Advertisement for orthosearch.org.uk
Results 1 - 17 of 17
Results per page:
Bone & Joint Open
Vol. 2, Issue 5 | Pages 293 - 300
3 May 2021
Lewis PM Khan FJ Feathers JR Lewis MH Morris KH Waddell JP

Aims

“Get It Right First Time” (GIRFT) and NHS England’s Best Practice Tariff (BPT) have published directives advising that patients over the ages of 65 (GIRFT) and 69 years (BPT) receiving total hip arthroplasty (THA) should receive cemented implants and have brought in financial penalties if this policy is not observed. Despite this, worldwide, uncemented component use has increased, a situation described as a ‘paradox’. GIRFT and BPT do, however, acknowledge more data are required to support this edict with current policies based on the National Joint Registry survivorship and implant costs.

Methods

This study compares THA outcomes for over 1,000 uncemented Corail/Pinnacle constructs used in all age groups/patient frailty, under one surgeon, with identical pre- and postoperative pathways over a nine-year period with mean follow-up of five years and two months (range: nine months to nine years and nine months). Implant information, survivorship, and regular postoperative Oxford Hip Scores (OHS) were collected and two comparisons undertaken: a comparison of those aged over 65 years with those 65 and under and a second comparison of those aged 70 years and over with those aged under 70.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 13 - 13
1 Aug 2020
Atrey A Wu J Waddell JP Schemitsch EH Khoshbin A Ward S Bogoch ER
Full Access

The purpose of this investigation is to assess the rate of wear the effect once the “bedding in period”/ poly creep had been eliminated. Creep is the visco-elastic deformation that polyethylene exhibits in the first 6–12 weeks. We also assessed the wear pattern of four different bearing couples in total hip arthroplasty (THA): cobalt-chrome (CoCr) versus oxidized zirconium (OxZir) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) versus highly-crosslinked polyethylene (XLPE) acetabular liners.

This was a randomized control study involving 92 patients undergoing THA. They were randomized to one of four bearing couples: (1) CoCr/UHMWPE (n= 23), (2) OxZir/UHMWPE (n=21), (3) CoCr/XLPE (n=24), (4) OxZir/XLPE (n=24). Patients underwent a posterior approach from one of three surgeons involved in the study. All patients received a porous-coated cementless acetabular shell and a cylindrical proximally coated stem with 28 mm femoral heads. Each patient was reviewed clinically and radiographically at six weeks, three and 12 months, two, five and 10 years after surgery. Standardized anteroposterior and lateral radiographs were taken. All polyethylene wear was measured by an independent blinded reviewer. Linear and volumetric wear rates were measured on radiographs using a validated computer software (Polyware Rev. 5). Creep was defined as the wear at 6 or 12 weeks, depending on if there was a more than 10% difference between both measurements. If a greater than 10% difference occurred than the later period's wear would be defined as creep.

72 hips were included in analysis after exclusion of seven revisions, three deaths and 10 losses to follow-up. The annual linear wear rates (in mm/y) at 10 years were (1) 0.249, (2) 0.250, (3) 0.074 and (4) 0.050. After adjusting for creep these rates become were (1) 0.181, (2) 0.142, (3) 0.040 and (4) 0.023. There is statistical differences between raw and adjusted linear wear rates for all bearing couples. The percentage of the radiographically measured wear at 10 years due to creep is (1) 30% (2) 44%, (3) 58.5% and (4) 51.5% with significant differences in couples with XLPE versus those with UHMWPE. There was no significant correlation between age, gender, cup size, tilt, planar anteversion and the linear or volumetric wear rates.

The linear wear rate of both UHMWPE and XLPE are even lower thxdsxzan previously described when creep is factored out. XLPE has again demonstrated far superior linear wear rates at 10 years than UHMWPE. There were no significant differences in wear rate at 10 years between CoCr and OxZir, this may be due to an underpowered study. XLPE exhibits proportionally more creep than UHMWPE within the first 6–12 weeks and accounts for more of the total wear at 10 years as measured radiographically at the end period.


