Chronic bone infections and infected fractures are often treated with excision of the dead bone and implantation of biomaterials which elute antibiotics. Gentamicin has been a preferred drug for local delivery, but this could induce renal dysfunction due to systemic toxicity. This is a particular concern in patients with pre-existing chronic renal disease treated with new antibiotic carriers which achieve very high peak levels of gentamicin in the first few days after surgery. 163 patients (109 males; average age 51.6 years) with Cierny-Mader Type 3 or 4 chronic osteomyelitis had a single-stage operation with excision of the dead bone, filling of the osseous defect with a calcium sulphate-hydroxyapatite carrier, containing gentamicin and immediate soft tissue closure2. No patient was given systemic gentamicin or other renal toxic antibiotics. Mean carrier volume was 10.9mls (range 1–30mls) and mean gentamicin dosing was 190.75mg (maximum 525mg). Seven patients had pre-existing renal disease (4 diabetic nephropathy, 1 nephrotic syndrome, 1 renal transplant and 1 previous acute kidney injury). Serum creatinine levels were collected pre-operatively and during the first seven days post-operatively. Glomerular filtration rate (GFR) was calculated using the CKD-epi creatinine equation. Renal function was defined using the Chronic Kidney Disease (CKD) Staging system.Aim
Method
The treatment of chronic bone infection often involves excision of dead bone and implantation of biomaterials which elute antibiotics. Gentamicin is a preferred drug for local delivery, but its systemic use carries a well-established risk of nephrotoxicity. We aim to establish the risk of renal injury with local delivery in a ceramic carrier. 163 consecutive patients with Cierny-Mader Type 3 or 4 chronic osteomyelitis were treated with a single-stage operation which included filling of the osseous defect with a calcium sulphate-hydroxyapatite carrier containing gentamicin. The mean carrier volume used was 10.9mls, leading to a mean implanted gentamicin dose of 191.3mg (maximum 525mg). Serum creatinine levels were collected pre-operatively and during the first seven days post-operatively. Renal impairment was graded using the Chronic Kidney Disease (CKD) Staging system, and AKI was assessed using the RIFLE criteria.Introduction
Materials and Methods
Periprosthetic joint infections (PJI) continue to be a diagnostic challenge for orthopedic surgeons. Chronic PJI are sometimes difficult to diagnose and occasionally present in a subclinical fashion with normal CRP/ESR and/or normal joint aspiration. Some institutions advocate for routine use of intraoperative culture swabs at the time of all revision surgeries to definitively rule out infection. The purpose of this study is to determine whether routine intraoperative cultures is an appropriate and cost effective method of diagnosing subclinical chronic PJI in revision joint replacement patients with a low clinical suspicion for infection. We performed a retrospective chart review and identified 33 patients that underwent revision hip or knee replacement from a single surgeon over a five-month period. The AAOS guidelines for preoperative PJI workup were followed. 13 patients were diagnosed preoperatively with infection and excluded from the study. 20 patients underwent revision joint replacement and three separate cultures swabs were taken for each patient to help in determining true-positive cultures. Infectious Disease was consulted for all patients with any positive culture. Culture results were reviewed. At our hospital, the cost billed to insurance for a single culture is $1,458.58. We did not calculate the cost of the consultant fee. Three (15%) of the 20 revision arthroplasty patients had a single positive culture. Infectious Disease consultants diagnosed all three of these positive cultures as contaminants. None of the patients had a true-positive intraoperative culture. The total cost billed by the hospital to obtain these cultures in all 20 patients was $87,514.80 In our study, obtaining a set of three intraoperative cultures for those patients with a negative preoperative infection workup was not only cost prohibitive but did not diagnose a single subclinical infection. Studies to find other more reliable, accurate, and cost effective alternatives to diagnose PJI are warranted. In patients undergoing revision hip or knee arthroplasty with a low preoperative clinical suspicion for infection, it does not seem that routine intraoperative culture swabs are necessary or cost effective method for diagnosing subclinical periprosthetic joint infection.
To assess the accuracy of predicted and actual cut alignment from PMCB versus intra-operative computer navigation. We performed 10 primary TKA cases in which both PMCB and computer navigation were used. Standard imaging was performed to generate the plan and the cutting blocks to perform the case with PMCB. At the start of the case, standard navigation procedure was followed using the Praxim navigation system to register the centre of the femoral head, femoral and tibial surfaces and alignment. The PMCB were applied to the femur and tibia and the navigation cut-registering shim was placed in the slot on the PMCB to record the position and alignment of the proposed cut in the coronal and sagittal planes. The following parameters were compared: overall limb alignment in the coronal plane, distal femoral coronal angle, depth of resection on medial and lateral distal femoral condyle and depth of resection on medial and lateral proximal tibia. Differences in the pre-operative PMCB plan, intra-operative navigation assessment and proposed cuts after application of the blocks intra-operatively were recorded.Aim
Method
Venham Situational Anxiety Score was performed before and immediately after removal of K-wires. University College London Hospital sedation score was recorded every 20 minutes.
