was used to assess intra- and inter-rater reliability.