Bone & Joint Open
Vol. 1, Issue 6 | Pages 198 - 202
6 Jun 2020
Lewis PM Waddell JP

It is unusual, if not unique, for three major research papers concerned with the management of the fractured neck of femur (FNOF) to be published in a short period of time, each describing large prospective randomized clinical trials. These studies were conducted in up to 17 countries worldwide, involving up to 80 surgical centers and include large numbers of patients (up to 2,900) with FNOF. Each article investigated common clinical dilemmas; the first paper comparing total hip arthroplasty versus hemiarthroplasty for FNOF, the second as to whether ‘fast track’ care offers improved clinical outcomes and the third, compares sliding hip with multiple cancellous hip screws. Each paper has been deemed of sufficient quality and importance to warrant publication in The Lancet or the New England Journal of Medicine. Although ‘premier’ journals, they only occationally contain orthopaedic studies and thus may not be routinely read by the busy orthopaedic/surgical clinician of any grade. It is therefore our intention with this present article to accurately summarize and combine the results of all three papers, presenting, in our opinion, the most important clinically relevant facts.

Cite this article: Bone Joint Open 2020;1-6:198–202.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 161 - 161
1 Sep 2012
Waddell JP Edwards M Lutz M Keast-Butler O Escott B Schemitsch EH
Full Access

Purpose

To review prospectively collected data on patients undergoing primary total hip arthroplasty utilizing two different cementless acetabular components.

Method

All patients undergoing primary total hip replacement surgery at our institution are entered prospectively into a database which includes history and physical examination, radiology, WOMAC and SF-36 scores. The patients are re-examined, re-x-rayed and re-scored at 3 months, 6 months and 1 year after surgery and yearly thereafter.

Using this database we are able to identify patients who have undergone total hip replacement using one of two geometric variants of the acetabular component. The first design is hemispherical and the second design has a peripheral rim expansion designed to increase initial press-fit stability.


Bone & Joint Research
Vol. 1, Issue 9 | Pages 205 - 209
1 Sep 2012
Atrey A Morison Z Tosounidis T Tunggal J Waddell JP

We systematically reviewed the published literature on the complications of closing wedge high tibial osteotomy for the treatment of unicompartmental osteoarthritis of the knee. Publications were identified using the Cochrane Library, MEDLINE, EMBASE and CINAHL databases up to February 2012. We assessed randomised (RCTs), controlled group clinical (CCTs) trials, case series in publications associated with closing wedge osteotomy of the tibia in patients with osteoarthritis of the knee and finally a Cochrane review. Many of these trials included comparative studies (opening wedge versus closing wedge) and there was heterogeneity in the studies that prevented pooling of the results.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 163 - 163
1 Sep 2012
Kuzyk PR Sellan M Morison Z Waddell JP Schemitsch EH
Full Access

Purpose

Femoroacetabular impingement (FAI) may contribute to the development of early onset hip osteoarthritis (OA). A cam lesion (or pistol grip deformity) of the proximal femur reduces head-neck offset resulting in cam type FAI. The alpha angle is a radiographic measurement recommended for diagnosis of cam type FAI. The purpose of this study was to determine if patients that develop end stage hip OA prior to 55 years of age have radiographic evidence of cam type FAI.

Method

The anteroposterior (AP) pelvis and lateral hip radiographs of 244 patients (261 hips) who presented to our institution for hip arthroplasty or hip fracture fixation between 2006 and 2008 were retrospectively reviewed. Three cohorts were compared: 1) patients with end stage hip OA < 55 years old (N=76); 2) patients with end stage hip OA > 55 years old (N=84); 3) hip fracture patients > 65 years old without radiographic evidence of hip arthritis were used as controls (N=101). Patients with inflammatory arthritis, avascular necrosis and post-traumatic hip OA were excluded. Alpha angles were measured on the AP pelvis and lateral radiographs by three coauthors using ImageJ 1.43 software (National Institutes of Health, USA). For patients with end stage hip OA, AP alpha angles were measured on both the hip with OA and the contralateral hip. Lateral alpha angles were measured only on the hip with OA. For patients with hip fracture, AP alpha angles were measured on the non-fractured hip and lateral alpha angles were measured on the fractured hip. A one-way ANOVA with post hoc Tukeys HSD test was used to compare the AP and lateral alpha angles for the three cohorts.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 114 - 114
1 Sep 2012
Olsen M Sellan M Zdero R Waddell JP Schemitsch EH
Full Access

Purpose

The Birmingham Mid-Head Resection (BMHR) is a bone-conserving, short-stem alternative to hip resurfacing for patients with compromised femoral head anatomy. It is unclear, however, if an uncemented, metaphyseal fixed stem confers a mechanical advantage to that of a traditional hip resurfacing in which the femoral prosthesis is cemented to the prepared femoral head. Thus, we aimed to determine if a metaphyseal fixed, bone preserving femoral component provided superior mechanical strength in resisting neck fracture compared to a conventional hip resurfacing arthroplasty.