There was no significant difference in anxiety scores between the groups either before or after wire removal. The change in scores was not significantly different between the 2 groups. However, 45% of children in the active group had reduced anxiety levels in the active group compared to 18% of children given placebo but this difference was not significant (p=0.102). No child was excessively sedated but one in the active group became agitated and restless.
This prospective randomised controlled trial recruited 420 patients into 3 equal groups: extension, 3 &
6 hrs flexion. This trial found a significant reduction in blood loss(12%, p=0.006) and length of stay(1/2 day, p=0.006) in the 6 hour flexion group, compared the extension group. There was no significant difference in pain or complication rates (excluding nerve palsy). 2 patients in the 6 hour group had postoperative nerve palsy, however, this palsy was sensory only and markedly different to that found previously. Although the palsy rate in this study is similar(1.4%) to quoted literature rates (1.3%) for TKA, it is difficult to know if the jig was the cause of palsy as the there was a difference between those caused by the old metal jig (painful) and those in this study (sensory loss only).
Irradiating allograft bone may compromise the mechanical stability of the prosthesis-bone construct, potentially having adverse effects on the outcome of femoral impaction grafting at revision hip replacement. This in vitro study aimed to determine the effect of irradiation of allograft bone used in femoral impaction grafting on initial prosthesis stability. Morsellised ovine femoral head bone was irradiated at 0 kGy (control), 15 kGy and 60 kGy. For each group, six ovine femurs were implanted with a cemented polished double taper stem following femoral impaction bone grafting. Dynamic hip joint loading was applied to the femoral head using a servo-hydraulic materials testing machine. The primary outcome was stem micromotion. Tri-axial micromotion of the stem relative to the bone at two sites was measured using linear variable differential transformers and non-contact laser motion transducers. Statistical analysis was performed using SPSS. Compared to the control and 15 kGy groups, specimens in the 60 kGy group demonstrated statistically significant greater micromotion in the axial, antero-posterior and medio-lateral axes. A multi-factorial post-hoc power analysis based on the overall effect of group size indicated a power of 0.7. There was no difference in micromotion between the control and 15 kGy groups. The average micromotion in the axial axes was 63μm in the control and 59μm in the 15 kGy group. The results of this study suggest that a maximum irradiation dose of 15 kGy may not affect initial prosthesis stability following femoral impaction grafting in this model and provide the basis for us to now proceed to in-vivo studies examining the effect of irradiated bone on implant stability over time.
Our purpose wasto determine if oral midazolam reduces the anxiety of children undergoing removal of percutaneous Kirschner wires (K-wires) from the distal humerus in the Orthopaedic Outpatient Department. This was a prospective double blind, randomised controlled trial. 46 children aged between 3 and 12 years who had supracondylar fractures of the distal humerus internally fixed with K-wires were randomised into 2 groups. 0.2mg/kg oral midazolam (active group) or the same volume of an oral placebo (control group) was administered 30 minutes prior to removal of K-wires. Venham Situational Anxiety Score was performed before and immediately after removal of K-wires. University College London Hospital sedation score was recorded every 20 minutes. 42 children with an average age of 7.1 years (range 3.6–12.3 years) had complete documentation for analysis. The two groups had similar demographics. All wires were removed in the clinic with or without midazolam. There was no significant difference in anxiety scores between the groups either before or after wire removal. The change in scores was not significantly different between the 2 groups. However, 45% of children in the active group had reduced anxiety levels in the active group compared to 18% of children given placebo but this difference was not significant (p=0.102). No child was excessively sedated but one in the active group became agitated and restless. The anxiety scores before and after wire removal in the active group were not significantly different from the placebo group scores. We do not recommend the routine administration of midazolam (0.2 mg/kg) to all children requiring k-wire removal in the outpatient department.