Method

Sixteen matched pairs of human cadaveric femurs were divided evenly between specimens receiving a traditional epiphyseal fixed hip resurfacing arthroplasty (BHR) and those receiving a metaphyseal fixed BMHR. Pre-preparation scaled digital radiographs were taken of all specimens to determine anatomical parameters as well as planned stem-shaft angles and implant sizes. A minimum of 10 degrees of relative valgus alignment was planned for all implants and the planned stem-shaft angles and implant sizes were equal between femur pairs. Prior to preparation, bone mineral density scans of the femurs were obtained. Prepared specimens were potted, positioned in single-leg stance and tested to failure using a mechanical testing machine. Load-displacement curves were used to calculate construct stiffness, failure energy and ultimate failure load.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 107 - 107
1 Sep 2012
Waddell JP Nikolaou V Edwards M Bogoch E Schemitsch EH
Full Access

Purpose

This prospective randomised controlled trial aims to compare the clinical and radiological outcomes of ceramic on ceramic, cobalt chrome on ultra-high molecular weight polyethylene, and cobalt chrome on highly cross-linked polyethylene bearing surfaces at a minimum of five years.

Method

One hundred and two primary total hip replacements were performed in ninety one patients between February 2003 and March 2005. All patients were younger than 65 (mean 52.7, 19–64). They were randomised to receive one of the three bearing surfaces. All patients had 28mm articulations with a Reflection uncemented acetabular component and a Synergy stem (Smith & Nephew, Memphis, Tennessee). Patients were followed up periodically up to at least sixty months following surgery. Outcome measures included WOMAC and SF12 scores. Radiological assessment included implant position, evidence of osteolysis and measurement of linear wear.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 561 - 561
1 Nov 2011
Walmsley DW Peskun C Waddell JP Schemitsch EH
Full Access

Purpose: There is growing support in the medical literature that patient outcomes are adversely affected by physician fatigue in operator-dependent cognitive and technical tasks. The recent increase in total joint arthroplasty case load has resulted in longer operative days and increased surgeon fatigue. The purpose of this study was to determine if time of day predicts perioperative outcomes and complications in total hip and knee arthroplasty surgery.

Method: The records of all primary Total Hip Arthroplasty (THA) and Total Knee Arthroplasty (TKA) surgery performed for primary osteoarthritis, during 2007 at one large university hospital, were retrospectively reviewed. Complete demographic data (age, gender, Body Mass Index), start time of surgery, intraoperative complications, duration of surgery, radiographic component alignment, and functional outcome scores (SF-12 and WOMAC) for 341 THA and 292 TKA patients were collected and analyzed using linear and nonparametric rank correlation statistics. Data was corrected for gender, body mass index (BMI), surgeon, and post-call operating days.

Results: In the THA cohort, a later start time of surgery was significantly related to duration of surgery (p=0.0013). In addition, there was a trend towards significance for intraoperative femur fracture (p=0.0542) later in the day. Postoperative complications, component alignment, and functional outcome scores were not significantly affected by start time of surgery. There were no significant findings for any of the intraoperative or postoperative outcomes in the TKA cohort.

Conclusion: This study demonstrates that duration of surgery and the incidence of intraoperative complications for THA may increase as the start time of surgery becomes later in the day. These findings should be taken into consideration when planning operative days involving THA.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 573 - 573
1 Nov 2011
Waddell JP McMullan J McGlasson R Mahomed NN Flannery J
Full Access

Purpose: Fractures of the proximal femur are increasing in incidence as the population ages. In order to address this problem the Province of Ontario, Canada (population 14 million) has advocated an integrated model of care.

Method: A policy to improve the outcome for patients sustaining hip fractures has been developed. It has been implemented in the 14 health regions of the province. The objectives are:

All surgical procedures to be performed within 48 hours of patient’s admission to hospital.

Surgical treatment of hip fractures must permit unrestricted weight bearing.

A structured acute care post-operative course followed by admission to progressive rehabilitation.

Results: Since the implementation of this policy 90% of all hip fracture patients are receiving definitive surgical treatment within 48 hours of admission. Site variations are identified and remedial actions implemented for those hospitals which fail to meet this target. Acute care length of stay following hip fracture has declined from a mean of 17 days to a mean of 8 days. The number of patients with hip fractures returning to their pre-injury residence has increased significantly from approximately 35% to 70% at 3 months post-fracture.

Conclusion: A structured program for hip fracture care can be developed in large population areas and has been implemented for the approximate 10,000 patients sustaining hip fractures annually within our jurisdiction. This model should be broadly applicable to other health regions.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 566 - 566
1 Nov 2011
Kuzyk PR Higgins G Tunggal J Schemitsch EH Waddell JP
Full Access

Purpose: The purpose of this study was to evaluate the accuracy and precision of 3 common methods used to produce posterior tibial slope during total knee arthroplasty.

Method: The study population consisted of 110 total knee arthroplasties in 102 patients that underwent total knee arthroplasty. All procedures were performed using a standard medial parapatellar approach and all knees were replaced using the Scorpio Knee System (Stryker, Mahwah, NJ) of implants and instruments. Three treatment groups were identified retrospectively based on the method used to produce the posterior tibial slope. Group 1 used an extramedullary guide with a 0 degree cutting block tilted by placing 2 fingers between the tibia and the extramedullary guide proximally and three fingers between the tibia and guide distally to produce a 3 degree posterior slope (N=40). Group 2 used computer navigation (Stryker Navigation System, Stryker, Mahwah, NJ) to produce a 3 degree posterior slope (N=30). Group 3 used an extramedullary guide placed parallel to the anatomic axis of the tibia with a 5 degree cutting block to produce a 5 degree posterior slope (N=40). Posterior tibial slope was measured from lateral radiographs by 2 independent reviewers that were blinded to the treatment group. The reported posterior tibial slope for each sample was an average of these two measurements. Accuracy of the treatment group was evaluated using a one sample t test. Groups 1 and 2 were tested for an ideal slope of 3 degrees, and Group 3 was tested for an ideal slope of 5 degrees. An a priori sample size calculation with α=0.05 and β=0.20 showed that at least 24 samples in each treatment group were required to determine a difference of 1.5 degrees between the treatment group mean posterior tibial slope and the ideal posterior tibial slope.

Results: The mean posterior slope measurements for treatment Group 1 (4.15±3.24 degrees) and treatment Group 2 (1.60±1.62 degrees) were both significantly different than the ideal slope of 3 degrees (p=0.03 for Group 1 and p< 0.01 for Group 2). This indicates that treatment Groups 1 and 2 failed to accurately produce the ideal posterior tibial slope of 3 degrees. The mean posterior tibia slope of treatment Group 3 (5.00±2.87 degrees) was not significantly different than the ideal posterior tibial slope of 5 degrees (p=1.00). This indicates that Group 3 accurately produced the ideal tibial slope of 5 degrees.

Conclusion: The most accurate method to produce posterior tibial slope was the 5 degree cutting block with an extramedullary guide. Computer navigation had the lowest standard deviation and therefore was the most precise method. However, computer navigation was not as accurate in producing the desired posterior tibial slope as the extramedullary guide with the 5 degree cutting block. The manual method of producing tibial slope with an extramedullary guide and a 0 degree cutting block was the least precise method and not as accurate as the extramedullary guide with a 5 degree cutting block.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 573 - 573
1 Nov 2011
Kuzyk PR Zdero R Shah S Olsen M Waddell JP Schemitsch EH
Full Access

Purpose: Minimizing tip-apex distance (TAD) has been shown to reduce clinical failure of extramedullary sliding hip screws used to fix peritrochanteric fractures. There is debate regarding the optimal position of the lag screw in the femoral head when a cephalomedullary nail is used to treat a peritrochanteric fracture. Some authors suggest the TAD should be minimized as with an extramedullary sliding hip screw, while others suggest the lag screw should be placed inferior within the femoral head. The primary goal of this study was to determine which of 5 possible lag screw positions in the femoral head provides greatest mechanical stiffness and/or load-to-failure for an unstable peritrochanteric fracture treated with a cepha-clomedullary nail. The secondary goal was to determine if there is a linear correlation between implant-femur mechanical stiffness and/or load to failure (dependent variables) with a series of five radiographic measurements (independent variables) of distance from the lag screw tip to the femoral head apex.