The term ‘posterior condylar offset’ (PCO) is defined as the distance from a line projected along the posterior cortex of the femur to the maximum convexity of the posterior condyles. Its magnitude has been found to correlate with final flexion following PCL-retaining TKA, if reduced by more than 3mm post-operatively. ( Tibial slope is the angle between a line drawn parallel to the articular surface and a line drawn perpendicular to the long axis of the tibia on a lateral radiograph. Increasing the tibial slope in PCL-retaining TKA has been shown to improve maximal flexion of an average 1.7 degrees flexion for every extra degree on the tibial slope. (
The mean pre-operative PCO was 25.9 mm (21 – 35), whilst the mean post-operative PCO was 26.9 mm (21 – 34). The difference in preoperative and postoperative PCO ranged from −6 mm to + 5 mm (average, +1mm). Three patients 4% had more than 3mm reduction in their PCO following TKA (range −4mm to −6mm). 16% had their post-operative PCO increased by more than 3mm (range 4mm – 5mm). The remaining 80% had their PCO restored to within 3mm either way. The mean post operative tibial slope was 6.6° with a range of 5–9°, 38% measuring 6°, 21% at 7°, 17% at 8°and 5° and the remaining 7% at 9°. Of the three patients whose PCO was reduced by more than 3mm, one had the same flexion 1 year postoperatively, one had an increase of 14 degrees, and unfortunately the third died before their 1 year review. Using regression analysis, the strongest predictor of one-year flexion for this study group was the preoperative flexion value. The change in PCO and angle of the tibial slope had no significant influence on one-year flexion.
192 patients (88.5%) were discharged to their own homes with the main determinant of discharge to the patients’ own home being the availability of adequate family support.
The same trend was reflected in the PCV drops of 0.111, 0.133 and 0.1273 respectively. Transfusion rates for the three groups showed that those on aspirin and another NSAID had the highest rate with an average of 0.235 units per patient compared to 0.136 for those on aspirin only and 0.10 for those on neither aspirin nor NSAID.
The ingestion of aspirin and NSAID does not increase blood loss following TKA but significantly have a lower preoperative Hb level. We feel that pre-operative Haemoglobin levels are the best predictors of transfusion requirements following total knee arthroplasty.
One of the potential benefits cited for minimally invasive THA is reduced soft tissue trauma resulting in less post-operative pain, less swelling and earlier mobilisation. Objective evidence, from well designed prospective studies, for these benefits remains lacking. The aim of this study was to investigate whether a minimally invasive technique in THA results in a reduced acute phase response and reduced post-operative swelling compared to THA performed through a standard incision of 16cm.
Treatment of deep wound infections included 6 who had a Girdlestone procedure, 2 had wound washout, debridement and 2 who had removal of DHS. All received IV antibiotics. 2 patients were deemed unfit for surgery and received IV antibiotics only. 3 patients with a deep wound infection (23%) died (2 deemed unfit for surgery, and 1 Girdlestone) during their admission. 85% of the readmissions had an ASA score of three or over. We looked at the length of operation time and found that 15 took less than 45 minutes, 4 took between 45 and 60 minutes and one took over 60 minutes. Three of the operations which took over 45 minutes developed deep infections.
Currently mixing system allow for the preparation of the bone cement under the application of a vacuum in a closed, sealed chamber by means of a repeatable mixing action. These systems are perceived to be repeatable, reliable, and operator independent. The objective of this study is to evaluate the quality and consistency of acrylic bone cement prepared by scrub staff in an orthopaedic theatre using a commercially available third generation vacuum mixing syringe, in terms of the level of voids within the cement microsturcture.
Bone cement was mixed using a commercially available third generation mixing device (vacuum = −550mmHg) at Musgrave Park Hospital, Belfast, Northern Ireland. The cement was mixed according to the device manufacturers’ instructions for use. Mixing was carried out during a joint replacement surgery by a number of experienced theatre scrub staff (n = 35). The cement remaining at the end of the procedure was allowed to cure within the delivery nozzle, made from linear low-density polyethylene (LLDPE) and having an internal diameter of 10mm. 205 nozzles were collected post-operatively and stored at 23°C ± 1°C prior to testing. The percentage porosities were determined by measuring the apparent densities based on Archimedes principle and, as a direct result; it was possible to calculate the mean percentage porosities.
Figure 2 illustrates a bar chart representing the bone cement porosity as a function of which orthopaedic theatre the cement was prepared. There was no significance difference when comparing the quality of the cement mixed in terms of porosity with the different theatres. The mean porosity values of the cement mixed ranged between 2.5% and 5.2% depending on which theatre was used.
As a consequence of this investigation it is recommended that the key to ensuring high quality bone cement, with a good mechanical strength, that can be consistently prepared in theatre by scrub staff are two fold.