Method: Long Gamma 3 Nails (Stryker, Mahwah, NJ) were inserted into 30 left synthetic femurs (Pacific Research Laboratories, Vashon, WA). An unstable four-part fracture was created, anatomically reduced, and repaired using one of 5 lag screw placements in the femoral head:

superior (n=6),

inferior (n=6),

anterior (n=6),

posterior (n=6),

central (n=6).

All specimens were radiographed in the anterioposterior and lateral planes, and radiographic measurements including TAD and a calcar referenced tip-apex distance (CalTAD) were calculated. All specimens were tested for axial, lateral, and torsional stiffness, and then loaded-to-failure in the axial position using an Instron 8874 (Canton, MA). ANOVA was used to compare means of the five treatment groups. Linear regression analysis was used to compare stiffness and load-to-failure (dependant variables) with radiographic measurements (independent variables). A post hoc power analysis was performed.

Results: The inferior lag screw position had significantly greater mean axial stiffness than superior (p< 0.01), anterior (p=0.02) and posterior (p=0.04) positions. Analysis revealed significantly less mean torsional stiffness for the superior lag screw position compared to other lag screw positions (p< 0.01 all 4 pairings). No statistical differences were noted for lateral stiffness. Superior and central lag screw positions had significantly greater mean load-to-failure than anterior (p< 0.01 and p=0.02) and posterior (p< 0.01 and p=0.05) positions.

There were significant negative linear correlations between stiffness tests with CalTAD, and load-to-failure with TAD. Power was greater than 95% for axial stiffness, torsional stiffness and load-to-failure tests.

Conclusion: Position of the lag screw in the femoral head affects the biomechanical properties of the implant-femur construct. Central placement of the lag screw with minimization of TAD may provide the best combination of stiffness and load-to-failure.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 574 - 574
1 Nov 2011
Kuzyk PR Zdero R Shah S Olsen M Waddell JP Schemitsch EH
Full Access

Purpose: Cephalomedullary nails rely on a large lag screw that provides fixation into the femoral head. There is an option to statically lock the lag screw (static mode) or to allow the lag screw to move within the nail to compress the intertrochanteric fracture (dynamic mode). The purpose of this study was to compare the biomechanical stiffness of static and dynamic modes for a cephalomedullary nail used to fix an unstable peritrochanteric fracture.

Method: Thirty intact synthetic femur specimens (Model #3406, Pacific Research Laboratories, Vashon, WA) were potted into cement blocks distally for testing on an Instron 8874 (Instron, Canton, MA). A long cephalomedullary nail (Long Gamma 3 Nail, Stryker, Mahwah, NJ) was then inserted into each of the femurs. An unstable four-part fracture was created, anatomically reduced, and the cephallomedullary nail was reinserted. Mechanical tests were conducted for axial, lateral, and torsional stiffness with the lag screws in:

static and

dynamic modes.

A paired student’s t test was used to compare the 2 modes.

Results: The axial stiffness of the cephalomedullary nail was significantly greater (p< 0.01) in the static mode (484.3±80.2N/mm) than in the dynamic mode (424.1±78.0N/mm) (Fig.2A). Similarly, the lateral bending stiffness of the nail was significantly greater (p< 0.01) in the static mode (113.9±8.4N/mm) than in the dynamic mode (109.5±8.8N/mm). The torsional stiffness of the nail was significantly greater (p=0.02) in the dynamic mode (114.5±28.2N/mm) than in the static mode (111.7±27.0N/mm).

A post hoc power analysis with & #945;=0.05 and & #946;=0.20 revealed that the paired t test on 30 samples was sufficiently powered to determine a difference in mean axial stiffness of 33.0N/mm (6.8% of static stiffness), a difference in mean lateral bending stiffness of 3.6N/mm (3.2% of static stiffness) and a difference in mean torsional stiffness of 3.4N/mm (3.0% of static stiffness).

Conclusion: Our results show that there is a 60N/mm reduction in axial stiffness of the cephalomedullary nail when the lag screw is changed from static to dynamic mode. This represents a 12.4% reduction in axial stiffness with a change from axial to dynamic modes which may be clinically significant. The differences in lateral (4.4N/mm, 3.9%) and torsional (2.8N/mm, 2.4%) are small enough that they are likely not clinically significant. We felt that a difference of greater than 10% in axial stiffness and a difference of greater than 5% in lateral or torsional stiffness would be clinically significant. Our study was adequately powered to detect these differences. Given the significant reduction in axial stiffness with dynamization of the cephalomedullary nail construct, we recommend use of the static mode when treating unstable peritrochanteric fractures with a cephalomedullary nail.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 253 - 253
1 Jul 2011
Lewis P Al-Belooshi A Olsen M Schemitsch EH Waddell JP
Full Access

Purpose: The use of UHMW polyethylene acetabular liners is known to cause polyethylene wear related osteolysis, the major limiting factor in its use in the younger active patient. Modern alumina ceramic articulations have been developed in order to reduce wear and avoid polyethylene debris. This prospective randomized long-term study aims to compare the outcome between an alumina ceramic-on-ceramic (CC) articulation with a ceramic on UHMW polyethylene articulation (CP).

Method: Fixty-six hips in 55 patients with mean age 42.2 (range 19–56) each received uncemented components (Wright Medical) and a 28mm alumina head with acetabular liner selected via sealed envelope randomization following anesthetic induction. Subsequent regular clinical and radiologic follow up measured patient outcome scores and noted any radiological changes.

Results: Twenty-six CP hips and 30 CC hips were evaluated. One failure required revision in each group. Mean St Michael’s outcome score for each group with up to 10 years follow-up (median 8 years, range 1–10) was 22.8 and 22.9 respectively (p=0.057). Radiographs with a minimum 5 years post-operative follow-up were analyzed in 42 hips (23 CC and 19 CP). The mean time of wear measurement for the CC group was 8.3 years (SD 1.3, Range 4.8–10.1 years) and for the CP group was 8.1 years (SD 0.9, Range 6.1–9.2 years)(p=0.471). Wear was identified in all but one CP hip but in only 12 of 23 CC replacements. Mean wear in the CP group was 0.11mm per year and 0.02mm per year in the CC group (p< 0.001).

Conclusion: To our knowledge this is the first long term randomized trial comparing in-vivo ceramic-on-ceramic with ceramic-on-polyethylene hip articulations. Other than significantly greater wear in the polyethylene group there was no significant difference in long-term outcome scores between the two groups with up to 10 years of follow-up. The use of a ceramic-on-ceramic bearing is a safe and durable option in the young patient avoiding the concerns of active metal ions and osteolytic polyethylene debris.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 254 - 254
1 Jul 2011
Lewis P Olsen M Schemitsch EH Waddell JP
Full Access

Purpose: While the durability of most uncemented femoral stems remains unknown, it is the aim of this study to demonstrate Echelon Primary femoral stem performance with regard patient outcome and overall implant survival.

Method: Between February 1998 and March 2007, 428 patients received the Echelon Primary stem. The mean age of each patient was 58.1 (SD 11.1, Range 20–87). Body mass index averaged 30.5 kg/m2 (SD 5.8, Range 17.7–58.2). The majority of patients received a Reflection uncemented acetabular component (91%) and an ultra high molecular weight polyethylene liner (76.5%), although the highly cross linked polyethylene is now used with increased frequency, used in 31% of hips since 2005. The majority of femoral heads were cobalt chrome (79.3%).

Results: Kaplan Meier survivorship for the Echelon Femoral stem with revision for aseptic loosening as end point at 100 months is 99.3% (95% CI 97.1–99.8). Taking revision for any reason as the end point the Kaplan Meier survivorship is 98.3% at 100 months (95% CI 95.9–99.3). A pre-operative WOMAC score was available for 345 of the 392 patients with mean score of 43.5 (95% CI 41.6–45.4). At the three-month post-operative review the mean WOMAC score was significantly increased to 74.54 (95% CI 72.7–76.3)(p< 0.001) and by 1 year 84.3 (95% CI 80.5–88.1). At subsequent years, the modified WOMAC score remained at a plateau of around 80. General health assessment using the SF-36 shows an improvement in the physical component score from 33.1 (95% CI 32.3–33.9) preoperatively to 42.6 (95% CI 41.7–43.6)(p< 0.001) at three months and 48.19 (95% CI 44.2–52.2) at latest follow up. The mental component scores increased from 48.7 (95% CI 47.6–49.9) to 51.4 (95% CI 50.3–52.4)(p< 0.001) and 53.5 (95% CI 50.3–56.6) respectively.