The orthopaedic staff must be aware of the significance of cement mixing and how it is affected by a number of factors including the type of mixing system, vacuum level applied, and mixing technique. Education in the use of vacuum mixing systems should be ongoing and frequent. Practice mixing in non-clinical situations and feedback through quality measurements is particularly important.
The term ‘posterior condylar offset’ (PCO) is defined as the distance from a line projected along the posterior cortex of the femur to the maximum convexity of the posterior condyles. Furthermore its magnitude has been found to correlate with final flexion following PCL-retaining TKA, if reduced by more than 3mm post-operatively
Of the three patients whose PCO was reduced by more than 3mm, one had exactly the same flexion 1 year post-operatively, one had an increase of 14 degrees, and unfortunately the third died before their 1 year review. Using regression analysis, the strongest predictor of one-year flexion for this study group was the preoperative flexion value. The difference in PCO before and after TKA had no significant influence on one-year flexion.
Two hundred and eight consented patients (24.2%) were identified from 860 primary knee arthroplasties carried out over a 33-month period by a single surgeon. An LCS mobile bearing prosthesis was used in all cases. The mean valgus deformity measured 12.1 degrees (range 1–38). Fifty four percent of patients had a deformity of greater than 10 degrees. The patella was not resurfaced in any patient.
Of note 61 (29.3%) patients required a lateral patellar release for patellar maltracking. No patellar complications were noted. Mean patellar tilt was 1.1 degrees (sd=0.6 degrees) and mean patellar congruency 98% (sd=0.7%).
The mean diameter of the proximal femur increased from 12.99mm in males less than 60 years to 13.47mm in those of over 60. This increase was not statistically significant (p-value 0.064, 95% CI). In females there was a statistically significant increase in the mean diameter from 11.38mm in the under 60 age group to 12.90mm in those over 60 ( p-value 0.000, 95% CI).
We report a series of 668 patients (699 hips) with an average follow up of 10.5 years (range, 10–11 years) following THR using a cemented custom-made titanium femoral stem and a cemented high-density polyethyl-ene acetabular component. The fate of every implant is known. The mean age at operation was 68 years (24 – 94 years). The indication for THR was as follows: primary OA (629), RA (18), AVN (10), intracapsular femoral neck fracture (5), Perthes disease (3), developmental hip dysplasia (2) and SUFE (1). The mean pre-operative Harris Hip Score was 19 (range 10 – 42). One hundred and seventy-four patients (26%) were deceased at the time of their 10-year review. Four hundred and ninety-four patients were subsequently reviewed of which 88 patients (13%) were assessed by telephone review as they were too frail to attend. The average 10-year Harris Hip Score was 92 (range 43 – 100). The average 10-year Oxford Hip Score was 19 (range 12 – 46). 99.2% reviewed at 10 years stated that they were satisfied with their THR. Revision surgery occurred in 21 cases (3%). Seventeen femoral components were revised for infection, one for recurrent dislocation and one was iatrogenically loosened during socket revision. There were no cases of revision for aseptic loosening of the stem. Dislocation occurred in 18 cases, of which 4 became recurrent (0.6%). Six patients had a postoperative sciatic nerve palsy (0.9%) with 4 making a full recovery. There was one case of femoral nerve palsy. Eleven patients developed a DVT (1.6%). Six patients had a PE (0.9%) all of which were non-fatal. There were 16 deep and 3 superficial wound infections. Thirty-eight patients had symptomatic trochanteric bursitis post-surgery. In conclusion, the 10-years results of the custom femoral stem are encouraging with an overall high level of patient satisfaction.
Average estimated peri-operative blood loss for the standard incision group was 3.45 units and for the minimal incision group was 3.05 units (statistically significant, p-value 0.039, 95%CI). One patient after minimal incision had a superficial wound infection, which responded to oral antibiotics. There was one dislocation (standard incision).
The overall 1-year mortality was 31.4% (235/748) and the sex distribution (male 73/153 [47.7%] female 162/595 [27.2%]). 27/748 patients who did not undergo surgical intervention had a 1-year mortality of 85.2%. Factors which were associated with an increased 1 year mortality were: male sex (p<
0.0005), High ASA score (p<
0.0005), low Barthel score (p<
0.0005), poor mental score (p<
0.0005), decreased mobility (p<
0.0005), increased dependency in home circumstances (p<
0.0005), increased age (p<
0.0005), increased delay to surgery (p<
0.0005) and living alone (p<
0.0005). Marital status, fracture type and type of operative intervention had no statistical effect on mortality. Using logistic regression male sex, high ASA score, increased age, increased delay to surgery and poor mental score all remained independently associated with an increased mortality at 1 year.