Conclusion: This large prospective review of the Echelon Primary femoral stems reveals an excellent survivorship of the stem with a 99.3% survival at 8 years with regard aseptic loosening and 98.3% survival including revision for any reason. Patient outcome scores are significantly improved and subsequently maintained. There have been no changes with regard to manufacture or design of the stem within the period of review.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 255 - 255
1 Jul 2011
Olsen M Davis ET Waddell JP Schemitsch EH
Full Access

Purpose: Hip resurfacing is a technically demanding alternative to total hip arthroplasty. Placement of the initial femoral guidewire utilizing traditional mechanical jigs may lead to preparatory errors and a high degree of variability in final implant stem-shaft angle (SSA). Intraoperative computer navigation has the potential to decrease preparatory errors and provide a reliable method of femoral component placement. The current study evaluated the accuracy and learning curve of 140 consecutive navigated hip resurfacing arthroplasties.

Method: Between October 2005 and May 2007, 140 consecutive Birmingham Hip Resurfacings were performed on 132 patients (107 male, 25 female). The mean age of the cohort was 51.2 years (range 25–82). Indications for surgery included osteoarthritis (n=136) and avascular necrosis (n=4). Preoperative templating was performed using digital AP unilateral hip radiographs. Neck-shaft angles (NSA) were digitally measured and relative implant stem-shaft angles planned. The central guidewire was drilled and verified intra-operatively using an imageless navigation system. Implant stem-shaft angles were assessed using 3 month post-operative radiographs.

Results: Pre-operative templating determined a mean NSA of 132.2 degrees (SD 5.3 degrees, range 115–160). The planned SSA was a relative valgus alignment of 9.5 degrees (SD 2.6 degrees). The post-operative SSA differed from the planned SSA by 2.5 degrees (SD 1.9 degrees, range 0–8). The final SSA measured within ±5 degrees of the planned SSA in 89% of cases. Of the remaining 11% of cases, all measurements erred in valgus. No cases of neck notching or varus implant alignment occurred in the series. The mean navigation time for the entire series was 18 minutes (SD 6.6 minutes, range 10–50). A learning curve was observed with respect to navigation time, with a significant decrease in navigation time between the first 20 cases and the remainder of the series. There was no evidence of a learning curve for implant placement accuracy.

Conclusion: Imageless computer navigation shows promise in optimizing preparation of the femoral head and reducing the introduction of mechanical preparatory factors that predispose to femoral neck fracture. Navigation may afford the surgeon an accurate and reliable method of femoral component placement with negligible learning curve.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 1 - 1
1 Mar 2010
Li CH Li R Waddell JP Schemitsch EH
Full Access

Purpose: Vascular Endothelial Growth Factor (VEGF) is vital for both angiogenesis and osteogenesis. The aim of this study was to investigate the effect of cell based VEGF gene delivery on the proliferation and mineralization of rabbit osteoblasts in vitro.

Method: Primary cultured rabbit osteoblasts were divided into four groups (each n=6). In Group I, osteoblasts were transfected with pcDNA3.1-VEGF; in Group II, osteoblasts were transfected with pcDNA-Efficiency Green Fluorescent Protein (EGFP); in Group III, osteoblasts were treated with the supernatant of fibroblasts that were transfected with VEGF genes; and in Group IV, osteoblasts were treated with the supernatant of fibroblasts that were transfected with EGFP. The cells were cultured in a-EME with 10% FBS, 2% penicillin/streptomycin with or without 10-^7 M dexamethasone and 50μg/ml L-ascorbic acid for 28 days. In the last 4 days, the cells were stimulated to initiate calcium mineralized nodule formation by adding 10 mM B-glycerophosphate. They were stained by the Von Kossa technique so that the number and the area of the nodules could be assessed by an imaging analysis system.

Results: The cells transfected by VEGF were indicated by the EGFP marked cells under a fluorescent microscope. There was a significant difference in the total nodule area (mean 18.38 mm2 SE 3.73 and 5.07 mm2 SE 0.55, p< 0.05) and count (mean 18.67 SE 3.22 and 2.17 SE 0.40, p< 0.001) between Group I and Group II (ANOVA, SPSS). More unmineralized and smaller nodules were found in Group III and Group IV. However, the nodules in Group III covered greater areas with dark brown staining in the cell culture dishes when compared with Group IV.

Conclusion: The observations indicate that cell based VEGF gene delivery has a positive effect on the proliferation and mineralization of osteoblasts. The greatest effect is seen with direct transfection of osteoblast cells. Cell-based VEGF gene therapy may be used to promote fracture healing.